Comfortable bathing design with form-tted backrest and molded-in armrests
❏ 2425VC-LHO Built-In Integral Apron
Left Hand Drain Outlet (specify color)
❏ 2425VC-RHO Built-In Integral Apron
Right Hand Drain Outlet (specify color)
• EverClean® System
• Acrylic with berglass reinforcement
• Integral apron with removable access panel
• Integral three-sided, tiling/water retention ange
• 1.25 HP self-draining pump/motor
• Eight ow adjustable jets including:
- Two adjustable Comfort Jets™ Hi Flo
- Six adjustable Comfort Jets™
• Two silent air volume controls
• Side-mounted On/Off control
• Deep Soak Overow Drain for maximum water depth
• Complete factory installed and tested whirlpool system
WHIRLPOOL AND BATHING POOL
HIGH GLOSS
❏ 2425V-LHO Built-In Integral Apron
Left Hand Drain Outlet (specify color)
❏ 2425V-RHO Built-In Integral Apron
Right Hand Drain Outlet (specify color)
• Same as above without the EverClean® System
❏ 2425V-LHO.002 Bathing Pool
❏ 2425V-RHO.002 Bathing Pool
Nominal Dimensions:
60" x 32" x 21-1/2" (1524 x 813 x 546mm)
Compliance Certications ­Meets or Exceeds the Following Specications:
• Underwriters Laboratories - Hydromassage
Bathtubs UL 1795
• ASME A112.19.7M for Whirlpool Appliances
• ANSI Z124.1 for Plastic Bathtubs
• ASTM E162 for Flammability
• NFPA 258 for Smoke Density
American Standard whirlpools with EverClean® incorporate a patented silver-ion additive right into the circulation piping to protect the pipes from mold, mildew, algae and fungus that could cause deterioration or staining of the pipes.
Components Required:
Bath Filler*: (specify nish) Bath Drain: 1599.205.XXX (specify color)
Custom Accessories Available:
* See American Standard Faucet Selector
For color/nish availability and other faucet choices, please see the Product Selector and Pricing Guide.
NOTE: Whirlpool Heater is designed to maintain water temperature during operation. It will not heat cold water to desired bathing temperature.
SEE REVERSE FOR ROUGHING-IN DIMENSIONS AND PRODUCT SPECIFICATIONS
© 2008 AS America Inc.
H89
Revised 3/06
GENERAL SPECIFICATIONS FOR 2425V WHIRLPOOL
WHIRLPOOL ELECTRICAL SPECIFICATIONS
PUMP 1.25 HP, 9.7 AMPS,120V.
60 x 32 x 20-1/2 (1524 x 813 x 521mm)
92 Lbs. (42 Kg.)
675 Lbs. (306 Kg.)
70 Gal. (265 L.)
39 Gal. (148 L.)
42 x 22 In. (1067 x 559mm)
53 x 25-1/2 In. (1346 x 648mm)
17-1/2 (445mm)
51 Lbs./Sq.Ft. (247 Kgs./Sq.m)
INSTAL LED SI ZE WEIGHT WEIGHT w/WAT ER GAL. T O OVER FLOW WHIRLP OOL MI N. OPE RATING VOL. BATHIN G WELL AT SU MP BATHIN G WELL AT RI M WATER DEPTH TO OVE RFLOW FLOOR LOADIN G (PROJE CTED A REA)
32"
(813mm)
21-1/2"
(546mm)
20-1/2"(H)
(521mm)
19-1/8"(A)
(486mm)
DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124.1 AND A112.19.7.
C/L OF OVERFLOW
CUT OUT IN FLOOR
FOR DRAIN
60"
(1524mm)
32"
(813mm)
7-1/2"
(191mm)
10-1/2"
(267mm)
3"
(76mm)
2-7/8" (73mm)
6"
(152mm)
13-1/2"
(343mm)
16"
(406mm)
Model 2425V-LHO
GENERAL SPECIFICATIONS FOR 2425V BATHING POOL
60 x 32 x 20-1/2 (1524 x 813 x 521mm)
77 Lbs. (35 Kg.)
661 Lbs. (299 Kg.)
70 Gal. (265 L.)
42 x 22 In. (1067 x 559mm)
53 x 25-1/2 In. (1346 x 648mm)
17-1/2 (445mm)
50 Lbs./Sq.Ft. (242 Kgs./Sq.m)
INSTAL LED SI ZE WEIGHT WEIGHT w/WAT ER GAL. T O OVER FLOW BATHIN G WELL AT SU MP BATHIN G WELL AT RI M WATER DEPTH TO OVE RFLOW FLOOR LOADIN G
(PROJE CTED A REA)
shown
EVOLUTION™ 5' X 32" IA-LHO / RHO
WHIRLPOOL AND BATHING POOL
HIGH GLOSS
NOTES:
BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND, OR PENINSULA TYPE INSTALLATION. SUPPORT OF BATH BY SUMP BEDDING. SUPPORT AND ENCLOSING MATERIAL BY OTHERS.
■REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.
FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
© 2008 AS America Inc.
PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1 These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided leaet.