American Standard 2422L.068C, 2422V.068C, 2771L.068C, 2771V.068C, 2645L.068C Installation Manual

...
INSTALLATION AND OPERATION MANUAL
FOR EVERCLEAN
MODEL 2422L.068C 5' x 32" 2422V.068C
MODEL 2771L.068C 5' x 36" 2771V.068C
MODEL 2645L.068C OVAL 2645V.068C
MODEL 7236L.068C 6' x 36"
/EVOLUTION™ AIR BATHS
MODEL 2425L.168C 5' x 32" IA-RHO 2425V.168C
MODEL 2425L.268C 5' x 32" IA-LHO 2425V.268C
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The air bath is completely assembled with air blower and system piping. All you need to finish the installation are your selected fittings and electrical connections.
To ensure maximum performance and pleasure from this product, please follow the instructions and cautions.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
© AS Americas Inc. 2010 All product names listed herein are trademarks of AS Americas Inc. unless otherwise noted.
1
754072-100 Rev. A
TABLE OF CONTENTS:
Safety Instructions............................................................................Page 3
General Information..........................................................................Page 4
Optional Components.......................................................................Page 4
Specifications....................................................................................Page 5
Roughing-in Reference.....................................................................Page 6
Framing and Support Instructions.....................................................Page 7
Mounting Instructions........................................................................Page 8
Electrical Connections.......................................................................Page 9
Remote Blower Location Option........................................................Page 10
Post Installation Clean-up..................................................................Page 11
Operation: Air Bath.............................................................. ..............Page 12
Cleaning and Maintenence................................................................Page 13
Warranty............................................................................................Page 14
754072-100 Rev. A
2
IMPORTANT SAFETY
INSTRUCTIONS
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, ELECTRIC SHOCK
OR INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS!
!
WARNING:
!
WARNING: Risk of personal injury. Do not operate this unit without the guard over the suction fitting.
WARNING: Risk of electric shock. Do not permit electrical appliances (hair dryer, telephone, radio, etc.) within
!
60 inches (1524mm) of this unit.
WARNING: Risk of hyperthermia and possible drowning. People using medications and/or having adverse
!
medical history should consult a physician before using this product.
WARNING: Risk of personal injury. Do not overfill unit before entering. Entering tub when filled more than 2/3
!
can cause overflow and slippery conditions. Exercise caution when entering and exiting.
!
WARNING: No Food or Alcoholic Beverages. Use of your bathtub immediately after meals is not
recommended. Avoid alcohol consumption before or during bathing. Alcoholic beverages can cause drowsiness or hyperthermia resulting in loss of consciousness or even drowning.
!
WARNING:
Never drop or insert any object into any opening.
Use this unit only for its intended use as described in this manual. Do not use any attachments not recommended by American Standard.
The unit must be connected only to a supply circuit that is properly protected by a ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the bathtub without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this air bath. Disconnect the air bath and have the problem corrected by a licensed electrician before using.
Risk of personal injury.
Pregnancy.
If you are or think you may be pregnant, consult your physician before using the bathtub.
Do not permit children to use this unit without adult supervision.
SAVE THESE INSTRUCTIONS
3
754072-100 Rev. A
General Installation Information
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately. After inspection and during installation, protect the bath from construction
damage. Before installation, and before enclosing with wallboard, tile, etc., the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling! Do not make unauthorized modifications to the air bath system. This could adversely affect
the safety and performance of the air bath and void the warranty. Do not handle or move the air bath by the air blower or piping system. Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others.
For electrical requirements, refer to section titled “Air Bath Electrical Installation Instructions”.
Check for availability of optional American Standard wall tiling bead (required for recess installation).
Protect all finished surfaces of the air bath during construction and installation using a drop cloth.
!
WARNING: Do not lift air bath by the piping harness at any time.
List of Required Tools and Supplies:
Tools
• Level
Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard Woodworking Tools
• Personal Safety Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 4 Stringers
• Drop Cloth
• Cement, Plaster, Grout
LIST OF OPTIONAL COMPONENTS (NOT INCLUDED):
Description
Everclean™ / Evolution™ 5' x 32"
Everclean
Everclean
Everclean™ / Evolution™ 5' x 32" IA
Everclean
* These models require American Standard Deep Soak Max Drain 1599.205
754072-100 Rev. A
/ Evolution™ 5' x 36"
/ Evolution™ 6' x 36"
/ Evolution™ Oval
Model Number
2422L / V.068C
2771L / V.068C
7236L / V.068C
2425L / V.168C - RHO 2425L / V.268C - LHO
2645L / V.068C
4
Optional Components
(Not Included)
Apron
Kit
9261.019
9261.019
9271.019
INTEGRAL
9266.018
Tile Bead
Kit
751755-100
751755-100
751755-100
NOT
APPLICABLE
751755-100
Required Components
(Not Included)
Drain
(Specify Finish)
1599.205.XXX*
1599.205.XXX*
1599.205.XXX*
1599.205.XXX*
1583.470.XXX
SPECIFICATIONS:
L
W
J
H
SIDE VIEW
END VIEW
GENERAL SPECIFICATIONS FOR EVOLUTION AIR BATHS
Description Drain /
2422L / V.068C
5' x 32"
2771L / V.068C
5' x 36"
Dimensions
L-W-H
L 60" (1524mm) W 32" (813mm) H 21-1/2" (546mm)
L 60" (1524mm) W 36" (914mm ) H 21-1/2" (546mm)
Overflow
A 20-1/8" (511mm) B 11" (279mm)
A 20-1/8" (511mm) B 11" (279mm)
Height to Underside of Deck: C
C 20" (508mm)
C 20" (508mm)
Cut Out
Pier
G x F
58-1/2"
(1485mm)
x
30-1/2"
(774mm)
58-1/2"
(1485mm)
x
34-1/2"
(876mm)
Rough-In
Recess
E x D
60-3/16"
(1528mm)
x
30-1/2"
(774mm)
60-3/16"
(1528mm)
x
34-1/2"
(876mm)
Tub Edge to
Centerline
Overflow: J
C
3-1/4"
(83mm)
3-1/4"
(83mm)
A
Weight with
Water / Floor
Loading
690lb (313kg)/ (260kg/sq.m) 53lb/sq.ft.
800lb (363kg)/ (260kg/sq.m) 53lb/sq.ft.
DRAIN / OVERFLOW
B
Product
Weight
74 lb.
(34 kg.)
75 lb.
(34 kg.)
Apron /
Mounting
Optional
Optional
Gallon to Overflow
74 gal.
(280 l.)
87 gal. (329 l.)
7236L / V.068C
6' x 36"
2425L / V.168C
IA-RHO
2425L / V.268C
IA-LHO
"
5' x 32
2645L / V.068C
Oval
L 72" (1829mm) W 36" (914mm) H 21-1/2" (546mm)
L 60" (1524mm) W 32" (813mm) H 20-1/2" (521mm)
L 66" (1676mm) W 36" (914mm ) H 19-3/4" (502mm)
A 20-1/8" (511mm) B 11" (279mm)
A 19-1/8" (485mm) B 10-1/2" (266mm)
A 15-1/4" (387mm) B 8-1/4" (209mm)
C 20" (508mm)
C 20-1/4" (515mm)
C 18-1/4" (464mm)
70-1/2"
(1790mm)
x
34-1/2"
(876mm)
N/D
64"
(1625mm)
x
34"
(863mm)
(1833mm)
(1528mm)
(1681mm)
5
72-3/16"
x
34-1/2"
(876mm)
60-3/16"
x
30-1/2"
(774mm)
66-3/16"
x
34-1/2"
(876mm)
3-1/4"
(83mm)
2-7/8"
(73mm)
1-3/4"
(44mm)
1031lb (467kg)/ (280kg/sq.m) 57lb/sq.ft.
675lb (306kg)/ (262kg/sq.m) 54lb/sq.ft.
580lb (263kg)/ (175kg/sq.m) 36lb/pies cuadrados
106 lb.
(48 kg.)
92 lb.
(42 kg.)
96 lb.
(44 kg.)
Optional
Included
Optional
TABLE 1
754072-100 Rev. A
111 gal. (420 l.)
70 gal. (265 l.)
58 gal. (219 l.)
Loading...
+ 9 hidden pages