Ametek ASC301, ASC-400 Specifications

ASC-400
Advanced Signal Calibrator
User friendly and innovative
Advanced Simplicity
Optimal read out visibility and high accuracy
Large full color display and extremely user friendly interface. The ASC-400 accuracy is designed to meet high demands from modern sensores and transmitters
Input and output
RTD: 16 dierent types, TC: 13 dierent types, Current 0-24 mA DC, Voltage 0-20 VDC, Frequency 0.05 to 10,000 Hz, Pulse train out-put, Resistance 5 to 4000 Ohm
Simultaneoues read-back and fast RTD simulation
Including isolated read-back from device-under-test of mA, V, and pressure. The RTD simulation feature is fast enough to work with pulsed transmitters and PLC´s
Calibrate pressure and temperature
and more… Use the ASC-400 together with JOFRA temperature calibrators, add measurement channels for sensors or temperature switches
Measure temperature
ASC-400 is a portable process signal calibrator that provides the functionality and accuracy you expect from a laboratory calibration system, but compact enough to t into the tool box and be operated with one hand for easy eld calibration.
The ASC-400 is more than just a signal calibrator. Combined with our APM external pressure mod­ules or our dry-block calibrator, it will calibrate pressure and temperature.
The full numerical keypad with a series of function keys and the cursor keys, provide a simple and quick user interface. The new full color display oers the best visibility and overview.
The high accuracy of ASC-400 has not been achieved on account of fragile measure­ments or source circuitries, the ASC-400 has fuse less protection – no lost replacement fuses...
Unique “non-menu” user interface
Easy to use, single layer user interface, no deep menu structure! Operate and set up ASC-400 to perform your tasks, fast and intuitive.
Simultaneous input and output
to calibrate and adjust a transmitter with no need for additional equip­ment.
Temperature reading at reference level
The ASC-400 oers the possibility to charaterize a RTD sensor. This fea­ture is used to add a missing special curve or to characterize a reference RTD. This together with “true ohm” technology, eliminating thermo voltage in the RTD loop, makes ASC-400 a true reference ther­mometer.
Read-back display
The upper half of the full color dis­play is dedicated to the read-back signal from the device-under-test. This input section is electrically isolated from the circuitry. You can also read pressure from the pressure modules in this display section.
Primary display
This part is used for all input or output combinations. The primary dis play plus the read-back display gives a full comprehensive and simultaneous input-output functionality and an excellent overview of the test in progress.
Terminal block
All input and output connectors are placed away from the display and keyboard to give maximum freedom to operate.
We call it the wireless keyboard…
Function keys
The function of the keys is clearly clearly explained in the bottom of the display.
Numeric keyboard
A full numeric keyboard gives you the absolute fastest way to reach
-
your desired set point values.
If you choose a reference RTD from the accurate and stable JOFRA STS temperature sensors, they are delivered with a traceable calibration certicate including the neccessary Callendar-Van Dusen coecients. Enter the gures into the unit and you have a temperature reference. Complement this with a dry-block temperature calibrator and your ASC-400 becomes the heart of your portable calibration lab.
Cursor keys
Set-up navigation, ne tuning of output values, for convenient “analog” feeling.
Fuseless protection
If you by mistake connect the ASC-400 to over voltage, the unit is pro­tected with a fuseless protection feature. This feature protects the unit and prevents expensive repairs and recalibration of the unit.
To avoid injury never connect the unit to the mains supply!
5 “intelligent” memories
Full storage, all settings on both upper & lower channel are stored. Customer dened memory names.
Useful large soft case (Option C)
As an option you can get the ASC-400 delivered with a large padded soft case. The spacey soft case is designed for protection during trans­port. The soft case has separate compartments for the unit, test leads, test hoses, temperature probe, and APM pressure modules. A shoulder strap ensures convenient and safe transportation when climbing lad­ders, etc.
Power Supply / Charger (Option A or B)
As standard the ASC-400 is delivered with 6 AA alkaline batteries.
Additionally two power supply options are available;
Option A, mains adapter, used as battery eliminator to preserve batter­ies in long term workshop testing & calibration.
Option B, like Option A, able batteries, which are
but supplemented with 6 x AA Ni-MH charge-
charged while mounted in the ASC-400.
Online % error calculation, fast and responsive reading, for calibration and adjustment tasks
User congurable scaling, compare values in the same format, easer than ever
Set up span, step size and timing, step and ramp times up to 999 seconds.
Gauge or Absolute pressure? (Option BARO)
The choice is yours!
The BARO option turns any gauge measuring APM into an absolute measuring device.
Accuracy: ± 0.5 mbarA / 0.00725 psiA Range: 700 to 1100 mbarA / 10.153 to 15.954 psiA
Includes all eects of linearity, hysteresis, temperature (-10 to 50°C / 14 to 122°F) and stability for one year.
Please note the BARO option is factory installed.
APM Pressure Modules (Accessory)
When used with APM CPF Series pressure modules the ASC-400 be­comes a true pressure calibrator with features such as; leak test, switch test, scaling and online % error calculations.
Pressure range from vacuum to 1 000 bar / 15 000 psi, accuracies down to
0.025% RDG, fully temperature compensated, and stability for one year.
The modules are engineered for in-plant, eld, or laboratory use. They are ready-to-use with immediate recognition and use of the module once plugged into the calibrator. All units are welded, with a perma­nent lled diaphragm seal. Metal to metal cone seal, and O-ring. CPF adapters to various threading available.
Up to 14 built-in
engineering units
Online % error calculation, fast and responsive reading, for calibration and adjustment tasks
Automatic leak test, adjustable timer and auto­matic calculation to leak rate / minute
Automatic pressure switch test, records automati­cally, open, close and deadband values
Temperature Sensor (Option T)
• Temperature sensor, -40 to 155°C/-40 to 311°F
• Delivered with international traceable calibration certicate and CvD coecients, ready to enter into any ASC
• Sensor dimensions ø 4 x 200 mm + handle
• Calibration points, -40,-20,0,50,100,155°C/-40,-4,32,122,212,311°F
• Calibration accuracy ± 0.030°C/0.054°F
Ambient temperature specications
Operating temperature....................................................................-10 to 50°C / 14 to 122°F
Storage temperature .........................................................................-20 to 60°C / -4 to 140°F
Humidity ....................................................................................0 to 80% R.H. non-condensing
Case protection ........................................................................................................................... IP40
All specs specied at ambient temperature .................................23°C ±5°C / 73°F ±9°F
Outside ambient 23°C ±5°C ............................................................................ ±0.003% rdg/°C
Outside ambient 73°F ±9°F ........................................................................... ±0.0017% rdg/°F
Power specications
Batteries .................................................................................................................. 6 x AA batteries
1.5V AA ..................................... Alkaline (non rechargeable) or AA NiMh (rechargeable)
Mains adapter ....................................................... (option) 9VDC/500mA - 230VAC/115VAC
Low battery warning ...................................................................................................................Yes
Battery lifetime (Alkaline)
Backlight low no, loop power .......................................................................................30 hours
Backlight hight, 12 mA loop ......................................................................................... 13 hours
Charging current (optional charger) ...............................................................................85 mA
Use only NiMH cells with capacity larger than .................................................... 1700 mAh
Display
Display size ....................................................................................................................................2,8”
Resolution ..............................................................................................................320 x 240 pixels
Type ....................................................................................................................................TFT / Color
Update rate.......................................................................................................... 2.5 readings/sec.
RS232 communication interface
Connector .....................................................................................................Mini USB female (B)
Communication rate ............................................................................................ USB 2.0 / ASCII
Switch test output
Maximum current .................................................................................................................... 1 mA
Maximum voltage ................................................................................................................ 24 VDC
Physical specications (LxHxW)
Unit .................................................................................... 220x55x96 mm / 8.66x2.17x3.78 in
Weight incl. batteries .......................................................................................... 584 g / 20.6 oz
Unit in soft case .......................................................... 235x95x115 mm / 9.25x3.74x4.53 in
Weight incl. test leads & test chips .............................................................. 933 g / 32.91oz
Shipping size ........................................................... 275x100x175 mm /
Shipping weight
Miscellaneous
CE - EMC .................................................................................................................EN61326-1:2013
............................................................................................. 1233 g / 43.49 oz
10.83x3.94x6.89 in
Thermocouple
mV
TC mV read -10.000 mV 75.000 mV 0.015% rdg +10µV
TC mV source -10.000 mV 75.000 mV 0.015% rdg +10µV
Maximum current output is 3 mA Output impedance 0.010 ohm.
Thermocouple
Cold junction
CJC compensation 18°C / 64°F 28°C / 83°F 0.2°C / 0.36°F
CJC outside above
Volt V Range Accuracy ±
Read (Isolated) 0.000 V 30.000 V 0.01% rdg +2mV
Read (non-isolated) 0.000 V 20.000 V 0.01% rdg +2mV
Source 0.000 V 20.000 V 0.01% rdg +2mV
Maximum current output in voltage ranges is 3 mA Output impedance 0.050 ohm / Input resistance 1 Mohm
Frequency
Pulse
CPM read 2.0 600.0 0.05% rdg +0.1CPM
Hz read
KHz read 1.000 10.000 0.05% rdg +0.001KHz
CPM source 2.0 600.0 0.05% rdg
Hz source
KHz source 1.000 10.000 0.06% rdg
Pulse (source only) Rate: 1 Hz to 10KHz
Input voltage amplitude range on frequency is 1 to 20 V, Trigger level 0.2 to 10 volt. Minimum pulse with 10 µS. Output amplitude is adjustable from 1 to 20 V and is a square wave with a 50% duty cycle. For output frequency, a slight negative oset of approximately -0.1 V is present to assure zero crossing.
Range Accuracy ±
min max 12 months
Range Accuracy ±
min max 12 months
0.05°C/°C
0.03°F/°F
min max 12 months
Range Accuracy ±
min max 12 months
0.050 10.000 0.05% rdg +0.001Hz
10.000 100.00 0.05% rdg +0.01Hz
100.00 1000.0 0.05% rdg +0.1Hz
1000.0 10000 0.05% rdg +1Hz
0.050 1000.0 0.05% rdg
1000.0 10000 0.06% rdg
1 99999
Ohm Range Accuracy ±
min max 12 months
Ohm read (low) 0.00 400.00 0.015% rdg +0.03 ohm
Ohm read (high) 400.0 4000.0 0.015% rdg +0.3 ohm
Ohm source (low) @ 0.1 to 0.5 mA @ 0.2 to 0.5 mA @ 0.5 to IE max
5.0
5.0
5.0
400.0
400.0
400.0
0.015% rdg +0.10 ohm
0.015% rdg +0.05 ohm
0.015% rdg +0.03 ohm
Ohm source (high) @ 0.05 to 0.1 mA @ 0.01 to IE max
True Ohm Measurement current (pulsed) 0.25 mA. 3W measurement current match 1% Source exitation current IEXI(max) = 2.0 V / R, IEXI must never exceed 3 mA. Pulsed current (source) Unit is compatible with smart transmitters and PLCs with pulse > 5 ms.
400.0
400.0
4000.0
4000.0
0.015% rdg +0.5 ohm
0.015% rdg +0.3 ohm
Current - mA and loop
Range mA ....................................................................................0 to 24 mA
Loop power for transmitters ............................Yes, 24 VDC / ± 10 %
Isolated input ............................................................................................Yes
Current mA Range Accuracy ±
min max 12 months
Read (Isolated) 0.000 mA 24.000 mA 0.010% rdg +2µA
Read (non-isolated) 0.000 mA 24.000 mA 0.010% rdg +2µA
Source 0.000 mA 24.000 mA 0.010% rdg +2µA
Hart resistor 250 ohm (On/O in software). Maximum loop resistance source (Hart on/ Hart o) 700 ohm / 950 ohm. mA source voltage input range (external power/HART resistor o) 1V ‐ 30V
Thermocouple - TC
TC types ..............................................................................................B/BP/C/E/J/K/L/N/R/S/T/U/XK
Cold junction compensation ON/OFF control .........................................................................Yes
Thermo
couple
Type
B 0,1 0,1
BP
C
E 0,1 0,01
J 0,1 0,01
K 0,1 0,01
L 0,1 0,01
Resolution Range Accuracy
Source Measure Min. °C Max. °C Min. °F Max. °F °C °F
0,1 0,1
0,1 0,1
250 300 482 572 4,02 7,24
300 400 572 752 3,36 6,05
400 600 752 1112 2,47 4,45
600 800 1112 1472 1,60 2,88
800 1000 1472 1832 1,39 2,51
1000 1820 1832 3308 1,07 1,93
0 1200 32 2192 0,89 1,61
1200 2000 2192 3632 1,39 2,51
2000 2500 3632 4532 1,96 3,53
0 200 32 392 0,75 1,35
200 800 392 1472 0,64 1,16
800 1200 1472 2192 0,78 1,41
1200 1600 2192 2912 0,97 1,75
1600 2000 2912 3632 1,24 2,24
2000 2316 3632 4200,8 1,70 3,06
-200 -100 -328 -148 0,46 0,83
-100 0 -148 32 0,26 0,47
0 400 32 752 0,20 0,36
400 1000 752 1832 0,30 0,54
-210 -150 -346 -238 0,59 1,07
-150 0 -238 32 0,34 0,62
0 660 32 1220 0,26 0,47
660 1200 1220 2192 0,36 0,65
-200 -100 -328 -148 0,72 1,30
-100 0 -148 32 0,35 0,63
0 400 32 752 0,30 0,54
400 800 752 1472 0,37 0,67
800 1000 1472 1832 0,42 0,76
1000 1372 1832 2501,6 0,53 0,96
-200 -100 -328 -148 0,37 0,67
-100 900 -148 1652 0,26 0,47
Thermo
couple
Type
N 0,1 0,01
R 0,1 0,1
S 0,1 0,1
T 0,1 0,01
U 0,1 0,01
XK 0,1 0,01
Resolution Range Accuracy
Source Measure Min. °C Max. °C Min. °F Min. °F [°C °F
-200 -100 -328 -148 1,08 1,95
-100 0 -148 32 0,50 0,90
0 1000 32 1832 0,41 0,74
1000 1300 1832 2372 0,49 0,89
-50 0 -58 32 2,72 4,90
0 200 32 392 1,89 3,41
200 660 392 1220 1,17 2,11
660 1600 1220 2912 0,95 1,71
1600 1768,1 2912 3214,58 1,07 1,93
-50 0 -58 32 2,51 4,52
0 200 32 392 1,86 3,35
200 400 392 752 1,21 2,18
400 1600 752 2912 1,10 1,98
1600 1768,1 2912 3214,58 1,23 2,22
-200 -100 -328 -148 0,70 1,26
-100 0 -148 32 0,38 0,69
0 200 32 392 0,26 0,47
200 400 392 752 0,22 0,40
-200 0 -328 32 0,54 0,98
0 600 32 1112 0,26 0,47
-200 -100 -328 -148 0,43 0,78
-100 0 -148 32 0,23 0,42
0 400 32 752 0,18 0,33
400 800 752 1472 0,24 0,44
Does not include thermocouple wire error and CJC.
Resistance - RTD
RTD types ............................Pt10/50/100/200/400/500/1000, Cu10/50/100, Ni120, YSI400
Response time .........................................................................................................Less than 5 mSec.
Connection .....................................................................................................................2, 3 and 4-wire
RTD
Type
Pt10(90)385 0,1 0,1
Pt50(90)385 0,1 0,01
Pt100(90)385 0,1 0,01
Pt200(90)385 0,1 0,01
Pt400(90)385 0,1 0,01
Pt500(90)385 0,1 0,01
Pt1000(90)385 0,1 0,01
Resolution Range Accuracy
Source Measure Min. °C Max. °C Min. °F Max. °F °C °F
-200 100 -328 212 0,85 1,53
100 400 212 752 0,98 1,77
400 660 752 1220 1,12 2,02
660 850 1220 1562 1,23 2,22
-200 100 -328 212 0,22 0,40
100 400 212 752 0,29 0,53
400 660 752 1220 0,35 0,63
660 850 1220 1562 0,41 0,74
-200 100 -328 212 0,12 0,22
100 400 212 752 0,20 0,36
400 660 752 1220 0,26 0,47
660 850 1220 1562 0,31 0,56
-200 265 -328 509 0,14 0,26
265 400 509 752 0,55 0,99
400 660 752 1220 0,64 1,16
660 850 1220 1562 0,72 1,30
-200 0 -328 32 0,09 0,17
0 400 32 752 0,34 0,62
400 660 752 1220 0,41 0,74
660 850 1220 1562 0,47 0,85
-200 100 -328 212 0,22 0,40
100 400 212 752 0,29 0,53
400 660 752 1220 0,35 0,63
660 850 1220 1562 0,41 0,74
-200 100 -328 212 0,14 0,26
100 400 212 752 0,20 0,36
400 660 752 1220 0,26 0,47
660 850 1220 1562 0,31 0,56
RTD
Type
P50(90)391 0,1 0,01
P100(90)391 0,1 0,1
P100(90)392 0,1 0,01
M10(90)427 0,1 0,1 -200 260 -328 500 0,85 1,53
M50(90)428 0,1 0,01 -200 200 -328 392 0,21 0,38
M100(90)428 0,1 0,01 -200 200 -328 392 0,14 0,26
H100(90)617 0,1 0,01 -60 180 -76 356 0,11 0,20
H120(90)672 0,1 0,01 -80 260 -112 500 0,10 0,18
P100(90)JIS 0,1 0,01
YSI-400 0,1 0,01 15 150 59 302 0,02 0,04
Resolution Range Accuracy
Source Measure Min. °C Max. °C Min. °F Max. °F °C °F
-200 100 -328 212 0,21 0,38
100 400 212 752 0,28 0,51
400 660 752 1220 0,35 0,63
660 850 1220 1562 0,40 0,72
850 1100 1562 2012 0,49 0,89
-200 100 -328 212 0,15 0,27
100 400 212 752 0,20 0,36
400 660 752 1220 0,26 0,47
660 850 1220 1562 0,31 0,56
850 1100 1562 2012 1,38 2,49
-260 100 -436 212 0,13 0,24
100 400 212 752 0,19 0,35
400 630 752 1166 0,25 0,45
-200 100 -328 212 0,14 0,26
100 500 212 932 0,22 0,40
Read accuracy is based on 4 wire input.
Source accuracy in terminals 2 wire source.
Pressure modules, Barometric option (BARO) and APM CPF
APM CPF Type (s)
Bar MPa psi
3 bar 300 kPa 30 psi
10 bar 1 MPa 100 psi
30 bar 3 MPa 300 psi
100 bar 10 Mpa 1 kpsi
300 bar 30 MPa 3 kpsi
700 bar 70 MPa 10 kpsi
1000 bar 100 MPa 15 kpsi
Absolute pressure APM CPF with ASC-400 BARO option / 12 month Accuracy ±
3 bar APM CPF Accuracy ± 300 kpA APM CPF Accuracy ± 30 psi APM CPF Accuracy ±
0.0138 to 1 barA 0.0008 barA 1.38 to 100 kPaA 0.08 kPaA 0.2 to 14.5 psiA 0.011 psiA
1 to 4 barA 0.025% RDG + 0.0003 barA 100 to 400 kPaA 0.025% RDG + 0.03 kPaA 14.5 to 44.5 psiA 0.025% RDG + 0.003 psiA
10 bar APM CPF Accuracy ± 1 MPa APM CPF Accuracy ± 100 psi APM CPF Accuracy ±
0.0138 to 1 barA 0.0008 barA 0.00138 to 0.1 MPaA 0.00008 MPaA 0.2 to 14.5 psiA 0.011 psiA
1 to 4 barA 0.001 barA 0.1 to 0.4 MPaA 0.0001 MPaA 14.5 to 44.5 psiA 0.011 psiA
4 barA to 11 barA 0.025% RDG 0.4 MPaA to 1.1 MPaA 0.025% RDG 44.5 to 114.5 psiA 0.025% RDG
30 bar APM CPF Accuracy ± 3 MPa APM CPF Accuracy ± 100 psi APM CPF Accuracy ±
0.014 to 1 barA 0.001 barA 0.0014 to 0.1 MPaA 0.001 MPaA 0.2 to 14.5 psiA 0.01 psiA
1 to 10 barA 0.003 barA 0.1 to 1.0 MPaA 0.003 MPaA 14.5 to 104.5 psiA 0.03 psiA
10 barA to 31 barA 0.025% RDG 1.0 MPaA to 3.1 MPaA 0.025% RDG 104.5 to 314.5 psiA 0.025% RDG
-1 3
-1 10
-1 30
0 100
0 300
0 700
0 1000
Gauge
-0.099 0.300
-14.5 30
-0.099 1.0
-14.5 100
-0.099 3.0
-14.5 300
0 10.0
0 1 000
0 30.0
0 3 000
0 70.0
0 10 000
0 100.0
0 15 000
12 month
Accuracy ±
0 to 30 % range
0.0075% FS 0.025% RDG 0.06% FS + 1 LSD
0.0075% FS 0.025% RDG 0.06% FS + 1 LSD
0.0075% FS 0.025% RDG 0.06% FS + 1 LSD
0.015% FS 0.05% RDG N/A
0.015% FS 0.05% RDG N/A
0.03% FS 0.1% RDG N/A
0.03% FS 0.1% RDG N/A
12 month
Accuracy ±
30 to 110% range
12 month
Accuracy ± Vacu-
um % FS
Specied temperature range -10 to 50°C / 14 to 122°F (APM CPF & BARO option) Vacuum FS, 1 bar / 100 kPA / 14.5 psi. F.S. (full scale) is the numerical value of the positive pressure range. Accuracy includes hysteresis, nonlinearity, repeatability and refer­ence standard uncertainty, 1 Year typical longterm stability, operated inside the rated temperature span and pressure range. Requiring frequently zeroing.
Standard delivery
ASC-400 unit
Battery set (6 x AA)
Electronic Manual (USB)
2 sets of test leads & test clips (black & red)
Handy soft case, with pocket for the test leads and an opening in the top to provide easy access to the test terminals
Full international traceable calibration certicate
Ordering
Order No. Description
ASC-400 Multi-function Signal Calibrator
BARO Barometric module to absolute pressure mode (optional)
Certicate
F Traceable Certicate to International Standards
H Accredited Certicate - ISO17025 (optional)
Accessories (Optional)
A External Power Supply
B Power Supply /Charger plus 6 x Ni-MH rechargeable AA
C Large padded soft case with shoulder strap
T Temperature Sensor: Pt100 Probe incl. traceable certicate
T2 Temperature Sensor: Pt100 Probe, -40 to 150 °C incl. accredited certicate – ISO17025
T3 Temperature Sensor: STS050 Probe, -40 to 400 °C incl. accredited certicate – ISO17025 *
*
ASC-400 BARO F C ASC-400 with barometric module, traceable certicate and
soft case
* Option T2 & T3 are delivered with a system temperature calibration certicate, combining ASC-400 and temperature sensor.
We enter the sensor correction factors (CvD) to ASC-400.
Accessories
121983 Extension Cable for Type K - 5 m
122523 Extension Cable for Type N - 5 m
120519 Thermocouple Male Plug - Type Cu-Cu - White
120518 Thermocouple Male Plug - Type R / S - Green
120517 Thermocouple Male Plug - Type K - Yellow
120516 Thermocouple Male Plug - Type J - Black
120515 Thermocouple Male Plug - Type T - Blue
120514 Thermocouple Male Plug - Type N - Orange
2206011 Thermocouple plug + K wire + alligator
2206012 Thermocouple plug + T wire + alligator
124720 External Power Supply / Charger 9VDC/200mA - 230VAC/115VAC
128859 6x 1.5V AA Ni-MH rechargeable batteries
65-PT100-LB-CABLE - Cable 2 m (6.6 ft.) with LEMO/Banana connectors
XXXX Various APM CPF Series - Advanced Pressure Modules
AMETEK Sensors, Test & Calibration
Gydevang 32 • 3450 Alleroed • Denmark • Tel +45 4816 8000 • ametekcalibration.com
© 2018 AMETEK Inc. Pub code: SS-ASC400 Issue: 1504