pressure
» Accuracies to 0.025% RDG + 0.01 FS
Performance to meet almost any calibration and measurement task.
» % RDG specification
Wide range of pressure ranges, from 25
mbar to 700 bar (0.4 to 10,000 psi) Full
Scale.
» More pressure types
Gauge, differential, absolute, and vacuum
pressure modules available.
» Rugged construction
Cast aluminium housing. Engineered for
rough field use, almost unbreakable.
Advanced Pressure Module
APM Mk.II
» Plug and pressurize
JOFRA calibrators recognize the modules
for ease of use, just plug it in…
» Self contained intelligent module
Calibration data are stored and processed
inside the APM. Enabling use of the APM
with any JOFRA calibrator, without initial
calibration of the “system”. Calibration and
traceability follows the module!
» Compatible with your JOFRA
The APM Mk.II modules are compatible
with your AMC900, AMC910, ASC300,
ASC301, APC or HPC500, HPC502 or
HPC600 calibrators.
The JOFRA APM Mk.II 2nd generation of pressure modules offers the
functionality and flexibility needed to perform pressure calibrations with
your multi-purpose or multifunction signal calibrator.
Expand the ranges to meet all of your pressure calibration applications
by using APM modules.
The APM series of pressure modules are compatible with current
AMC910, ASC300, ASC301 or HPC calibrators, and the former AMC900
and APC calibrators. The pressure model span across a wide pressure
range and are available for all pressure types. From vacuum to absolute
pressure, AMETEK covers any application with the pressure modules to
meet your calibration needs.
These rugged modules are engineered for in-plant, field, or laboratory
use. They are ready-to-use with the JOFRA calibrators and the protocol
allows for immediate recognition and use of the module once it is connected to the calibrator.
The APM Mk.II is temperature compensated from 0 to 50°C / 32 to 122°F
for on-site operation. It is a truly superior pressure module for laboratory
and field use, bringing laboratory accuracy into the field.
When combined with the calibrators and pump systems these modules
makes powerful calibration tools. And, it is always possible to add modules as the calibration needs changes.
ISO 9001 Manufacturer
Specification Sheet
SS-APM Mk.II
FUNCTIONAL SPECIFICATIONS
Pressure: gauge / compound ranges
bar ................................................................. -0.96 to 1 or 2
bar ......................................................... -0.82 to 7, 20 or 35
psi ................................................................. -14 to 15 or 30
psi ..................................................... -12 to 100, 300 or 500
Pressure: gauge
bar ................ .1, 2, 7, 20, 35, 70, 100, 200, 350, 400 or 700
psi ................................ 15, 30, 100, 300, 500, 1,000, 1,500,
.................................................. 3,000, 5,000, 6,000, 10,000
Pressure: absolute ranges
bar ..............................................................0.025 to 1.1 or 2
bar ...................................................... 0.07 to 1.1, 3.5, 7, 20
psi ................................................................0.35 to 16 or 30
psi ........................................................ 1 to 16, 50, 100, 300
Pressure: differential ranges
mbar ..........................................................±25, ±70 or ±350
psi .................................................................±0.35, ±1 or ±5
Engineering units
User selectable .................................. Host calibrators spec.
(bar, mbar, MPa, kPa, inHg@0°C, mmHg@0°C, kg/cm2, mmH2O@4˚C,
mmH2O@20˚C, psi, inH2O@4˚C, inH2O@20˚C, inH2O@60˚F, cmH2O@4˚C,
cmH2O@20˚C)
Pressure accuracy ambient temp. (18 to 28°C/65 to 82°F)
±25 mbar / 0.35 psi ...........................................±0.10% F.S.
±70, 350 mbar / 1, 5 psi ....................................±0.05% F.S.
700 bar / 10k psi ................... ±0.025% RDG + 0.015% F.S.
All other pressure ranges......... ±0.025% RDG + 0.01% F.S.
Vacuum ............................................................±0.025% F.S.
F.S. (full scale) is the numerical value of the positive pressure range.
Accuracy includes hysteresis, nonlinearity, repeatability and reference
standard uncertainty, 1 Year typical long-term stability, operated inside the
rated temperature span and pressure range.
For optimal performance “zero” the unit for gauge/differential measure-
ments or enter the reference pressure for absolute measurements.
Pressure accuracy ambient temp. (0 to 50°C / 32 to 122°F)
±25 mbar / 0.35 psi ...........................................±0.15% F.S.
±70, 350 mbar / 1, 5 psi ....................................±0.10% F.S.
700 bar / 10k psi ..................... ±0.04% RDG + 0.015% F.S.
All other pressure ranges........... ±0.04% RDG + 0.01% F.S.
Vacuum ..............................................................±0.05% F.S.
F.S. (full scale) is the numerical value of the positive pressure range.
Temperature effect -10 to 0°C / 14 to 32°F ±0.005% F.S./°C.
Accuracy includes hysteresis, nonlinearity, repeatability and reference
standard uncertainty, 1 Year typical long-term stability, operated inside the
rated temperature span and pressure range.
For optimal performance “zero” the unit for gauge/differential measure-
ments or enter the reference pressure for absolute measurements.
RS232 communication interface
Connector .......................................................... 5 pin LEMO
Serial ............ 0-5 VDC, 9600 baud, 8 data, no parity, 1 stop
Protocol ...................................... ASCII command language
JOFRA calibrator compability
JOFRA AMC900* ........................................ Signal calibrator
JOFRA AMC910 .................... Multifunction signal calibrator
ASC300 ...........................Handheld multifunction calibrator
ASC301 .......................... Advanced multifunction calibrator
APC series* ........................................... Pressure calibrators
HPC500 series ...................................... Pressure calibrators
HPC502 series ...................................... Pressure calibrators
HPC600 series .........Pressure calibrators w/electrical pump
* Obsolete product
Media compatibility
Nickel plated brass or 316 stainless steel - see pressure
table on page 3.
Environmental
Operating temperature ...................-10 to 50°C/14 to 122°F
Storage temperature ...................... -20 to 60°C/-4 to 140°F
Ingress protection rating ...............................................IP54
Pressure connection
All calibrators ..............................................1/8” BSP female
Adapters to 1/4” NPT male and 1/4” BSP female are included as standard.
Pressure overload
Overload alarm .......... “OL” in display at approx. +20% F.S.
Power supply
Power supply .................................................Host calibrator
Instrument dimensions (LxWxH)
APM Mk.II .............................76x45x76 mm / 3.0x1.8x3.0 in
APM Mk.II weight (incl. cable) ...................... 370 g / 13.1 oz
APM Mk.II shipping ..........245x180x80 mm / 9.6x7.1x3.1 in
APM Mk.II weight, shipping.......................... 670 g / 23.7 oz
Miscellaneous
Compliance: EN 61326 : 2006 & CISPR 11, Edition 5.0 2009 Class “B”.
Output
Pressure resolution ....................................................5 digits
Display update ..........................................Host dependable
2 www.jofra.com Advanced Pressure Module • APM Mk.II
Differential pressure, ranges & acc.
Model APM 025MD APM 070MD APM 350MD
Range (bar) ±25 mbar ±70 mbar ±350 mbar
Range (psi) 0.36 1 5
Sensor type non-isolated non-isolated non-isolated
Pressure type differential differential differential
Accuracy,
18 to 28°C / 65 to 82°F ±0.10% F.S. ±0.05% F.S. ±0.05% F.S.
Accuracy,
0 to 50°C / 32 to 122°F ±0.15% F.S. ±0.10% F.S. ±0.10% F.S.
Compound pressure, ranges & acc.
Model APM 001C APM 002C APM 007C APM 020C APM 035C
Range (bar) -0.96 to 1 -0.96 to 2 -0.82 to 7 -0.82 to 20 -0.82 to 35
Range (psi) -14 to 15 -14 to 30 -12 to 100 -12 to 300 -12 to 500
Sensor type non-isolated non-isolated isolated isolated isolated
Pressure type compound compound compound compound compound
Accuracy,
18 to 28°C / 65 to 82°F
Accuracy,
0 to 50°C / 32 to 122°F
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
Absolute pressure, ranges & acc.
Model APM 001A APM 002A APM 003A APM 007A APM 020A
Range (bar) 0.025 to 1.1 0.025 to 2 0.070 to 3.5 0.070 to 7 0.070 to 20
Range (psi) 0.35 to 16 0.35 to 30 1 to 50 1 to 100 1 to 300
Sensor type non-isolated non-isolated isolated isolated isolated
Pressure type absolute absolute absolute absolute absolute
Accuracy,
18 to 28°C / 65 to 82°F
Accuracy,
0 to 50°C / 32 to 122°F
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
Gauge pressure, ranges & acc.
Model APM 001G APM 002G APM 007G APM 020G APM 035G APM 070G
Range (bar) 1 2 7 20 35 70
Range (psi) 15 30 100 300 500 1,000
Sensor type isolated isolated isolated isolated isolated isolated
Pressure type gauge gauge gauge gauge gauge gauge
Accuracy,
18 to 28°C / 65 to 82°F
Accuracy,
0 to 50°C / 32 to 122°F
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
Model APM 100G APM 200G APM 350G APM 400G APM 700G
Range (bar) 100 200 350 400 700
Range (psi) 1,500 3,000 5,000 6,000 10,000
Sensor type isolated isolated isolated isolated isolated
Pressure type gauge gauge gauge gauge gauge
Accuracy,
18 to 28°C / 65 to 82°F
Accuracy,
0 to 50°C / 32 to 122°F
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
+0.01%F.S.
±0.04%RDG
+0.01%F.S.
±0.025%RDG
+0.015%F.S.
±0.04%RDG
+0.015%F.S.
www.jofra.com 3APM Mk.II • Advanced Pressure Module
STANDARD DELIVERY
• Pressure Module
• Adapter fitting for NPT and BSP threads
• Communication cable (integrated)
• NIST traceable calibration certificate in Bar, Pa and PSi
ACCESSORIES
Number Description
SPK-APM-003 APM Mk.II Communication kit for PC.
USB to female 5 pin Lemo will supply power for APM
Mk.II as well.
Fittings to connect APM Mk.II modules with pump systems
System A
SPK-HPC-008 Fitting APM Mk.II to T-960/T-970 pump
System B
SPK-HPC-008 Fitting APM Mk.II to T-965/T-975 pump
System C
Included fitting Fitting APM Mk.II to T-620 / T-620H pump
System D
SPK-HPC-004 Fitting APM Mk.II to P016 & P017 pump
System E
SPK-HPC-004 Fitting APM Mk.II to P014 pump
System F
Included fitting Fitting APM Mk.II to T-1 pump
A business unit of AMETEK Measurement & Calibration
AMETEK Test & Calibration Instruments
Technologies Division offering the following industry
leading brands for test and calibration instrumentation.
JOFRA Calibration Instruments
Temperature Calibrators
Portable dry-block calibrators, precision thermometers
and liquid baths. Temperature ranges from
-90°C(-130°F) to 1205°C(2200°F). Temperature sensors
for industrial and marine use.
Pressure Calibrators
Convenient electronic systems ranging from -25 mbar to
1000 bar - fully temperature-compensated for problem-
free and accurate field use.
Signal Instruments
Process signal measurement and simulation for easy
control loop calibration and measurement tasks.
M&G Pressure Testers & Pumps
Pneumatic floating-ball or hydraulic piston dead weight
testers with accuracies to 0.015% of reading. Pressure
generators delivering up to 1,000 bar.
Lloyd Instruments
Materials testing machines and software from Lloyd
Instruments guarantees expert materials testing
solutions. The comprehensive program also covers
Texture Analysers to perform rapid, general food testing
and detailed texture analysis on a diverse range of foods
and cosmetics.
Davenport Polymer Test Equipment
Allows measurement and characterization of moisture-
sensitive PET polymers and polymer density.
Chatillon Force Measurement
The hand held force gauges and motorized testers
have earned their reputation for quality, reliabilit y and
accuracy and they represent the de facto standard for
force measurement.
Newage Testing Instruments
Hardness testers, durometers, optical systems and
software for data acquisition and analysis.
UK
AMETEK Calibration Instruments
Tel +44 (0)1243 833 302
jofra@ametek.co.uk
France
AMETEK S.A.S.
Tel +33 (0)1 30 68 89 40
general.lloyd-instruments@ametek.fr
Germany
AMETEK GmbH
Tel +49 (0)2159 9136 510
info.mct-de@ametek.de
Information in this document is subject to change without notice. ©2012, by AMETEK, Inc., www.ametek.com. All rights reserved.
Denmark
AMETEK Denmark
Tel +45 4816 8000
jofra@ametek.com
USA
AMETEK M ansfield & Green
Tel +1 (800) 527 9999
cal.info@ametek.com
India
AMETEK Instruments India Pvt Ltd.
Tel +91 22 2836 4750
jofra@ametek.com
4 www.jofra.com
www.jofra.com
Singapore
AMETEK Singapore Pte Ltd
Tel +65 6484 2388
jofra@ametek.com
China
AMETEK Inc. - Shanghai
Tel +86 21 5868 5111
AMETEK Inc. - Beijing
Tel +86 10 8526 2111
AMETEK Inc. - Guangzhou
Tel +86 20 8363 4768
jofra.sales@ametek.com.cn
Pub code SS-APM_MkII Issue 1203