• Phillips Screwdriver (rack and wall installations)
• Hammer (wall installation)
• Drill with bits (wall installation, if needed)
• Pencil (wall installation)
• Leveling device (wall installation).
1 8000-2573-19
RS-422 / RS-485 DISTRIBUTION PANEL 8200-0712-02, REV. E
INSTALLATION GUIDE
1 of 4
Page 2
Rack Installation
1. Secure the distribution panel to the equipment
rack.
2. For proper surge protection, attach the panel to
a grounded rack or connect a conductor from
the panel to ground using hardware provided.
Ensure metal-to-metal contact.
Wall Installation
1. At the rear of the distribution panel, measure
from key slot to key slot to determine
screw/anchor locations. Then install suitable
screws and anchors (not supplied) in the wall to
which the panel is to attach. The wall and
hardware must support 5.1kg (11.2 lbs).
2. Attach the panel to the pre-mounted screws.
Then lock the panel in place by inserting a third
screw into the wall centered adjacent to its top
surface.
3. For proper surge protection, connect a
conductor from the enclosure to ground using
hardware provided. Ensure metal-to-metal
contact.
SW1 Switch Settings
Pos. 0 Setting 1 Setting
1 LED Test On* LED Test Off
2 Not used Not used
3 Not used Not used
4 Not used Not used
5 Not used Not used
6 Not used Not used
7 Not used Not used
8 Not used Not used
* In LED test mode, all data detect and power-on/heartbeat
indicators should blink.
Line Status Test Switch
Each output port has a line status push button.
Specifications
Electrical
Power Source...............................External power module
Certified Limited Power Source required
Transformer: Multiple panels may be connected up to
the maximum VA rating of the transformer.
Input ................ 12–30V, DC or AC, isolation not required
Frequency ..........................................................50–60Hz
Power Consumption.................................................. 8VA
Indicators:
Power-On/Heartbeat .................................. Green LED
Host A, B, C Data Detect............................Yellow LED
Channel 1–16 Data Detect .........................Yellow LED
Channel 1-16 Line Status
Test Switch..........................................Red/Green LED
Protection........................Certified Limited Power Source
NEC Class 2
Internal primary current fuse
Inrush limiting
DC isolation
Cable to transformer .......................................5m (16.5ft)
FCC COMPLIANCE: This equipment complies with
Part 15 of the FCC rules for Class A digital devices
when installed and used in accordance with the
instruction manual. Following these rules provides
reasonable protection against harmful interference from
equipment operated in a commercial area. This
equipment should not be installed in a residential area as
it can radiate radio frequency energy that could interfere
with radio communications, a situation the user would
have to fix at their own expense.
EQUIPMENT MODIFICATION CAUTION:
Equipment changes or modifications not expressly
approved by Sensormatic Electronics Corporation, the
party responsible for FCC compliance, could void the
user's authority to operate the equipment and could
create a hazardous condition.
About the Product” on page 1.
See “
Thank you for using American Dynamics products. We
support our products through an extensive and
worldwide network of dealers. The dealer, through
whom you originally purchased this product, is your
point of contact if you have a need for service or
support. Our dealers are fully empowered to provide the
very best in customer service and support. Dealers
should contact American Dynamics at (800) 507-6268
or (561) 912-6259 or on the web at
www.americandynamics.net.
WARRANTY DISCLAIMER: Sensormatic
Electronics Corporation makes no representation or
warranty with respect to the contents hereof and
specifically disclaims any implied warranties of
merchantability or fitness for any particular purpose.
NOTICE: The information in this manual was current
when published. The manufacturer reserves the right to
revise and improve its products. All specifications are
therefore subject to change without notice.
LIMITED RIGHTS NOTICE: For units of the
Department of Defense, all documentation and manuals
were developed at private expense and no part of it was
developed using Government Funds. The restrictions
governing the use and disclosure of technical data
marked with this legend are set forth in the definition of
“limited rights” in paragraph (a) (15) of the clause of
DFARS 252.227.7013. Unpublished - rights reserved
under the Copyright Laws of the United States.
TRADEMARK NOTICE: American Dynamics and
Sensormatic are trademarks or registered trademarks of
Sensormatic Electronics Corporation. Other product
names mentioned herein may be trademarks or
registered trademarks of Sensormatic or other
companies.
COPYRIGHT: Under copyright laws, the contents of
this manual may not be copied, photocopied,
reproduced, translated or reduced to any electronic
medium or machine-readable form, in whole or in part,
without prior written consent of Sensormatic
Electronics.
MDR 10/2008
RS-422 / RS-485 DISTRIBUTION PANEL 8200-0712-02, REV. E
INSTALLATION GUIDE
4 of 4
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.