American Standard Retrospect Round Front Toilet none User Manual

INSTALLATION INSTRUCTIONS
*NOTE: For installation of models using concealed or exposed arms, follow instruction
provided by arms manufacturer.
Introduction: Thank you for selecting our products...products which have been the benchmarks of fine quality for years. To help insure that the installation process will proceed smoothly, please read these instructions carefully before you begin. Also, review the recommended tools and materials list; carefully unpack and examine your new plumbing fixture.
!
CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!
NOTE:
Recommended Tools & Materials
Pictures may not exactly define contour of china and components.
Putty Kinfe
Pipe Wrench
Level
1
Channel Lock Pliers
Provide suitable reinforcement behind
Adjustable Wrench
finished wall for lavatory hanger mounting screws. *Determine horizontal center line location of support from the table listed in Step 2. (Make sure support bottom extends to lavatory back wall bottom.)
NOTE: If replacing an existing sink be certain to shut off water supply before removing old sink.
2
Part # Model
Determine the desired rim height (for example 32") then select from the Table at right the height of the hanger mounting bolts centerline
EXAMPLE: For Lucerne:
32"-1"=31"
For Ledgewood:
32"+2-7/8"=34-7/8"
0124 0321 0355/0356 0372/0373 4300 4867/4869 5300
RIM
HEIGHT
A
*
Drill
TABLE
Comrade Declyn Lucerne Penlyn Ledgewood Regalyn Ledgemere
WASTE
FINISHED FLOOR
Plumbers' Putty or Caulking
C/L of 2X8 Support
*
Finished Floor
ANCHORING SLOTS
Tubing Cutter
Phillips Screwdriver
Hanger Location
Distance "A"
- 2-1/2" (64mm)
- 2-3/4" (70mm)
- 1" (25mm)
- 1/8" (3mm) + 2-7/8" (73mm) + 2-3/4" (70mm) + 2-1/2" (64mm)
C/L OF HANGER
HANGER
HOLES FOR ANCHOR SCREWS IN BACK DRAPERY
SUPPLIES AS REQUIRED
Basin Wrench
Saber Saw
Regular Screwdriver
Tape Measure
Hacksaw
3
Position hanger according to Step 2, making sure its center is aligned with the waste hole centerline. Mark the hanger screw locations through its mounting holes.
4
Drill pilot holes in positioning screw slots of hanger. (Note: Some models are supplied with anchor screws, or steel hangers for lavatory installations. Other models are not provided with mounting hardware which can be purchased at local hardware outlets. Lavator-ies with bottom anchor screw holes should be secured with anchor screws in addition to hangers.
MOUNTING SCREW
HOLES (4)
POSITIONING
SCREW SLOTS (2)
© American Standard Inc. 2003
730427-100 Rev. B
5
Affix hanger to wall (hand tighten only). Mount lavatory for positioning, level the deck, and mark bottom anchor screw holes (if applicable). Remove lavatory, tighten the hanger positioning screws and drill pilot holes for anchor screws and 4 mounting screws. Install and tighten the mounting screws.
Steel Hanger
Return the fitted lavatory to the installed position.
7
Connect trap to drain assembly hand tight to check alignment. It may be necessary to cut off part of the tailpiece (area "B") or part of the horizontal leg of the trap (area "C").
Mounting Screw
Positioning Screw
Lavatory
Following manufacturers instructions, install faucet and
6
Anchor Screw (if used)
drain assembly. (Not included). Be certain to apply a bead of sealing putty on the underside of the drain (Part "A") in order to ensure a watertight seal between the lavatory and drain. Remove excess putty after installing drain on lavatory.
A
C
B
8
Secure lavatory on hanger as shown in 5. Insert and tighten anchor screws if applicable. Connect hot and cold supply lines to the shut-off valves. Tighten trap joints for watertight assembly. Apply a bead of caulk around the edge which contacts the wall as shown.
Caulk
Shut-off Valves
Saniwares
AMERICAN STANDARD ONE-YEAR LIMITED WARRANTY
If inspection of this American Standard plumbing product, within one year after its initial installation, confirms that it is defective in
materials or workmanship, American Standard will repair or, at its option, exchange the product for a similar model.
This limited warranty does not apply to local building code compliance; since local building codes vary considerably, the purchaser
of this product should check with a local building or plumbing contractor to insure local code compliance before installation.
This warranty shall be void if the product has been moved from its initial place of installation; if it has been subjected to faulty maintenance, abuse, misuse, accident or other damage; if it was not installed in accordance with American Standard's instructions; or if it has been modified in a manner inconsistent with the product as shipped by American Standard.
American Standard's option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or installation, nor shall American Standard be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product, all of which are expressly excluded from this warranty. (Some states or provinces do not allow the exclusion or limitation of implied warranties, so this exclusion may not apply to you.)
This warranty gives you specific legal rights. You may have other statutory rights that vary from state to state or from province to province, in which case this warranty does not affect such statutory rights.
For service under this warranty, it is suggested that a claim be made through the contractor or dealer from or through whom the product was purchased, or that a service request (including a description of the product model and of the defect) be sent to the following address:
In the United States:
American Standard, Inc.
One Centennial Ave.
Piscataway, New Jersey 08855
Attention: Director of Consumer Affairs
Toll Free: (800) 442-1902
In Canada:
American Standard, Inc.
2480 Stanfield Rd.,
Mississauga, Ontario
Canada L4Y 1S2
Toll Free: (800) 387-0369
Customer Service Manager
Ecatepec 55540 Edo. Mexico
In Mexico:
American Standard, Inc.
Via Morelos #330
Col. Santa Clara
730427-100 Rev. B