American Dynamics AD2032 Specsheet

FEATURES
The AD2096 Series Alarm Interface Unit converts sixty-four hardwire alarm inputs to AD alarm contact numbers for use by American Dynamics Matrix Switcher/Controller systems. The matrix switcher/controller systems can be programmed to automatically switch video inputs to video outputs, display presets, and activate auxiliary outputs in response to activated alarm inputs. A single Form C relay and LED indicate when any of the sixty-four alarm contacts are activated. DIP switches are used to select alarm input groups (in blocks of sixty-four), to set acceptance of normally-open or normally-closed alarms (in groups of eight), and to set the baud rate of the RS-232 link. Multiple units can be cascaded on a single RS-232 system port. The universal mount enables the unit to be mounted to the front or rear of equipment racks, or flat on a wall or horizontal surface.
The AD2032 Series Alarm Responder provides thirty-two addressable double pole Form A relays arranged in two groups of sixteen. The Alarm Responder provides relay contact closures for corresponding video outputs that are displaying alarm actions. Each relay group can be programmed to respond to two separate groups of sixteen contiguous video outputs. Relays can activate VCRs, annunciators, or other external alarm associated devices. The unit is used with MegaPower™ Series Matrix Switcher/Controller Systems via High Speed Data Line or AD Manchester code line. The universal mount enables the unit to be mounted to the front or rear of equipment racks, or flat on a wall or horizontal surface.
AD2096 and AD2032 Series
ALARM ACCESSORIES
AD2096 Series Alarm Interface Unit
Input of 64 hard-wired alarms
Multiple units cascadable on a single RS-232 link
Enables the system to automatically respond to external inputs
Diagnostic LEDs
Alarm presence indication
Provides single relay output
Universal wall, surface, or rack mount
AD2032 Series Alarm Responder
Activates relays that correspond to video outputs in alarm
32 addressable Form-A relays
Relays can activate VCRs, annunciators, or other external alarm devices
Diagnostic LEDs
Universal wall, surface, or rack mount
www.americandynamics.net
SPECIFICATIONS
Model Numbers
AD2096A . . . . . . . . . . . . . . . . . . . . .Alarm Interface Unit,120 VAC, 50/60 Hz
AD2096-1 . . . . . . . . . . . . . . . . . . . .Alarm Interface Unit, 230 VAC, 50/60 Hz
AD2032 . . . . . . . . . . . . . . . . . . . . . .Alarm Responder, 120 VAC, 50/60 Hz
AD2032-1 . . . . . . . . . . . . . . . . . . . .Alarm Responder, 230 VAC, 50/60 Hz
Operational (Alarm Interface Unit)
Alarm Inputs . . . . . . . . . . . . . . . . .64 contact closures (closures to ground or
0 V to 5 V logic levels), N/O or N/C,
Programmable in blocks of 8
Address Range . . . . . . . . . . . . . . . .16 blocks of 64 for maximum of 1024
Alarm Outputs . . . . . . . . . . . . . . .RS-232 RJ-45 direct connection to system
CPU
Alarm Indication . . . . . . . . . . . . . .LED, and Form-C relay outputs
LEDs . . . . . . . . . . . . . . . . . . . . . . . . .Power and alarm
Operational (Alarm Responder)
Alarm Outputs . . . . . . . . . . . . . . .32 Form-A relays, 2 groups of 16 outputs
Address Range . . . . . . . . . . . . . . . .Blocks of 16
LEDs . . . . . . . . . . . . . . . . . . . . . . . . .Power and data
Matrix Switcher . . . . . . . . . . . . . . .AD High Speed Data Line or Manchester
code connection
Connectors (Alarm Interface Unit)
RS-232 . . . . . . . . . . . . . . . . . . . . . . .RJ-45 in/out, cascadable
Alarm Inputs . . . . . . . . . . . . . . . . .Eleven 12-pin removable screw terminals
Connectors (Alarm Responder)
AD High Speed Data Line . . . . .BNC, in/out
AD Manchester Code . . . . . . . . . .One 12-pin removable screw terminal
Alarm Output . . . . . . . . . . . . . . . .Eight 12-pin removable screw terminals
Electrical
Supply Voltage
AD2096A, AD2032 . . . . . . . . .120 VAC, 50/60 Hz
AD2096-1, AD2032-1 . . . . . . .230 VAC, 50/60 Hz
Power . . . . . . . . . . . . . . . . . . . . . . . .8 watts (nominal)
Mechanical
Mounting . . . . . . . . . . . . . . . . . . . .Universal wall, surface, and rack mount
(19-inch EIA)
Dimensions (H x W x D) . . . . . . .89 x 483 x 203 mm
(3.5 x 19 x 8 in)
Unit Weight . . . . . . . . . . . . . . . . . .4.5 kg (10 lbs)
Shipping Weight . . . . . . . . . . . . . .4.5 kg (10 lbs)
Environmental
Operating Temperature . . . . . . . .0°to 40°C (32° to 104° F)
Storage Temperature . . . . . . . . . .-40°to 70° C (-40° to 155°F)
Humidity . . . . . . . . . . . . . . . . . . . . .98% RH (non-condensing)
Regulatory
Immunity . . . . . . . . . . . . . . . . . . . .EN50130-4
Safety . . . . . . . . . . . . . . . . . . . . . . . .UL2044
Compatible Matrix Switcher/Controller Systems
MegaPower 1024 Series MegaPower 168 Series MegaPower 48 Series AD2150 Series
Basic System Diagram
AMERICAN DYNAMICS AD2096 AND AD2032 SERIES ALARM ACCESSORIES
VS289-02 01/03 L
©2003 Sensormatic Electronics Corporation
Product specifications and availability subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies.
ENTER AUXILIARY
IRIS
FOCUS
ZOOM
CAMERAMONITORSTATUS PRESET
AD2096 Series
Matrix Switcher/Controller
VCR
DVR
AD2032 Series
RS-232 Lines
High Speed Data Line
or
Control Code Line
Monitor Displaying Alarm Camera
AD2088 Operator Keyboard
Alarm Contact Activated By Open Door
Loading...