Amprobe ACDC-100, ACDC-100 TRMS Users Manual

Users Manual
Mode d’emploi• Bedienungshandbuch• Manuale d’Uso• Manual de uso• Användarhandbok•
ACDC-100 TRMS ACDC-100
Versatile AC/DC Clamp-on Multimeter Series
Versatile AC/DC Clamp-on Multimeter Series
Users Manual
ACDC100_Rev002 © 2010 Amprobe Test Tools. All rights reserved.
1
English
Limited Warranty and Limitation of Liability
Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warrant y on Amprobe’s behalf. To obtain service during the warranty period, return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor. See Repair Section for details. THIS WARRANTY IS YOUR ONLY REMEDY. ALL OTHER WARRANTIES - WHETHER EXPRESS, IMPLIED OR STAUTORY - INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILIT Y, ARE HEREBY DISCL AIMED. MANUFAC TURER SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIREC T, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.
Repair
All test tools returned for warranty or non-warranty repair or for calibration should be accompanied by the following: your name, company’s name, address, telephone number, and proof of purchase. Additionally, please include a brief description of the problem or the ser vice reques ted and include the test leads with the meter. Non-warranty repair or replacement charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Amprobe
In-Warranty Repairs and Replacement – All Countries
Please read the warranty statement and check your battery before requesting repair. During the warranty period any defec tive test tool can be returned to your Amprobe Tools distributor for an exchange for the same or like produc t. Please check the “ Where to Buy” section on ww w.amprobe.com for a list of distributors near you. Additionally, in the United States and Canada In-Warrant y repair and replacement units can also be sent to a
®
Amprobe
Non-Warranty Repairs and Replacement – US and Canada
Non-warranty repairs in the United States and Canada should be sent to a Amprobe Tools Service Center. Call Amprobe current repair and replacement rates.
In USA In Canada
Amprobe Test Tools Amprobe Test Tools Everett, WA 98203 Mississauga, ON L4Z 1X9 Tel: 877-AMPROBE (267-7623) Tel: 905-890-760 0
Non-Warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Amprobe a nominal charge. Please check the “Where to Buy” section on w ww.amprobe.com for a list of distributors near you.
European Correspondence Address*
Amprobe In den Engematten 14 79286 Glottertal, Germany Tel.: +49 (0) 7684 8009 - 0
*(Correspondence only – no repair or replacement available from this address. European customers please contac t your distributor.)
Test Tools Service Center (see address below).
®
Test Tools or inquire at your point of purchase for
®
Test Tools Europe
®
Test Tools.
®
®
Test
®
Test Tools distributor for
Test
2
➊ Hall-effect Clamp Jaw
for AC & DC current electric field pick up
Hand/Finger Barrier
to indicate the limits of safe access of the meter during measurement
Push-buttons for
special functions & features
Input Jack for all
functions EXCEPT non­invasive ACA & DCA current functions
Common (Ground
reference) Input Jack for all functions EXCEPT non-invasive ACA & DCA current functions
Slide-switch Selector
to turn the power ON/OFF and Select a function
3-3/4 digits 4000
counts LCD display
➑ Jaw trigger for
opening the clamp jaw
➒ Jaw center Indicators,
at where best ACA & DCA accuracy is specified
3
Versatile AC/DC Clamp-on Multimeter Series
ACDC-100 TRMS / ACDC-100
CONTENTS
Symbols .............................................................................................................................................5
Safety Information ...........................................................................................................................5
Unpacking and Contents .................................................................................................................6
Introduction ......................................................................................................................................6
Features ...........................................................................................................................................6
Alignment marks .......................................................................................................................6
MAX / HOLD  .....................................................................................................................6
HOLD ..........................................................................................................................................7
MAX ............................................................................................................................................7
r Relative Zero mode ...............................................................................................................7
SELECT / Backlight ( ) ..............................................................................................................7
Manual or Auto-ranging ...........................................................................................................7
Auto Power Off function ..........................................................................................................7
Operation ........................................................................................................................................7
DC Voltage .................................................................................................................................7
AC Voltage .................................................................................................................................7
AC Current ..................................................................................................................................8
DC Current ..................................................................................................................................8
Resistance ...................................................................................................................................8
Continuity ...................................................................................................................................8
Diodes .........................................................................................................................................8
Capacitance ................................................................................................................................9
Maintenance and Repair ................................................................................................................9
Battery Replacement .................................................................................................................9
Specifications ..................................................................................................................................10
General Specifications ..............................................................................................................10
Electrical ..................................................................................................................................11
4
SYMBOLS
Battery
Double insulated
Direct Current
Alternating Current
Conforms to relevant Australian
standards.
Do not dispose of this product as
unsorted municipal waste.
Application around and removal from hazardous live conductors
is permitted
SAFETY INFORMATION
The ACDC-100 Series Digital Clampmeters conform to EN61010-1:2001; EN61010- 2-• 032:2002; CAT III 600 V, class 2 and pollution deg.2
This instrument is EN61010-1 certified for Installation Category III (600V). It is • recommended for use in distribution level and fixed installations, as well as lesser installations, and not for primary supply lines, overhead lines and cable systems.
Do not exceed the maximum overload limits per function (see specifications) nor the limits • marked on the instrument itself. Never apply more than 600 Vdc/600 V ac rms between the test lead and earth ground.
Refer to the manual
Dangerous Voltage
Earth Ground
Audible tone
Complies with EU directives
Underwriters Laboratories.
[Note: Canadian and US.]
Warnings and Precautions
Before and after hazardous voltage measurements, test the voltage function on a known • source such as line voltage to determine proper meter functioning.
Disconnect the test leads from the test points before changing meter functions.• Inspect the Clampmeter, test leads and accessories before every use. Do not use any •
damaged part. Never ground yourself when taking measurements. Do not touch exposed circuit elements •
or test probe tips. Do not operate the instrument in an explosive atmosphere.• To reduce the risk of fire or electric shock, do not expose this product to rain or moisture.• The meter is intended only for indoor use. To avoid electrical shock hazard, observe the •
proper safety precautions when working with voltages above 60 VDC or 30 VAC rms. These voltage levels pose a potential shock hazard to the user.
5
Loading...
+ 11 hidden pages