Amprobe ACDC-400 Specifications

Data Sheet
ACDC-400
Digital AC/DC Clamp-on Multimeter
The Amprobe ACDC-400 clamp meter is full featured with wide measurement capabilities. It measures both AC and DC Current to 400 amps, AC and DC Voltage to 600V, plus Re­sistance and Continuity. The ACDC-400 also offers software features of Min/Max and Relative measurements with a large digital and analog combined display and backlight.
AC/DC Current up to 400A
AC/DC Voltage up to 600V
Resistance measurement
Continuity test
Data Hold
No hassle warranty
No waiting.
No shipping charges.
(note: $500 MSLP limit)
MAX/MIN recording
Relative measurement
Backlight
Analog bargraph
Auto or Manual range selection
Max Conductor 29.97 mm (1.18”)
Includes carrying case
CAT III 600V
Amprobe® Test Tools
www.Amprobe.com
ACDC-400 Digital AC/DC Clamp-on Multimeter
Data Sheet
Specifications
General Specifications
Display 3-3/4 digits 4000 counts LCD display Update Rate 2 per second nominal Polarity Automatic Power Supply 2 standard 1.5V AA A Size (NEDA 24G or IEC R03) battery Battery Life typical 25 hours APO Timing idle for 30 minutes Low battery on LCD; approx. 2.4V Environment Indoor operation, below 2000 m Temperature / Humidity Operating: 5°C to 40°C (41°F to 104°F), < 80% RH; Storage: -10°C to 60°C (14°F to 122°F), < 80% RH Jaw opening 27mm (1.1 in) max Dimension 202 x 70 x 40mm (7.9 x 2.7 x 1.6 in.) Weight 254 gm (0.6 lb) Safety LVD Meets EN60101-1:2001; EN61010-2-032(2002), Category II- 600 Volts ac
& dc; pollution degree : 2; class 2
EMC EN61326-1:2006
Electrical Specifications (23 °C ± 5 °C) < 75%RH
DC Voltage Range Accuracy
Input impedance 10M, 30pf nominal ( 100 M for 400.0mV range) Max input 600 VDC
AC Voltage (sinusoidal) Range Frequency Accuracy
Input impedance 10M, 30pf nominal ( 100 M for 400.0mV range) Max input 600 VAC rms
DC Current (Clamp-On) Range Accuracy
Max current 400A rms continuous; 600 A rms ( 60 seconds)
ACA Current (Clamp-On) (sinusoidal) Range Frequency Accuracy
0.00A to 40.00A 50Hz to 60Hz ± (2.0% rdg + 10 dgts)
40.0A to 400.0A 50Hz to 60Hz ± (2.0% rdg + 10 dgts)
Max current 400A rms continuous; 600 A rms ( 60 seconds)
Resistance Range Accuracy
Open Circuit Voltage 0.45 Vdc typical; 1.5 Vdc typical for 400.0
Continuity Tester Open Circuit Voltage: 1.4Vdc typical
400.0 mV 4.000V, 40.00V, 400.0V ± (0.8% rdg + 2 dgts) 600V ± (1.0% rdg + 2 dgts)
400.0mV 40Hz to 60Hz ± (1.0% rdg + 50 dgts)
4.000V, 40.00V, 400.0V 50Hz to 500Hz ± (1.0% rdg + 3 dgts) 600V 50Hz to 500Hz ± (1.2% rdg + 3 dgts)
0.00A to 40.00A ± (2.0% rdg + 10 dgts)
40.0A to 400.0A ± (2.0% rdg + 10 dgts)
400.0 ± (1.0% rdg + 5 dgts)
4.000kΩ, 40.00kΩ, 400.0kΩ, 4.000MΩ ± (1.0% rdg + 3 dgts)
40.00M ± (3.0% rdg + 3 dgts)
Audible threshold: < 40
Amprobe® Test Tools
website: www.Amprobe.com email: info@amprobe.com Everett, WA 98203 Tel: 877-AMPROBE
Amprobe® Test Tools
Amprobe® Test Tools Europe
Amprobe Test Tools Europe Beha-Amprobe GmbH In den Engematten 14 79286 Glottertal, Germany Tel.: +49 (0) 7684 8009 - 0
©2008 Amprobe Test Tools. All rights re served. 10/2008 3320124 Rev A
www.Amprobe.com
Loading...