N E W ! Supports SensorNet, Manchester, and RS-422 dome control
protocols directly from the CPU without the need for additional
accessories
NEW! Integrate SpeedDome Programmable Dome Camera alarms
utilizing SensorNet and duplex RS-422 protocols
NEW! Enhanced salvo functionality with new view programming
option
NEW! Programming options for setting date/time including Daylight
Saving Time (DST)
Scalable, high-density modular architecture for easy expansion
Supports up to 3,200 video inputs, 256 outputs, and 128 keyboards
Dual CPU mode provides inherent passive hot switch failover for
system reliability
Synchronize time to Network Time Protocol (NTP) for integration with
other devices on the network
Store snapshots of important scenes on your network
Windows®-based system management software provides a
powerful tool for remote configuration and monitoring
Customize your workstation experience with powerful macros
Keep a watchful eye with video presets, patterns, tours, and salvos
Control recorded video just as easily as live – even switching from
one to the other with a simple keystroke
2
1
MegaPower 3200 is a modular, scalable video matrix
switcher/controller system designed for the largest and most
sophisticated users of CCTV such as airports, corporate or
government complexes, casinos, and large medical centers.
Start with a single CPU and switcher bay and easily expand
by adding switcher bays for more inputs and outputs. Dual
CPU mode provides redundant CPU backup protection with
fault detection and hot switch failover to ensure uninterrupted
system operation. Achieve a full cross-point video matrix
of up to 38,528 video inputs by 256 video outputs with a
satellite connection of up to 30 systems. MegaPower 3200 is
maintenance and user-friendly, letting you easily swap out the
CPU, video input and video output modules without removing
system cables. Plus, an LCD displays CPU status while LED
indicators provide information on port activity.
With powerful user-defined macros, you can customize
®
American Dynamics
matrix keyboards3 to perform a
multitude of system tasks via simple, easy to remember
keystrokes.
(1) Requires port expanders and dual mode CPU
(2) Feature supported with AD2089 keyboard and Network Client v4.04 and higher
(3) Supports ControlCenter 1100 and AD2089 keyboards
MegaPower 3200 connects seamlessly to your network to
enable PC-based configuration, firmware updates, activity
logging, snapshots, time synchronization, and email text
messaging. In addition, you can send activity logs and reports
of user control, alarms, and configuration changes to any PC
on the network.
As an essential part of the powerful American Dynamics
Enterprise Surveillance Solution, MegaPower 3200 enables
you to switch back and forth between live and recorded video
using the same keyboard and monitor. By integrating with
Network Client Remote Management Software, users can
®
achieve important Intellex
digital video management system
functionality such as camera playback, tours, and salvos
using the same CCTV keyboard and monitor.
features
Easy to Configure and Use
MegaPower 3200 uses an Enhanced Administration System
(EASY) configuration and monitoring software tool to retrieve,
archive, and load back MegaPower CPU data. It provides
IP network connection to all satellite systems and can
concurrently update dual mode CPUs.
In addition to the powerful macros that allow you to customize
your keyboards, MegaPower 3200 also lets you control
standard video recorder functions such as play, stop, pause,
record, rewind, and fast-forward directly from any suitably
equipped keyboard. Similarly, you can control fixed or
variable-speed domes, pan/tilts, motorized lenses, auxiliary
outputs, and 72 presets per video input at camera sites. For
each video input, you can assign a 4-digit number to replace
the default video input number. This can aid in identifying
specific locations in applications like multiple level buildings or
satellite configurations.
Selectable on-screen display enables you to display the
date/time, video input number and title, site number and title,
and monitor status. Set the date/time directly using system
keyboards in three date formats (MM/DD/YY, DD/MM/YY, or
YY/MM/DD) and configure beginning and end date/time for
Daylight Saving Time within the EASY CPU application. The
user can turn the following displays on and off: video input
number and monitor status, video input title, and date/time
displays. Text controls include incremental horizontal/vertical
positioning and display brightness. When attempting to control
a dome/PTZ, each monitor can also display which user or
keyboard of equal or higher priority has control or has locked
the camera.
Scalable and Flexible for a
Future-Proof System
MegaPower 3200 is available pre-packaged in any
combination of 16 video inputs and 4 video output increments
up to a maximum of 3200 video inputs, by 256 video outputs.
Expanded satellite systems interconnect up to 30 systems.
System flexibility is further enhanced by defining authorized
access to keyboards, video inputs and video outputs.
Partitioning can also be used to limit access to remote
systems.
RS-232 ports allow standard communication with keyboards,
alarm interface units, satellite system CPUs, recorder control
devices, third party interfaces, computers, etc. Each port is
individually programmable for standard data rates from 300
to 38,400 BPS. Each port can expand to four ports with the
optional port expander.
Ensuring the Most Vigilant Security
MegaPower 3200 supports universal system and individual
monitor tours for consistent surveillance. A tour is a sequence
of video inputs with each input featuring an individual dwell
time, a preset/pattern, and an auxiliary action. Tours can run
forward or in reverse.
Salvo switching allows multiple video inputs to be called
simultaneously to multiple contiguous video outputs. Two
hundred individual groups (salvos), consisting of up to 16
video inputs (each with a preset and an auxiliary action) can
be called either manually or as part of a tour and can be
programmed from one through 9999.
There are 35 user-programmable times available that can be
independently designated for multiple days of the week to call
universal tours to video output(s). Event timers also enable you
to activate and deactivate alarm contacts.
Integrate SpeedDome Programmable Dome Camera alarms
utilizing SensorNet and duplex RS-422 protocols. Alarms can
be programmed to call a video input or groups of video inputs
to any one or more video outputs. Custom text messages can
be displayed on alarming monitors. A preset, auxiliary action,
and individual dwell time may be defined for each alarm input.
Any of 25 alarm display/clearance methods may be selected
independently for each video output. Clear alarms from a
configured block of monitors using Normal, Automatic, or
Instant alarm clearing methods for convenient, effective alarm
management.
Easily Monitor Activity and Permissions
Log the occurrence and removal of all alarm and video loss
events on a networked PC. An alarm event message includes
date/time of event, contact number, video input number, and
alarm status. Video loss messages include date/time, video
input number, video loss status, synchronization loss status,
and detection mode. Optional internal video loss detection
alerts an operator to the complete or partial loss of each video
input. Advanced detection circuitry detects loss of video sync
or 25%, 50%, 75% loss of video signal for each input
Keyboards or users can be assigned one of eight levels
of priority control of remote camera sites. Up to 64 user
codes, each with a unique password, can be assigned to
operators. Access to certain system features may be restricted
depending on a user’s priority level.
4
.
(4) Requires AD2010DBVL module(s)
System Components
Central Processing Unit
ADMPCPU ................. MegaPower CPU for MP 3200 systems,
ADACQORJ45 ..............Quick on RJ45 connector for easy
Switcher Bays
AD2010N ..................Standard Matrix Bay, 120 VAC, UL & CSA
AD2020N ..................Bi-Level Matrix Bay, 120 VAC, UL & CSA
AD2010P . . . . . . . . . . . . . . . . . . Standard Matrix Bay, 100-240 VAC, CE
ADACSNETD, ADACSNETDP
SensorNet/Manchester
Distribution Panel
ADAC422D, ADAC422DP
RS-422/RS-485
Distribution Panel
AD2091, AD2091-1 ..........
Manchester Code
Generator/Distributor
AD2083-02C, . . . . . . . . . . . . . .
AD2083-02C-1 RS-422
Generator/Distributor
AD2096A, . . . . . . . . . . . . . . . . .
AD2096-1 Alarm Interface
AD2031, . . . . . . . . . . . . . . . . . .
AD2031-1 Switcher Follower
AD2032, . . . . . . . . . . . . . . . . . .
AD2032-1 Alarm Responder
AD2033, . . . . . . . . . . . . . . . . . .
AD2033-1 Auxiliary Follower
Full system keyboards allow for video switching, pan/
tilt control, dome control, auxiliary control, macro
and recorder control (ADCC1100 and AD2089 only),
and system programming. The keyboards support
bi-directional communication with the ADMPCPU via
RS-232 ASCII commands.
Expands one RS-232 port on a system into
four ports. This provides connections to multiple
system keyboards.
Amplifies and distributes SensorNet or Manchester
...
signals and provides Host A and B inputs for dual
CPU systems and 16 output ports with dual
connectors for home run, daisy chain, star, and
J-Box wiring topologies.
Amplifies and distributes RS-422/485 signals and
......
provides Host A and B inputs for dual CPU systems
and 16 outputs for home run, daisy chain, star, and
J-Box wiring topologies.
Interfaces with the matrix switcher/controller system
via AD Data Line and provides 64 AD Manchester
code outputs for use by receiver/drivers and
suitably-equipped pan/tilts and domes.
Interfaces with the matrix switcher/controller system
via AD Data Line and provides 16 SEC RS-422
outputs for use by suitably equipped domes.
Supervises up to 64 alarm inputs and provides
RS-232 ASCII alarm commands to the system.
Alarm inputs can be programmed to call any video
input, display any preset, or to initiate any auxiliary
action. Up to 16 units can be cascaded on a single
RS-232 line.
Activates relays when designated video inputs are
called to designated video outputs. It interfaces with
the matrix switcher/controller system and provides
up to 32 Form A relays, via AD Data Line, that can
be grouped in series and addressed to a single video
output, or in two groups of 16 relays for two specific
video outputs.
Activates relays when associated video outputs are
in their alarming condition. Interfaces with matrix
switcher/controllers and provides up to 32 Form A
relays via AD Data Line.
Activates relays when a specific auxiliary
is triggered either manually or automatically for an
associated video input. Interfaces with matrix
switcher/controllers and provides up to 32 Form A
relays via AD Data line.
Model Number Configurator
The configuration tool adds
flexibility to any job, allowing
change as the customers’
requirements change.
Pre-configured systems from
4 to 128 outputs include one
MPCPU; pre-configured
systems >128 outputs include
two MPCPU.
“blank” = standard system
“–” = standard BNC inputs on VIM Back Panels
“S” = all VIM4 & Remote Panels (30” cables)
“L” = all VIM4 & Remote Panels (96” cables)
ADMPRV xxxx - yyy 1
“V” = factory installed
video loss
# of inputs, increments
of 16, up to 3200
(i.e. 16, 32...3200)
# of outputs, increments of 4,
up to 256 (i.e. 4, 8...256)
“N” = 120 VAC (+or - 10%),
“P” = 100-240 VAC, 50-60 Hz, CE
50-60 Hz, UL & CSA
(5) Includes AD2016CB 30” (76 cm) cables.
SPECIFICATIONS
Basic System Diagram
The MegaPower 3200 matrix switcher supports up to 3200 video
inputs, 256 video outputs, 128 keyboards, 4096 alarms, and 30
satellite systems. The MP3200 provides Intellex control using the
Connectors
Video Inputs .............. 0.5 to 2.0 Vp-p, composite BNC,
Video Outputs ............4 – 256, 1 Vp-p, composite BNC
RS-485/RS-232 ........... Sixteen or thirty-two 8-pin modular. Optional port
AD2089 keyboard and Network Client software, and hot switch
capabilities using a second MPCPU unit....with no hot switch
accessory unit required. The EASY configuration and monitoring
software allows remote configuration and monitoring.
Communication
Dome Protocols ........... Sensornet, RS-422, Manchester (with external
Alarm Inputs .............. 4,096 via AD2096, AD2083, SensorNet/duplex
Relay Outputs .............Optional with external accessories
Electrical
Power Requirements .......
Video Outputs
Fixed Cameras,
Intellex
EASY CPU Setup
and Programming
MegaPower 3200
Alarm Inputs
SpeedDomes or
Mini-Domes
ADTTE Touch Tracker,
ControlCenter 1100,
200, 300, and AD2089
Keyboards
Mechanical
Mounting ................19-inch rack mount
Dimensions (H x W x D) .....
Unit Weight ...............
Color ...................Black
Environmental
Operating Temperature ......0˚ to 40˚C (32˚ to 104˚F)
Humidity .................0 to 95% RH (noncondensing)
Storage .................-40˚ to 70˚C (-40˚ to 155˚F)
Regulatory
Operational
Bandwidth ...............17 MHz
Frequency Response .......± 0.5 dB to 12 MHz
S/N Ratio ................≥ 65 dB (Vp-p vs. Vrms noise)
Crosstalk
Adjacent Channels ........≤ 55 dB (at 3.58 MHz)
Input to Input ............≤ 70 dB (at 3.58 MHz)
Differential Delay ...........± 1.0˚
Differential Phase ..........≤ 1.5˚
Differential Gain ...........≤ 1.0%
Tilt .....................≤ 0.5%
Gain ....................Unity ± 1 dB
Return Loss (input/output) ...≥ 40 dB
DC Level (video signal) ......0 volts
Switching ................ Complete switching of cross-point matrix. EIA
Switching Speed ..........≤ 20 ms (typical)
Keyboard/Receiver
Control Time ..............20 ms (typical)
Phase Adjustment .........180° vertical interval adjustment for switching bay
Non-volatile Memory ........ Setup information saved in permanent flash
(6) Looping panel is optional: ADULP-30 or ADULP-96
(7) AD2031, AD2032, AD2033
Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all
features. Availability varies by region; contact your sales representative. Certain product names mentioned herein may be trade names and/or
registered trademarks of other companies.