Amprobe ACD-16-TRMS-PRO Specifications

Data Sheet
600V
ACD-16 TRMS-PRO
1000A Data-Logging Clamp-on Multimeter
Need the perfect tool to troubleshoot a system? The ACD-16 TRMS­PRO provides a full range of measurements, enhanced with data logging capabilities, to catch what the eye can’t see. Double the efficiency, with an optional PC interface kit. True RMS for a more accurate signal in a noisy electrical environment.
No hassle warranty
No waiting.
No shipping charges.
True RMS
Backlight Measurements: AC/DC Voltage
up to 600V, AC Current up to 1000A, Resistance, Frequency and Temperature
Data-logging up to 5400 points
Optional PC interface
capability (RS-232 KIT2) Audible continuity
Auto power off Data hold Large, easy to read digital display Accommodates conductors up to
45mm (1.77”) in diameter Carrying case, Type k
thermocouple, test leads, batteries (installed) and user manual included
Voltage overload protection for
all functions up to 600V AC/DC
(note: $500 MSLP limit)
Amprobe® Test Tools
www.Amprobe.com
ACD-16 TRMS-PRO 1000A Data-Logging Clamp-on Multimeter
Data Sheet
Electrical Specifications: Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23 °C ± 5 °C & less than 75% R.H. True RMS Models ACD-16 TRMS-PRO ACV & ACA clamp-on accuracies are specified from 5% to 100% of range or otherwise specified. Maximum Crest Factor are as specified below, & with frequency spectrums, besides fundamentals, fall within the meter specified AC bandwidth for non-sinusoidal waveforms. Fundamentals are specified at 50Hz and 60Hz.
Function Range Accuracy
AC Voltage
50Hz / 60Hz 600.0 V 1.0% + 5d 45Hz ~ 500Hz 600.0 V 1.5% + 5d 500Hz ~ 3.1kHz 9 600.0 V 2.5% + 5d CMRR: >60dB @ DC to 60Hz, Rs=1kW Input Impedance: 2MW, 30pF nominal True RMS models Crest Factor: < 2.3 : 1 at full scale & < 4.6 : 1 at half scale
DC Voltage
600.0V 0.5% + 5d NMRR: >50dB @ 50/60Hz CMRR: >120dB @ DC, 50/60Hz, Rs=1kW Input Impedance: 2MW, 30pF nominal
Resistance
999.9W 1.0% + 6d Open Circuit Voltage: 0.4VDC typical Audible Continuity Tester
Audible threshold: between 10W and 300W. Response time: 250µs
Frequency
5.00Hz ~ 500.0Hz 0.5%+4d Sensitivity (Sine RMS)
40A range: > 4A 400A range: > 40A 1000A range: > 400A 600V range: > 30V
Temperature
-50°C ~ 300°C 2.0% + 3°C
-58°F ~ 572°F 2.0% + 6°F
1)
Add 3°C (or 6°F) to specified accuracy @ -20°C ~ -50°C (or @ -4°F ~ -58°F) Type-K thermocouple range & accuracy not included
1)
1)
AC Current (Clamp-on)
50Hz / 60Hz 40.00A, 400.0A, 1000A 1.0% + 5d 45Hz ~500Hz 40.00A, 400.0A 2.0% + 5d 1000A 2.5% + 5d
1) 2) 3)
1) 2) 3)
1) 2) 3)
500Hz ~ 3.1kHz
40.00A, 400.0A 2.0% + 5d 1000A 2.5% + 5d
1) 2) 3)
1) 2) 3)
True RMS models Crest Factor:
< 2.5 : 1 at full scale & < 5.0 : 1 at half scale for 40.00A & 400.0A ranges < 1.4 : 1 at full scale & < 2.8 : 1 at half scale for 1000A range
1)
Add 8d to specified accuracy while reading is below 10% of range
2)
Induced error from adjacent current-carrying conductor: < 0.06A/A
3)
Specified accuracy is for measurements made at the jaw center. When the conductor is not positioned at the jaw center, position errors introduced are: Add 1% to specified accuracy for measurements made WITHIN jaw marking lines (away from jaw opening) Add 4% to specified accuracy for measurements made BEYOND jaw marking lines (toward jaws opening)
Amprobe® Test Tools
www.Amprobe.com