American Dryer Corp AD-20 User Manual

AD-20
Installation Manual
W ARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other appliance.
— WHA T TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building or area of all occupants.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
AVERTISSEMENT: Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
— Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.
— QUE F AIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
Ne pas tenter d’allumer d’appareils.
Ne touchez à aucun interrupteur . Ne pas vous servir des téléphones se trouvant dans le bâtiment.
Évacuez la pièce, le bâtiment ou la zone.
Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incendies.
— L ’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz.
For replacement parts, contact the reseller from which the dryer
was purchased or
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781 U.S.A.
T elephone: (508) 678-9000 / Fax: (508) 678-9447
www.amdry.com
080902GS/mcronan ADC Part No. 113379
Retain This Manual In A Safe Place For Future Reference
American Dryer Corporation products embody advanced concepts in engineering, design, and safety. If this product is
properly maintained, it will provide many years of safe, efficient, and trouble-free operation.
ONLY qualified technicians should service this equipment.
OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the dryer.
The following “FOR YOUR SAFETY” caution must be posted near the dryer in a prominent location.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
W e have tried to make this manual as complete as possible and hope you will find it useful. ADC reserves the right to make changes from time to time, without notice or obligation, in prices, specifications, colors, and material, and to change or discontinue models. The illustrations included in this manual may not depict your particular dryer exactly.
POUR VOTRE SÉCURITÉ
Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.
Important
For your convenience, log the following information:
DA TE OF PURCHASE________________________________ MODEL NO. __________________________________________
RESELLER’S NAME ________________________________________________________________________________________
Serial Number(s) ________________________________________________________________________________________
AD-20
________________________________________________________________________________________
________________________________________________________________________________________
Replacement parts can be obtained from your reseller or the ADC factory . When ordering replacement parts from the factory , you can F AX your order to ADC at (508) 678-9447 or telephone your order directly to the ADC Parts Department at (508) 678-9000. Please specify the dryer model number and serial number in addition to the description and part number, so that your order is processed accurately and promptly.
“IMPORT ANT NOTE TO PURCHASER”
Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas. These instructions must be posted in a prominent location near the dryer .
IMPORTANT
YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPL Y AND THE GAS SUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA
(Occupational Safety and Health Administration) STANDARDS.
«Attention: Au moment de l’entretien des “Caution: Label all wires prior to disconnection when servicing controls. W iring errors can cause improper operation.”
commandes, étiquetez tous les fils avant de
les débrancher. Des erreurs de câblage
peuvent entraîner un fonctionnement
inadéquat et dangereux.»
CAUTION
DR YERS SHOULD NEVER BE LEFT UNA TTENDED WHILE IN OPERA TION.
WARNING
CHILDREN SHOULD NOT BE ALLOWED TO PLA Y ON OR NEAR THE DRYER(S). CHILDREN
SHOULD BE SUPER VISED IF NEAR DRYERS IN OPERA TION.
FOR YOUR SAFETY
DO NOT DR Y MOP HEADS IN THE DRYER. DO NOT USE DR YER IN THE PRESENCE OF DR Y CLEANING FUMES.
WARNING
UNDER NO CIRCUMST ANCES should the dryer main door switch, lint drawer switch, or the heat circuit devices ever be disabled.
WARNING
The dryer must never be operated with the back guard removed. PERSONAL INJURY OR FIRE COULD RESUL T .
WARNING
DRYER MUST NEVER BE OPERA TED WITHOUT THE LINT FIL TER/SCREEN IN PLACE.
IMPORTANT
PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer.
Dryers must not be installed or stored in an area where it
will be exposed to water or weather.
Table of Contents
SECTION I
IMPORTANT INFORMATION ............................................................................... 3
A. Receiving and Handling ................................................................................................................. 3
B. Safety Precautions ........................................................................................................................ 4
SECTION II
SPECIFICATIONS .................................................................................................... 6
A. Specifications ............................................................................................................................... 6
SECTION III
INSTALLATION PROCEDURES ........................................................................... 8
A. Unpacking/Setting Up................................................................................................................... 8
B. Location Requirements ................................................................................................................. 9
C. Dryer Enclosure Requirements .................................................................................................... 10
D. Fresh Air Supply Requirements ................................................................................................... 11
E. Exhaust Requirements ................................................................................................................. 12
F. Electrical Information .................................................................................................................. 14
G . Gas Information .......................................................................................................................... 20
H. Preparation For Operation/Start-Up ........................................................................................... 24
I. Preoperational T ests ................................................................................................................... 25
J. Shut Down Instructions ............................................................................................................... 26
SECTION IV
SERVICE/PARTS INFORMATION ......................................................................27
A. Service ....................................................................................................................................... 27
B. Parts .......................................................................................................................................... 27
SECTION V
WARRANTY INFORMATION .............................................................................. 2 8
A. Returning W arranty Cards........................................................................................................... 28
B. Warranty .................................................................................................................................... 28
C. Returning Warranty Parts ............................................................................................................ 28
SECTION VI
ROUTINE MAINTENANCE .................................................................................. 30
A. Cleaning ..................................................................................................................................... 30
SECTION VII
DATA LABEL INFORMATION............................................................................. 3 2
A. Data Label ................................................................................................................................. 32
SECTION I
IMPORTANT INFORMA TION
A. RECEIVING AND HANDLING
The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery , the dryer and packaging, and wooden skid should be visually inspected for shipping damage. If any damage whatsoever is noticed, inspect further before delivering carrier leaves.
Dryers damaged in shipment:
1.
ALL dryers should be inspected upon receipt and before they are signed for.
2. If there is suspected damage or actual damage, the trucker’s receipt should be so noted.
3. If the dryer is damaged beyond repair, it should be refused. Those dryers, which were not damaged in a damaged shipment, should be accepted, but the number received and the number refused must be noted on the receipt.
4. If you determine that the dryer was damaged after the trucker has left your location, you should call the delivering carrier’s freight terminal immediately and file a claim. The freight company considers this concealed damage. This type of freight claim is very difficult to get paid and becomes extremely difficult when more than a day or two passes after the freight was delivered. It is your responsibility to file freight claims. Dryer/parts damaged in transit cannot be claimed under warranty.
5. Freight claims are the responsibility of the consignee, and ALL claims must be filed at the receiving end. ADC assumes no responsibility for freight claims or damages.
6. If you need assistance in handling the situation, please contact the ADC Traffic Manager at (508) 678-9000.
IMPORTANT: The dryer must be transported and handled in an upright position at ALL times.
3
B. SAFETY PRECAUTIONS
WARNING: For your safety , the information in this manual must be followed to minimize the risk of
fire or explosion or to prevent property damage, personal injury , or loss of life.
WARNING: The dryer must never be operated with the back guard removed. PERSONAL
INJURY OR FIRE COULD RESUL T .
1. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
2. Purchaser/user should consult the local gas supplier for proper instructions to be followed in the event the
user smells gas. The instructions should be posted in a prominent location.
3. WHAT TO DO IF YOU SMELL GAS...
a. DO NOT try to light any appliance.
b. DO NOT touch any electrical switch.
c. DO NOT use any phone in your building.
d. Clear the room, building, or area of ALL occupants.
e. Immediately call your gas supplier from a neighbor’ s phone. Follow the gas supplier’s instructions.
f. If you cannot reach your gas supplier, call the fire department.
4. Installation and service must be performed by a qualified installer, service agency, or gas supplier.
5. Dryer(s) must be exhausted to the outdoors.
6. Although ADC produces a very versatile dryer, there are some articles that, due to fabric composition or cleaning method, should not be dried in it.
WARNING: Dry only water washed fabrics. DO NOT dry articles spotted or washed in dry
cleaning solvents, a combustible detergent, or “all purpose” cleaner .
EXPLOSION COULD RESUL T.
WARNING: DO NOT dry rags or articles coated or contaminated with gasoline, kerosene, oil, paint,
or wax. EXPLOSION COULD RESUL T.
4
WARNING: DO NOT dry mop heads. Contamination by wax or flammable solvents will create a
fire hazard.
WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber , or
similarly textured rubber materials. Drying in a heated basket (tumbler) may damage plastics or rubber and may be a fire hazard.
7. A program should be established for the inspection and cleaning of lint in the exhaust ductwork and area
around the back of the dryer. The frequency of inspection and cleaning can best be determined from experience at each location.
WARNING: The collection of lint in the exhaust ductwork can create a potential fire hazard.
8. For personal safety, the dryer must be electrically grounded in accordance with local codes and/or the
National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
NOTE: Failure to do so will VOID THE WARRANTY.
9. UNDER NO CIRCUMSTANCES should the dryer main door switch, lint drawer switch, or the heat
circuit devices ever be disabled.
WARNING: PERSONAL INJURY OR FIRE COULD RESUL T .
10. This dryer is not to be used in the presence of dry cleaning solvents or fumes.
11. Remove articles from the dryer as soon as the drying cycle has been completed.
WARNING: Articles left in the dryer after the drying and cooling cycles have been completed can
create a fire hazard.
12. READ AND FOLLOW ALL CAUTION AND DIRECTION LABELS ATTACHED TO THE
DRYER.
WARNING: YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPL Y AND
THE GAS SUPPL Y BEFORE ANY COVERS OR PANELS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING , ADJUSTING , INST ALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS.
5
SECTION II
SPECIFICATIONS
A. SPECIFICATIONS
MAXI MUM C AP AC ITY (D RY WEIGHT) 20 lbs 9 kg BAS K ET ( TUM BLER) DIA METER 2 5. 7 5 ” BASK ET (TUMBLER) DEPTH 24” BAS K ET ( TUM BLER) MOTOR 1 /4 HP BLO W ER M O TOR 1 /8 HP BAS K ET ( TUM BLER) VOLUM E 7 .5 c u. ft. VENT CONNECTION 4” C ABI N ET WID TH 2 7” C ABI N ET D EP TH 3 0” C ABIN ET HEIGHT 41 ”
VO LTAGE AVAILABLE HEAT INPUT 40,000 btu/hr
Gas
AIRF LO W 24 0 cfm
120v /60 Hz/1ø, 240v/60 Hz/1ø,
65.4 cm
60.95 cm
0.19 kw
0.1 kw
0.21 cu.m.
10.2 cm
68.6 cm
76.2 cm 104 cm
240v/50 Hz/1ø
10,080 kcal/hr
6.79 cmm
INLET PIPE CONNECTION 3/8” N.P.T.
O VEN S I ZE
VO LTAGE AVAILABLE
Electric
Shaded areas are stat ed i n metri c equival ent s
* Contact factory for information not listed, 3-phase (3ø) figures shown are for 4-wire service, non-reversing.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
6
1ø 3ø
240v/60 Hz/1ø, 240v/50 Hz/1ø,
416v/50 Hz/3ø
5.4 kw
8.1 kw
Specifications
AD-20
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
7
SECTION III
INSTALLATION PROCEDURES
Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National S tandards: ANSI Z223.1­LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electrical Code) or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing) or Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION (for Electrical Connections).
A. UNPACKING/SETTING UP
Remove protective shipping material (i.e., plastic wrap and optional shipping box) from dryer.
IMPORTANT: Dryer must be transported and handled in an upright position at ALL times.
The dryer can be moved to its final location while still attached to the skid or with the skid removed. T o unskid the dryer, locate and remove the two (2) bolts securing the base of the dryer to the wooden skid.
With the skid removed, to make it easier to slide the dryer into its final position, slightly lower ALL four (4) leveling legs, so that the dryer will slide on the legs instead of the base frame.
8
Loading...
+ 26 hidden pages