SELECTRONIC
®
DC POWERED PROXIMITY EXPOSED
URINAL FLUSH VALVE
0.125, 0.25, 0.5 & 1.0 GPF
Exposed Flushometer
for 3/4" Top Spud Urinals
CLOG RESISTANT
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and
flush valves.
• Range can be adjusted manually or with optional remote control.
• Sensor Features Low Battery Indicator.
MODEL NUMBERS
6063.013 6064.013 6062.601
6063.025 6064.025 6063.505
6063.051 6064.051 6063.510
6063.101 6064.101 6063.513
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
Certied to comply with ASME A112.19.2
© 2015 AS America, Inc.
Installation Instructions
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com
or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093))
© 2015 AS America Inc.
1
M965647 REV. 1.4 (7/15)
Thank you for selecting American-Standard...the benchmark of ne quality for over 100 years. To ensure that your
installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
Some Residual Water May Remain In The Valve During Shipping.
All American Standard Products Are Water Tested At Our Factory.
Remove the Flush Valve items from the carton. The illustration below shows all items after they have been
removed from the carton. Some items may be packaged partially assembled to other items.
1. Installation Instructions
2. Flush Valve Body Assembly
3. Vacuum Breaker Tube
4. Spud Coupling Nut and Washers
6. Wall Escutcheon
7. Cover Tube
8. Sweat Adapter
9. Stop Valve
5. Spud Flange
CARE INSTRUCTIONS:
DO: CLEAN THE PRODUCT WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
DO NOT REMOVE PROTECTIVE FILM FROM SENSOR
EYE UNTIL INSTALLATION IS COMPLETE.
7
6
8
9
2
SELECTRONIC
DC POWERED PROXIMITY EXPOSED
URINAL FLUSH VALVE
0.125, 0.25, 0.5 & 1.0 GPF
®
MODEL NUMBERS
6063.013 6064.013 6062.601
6063.025 6064.025 6063.505
6063.051 6064.051 6063.510
6063.101 6064.101 6063.513
3
Exposed Flushometer
for 3/4" Top Spud Urinals
CLOG RESISTANT
1
© 2015 AS America, Inc.
Installa tion Instructions
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and
• Range can be adjusted manually or with optional remote control.
•
Sensor Features Low Battery Indicator.
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
4
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com
or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
5
(In Toronto Area only: 1-905-306-1093))
2
M965647 REV. 1.4 (7/15)
Roughing-in Dimensions Fig. 1
Right or Left Hand Installation
See (Section 5) for converting Flush
Valve to Left Hand Installation.
73 mm
MANUAL
OVERRIDE
BUTTON
292 mm
(11-1/2")
120 mm
(4-3/4")
*-C-L-
152mm MIN.
(6") MIN.
(2-7/8")
L-C-
305 mm MÁX.
(12" MÁX.)
108mm-134mm
(4-1/4" TO 5-1/4")
FOR 3/4" TOP
SPUD FIXTURES
(1" NPT)
412 mm
(16-1/2")
FINISHED WALL
76mm MAX.
(3) MAX.
GENERAL DESCRIPTION:
SELECTRONIC™ PROXIMITY URINAL FLUSH VALVE
Exposed Flushometer for 3/4" Top Spud Fixtures
Exclusive, self cleaning piston-type ush valve with
proximity operation and manual override. Operates
on DC (battery) power. Recommended operating
pressure 35 to 80 psi. Can install left or right-handed.
Detection Zone can also be adjusted manually, or
with optional remote control.
15˚
DETECTION ZONE
400mm-800mm
(15-3/4 TO 31-1/2)
*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6
fixture. Consult Codes for details.
" (152mm) above
RECOMMENDED TOOLS; Fig. 2.
1. Teon Tape
2. Flat Blade Screwdriver
3. Adjustable Wrench
4. Tape Measure
5. Hacksaw
6. Tubing Cutter
7. File
8. For Sweat Connection; Solder and Torch
9. 2.5mm Hex Wrench
10. 1.5mm Hex Wrench
PRIOR TO INSTALLATION
Note: Prior to installing the Selectronic™Flush
Valve the following items must be installed.
1. Urinal
2. Drain line
3. Water supply line
IMPORTANT:
• All plumbing and electrical wiring should be
installed in accordance with applicable codes
and regulations.
• The use of water hammer arrestors is strongly
recommended for commercial applications. All piping
behind the walls should be properly secured and
fastened.
• Wate r supply lines must be sized to provide an
adequate volume of water for each xture.
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
Fig. 2
1
2
10'
4
3
6
5
8
7 9 10
• Flush all water lines prior to operation (See Step 4).
Dirt and debris can cause ush valve to run continuously.
• With the exception of Stop Valve Inlet, DO NOT
use pipe sealant or plumbing grease on any
valve component or coupling!
• Protect the chrome or special nish on the Flushometer.
DO NOT USE toothed tools on nished surfaces to install
or service these valves. Also see “Care and Cleaning”
section of this manual.
• This product contains mechanical and/or electrical
components that are subject to normal wear. These
components should be checked on a regular basis and
replaced as needed to maintain the valve’s performance.
3