Installation
Instructions
DECK-MOUNT BATH FILLER TRIM KIT
with EverClean™ Finish
Congratulations on purchasing your American Standard
faucet with EverClean finish found only on American
Standard faucets.
EverClean Finish
• One wipe effortlessly removes spots
• Eliminates the need for cleaners and scrubbing
• Permanent surface protectant remains beautiful
for the life of the faucet
• EverClean™ available on: Polished Chrome, Satin Nickel,
Stainless Steel, Polished Brass (or any combination of these finishes)
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
T980.702
T980.712
T980.722
T980.732
Certified to comply with ANSI A112.18.1
U.S. Patent No. D403,750
M968655 Rev. 1.1
Required tools
Phillips Screwdriver
Channel Locks
SPOUT INSTALLATION
1
Complete FINISHED DECK before trim installation.
Turn off the water supplies.
Remove the GUARDS (1) from the VALVES (2). Remove the
GUARD (3) and 1/4" PLUG (4) from the SPOUT SHANK (5).
The SPOUT SHANK (5) height should be 1" to 1-1/2" above the
FINISHED DECK. Cut the SPOUT SHANK (5) if necessary. Remove all
burrs and bevel the end of the shank. Failure to do so may
damage the SPOUT O-ring during installation and cause water
leakage.
Drill a 3/16" hole in the finished deck. See TEMPLATE for location.
3/16" DRILLED
HOLE
Screwdriver
Hacksaw
SPOUT
SHANK
Drill with
3/16” bit
11
FINISHED
DECK
10
4
5
1
2
19.8mm
(23/32")
3
1
2
8.4mm
(21/64")
3/16" DIA. HOLE
REMOVE ALL
BURRS AND
BEVEL
1"- 1-1/2"
18.6mm DIA.
(47/64")
SPOUT SHANK
TEMPLATE FOR
SPOUT ROLL
FRONT
6
8
PIN LOCATION
13
16
7
Lubricate the SPOUT ADAPTER O-RING (6) and
SPOUT O-RING (7).
Push SPOUT ADAPTER (8) on SPOUT SHANK (9)
and align slot in SPOUT ADAPTER (8) with 3/16"
drilled hole.
Tighten SPOUT ADAPTER SET SCREW (10) securely
with 4mm HEX KEY (11).
Remove the PLUG BUTTON (12) from the SPOUT (13).
Position the RUBBER RING (14) in the groove in
the base of the SPOUT (13). Push the SPOUT (13) down
onto the SPOUT ADAPTER (8) and tighten the
SET SCREW (15) securely with the 5mm HEX KEY (16).
Insert the PLUG BUTTON (12) into the SPOUT (13).
FINISHED
DECK
GROOVE
13
9
3/16" DRILLED
HOLE
14
12
15
SPOUT
O-RING
8
2
VALVE TRIM
4
3
Place the ESCUTCHEON SEALS (1) over the VALVE BODIES (2).
Thread the VALVE ESCUTCHEONS (3) into the VALVE BODIES (2).
Align the HANDLE STEM (4) with the SLEEVE (5) as necessary.
Thread the VALVE ESCUTCHEON (3) into the BODIES (2) until the
ESCUTCHEON (3) contacts the finished deck.
INSTALL HANDLES
3
LEVER HANDLE
Turn VALVE into OFF position.
Push ADAPTER (1) into HANDLE (2)
in a way that the male square on the
ADAPTER (1) fits in the female square
of the HANDLE (2).
Push HANDLE (2) and ADAPTER (1)
onto VALVE STEM (4).
Check alignment, if not satisfactory aligned;
Push out ADAPTER (1) carefully.
Turn ADAPTER (1) either 45˚ or 90˚
so that male square on ADAPTER (1)
catches different female square in
HANDLE BASE (2).
Assemble and tighten HANDLE
SCREW (3).
1
5
2
CROSS HANDLE
Turn VALVE into OFF position.
5
3
2
Push ADAPTER (1) into
HANDLE BASE (2).
Push HANDLE BASE (2)
and ADAPTER (1) onto
VALVE STEM (3).
Push CROSS (4) onto
ADAPTER (1).
6
4
5
2
1
1
Assemble and tighten
HANDLE SCREW (5).
4
Push INDEX CAP (6) in
top of HANDLE (4).
3
Push INDEX CAP (5) in top of HANDLE (2).
TESTING
4
Turn the HOT HANDLE (1) clockwise and the
COLD HANDLE (2) counterclockwise to the
off position.
Unscrew and remove the SPOUT END (3).
Slowly turn on the water supplies.
Operate the HANDLES (1, 2) to flush water
lines thoroughly. Check SPOUT (4) connection
for leakage.
Turn the Handles off. Replace the SPOUT
END (3).
1
4
SERVICE
5
2
3
To change the direction of handle rotation
Turn off the water supplies
Turn HANDLE (1) to the off position.
Remove the INDEX CAP (2) and the HANDLE
SCREW (3). Pull the HANDLE BASE (4) off and
remove ADAPTER (5).
Unscrew the VALVE ESCUTCHEON (6).
Unscrew the VALVE LOCK NUT (7) and
remove. A 17mm deep socket is required.
Remove the CARTRIDGE (8) by
pulling up on the SLEEVE (9).
Remove the SCREW (10)
from the CARTRIDGE (8).
Remove the SPRING CLIP (11).
Remove the STOP WASHER (12).
Turn it 90˚ and replace.
Replace the SPRING CLIP (11).
Reverse the above steps to
reassembly the components.
If the spout drips, operate the handles several
times from the off to the on position. Do not
force - the handles only turn 90˚
12
90$
11
2
3
4
5
6
7
10
9
8
1
EverClean™ Finish Care Instructions
4
American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean
water may also be used, if desired. No additional cleaning products are required.
DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.
M968655 Rev. 1.1