American Dynamics ADAC422D, ADAC422DP Installation

RS-422 / RS-485 Distribution Panel
Installation Guide
ADAC422D / ADAC422DP

About this Guide

This installation guide explains how to install the RS-422 / RS-485 Distribution Panel. The ADAC422DP includes an external power module.

About the Product

The RS-422 / RS-485 Distribution Panel:
Provides signal amplification for American Dynamics RS-422 / RS-485 dome-control communication.
Has 16 output ports to accommodate home-run dome wiring or multiple daisy-chained links to domes, J-boxes, or other distribution panels.
Each port has an LED that indicates received data, and a line status test switch with LED.
Is designed to be wall-mounted or installed in a 483mm (19in) EIA / IEC equipment rack.
Figure 2. Distribution Panel components
SW1 DIP Switches
Power Connecto 12–30V AC/DC
r
Host Connectors (RS-422)
Host Connector (RS-232)
Output Data Connectors
(RS-485), LEDS, and
Switches
If you need assistance...
Contact your Sales Representative.

Warning and Cautions

© 2008 Sensormatic Electronics Corp.
WARNING: RISK OF ELECTRIC
SHOCK! Disconnect AC power to the panel before servicing.
CAUTION-Electrostatic Sensitive Device: Follow proper handling
procedures to prevent component failure.

Installation

Parts
Install kit 0352-0332-01, used with the 0404-0410-01 distribution panel. It includes grounding hardware.
User Guide, Video Sys Comm Protocols & Cable Networks Con,p,Eur,3.5,22-16,1x5p 16 2109-0510-05
Con,p,Eur,3.5,22-16g,1x4p 2 2109-0510-04 Con,p,Eur,3.5,22-16g,1x3p 1 2109-0510-03 Con,p,Eur,.2c,28-12g,3p,orange 1 2109-0254-02 Cable,3c,18g,16x30,pvc,cm 16.50 6002-0024-01 Screw,m,php,st,z,6-32x1/4 1 2804-7106-06 Washer,int th,#6,st,z 1 2845-6300 Nut,hx,ss,6-32 1 2836-0001-03 Terminal,spade,#6,22-16aw 2 2141-0027-01
Required Tools
Phillips Screwdriver (rack and wall installations)
Hammer (wall installation)
Drill with bits (wall installation, if needed)
Pencil (wall installation)
Leveling device (wall installation).
1 8000-2573-19
RS-422 / RS-485 DISTRIBUTION PANEL 8200-0712-02, REV. E INSTALLATION GUIDE
1 of 4
Rack Installation
1. Secure the distribution panel to the equipment rack.
2. For proper surge protection, attach the panel to a grounded rack or connect a conductor from the panel to ground using hardware provided. Ensure metal-to-metal contact.
Wall Installation
1. At the rear of the distribution panel, measure from key slot to key slot to determine screw/anchor locations. Then install suitable screws and anchors (not supplied) in the wall to which the panel is to attach. The wall and hardware must support 5.1kg (11.2 lbs).
2. Attach the panel to the pre-mounted screws. Then lock the panel in place by inserting a third screw into the wall centered adjacent to its top surface.
3. For proper surge protection, connect a conductor from the enclosure to ground using hardware provided. Ensure metal-to-metal contact.
SW1 Switch Settings
Pos. 0 Setting 1 Setting
1 LED Test On* LED Test Off
2 Not used Not used
3 Not used Not used
4 Not used Not used
5 Not used Not used
6 Not used Not used
7 Not used Not used
8 Not used Not used
* In LED test mode, all data detect and power-on/heartbeat
indicators should blink.
Line Status Test Switch
Each output port has a line status push button.

Specifications

Electrical
Power Source...............................External power module
Certified Limited Power Source required
Transformer: Multiple panels may be connected up to the maximum VA rating of the transformer.
Input ................ 12–30V, DC or AC, isolation not required
Frequency ..........................................................50–60Hz
Power Consumption.................................................. 8VA
Indicators:
Power-On/Heartbeat .................................. Green LED
Host A, B, C Data Detect............................Yellow LED
Channel 1–16 Data Detect .........................Yellow LED
Channel 1-16 Line Status
Test Switch..........................................Red/Green LED
Protection........................Certified Limited Power Source
NEC Class 2 Internal primary current fuse Inrush limiting DC isolation
Cable to transformer .......................................5m (16.5ft)
18 AWG, 3-conductor
Input Connector............. Euro-style 3-pin removable plug
5.06mm (0.2in) terminal block
Surge Protection ...................... Transguard rated at 60V,
250A, 1.5 Joules Gas discharge tube impulse rated at 10kA
Design Tolerance:
Input voltage minimum 11V DC or AC without drop out Input voltage >36V DC or AC may damage equipment
Input frequency............................................... 47–63Hz
Allowable drop out............................................. 150ms
Power connector pin assignments:
Pin Label Notes
1 and 3
2 Ground
12V – 30V
AC/DC
Connect 12–30V AC or DC power to these pins in any polarity
Used for surge protection and data line shields
LED Condition Meaning
Constant green, Blinking red
Constant green, red off “Data In” – shorted to ground
Constant red, Blinking green
Blinking red, Green off “Data In” + shorted to ground
Both LEDs off “Data In” + and – wires shorted
RS-422 / RS-485 DISTRIBUTION PANEL 8200-0712-02, REV. E INSTALLATION GUIDE
RS-422 line correctly wired
“Data In” + and – wires reversed
or open
2 of 4
Loading...
+ 2 hidden pages