Amprobe 30XR-A Specifications

No hassle
600V
300V
warranty
No waiting.
Data Sheet
30XR-A
Digital Multimeter
Manual ranging digital multimeter with non-contact voltage tester.
Non-contact voltage tester to 600 V AC
Magne-Grip™ Holster with
magnetic hanging strap 600 V AC/DC
10 Amps AC/DC, fully safety fused
Resistance to 20 M
W
Continuity beeper
1.5 V / 9 V battery test under load
Min/Max and Data Hold
Separate door for easy battery and fuse access
One-year warranty
No shipping charges.
(note: $500 MSLP limit)
Amprobe® Test Tools
30XR-A
www.Amprobe.com
30XR-A Digital Multimeter
Data Sheet
General Specifications
Manual Ranging Display: 3-1/2 digit LCD, 1999 counts Display Update Rate: 2.5/sec, nominal Power Battery: 9 V NEDA 1604, JIS 006P, IEC 6F22 Battery Life: 200 hrs typical (carbon-zinc) Operating Temperature: 0 °C to 45 °C at < 70 % R.H. Storage Temperature: -20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter Dimensions: 196 x 92 x 60 mm (7.7” x 3.5” x 2.4”) Weight: 426 gr (0.94 lb) without holster, including battery
Specifications (at 23 °C ± 5 °C, <75 % R.H. non-condensing)
Function Range Accuracy
DC Voltage
Ranges 200 mV, 2 V, 20 V, 200 V, 600 V Accuracy all ranges: ± (1 % rdg + 1 dgt) Resolution 100 μV Input Impedance 10 MW
AC Voltage (45 Hz to 500 Hz)
Ranges 200 mV, 2 V, 20 V, 200 V, 600 V Accuracy all ranges: ± (1.5 % rdg + 4 dgts) Resolution 100 μV Input Impedance 10 MW
DC Current
Ranges 200 μA, 2 mA, 20 mA, 200 mA, 10 A Accuracy 200 μA to 200 mA ranges: ± (1.5 % rdg + 1 dgt) 10 A range: ± (2.0 % rdg + 3 dgts) Resolution 0.1 μA Voltage Burden (Max) 200 μA range: 1 mV/μA 2 mA range: 100 mV/1mA 20 mA range: 13 mV/1 mA 200 mA range: 4.6 mV/1 mA 10A range: 40 mV/1 A
AC Current (45 Hz to 500 Hz)
Ranges 200 μA, 2 mA, 20 mA, 200 mA, 10 A Accuracy 200 μA to 200 mA ranges: ± (2.0 % rdg + 4 dgts) 10A range: ± (2.5 % rdg + 4 dgts) Resolution 0.1 μA Voltage Burden See DC Current
Resistance
Ranges 200 W, 2 kW, 20 kW, 200 kW , 2 MW, 20 MW Accuracy 200 W to 200 kW ranges: ± (1.0 % rdg + 4 dgts) 2 MW range: ± (1.5 % rdg + 4 dgts) 20 MW range: ± (2.0 % rdg + 5 dgts) Resolution 100 mW Open Circuit Voltage 200 W range: 3.0 V DC All other ranges: 0.3V DC typical