American Dynamics ADACSNETD, ADACSNETDP Specsheet

DATA SHEET
SensorNet/Manchester Distribution Panel
Features That Make a Difference:
Amplifies SensorNet or Manchester protocol signals for multi-point
dome control Switch easily between SensorNet or Manchester protocols Accommodates home-run dome wiring via 16 output ports Supports home-run, daisy chain, and junction box (J-Box) wiring
topologies to accommodate any size system Install at head end or remote locations Rack (2U) mountable Thin, single PCB design allows the panel to be mounted either at the
front or rear of an electronics rack, facing in or out Surge suppression available on all data and power connections ADACSNETDP model includes power supply for multiple panels Compatible with American Dynamics® MegaPower matrix switcher/
controller systems and Intellex
®
Digital Video Management Systems
The SensorNet/Manchester distribution panel amplifies either a SensorNet or Manchester protocol signal for multi-point dome control which provides the flexibility to operate efficiently in either protocol setting. With 16 output driver links (two connectors per link), the panel can accommodate home-run dome wiring, multiple daisy-chained links to domes, or J-Boxes.
The panel also includes inputs for two hosts allowing you to maintain a connection between both the primary and backup CPUs and the devices connected to the panel, thereby providing a redundant solution1. For the ultimate control, you can monitor signal activities on each channel.
Installing the panel is easy, either at the head end or at remote locations and it can be used in place of a SensorNet J-Box when power is available for domes locally. The sleek, 2U design can easily be mounted at the front or rear of an electronics rack, facing in or out.
The panel is compatible with all versions of American Dynamics SpeedDome programmable dome cameras, Manchester receiver drivers, J-Boxes, and control systems that use SensorNet or Manchester protocols.
(1) The host input ports will be used in sequence whenever the previous input port is not receiving data.
SPECIFICATIONS
Model Numbers
ADACSNETD .............. SensorNet/Manchester Distribution Panel
ADACSNETDP ............. SensorNet/Manchester Distribution Panel
(without external power module)
(with external power module)
Physical
Dimensions (L x W x D) .......481 x 87 x 34 mm (18.9 x 3.4 x 1.3 in)
Body Length ...............445 mm (17.6 in)
Weight ...................0.75 kg (1.66 lbs)
Mounting ................. Standard electrical rack (2U), EIA-310-D (19 in)
IEC 60297-1 (482.6 mm) Wall mount
Electrical
Power Source .............. External power module
Input ..................... 12 to 30 V DC or AC
Power Consumption .........8 VA
Diagnostic Indicators
Power On/Heartbeat .......Green LED
Noise Detect ..............Red LED
Host A and B Receive Data . .Yellow LED Channels 1-16 Receive Data .Yellow LED
Protection ................. Internal primary current fuse
Cable to Transformer ........ 5 m (16.5 ft)
Input Connector ............ Euro-style 3-pin removable plug
Surge Protection Transient Voltage Suppressors
(TVS) ...................60 V, 250 A, 1.5 J
Certified limited power source required Multiple panels may be connected up to the maximum VA rating of the transformer
Isolation not required NEC Class 2
Inrush limiting DC isolation
18 AWG (0.823 mm
2
), 3-conductor
5.06 mm (0.2 in) terminal block
Gas discharge tube
impulse rated .............10 kA
Design Tolerance
Input Voltage Minimum ......11 V DC or AC without drop out
Input Voltage Maximum. .....>36 V DC or AC
Input Frequency ...........47 to 63 Hz
Allowable Dropout .........150 ms
Surge Protection
SensorNet/Manchester Ports
Transient Voltage Suppressors (TVS)
Breakdown Voltage ........7.6 to 9.3 V DC
Peak Current .............40 A
Capacitance ..............2000 pf at 1 kHz
Gas Discharge Tube Impulse Rate
DC Breakdown Voltage .....90 V DC
Insulation Resistance .......10,000 mΩ
Capacitance ..............2 pf max
8/20 µsec Impulse Discharge
Current ..................10 kA
Ten 8/20 µsec Impulses
Discharge Current .........5 kA
Isolation Transformer
Coupled .................. 2000 Vrms
PTC re-settled fuse protects transformer
Environmental
Operating Temperature .......-10° to 50°C (14° to 122°F)
Storage Temperature ........-40° to 70°C (-40° to 158°F)
Relative Humidity ...........0 to 95% noncondensing
Regulatory
EMC ...................... 47 CFR, Part 15
EN50130-4; EN55022 EN61000-3-2; EN61000-3-3
CISPR22
Safety .................... UL/IEC/EN/CSA C22.2.60950-1
Environmental .............. RoHS 2002/95/EC
WEEE 2002/96/EC IP code X0
DATA COMMUNICATION
SensorNet Manchester
Address Range Bit Rate
Maximum Cable Segment
3
Maximum Loads Cable Segment Repeaters Topologies
Transmission Medium
Connector
Connector PIN Assignments
1 km (3,300 ft) if repeaters are used
1.5 km (5,000 ft) if repeaters are not used 32 devices per cable segment 3 per run
SensorNet J-Boxes, distribution panels Distribution panels
Daisy chain, backbone, or star Daisy chain
Single non-polarized unshielded twisted pair UTP
Euro-style 3-pin removable plug 3.5 mm (0.14 in)
terminal block, Shield not used
PIN 1 - S+ (orange wire) PIN 2 - S - (yellow wire)
PIN 3 - Ground (Shield not used)
Terminating Resistor Physical Layer
RS-485, transformer-isolated, 2-wire RS-485, transformer-isolated, 2-wire
Link Layer Communications
ADMPCPU, ADTT16E Primary Touch Tracker, MegaPower 48
Controller Devices
Secondary Devices
(2) Input voltage greater than 36 VDC or AC may damage equipment (3) The maximum cable segment distance shown is the total distance per ADACSNETD driver. The panel contains 16 drivers labeled 1 through 16 and each driver has two physical
connectors on the front panel. If only one of the two connectors is used, the full distance can be applied to that connector. If both of the connectors are being used, the combined distance should not exceed the amount shown based upon wiring specified above.
Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies by region; contact your sales representative. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies.
© 2009 Tyco International Ltd. and its respective companies. All rights reserved. AD0117-DS-200903-R02-LT-EN
Plus, MegaPower LT, Intellex Digital Video Management System,
and ADACSNET SensorNet USB Module
SpeedDome Series and American Dynamics receivers/drivers,
distribution panels, J-Boxes, secondary Touch Tracker,
1 to 254 1 to 64
230.4 kbps 31 kbps
Single twisted pair 18 AWG (0.823 mm2) (Belden 8760),
22 AWG (0.326 mm2)
Euro-style 3-pin removable plug 3.5 mm (0.14 in) terminal block
PIN 1 - S+ (black wire) PIN 2 - S- (white wire)
120 Ω, switch selectable 120 Ω, switch selectable
Bi-directional, half duplex Simplex
ADMPCPU, AD2091, MegaPower 48 Plus,
SpeedDome Programmable Dome Cameras
and SensorNet I/O unit
www.americandynamics.net
1.5 km (5,000 ft)
polarized, Shielded
PIN 3 - Ground (Shield used)
and MegaPower 3200