INSTALLATION INSTRUCTIONS
Wall Hung Bathroom Sink
*NOTE: For installation of models using concealed or exposed arms, follow instruction
provided by arms manufacturer.
Introduction: Thank you for selecting our products...products which have been the benchmarks of fine quality for years. To help
insure that the installation process will proceed smoothly, please read these instructions carefully before you begin. Also, review
the recommended tools and materials list; carefully unpack and examine your new plumbing fixture.
!
CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!
NOTE:
Recommended Tools & Materials
Pictures may not exactly define contour of china and components.
Putty Kinfe
Pipe Wrench
Level
1
Channel Lock Pliers
Provide suitable reinforcement behind
Adjustable Wrench
finished wall for lavatory hanger mounting
screws. *Determine horizontal center line
location of support from the table listed in
Step 2. (Make sure support bottom
extends to lavatory back wall bottom.)
NOTE: If replacing an existing sink be
certain to shut off water supply before
removing old sink.
2
Part # Model
Determine the
desired rim height
(for example 32")
then select from the
Table at right the
height of the hanger
mounting bolts
centerline
EXAMPLE:
For Lucerne:
32"-1"=31"
For Ledgewood:
32"+2-7/8"=34-7/8"
0124
0321
0355/0356
0372/0373
4300
4867/4869
5300
RIM
HEIGHT
A
*
Drill
TABLE
Comrade
Declyn
Lucerne
Penlyn
Ledgewood
Regalyn
Ledgemere
WASTE
FINISHED FLOOR
Plumbers' Putty or
Caulking
C/L of 2X8
Support
*
Finished
Floor
ANCHORING SLOTS
Tubing Cutter
Phillips Screwdriver
Hanger
Location
Distance "A"
- 2-1/2" (64mm)
- 2-3/4" (70mm)
- 1" (25mm)
- 1/8" (3mm)
+ 2-7/8" (73mm)
+ 2-3/4" (70mm)
+ 2-1/2" (64mm)
C/L OF HANGER
HANGER
HOLES FOR
ANCHOR
SCREWS
IN BACK
DRAPERY
SUPPLIES AS
REQUIRED
Basin Wrench
Saber Saw
Regular Screwdriver
Tape
Measure
Hacksaw
3
Position hanger according to Step 2,
making sure its center is aligned with
the waste hole centerline. Mark the
hanger screw locations through its
mounting holes.
4
Drill pilot holes in positioning screw
slots of hanger. (Note: Some models
are supplied with anchor screws, or
steel hangers for lavatory installations.
Other models are not provided with
mounting hardware which can be
purchased at local hardware outlets.
Lavator-ies with bottom anchor screw
holes should be secured with anchor
screws in addition to hangers.
MOUNTING SCREW
HOLES (4)
POSITIONING
SCREW SLOTS (2)
© American Standard Inc. 2003
730427-100 Rev. B
5
Affix hanger to wall (hand tighten only). Mount lavatory for
positioning, level the deck, and mark bottom anchor screw
holes (if applicable). Remove lavatory, tighten the hanger
positioning screws and drill pilot holes for anchor screws
and 4 mounting screws. Install and tighten the mounting
screws.
Steel
Hanger
Return the fitted lavatory to the installed position.
7
Connect trap to drain assembly hand tight to check
alignment. It may be necessary to cut off part of the
tailpiece (area "B") or part of the horizontal leg of the
trap (area "C").
Mounting
Screw
Positioning
Screw
Lavatory
Following manufacturers instructions, install faucet and
6
Anchor Screw
(if used)
drain assembly. (Not included). Be certain to apply a
bead of sealing putty on the underside of the drain (Part
"A") in order to ensure a watertight seal between the
lavatory and drain. Remove excess putty after installing
drain on lavatory.
A
C
B
8
Secure lavatory on hanger as shown in 5. Insert and
tighten anchor screws if applicable. Connect hot and
cold supply lines to the shut-off valves. Tighten trap
joints for watertight assembly. Apply a bead of caulk
around the edge which contacts the wall as shown.
Caulk
Shut-off
Valves
Saniwares
AMERICAN STANDARD ONE-YEAR LIMITED WARRANTY
If inspection of this American Standard plumbing product, within one year after its initial installation, confirms that it is defective in
materials or workmanship, American Standard will repair or, at its option, exchange the product for a similar model.
This limited warranty does not apply to local building code compliance; since local building codes vary considerably, the purchaser
of this product should check with a local building or plumbing contractor to insure local code compliance before installation.
This warranty shall be void if the product has been moved from its initial place of installation; if it has been subjected to faulty
maintenance, abuse, misuse, accident or other damage; if it was not installed in accordance with American Standard's instructions; or if it
has been modified in a manner inconsistent with the product as shipped by American Standard.
American Standard's option to repair or exchange the product under this warranty does not cover any labor or other costs of removal
or installation, nor shall American Standard be responsible for any other incidental or consequential damages attributable to a
product defect or to the repair or exchange of a defective product, all of which are expressly excluded from this warranty. (Some
states or provinces do not allow the exclusion or limitation of implied warranties, so this exclusion may not apply to you.)
This warranty gives you specific legal rights. You may have other statutory rights that vary from state to state or from province to
province, in which case this warranty does not affect such statutory rights.
For service under this warranty, it is suggested that a claim be made through the contractor or dealer from or through whom the
product was purchased, or that a service request (including a description of the product model and of the defect) be sent to the following
address:
In the United States:
American Standard, Inc.
One Centennial Ave.
Piscataway, New Jersey 08855
Attention: Director of Consumer Affairs
Toll Free: (800) 442-1902
In Canada:
American Standard, Inc.
2480 Stanfield Rd.,
Mississauga, Ontario
Canada L4Y 1S2
Toll Free: (800) 387-0369
Customer Service Manager
Ecatepec 55540 Edo. Mexico
In Mexico:
American Standard, Inc.
Via Morelos #330
Col. Santa Clara
730427-100 Rev. B