Amprobe 34XR-A Specifications

No hassle
1000V
600V
warranty
No waiting.
No shipping charges.
Data Sheet
34XR-A
Digital Multimeter
True RMS digital multimeter with temperature and backlight for contractors and field service technicians.
Frequency to 1 MHz, temperature to 1832 °F, capacitance to 4000 μF
Input warning tone when test
leads are in wrong jack 1000 V/750 V DC/AC
10 Amps AC/DC, fully safety fused
Resistance to 40 M
W
Continuity beeper
Min/Max, Data Hold and Range Lock
Auto power off to save battery
life Separate door for easy battery
and fuse access Magne-Grip™ Holster with
magnetic hanging strap Three-year warranty
34XR-A
(note: $500 MSLP limit)
Amprobe® Test Tools
www.Amprobe.com
34XR-A Digital Multimeter
Data Sheet
General Specifications
Autoranging Display 3-3/4 digit LCD, 3999 counts with 41-segment analog bar graph Display Update Rate 2/sec, nominal Power Battery 9 V NEDA 1604, JIS 006P, IEC 6F22 Battery Life 200 hrs typical (alkaline) frequent use of backlight will decrease battery life Operating Temperature 0 °C to 50 °C at < 70 % R.H.; Storage Temperature -20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter Dimensions 196mm x 92mm x 60mm (7.75” x 3.55” x 2.4”) Weight 400 gr (1 lb) without holster, including battery
Specifications
Function Range Accuracy
DC Voltage
Ranges 400 mV, 4 V, 40 V, 400 V, 1000 V ± (0.5 % rdg + 1 dgt) Resolution 100 μV
AC Voltage (45 Hz to 2 kHz) True RMS
Ranges 400 mV, 4 V, 40 V, 400 V, 750 V Accuracy 400 mV range, 45 to 100 Hz: ± (1.2 % rdg + 8 dgts) 750 V range: 45 to 1 kHz: ± (2.0 % rdg + 8 dgts) All other ranges, 45 to 500 Hz: ± (1.2 % rdg + 8 dgts) All other ranges, 500 to 2 kHz: ± (2.0 % rdg + 8 dgts) Resolution 100 μV
AC coupled True RMS specified from 5 % to 100 % of range
DC Current
Ranges 400 μA, 4 mA, 40 mA, 300 mA, 10 A Accuracy 400 μA to 300 mA ranges: ± (1.0 % rdg + 1 dgt) 10 A range: ± (2.0 % rdg + 3 dgts) Resolution 0.1 μA
AC Current (45 Hz to 1 kHz) True RMS
Ranges 400 μA, 4 mA, 40 mA, 300 mA, 10 A Accuracy 400 μA to 300 mA ranges: ± (1.5 % rdg + 8 dgts) 10 A range: ± (2.5 % rdg + 10 dgts) Resolution 0.1 μA
Resistance
Ranges 400 W, 4 kW, 40 kW, 400 kW, 4 MW, 40 MW Accuracy 400, 4 k, 40 k, 400 k, 4 MW ranges: ± (1.0 % rdg + 4 dgts) 40 MW range: ± (2.0 % rdg + 5 dgts) Resolution 100 mW
Capacitance
Ranges 4 μF, 40 μF, 400 μF, 4000 μF Accuracy 4 μF range: ± (5.0 % rdg + 10 dgts) 40 μF, 400 uF ranges: ± (5.0 % rdg + 5 dgts) 4000 μF range: ± (5.0 % rdg + 15 dgts) Resolution 1 nF
Amprobe® Test Tools
www.Amprobe.com
Loading...