American Dynamics ADAC422D, ADAC422DP Installation

Page 1
RS-422 / RS-485 Distribution Panel
Installation Guide
ADAC422D / ADAC422DP

About this Guide

This installation guide explains how to install the RS-422 / RS-485 Distribution Panel. The ADAC422DP includes an external power module.

About the Product

The RS-422 / RS-485 Distribution Panel:
Provides signal amplification for American Dynamics RS-422 / RS-485 dome-control communication.
Has 16 output ports to accommodate home-run dome wiring or multiple daisy-chained links to domes, J-boxes, or other distribution panels.
Each port has an LED that indicates received data, and a line status test switch with LED.
Is designed to be wall-mounted or installed in a 483mm (19in) EIA / IEC equipment rack.
Figure 2. Distribution Panel components
SW1 DIP Switches
Power Connecto 12–30V AC/DC
r
Host Connectors (RS-422)
Host Connector (RS-232)
Output Data Connectors
(RS-485), LEDS, and
Switches
If you need assistance...
Contact your Sales Representative.

Warning and Cautions

© 2008 Sensormatic Electronics Corp.
WARNING: RISK OF ELECTRIC
SHOCK! Disconnect AC power to the panel before servicing.
CAUTION-Electrostatic Sensitive Device: Follow proper handling
procedures to prevent component failure.

Installation

Parts
Install kit 0352-0332-01, used with the 0404-0410-01 distribution panel. It includes grounding hardware.
User Guide, Video Sys Comm Protocols & Cable Networks Con,p,Eur,3.5,22-16,1x5p 16 2109-0510-05
Con,p,Eur,3.5,22-16g,1x4p 2 2109-0510-04 Con,p,Eur,3.5,22-16g,1x3p 1 2109-0510-03 Con,p,Eur,.2c,28-12g,3p,orange 1 2109-0254-02 Cable,3c,18g,16x30,pvc,cm 16.50 6002-0024-01 Screw,m,php,st,z,6-32x1/4 1 2804-7106-06 Washer,int th,#6,st,z 1 2845-6300 Nut,hx,ss,6-32 1 2836-0001-03 Terminal,spade,#6,22-16aw 2 2141-0027-01
Required Tools
Phillips Screwdriver (rack and wall installations)
Hammer (wall installation)
Drill with bits (wall installation, if needed)
Pencil (wall installation)
Leveling device (wall installation).
1 8000-2573-19
RS-422 / RS-485 DISTRIBUTION PANEL 8200-0712-02, REV. E INSTALLATION GUIDE
1 of 4
Page 2
Rack Installation
1. Secure the distribution panel to the equipment rack.
2. For proper surge protection, attach the panel to a grounded rack or connect a conductor from the panel to ground using hardware provided. Ensure metal-to-metal contact.
Wall Installation
1. At the rear of the distribution panel, measure from key slot to key slot to determine screw/anchor locations. Then install suitable screws and anchors (not supplied) in the wall to which the panel is to attach. The wall and hardware must support 5.1kg (11.2 lbs).
2. Attach the panel to the pre-mounted screws. Then lock the panel in place by inserting a third screw into the wall centered adjacent to its top surface.
3. For proper surge protection, connect a conductor from the enclosure to ground using hardware provided. Ensure metal-to-metal contact.
SW1 Switch Settings
Pos. 0 Setting 1 Setting
1 LED Test On* LED Test Off
2 Not used Not used
3 Not used Not used
4 Not used Not used
5 Not used Not used
6 Not used Not used
7 Not used Not used
8 Not used Not used
* In LED test mode, all data detect and power-on/heartbeat
indicators should blink.
Line Status Test Switch
Each output port has a line status push button.

Specifications

Electrical
Power Source...............................External power module
Certified Limited Power Source required
Transformer: Multiple panels may be connected up to the maximum VA rating of the transformer.
Input ................ 12–30V, DC or AC, isolation not required
Frequency ..........................................................50–60Hz
Power Consumption.................................................. 8VA
Indicators:
Power-On/Heartbeat .................................. Green LED
Host A, B, C Data Detect............................Yellow LED
Channel 1–16 Data Detect .........................Yellow LED
Channel 1-16 Line Status
Test Switch..........................................Red/Green LED
Protection........................Certified Limited Power Source
NEC Class 2 Internal primary current fuse Inrush limiting DC isolation
Cable to transformer .......................................5m (16.5ft)
18 AWG, 3-conductor
Input Connector............. Euro-style 3-pin removable plug
5.06mm (0.2in) terminal block
Surge Protection ...................... Transguard rated at 60V,
250A, 1.5 Joules Gas discharge tube impulse rated at 10kA
Design Tolerance:
Input voltage minimum 11V DC or AC without drop out Input voltage >36V DC or AC may damage equipment
Input frequency............................................... 47–63Hz
Allowable drop out............................................. 150ms
Power connector pin assignments:
Pin Label Notes
1 and 3
2 Ground
12V – 30V
AC/DC
Connect 12–30V AC or DC power to these pins in any polarity
Used for surge protection and data line shields
LED Condition Meaning
Constant green, Blinking red
Constant green, red off “Data In” – shorted to ground
Constant red, Blinking green
Blinking red, Green off “Data In” + shorted to ground
Both LEDs off “Data In” + and – wires shorted
RS-422 / RS-485 DISTRIBUTION PANEL 8200-0712-02, REV. E INSTALLATION GUIDE
RS-422 line correctly wired
“Data In” + and – wires reversed
or open
2 of 4
Page 3
Surge Protection
EIA-232 and RS-422 / RS-485 Ports
Transient Voltage Suppressors (TVS):
Breakdown Voltage ..................................... 8.5V ±20%
Peak Current.......................................................... 40A
Capacitance ......................................... 1200pf @ 1kHz
Gas discharge tube impulse rated at:
DC Break Down Voltage .................................... 90Vdc
Insulation Resistance ................................... 10,000M
Capacitance .....................................................2pf Max
8/20µs Impulse Discharge Current....................... 10kA
Ten 8/20µs Impulses Discharge Current................ 5kA
Data Communication
Specification Parameter
Network Distance 1km (3300ft) per cable segment
Maximum Loads 10 per cable segment
Topologies Daisy Chain, Star
Transmission Medium Two twisted pairs 22AWG (0.326mm2), polarized, shielded
Connector Euro-style 3.5mm (0.14in) terminal block
Host A & B Signals (RS-422) (see note)
Host C Signals (RS-232) (see note)
Device Signals 1–16 (RS-485) Pin 1 ........................ RXHI+ (Yellow wire) (top-most pin)
Physical Layer RS-485, 4-wire, or RS-232
Data Encoding Start bit, Stop bit
Link Layer Framing Asynchronous
Link Layer Channel Full duplex
Application Protocol Proprietary
Collision Avoidance Polling by primary host controller device
Host Controller Devices MegaPower 48 Plus, RCSN422, and previous AD
Devices Domes, junction boxes, distribution panels
Repeaters Junction boxes, distribution panels
Note: The host input ports will be used in sequence (A to B to C) whenever previous input ports are not receiving data.
Pin 1 ........................RXHI+ (Orange wire) (top-most pin)
Pin 2 ...............................................RXLO- (Green wire)
Pin 3 ................................................TXHI+ (Yellow wire)
Pin 4 .................................................TXLO- (Brown wire)
Pin 1 ..................................................RXD (top-most pin)
Pin 2 ........................................................................ TXD
Pin 3 ....................................................................Ground
Pin 2 .................................................RXLO- (Brown wire)
Pin 3 ................................................TXHI+ (Orange wire)
Pin 4 ................................................. TXLO- (Green wire)
Pin 5 ....................................................... Ground (Shield)
SensorNet host controller products
Mechanical
Dimensions (LxWxD) ................................481x87x34mm
(18.9x3.4x1.3in)
Weight................................................... 0.75kg (1.66 lbs)
Mounting ..........EIA-310-D 19in. Electronic Racks (2 RU)
IEC 60297-1 482.6mm Electronic Racks (2 RU) Wall mount
Environmental
Operating Temperature........ –10° to 50°C (14° to 122°F)
Storage Temperature ......... –40° to 70°C (–40° to 158°F)
Relative Humidity .....................0 to 95% non-condensing
RS-422 / RS-485 DISTRIBUTION PANEL 8200-0712-02, REV. E INSTALLATION GUIDE
3 of 4
Page 4
Other Declarations

Declarations

Regulatory Compliance
EMC........................................................47 CFR, Part 15
EN 50130-4 EN 55022 EN61000-3-2 EN61000-3-3 CISPR 22
Safety ........................... UL/IEC/EN/CSA C22.2. 60950-1
Environmental..................................... RoHS 2002/95/EC
WEEE 2002/96/EC IP code X0
Regulatory Type
ADVDB
FCC COMPLIANCE: This equipment complies with Part 15 of the FCC rules for Class A digital devices when installed and used in accordance with the instruction manual. Following these rules provides reasonable protection against harmful interference from equipment operated in a commercial area. This equipment should not be installed in a residential area as it can radiate radio frequency energy that could interfere with radio communications, a situation the user would have to fix at their own expense.
EQUIPMENT MODIFICATION CAUTION: Equipment changes or modifications not expressly approved by Sensormatic Electronics Corporation, the party responsible for FCC compliance, could void the user's authority to operate the equipment and could create a hazardous condition.
About the Product” on page 1.
See “
Thank you for using American Dynamics products. We support our products through an extensive and worldwide network of dealers. The dealer, through whom you originally purchased this product, is your point of contact if you have a need for service or support. Our dealers are fully empowered to provide the very best in customer service and support. Dealers should contact American Dynamics at (800) 507-6268 or (561) 912-6259 or on the web at www.americandynamics.net.
WARRANTY DISCLAIMER: Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose.
NOTICE: The information in this manual was current when published. The manufacturer reserves the right to revise and improve its products. All specifications are therefore subject to change without notice.
LIMITED RIGHTS NOTICE: For units of the Department of Defense, all documentation and manuals were developed at private expense and no part of it was developed using Government Funds. The restrictions governing the use and disclosure of technical data marked with this legend are set forth in the definition of “limited rights” in paragraph (a) (15) of the clause of DFARS 252.227.7013. Unpublished - rights reserved under the Copyright Laws of the United States.
TRADEMARK NOTICE: American Dynamics and Sensormatic are trademarks or registered trademarks of
Sensormatic Electronics Corporation. Other product names mentioned herein may be trademarks or registered trademarks of Sensormatic or other companies.
COPYRIGHT: Under copyright laws, the contents of this manual may not be copied, photocopied, reproduced, translated or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of Sensormatic Electronics.
MDR 10/2008
RS-422 / RS-485 DISTRIBUTION PANEL 8200-0712-02, REV. E INSTALLATION GUIDE
4 of 4
Loading...