INSTALLATION AND OPERATION MANUAL FOR EVERCLEAN/EVOLUTIONAIR BATHS

MODEL 2422L.068C

5' x 32"

2422V.068C

 

MODEL 2771L.068C

5' x 36"

2771V.068C

 

MODEL 2645L.068C

OVAL

2645V.068C

 

MODEL 7236L.068C

6' x 36"

7236V.068C

 

MODEL 2425L.168C

5' x 32" IA-RHO

2425V.168C

 

MODEL 2425L.268C

5' x 32" IA-LHO

2425V.268C

 

THANK YOU...

for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The air bath is completely assembled with air blower and system piping. All you need to finish the installation are your selected fittings and electrical connections.

To ensure maximum performance and pleasure from this product, please follow the instructions and cautions.

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

© AS Americas Inc. 2010

All product names listed herein are trademarks of AS Americas Inc. unless otherwise noted.

1

754072-100 Rev. A

TABLE OF CONTENTS:

Safety Instructions............................................................................

Page 3

General Information..........................................................................

Page 4

Optional Components.......................................................................

Page 4

Specifications....................................................................................

Page 5

Roughing-in Reference.....................................................................

Page 6

Framing and Support Instructions.....................................................

Page 7

Mounting Instructions........................................................................

Page 8

Electrical Connections.......................................................................

Page 9

Remote Blower Location Option........................................................

Page 10

Post Installation Clean-up..................................................................

Page 11

Operation: Air Bath.............................................................. ..............

Page 12

Cleaning and Maintenence................................................................

Page 13

Warranty............................................................................................

Page 14

754072-100 Rev. A

2

IMPORTANT SAFETY INSTRUCTIONS

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK

OR INJURY TO PERSONS

READ AND FOLLOW ALL INSTRUCTIONS!

!WARNING: Risk of personal injury. Do not permit children to use this unit without adult supervision.

!WARNING: Risk of personal injury. Do not operate this unit without the guard over the suction fitting.

!WARNING: Risk of electric shock. Do not permit electrical appliances (hair dryer, telephone, radio, etc.) within

60 inches (1524mm) of this unit.

!WARNING: Risk of hyperthermia and possible drowning. People using medications and/or having adverse

medical history should consult a physician before using this product.

!WARNING: Risk of personal injury. Do not overfill unit before entering. Entering tub when filled more than 2/3

can cause overflow and slippery conditions. Exercise caution when entering and exiting.

!WARNING: No Food or Alcoholic Beverages. Use of your bathtub immediately after meals is not

recommended. Avoid alcohol consumption before or during bathing. Alcoholic beverages can cause drowsiness or hyperthermia resulting in loss of consciousness or even drowning.

!WARNING: Pregnancy. If you are or think you may be pregnant, consult your physician before using the bathtub.

Never drop or insert any object into any opening.

Use this unit only for its intended use as described in this manual. Do not use any attachments not recommended by American Standard.

The unit must be connected only to a supply circuit that is properly protected by a ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the bathtub without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this air bath. Disconnect the air bath and have the problem corrected by a licensed electrician before using.

SAVE THESE INSTRUCTIONS

3

754072-100 Rev. A

General Installation Information

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately. After inspection and during installation, protect the bath from construction damage. Before installation, and before enclosing with wallboard, tile, etc., the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling! Do not make unauthorized modifications to the air bath system. This could adversely affect the safety and performance of the air bath and void the warranty. Do not handle or move the air bath by the air blower or piping system. Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others.

For electrical requirements, refer to section titled “Air Bath Electrical Installation Instructions”.

Check for availability of optional American Standard wall tiling bead (required for recess installation).

Protect all finished surfaces of the air bath during construction and installation using a drop cloth.

! WARNING: Do not lift air bath by the piping harness at any time.

List of Required Tools and Supplies:

Tools

Supplies

Level

Nails

Tape Measure

Putty

Pipe Wrench

Caulking (waterproof)

Slip Joint Pliers

1 x 4 Stringers

Screw Driver

Drop Cloth

Standard Woodworking Tools

Cement, Plaster, Grout

Personal Safety Equipment

Caulking Gun

LIST OF OPTIONAL COMPONENTS (NOT INCLUDED):

 

 

 

Optional Components

Required Components

 

 

 

(Not Included)

(Not Included)

Description

Model Number

 

 

 

Apron

Tile Bead

Drain

 

 

 

Kit

Kit

(Specify Finish)

 

 

 

 

 

 

Everclean/ Evolution5'x 32"

2422L

/ V.068C

9261.019

751755-100

1599.205.XXX*

 

 

 

 

 

 

Everclean/ Evolution5'x 36"

2771L

/ V.068C

9261.019

751755-100

1599.205.XXX*

Everclean/ Evolution6'x 36"

7236L

/ V.068C

9271.019

751755-100

1599.205.XXX*

Everclean/ Evolution5'x 32"IA

2425L

/ V.168C-RHO

INTEGRAL

NOT

1599.205.XXX*

2425L / V.268C-LHO

APPLICABLE

Everclean/ EvolutionOval

2645L

/ V.068C

9266.018

751755-100

1583.470.XXX

 

 

 

 

 

 

* These models require American Standard Deep Soak Max Drain 1599.205

754072-100 Rev. A

4

SPECIFICATIONS:

L

W

 

J

 

H

 

C

A

 

 

 

 

 

SIDE VIEW

END VIEW

 

B

DRAIN / OVERFLOW

 

 

 

 

GENERAL SPECIFICATIONS FOR EVOLUTION AIR BATHS

Description

Dimensions

Drain /

Height to

Cut Out

Rough-In

Tub Edge to

Weight with

Product

Apron /

Gallon to

 

L-W-H

Overflow

Underside

Pier

Recess

Centerline

Water / Floor

Weight

Mounting

Overflow

 

 

 

of Deck: C

G x F

E x D

Overflow: J

Loading

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2422L / V.068C

L 60" (1524mm)

A 20-1/8"

C 20"

58-1/2"

60-3/16"

3-1/4"

690lb (313kg)/

74 lb.

Optional

74 gal.

5' x 32"

W 32" (813mm)

(511mm)

(508mm)

(1485mm)

(1528mm)

(83mm)

(260kg/sq.m)

(34 kg.)

 

(280 l.)

 

H 21-1/2" (546mm)

B 11"

 

x

x

 

53lb/sq.ft.

 

 

 

 

 

(279mm)

 

30-1/2"

30-1/2"

 

 

 

 

 

 

 

 

 

(774mm)

(774mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2771L / V.068C

L 60" (1524mm)

A 20-1/8"

C 20"

58-1/2"

60-3/16"

3-1/4"

800lb (363kg)/

75 lb.

Optional

87 gal.

5' x 36"

W 36" (914mm )

(511mm)

(508mm)

(1485mm)

(1528mm)

(83mm)

(260kg/sq.m)

(34 kg.)

 

(329 l.)

 

H 21-1/2" (546mm)

B 11"

 

x

x

 

53lb/sq.ft.

 

 

 

 

 

(279mm)

 

34-1/2"

34-1/2"

 

 

 

 

 

 

 

 

 

(876mm)

(876mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7236L / V.068C

L 72" (1829mm)

A 20-1/8"

C 20"

70-1/2"

72-3/16"

3-1/4"

1031lb (467kg)/

106 lb.

Optional

111 gal.

6' x 36"

W 36" (914mm)

(511mm)

(508mm)

(1790mm)

(1833mm)

(83mm)

(280kg/sq.m)

(48 kg.)

 

(420 l.)

 

H 21-1/2" (546mm)

B 11"

 

x

x

 

57lb/sq.ft.

 

 

 

 

 

(279mm)

 

34-1/2"

34-1/2"

 

 

 

 

 

 

 

 

 

(876mm)

(876mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2425L / V.168C

L 60" (1524mm)

A 19-1/8"

C 20-1/4"

N/D

60-3/16"

2-7/8"

675lb (306kg)/

92 lb.

Included

70 gal.

IA-RHO

W 32" (813mm)

(485mm)

(515mm)

 

(1528mm)

(73mm)

(262kg/sq.m)

(42 kg.)

 

(265 l.)

2425L / V.268C

H 20-1/2" (521mm)

B 10-1/2"

 

 

x

 

54lb/sq.ft.

 

 

 

IA-LHO

 

(266mm)

 

 

30-1/2"

 

 

 

 

 

5' x 32"

 

 

 

 

(774mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2645L / V.068C

L 66" (1676mm)

A 15-1/4"

C 18-1/4"

64"

66-3/16"

1-3/4"

580lb (263kg)/

96 lb.

Optional

58 gal.

Oval

W 36" (914mm )

(387mm)

(464mm)

(1625mm)

(1681mm)

(44mm)

(175kg/sq.m)

(44 kg.)

 

(219 l.)

 

H 19-3/4" (502mm)

B 8-1/4"

 

x

x

 

36lb/pies

 

 

 

 

 

(209mm)

 

34"

34-1/2"

 

cuadrados

 

 

 

 

 

 

 

(863mm)

(876mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 1