Provide mating connector information for the ReFlex Power™ AC Power Supply (A CPS) module.
Figure 1. ACPS Front Panel View
MATING CONNECTOR KIT
ACPS Mating Connector Kit - AMETEK Part No. 5380272-01, mates with RFP-A301K-875-XXXX and RFP-A305K-875-XXXX,
and includes the following for both Interface an d DC output connectors:
RECOMMENDED TOOLS (NOT INCLUDED WITH MATING CONNECTOR KIT)
Hand crimp: Positronic Industries P/N 95 07-0-0-0
Pneumatic crimp: Positronic Industries P/N 9550-1-0.
Insertion/extraction: Positronic Industries P /N M81969/1-02
9250 Brown Deer Road, Sa n Diego CA 92121 • Tel: 858-4 50-008 5 • Fax: 858-458- 0267 • e mail: sal es@progra mmablep ower.com • Web: www.programm ablepow er.com
Document No. W380272-01 Rev D • 1/23/2009
Pins A1 through A6 insertion/extraction: Positronic Industries P/N 4311-0-0 -0
INTERFACE CONNECTOR
External isolated digital and analog cont rol interface.
Connector: Positronic Industries P/N SD9M1000Z, AMETEK P/N 856-214-09
Crimp contacts: Positronic Industries P/N MC75 20D (initially suppli ed with conne ctor)
Backshell: Positronic Industries P/N D9000Z00, AMETEK P/N 856-247-10
Wire size: Maximum gauge 20 AWG (recommended)
Maximum length 10 meters (can be extended subject to the environ ment, cable type, and interface circuit s).
INTERFACE PINOUT
Figure 2. Interface Connector, Front Panel View, and Interface Connector Wiring Diagram
PinName Function Signal Level
1 ENA1 Input: module output enable TTL logic level
6 ENA-RTN1 Input: return for ENA signal; connected to Pin-7/8 Signal common
2 Reserved
7 Reserved
3 Reserved
8 Reserved
4 Reserved
9 Reserved
5 CHAS-GND Shield ground Chassis ground
1
Enable signal is internally pulled up to +5 V with a 10 K resistor. To enable the module, the signal is pulled low (<= 0.5 V) with respect to the ENA RTN
signal; this may also be accomplished by shorting Pin 1 to Pin 6.
9250 Brown Deer Road, Sa n Diego CA 92121 • Tel: 858-4 50-008 5 • Fax: 858-458- 0267 • e mail: sal es@progra mmablep ower.com • Web: www.programm ablepow er.com
Pins A1 through A4 maximum gauge 20 AWG (recommended); maximum length 15 ft (Voltage drop at full-rated current ≅1.1V)
Pins A5, A6 maximum gauge 20 AWG (recommended); maximum length 15 ft
Pins 2, 6 maximum gauge 20 AWG (recommended); maximum length 15 ft (Voltage drop at full-rated c urrent ≅0.6V)
AC OUTPUT PINOUT
AC Output
Out
Out_Rtn
Out
Out_Rtn
Sense
Sense_Rtn
Aux
Aux_Rtn
Chas Gnd
N/U
N/U
N/U
N/U
Figure 3. AC Output Connector, Front Panel View, and AC Output Connector Wiring Diagram
PinName Function Signal Level
A1 Out Output: module output source; connected to A3
A2 Out_Rtn Output: return for output source, OUT; connected to A4
A3 Out Output: module output source; connected to A1
A4 Out_Rtn Output: return for output source, OUT; connected to A2
A5 Sense Input: remote sense connection for OUT
A6 Sense_Rtn Input: remote sense connection for OUT-RTN
9250 Brown Deer Road, Sa n Diego CA 92121 • Tel: 858-4 50-008 5 • Fax: 858-458- 0267 • e mail: sal es@progra mmablep ower.com • Web: www.programm ablepow er.com
• AMETEK P/N 5380450-03, ACPS Module, Right Angle, 9ft. Unterminated AC Output Cable Assembly