Amprobe AC68C-TRMS Specifications

AC68C
600V
300V
TRMS Clamp Type Digital Multimeter
True RMS
Top-of-the-line professional clamp DMM
8 functions/11 ranges
AC and DC
Data and AC Peak Hold
DC auto zero
4000-count
Carrying case included
CAT II 600 V, CAT III 300 V rated
Data Sheet
No hassle warranty
No waiting.
No shipping charges.
(note: $500 MSLP limit)
General Specifications
Display: 3-3⁄4 digit, LCD, max reading of 3999 Display Update Rate: 2/sec, nominal Power: 9 V battery (NEDA 1604, IEC 6F22) Battery Life: 200 hours(Alkaline) Operating Temperature: 0 °C to + 40 °C < 80 % R.H. Storage Temperature: - 10 °C to + 60 °C, < 70 % R.H. non-condensing Maximum Jaw Opening: 40 mm (1.57˝ ) Dimensions (WxHxD): 76 x 228 x 39 mm (3˝ x 9˝ x 1.5˝) Weight (incl. Battery): 465 grams Warranty: One-year
Included Accessories
Users Manual, carrying case, test leads
Optional Accessories
DL243D Basic Test Lead Kit DL248D Deluxe Test Lead Kit TL35B Test Lead Set with Alligator Clips
Amprobe® Test Tools
www.Amprobe.com
AC68C Clamp Type Digital Multimeter
Specifications (23°C ± 5 °C; < 80 % R.H. non-condensing)
Function Range Accuracy
DC Voltage
Ranges 600 V ± (0.75 % rdg + 2 dgts) Resolution 1 V in 600 V range Input Impedance 10 MW
AC Voltage (40- 450 Hz)
Range 400 V, 600 V ± (1.2 % rdg + 5 dgts) Resolution 0.1 V in 400 V range Input Impedance 10 MW
DC Current
Ranges 400 A, 600 A ± (2 % rdg + 5 dgts) Resolution 0.1 A in 400 A range
AC Current (40-450 Hz)
Ranges 400 A, 600 A ± (2 % rdg + 5 dgts) Resolution 0.1 A in 400 A range
Frequency (Hz), Current and Voltage
Ranges 4 kHz, 20 kHz ± (0.5 % rdg + 5 dgts) Resolution 1 Hz in 4 kHz range Sensitivity 5 A/1 V in 4 kHz range 5 A/5 V in 20 kHz range
Resistance
Range 4 kW ± ( 1.0 % rdg + 5 dgts) Resolution 1 W in 4 kW range Open Circuit Volts 0.5 V DC Max Short Circuit Current 0.8 mA
Diode Test
± (1.0 % rdg + 2 dgts) Resolution 0.001 V Open Circuit Volts 3.2 V DC Max Short Circuit Current 0.8 mA
Continuity
Range Threshold Tone at 40 W ± 15 W Open Circuit Volts 3.2 V DC Max Short Circuit Current 0.8 mA
Peak Hold Measurement AC Voltage (40-450 Hz)
Range 400 V, 600 V ± (1.5 % rdg + 10 dgts) Resolution 0.1 V in 400 V range Input Impedance 10 MW
Peak Hold Measurement AC Current (40-450 Hz)
Range 400 A, 600 A ± (2.0 % rdg + 10 dgts) Resolution 0.1 A in 400 A range
Overload Protection
Voltage 1000 V DC /750 V AC Current 800 Amps Resistance 660 V RMS Diode 660 V RMS
Data Sheet
Amprobe® Test Tools
website: www.Amprobe.com email: info@amprobe.com Everett, WA 98203 Tel: 877-AMPROBE
Amprobe® Test Tools
Amprobe® Test Tools Europe
In den Engematten 14 79286 Glottertal, Germany Tel.: +49 (0) 7684 8009 - 0
©2007 Am probe Test Tools. All rights res erved. 9/20 07 1646618 D-US-N Rev C
www.Amprobe.com
Loading...