Installation
Instructions
4205.104
SINGLE CONTROL
KITCHEN PULL-OUT FAUCET
Thank you for selecting American-Standard...
the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
RECOMMENDED TOOLS
Certified to comply with ANSI A112.18.1M
M968473 REV 1.8
Regular Screwdriver
INSTALL FAUCET WITH OR WITHOUT DECK ESCUTCHEON
1
CAUTION
(A) Installation with ESCUTCHEON (1). Apply a bead of putty to bottom edge of ESCUTCHEON with PUTTY PLATE (1).
Insert supply HOSES (2) and SHANK (3) through hole of ESCUTCHEON with PUTTY PLATE (1) and mounting surface.
Follow mounting instructions below to secure faucet to mounting surface.
(B) Installation less ESCUTCHEON (1). Discard ESCUTCHEON with PUTTY PLATE (1). Insert supply HOSES (2) and
SHANK (3) through mounting hole and seat SPOUT BASE onto sink or mounting surface. Do not use putty.
Insert HOSES (2) through RUBBER WASHER (4), BRASS WASHER (5), and threaded LOCKNUT (6).
Assemble RUBBER WASHER (4), BRASS WASHER (5), and threaded LOCKNUT (6) onto SHANK (3) from underside
of sink or mounting surface. Hand tighten LOCKNUT (6) and check that rotation of HANDLE (7) from HOT to COLD
is centered.
Use a screwdriver to tighten SCREWS (8) on LOCKNUT (6). Work your way around LOCKNUT (6), tightening
the screws slightly each time until all are snug to ensure even pressure.
Turn off water at
main supply.
7
A
Phillips Screwdriver
Adjustable Wrench
SPOUT BASE
Plumbers' Putty or Caulking
7
B
1
PUTTY
3
2
2
3
SINK OR
4
5
8
6
MOUNTING
SURFACE
4
5
8
6

MAKE WATER SUPPLY CONNECTIONS
2
Turn off hot and cold water supplies before beginning.
Connect FLEXIBLE SUPPLIES (1, 2) directly
to wall supplies. Connection on fitting
supplies are 3/8" compression. Connect
left supply (Marked with a Red Stripe) to Hot
and right supply (Marked with Blue Stripe) to
Cold wall supply. Use adjustable wrench to
tighten connections. Do not over tighten.
Faucet supplies are 21" long from faucet base.
Note: If additional supply length is
required, installer must purchase
additional parts separately.
Important: If SUPPLY HOSES (1, 2) are
too long, loop as illustrated to avoid kinking.
INSTALL WEIGHTS
3
With HAND SPRAY (1) seated in FAUCET (2),
install WEIGHTS (4) onto HOSE (3) using two
SCREWS (5). Locate the WEIGHTS (4) two feet (2')
from the underside of the sink deck.
Tighten SCREWS (5) firmly.
2
1
COLD
HOT
2
1
TEST INSTALLED FAUCET
4
Move HANDLE (1) down into
"off" position.
Turn on water supplies.
Check connections for leaks.
(See Section 5)
6
8
2
24"
3
With HANDLE (1) down in "off" position,
pull HAND SPRAY (2) from FAUCET (5)
and disconnect HAND SPRAY (2). Be
careful not to lose WASHER (7). Pull
HOSE (3) (HOSE should pull approximately
2 feet) and direct open HOSE END (4)
into sink.
1
7
3
5
Operate handle up and down, in COLD and HOT positions,
to flush water lines thoroughly.
Place WASHER (7) into HOSE END (4) and
connect HAND SPRAY (2) to HOSE END (4).
Place HAND SPRAY (2) back into faucet.
Check HAND SPRAY (2) operation:
With faucet on push BUTTON (6) for a broad cleansing
spray. BUTTON (6) will lock into this position.
To unlock BUTTON (6), rotate BUTTON (6) left or right
using the TAB (8). Faucet will return to standard spray.
4
5
4
M968473 REV 1.8

CHECK CONNECTIONS FOR LEAKS.
5
Move HANDLE down into "off" position.
Turn on water supplies and check connections for leaks
.
Operate HANDLE (2) up and down, left and right to flush
water lines thoroughly.
Operate HAND SPRAY and check connections for leaks.
SERVICE
6
If faucet drips, operate HANDLE several times from "off" to "on." Do not
apply excessive force.
Clogged CARTRIDGE outlets or inlets may cause reduced flow.
To clean, first turn off water supply then:
CHECK CONNECTIONS
FOR LEAKS
Remove INDEX BUTTON (1), loosen HANDLE SCREW (2) and remove HANDLE (3).
Unthread the ESCUTCHEON CAP (4). Unthread three MOUNTING SCREWS (5).
Lift CARTRIDGE (6) off MANIFOLD (7) and remove CARTRIDGE SEALS (8).
Clean MANIFOLD (7), CARTRIDGE (6) ports and SEALS (8).
Place SEALS (8) into CARTRIDGE PORTS (6A).
Place CARTRIDGE (6) onto MANIFOLD (7) and tighten MOUNTING
SCREWS (5) alternately.
Replace ESCUTCHEON CAP (4), HANDLE (3), tighten HANDLE
SCREW (1) and install INDEX BUTTON (2).
HOT LIMIT SAFETY STOP ADJUSTMENT
By restricting handle rotation and limiting the amount of hot water allowed
to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental
scalding. To set the maximum hot water temperature of your faucets, all you
need to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Remove HANDLE BUTTON (1) and loosen SET SCREW (2). Pull
HANDLE (3) off valve stem. Pull off CAP (4). Use a flat blade
screwdriver or your fingers to pull up and rotate red HOT LIMIT
SAFETY STOP (5). Follow Step "A" or "B" to adjust min./max.
discharge temperature. "0" being the hottest to "7" the coldest
temperature setting. Factory set at "0".
Replace ESCUTCHEON CAP (4), HANDLE (3), tighten
HANDLE SCREW (1) and install INDEX BUTTON (2).
SETTING NUMBERS
PRY RED RING FORWARD
AND ROTATE CLOCKWISE
ADJUSTMENT WHEN
WATER IS TOO COLD
"B"
"B"
TEMPERATURE
"B"
PRY RED RING FORWARD
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
"A"
0
1
2
3
4
5
6
2
1
"A"
"A"
ADJUSTMENT WHEN
WATER IS TOO HOT
6
5
6A
3
4
5
6
8
7
"RED RING"- HOT
LIMIT SAFETY STOP
CARE:
7
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
M968473 REV 1.8