American DJ®
Rampage
Introduction:
Thank you for purchasing the Rampage™ DMX controller from
American DJ®. To optimize the performance of this product,
please read these operating instructions carefully to familiarize
yourself with the basic operations of this unit. The American DJ®
Rampage™ is a unique intelligent moon ower. This unit can be
controlled by a standard DMX controller or can be linked together
with several unit to form a synchronized light show. The Rampage
comes with 16 gobos plus a spot, several of the gobos have multicolor combinations. This unit has been tested at the factory before
being shipped to you, there is no assembly required.
Customer Support:
American DJ provides a toll free customer support line, to provide
set up help and to answer any question should you encounter
problems during your set up or initial operation. You may also visit
us on the web at www.americandj.com for any comments or suggestions.
Service Hours are Monday through Friday 10:00 a.m. to 5:00 p.m.
Pacic Time.
Voice: (800) 322-6337
Fax: (323) 582-2610
E-mail: support@americandj.com
User Instructions
American DJ Supply
4295 Charter Street
Los Angeles Ca. 90058
(323) 582-2650
(323) 582-2610
www.americandj.com
Warning!
To prevent or reduce the risk of electrical shock or re, do not
expose this unit to rain or moisture. Clearing memory often may
cause damage to the memory chip, be careful not to re initialize
your unit frequency often to avoid this risk. Only use the recommended AC/DC power adaptor.
Caution!
There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service,
please contact your nearest American DJ dealer.
©American DJ Supply® www.americandj.com Rampage Instruction Manual Page 2
Set Up:
1
2
3
1
2
3
DMX +
DMX -
COMMON
DMX512 IN
(X-CALIBUR)
CONNECTOR
3 PIN
DMX512 OUT
CONTROLLER
CONNECTOR
3 PIN
1
2
3
Termination reduces signal errors and
avoids signal transmission problems
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and
avoids signal transmission problems
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
Power Supply: Before plugging your unit in be sure the source volt-
age in your area matches the required voltage for your American DJ®
Rampage.™ The Rampage™ is available in a 115v and 230v version.
Because line voltage may vary from venue to venue, you should be sure
to plug your power supply into a matching wall outlet before attempting
to operate you controller.
Data Cable (DMX Cable) Requirements:
Your xture and your controller require a
standard 3-pin XLR connector for data
input and data output (Figure 1). If you
are making your own cables be sure
to use standard two conductor shielded
cable (This cable may be purchased at
almost all pro sound and lighting stores).
Your cables should be made with a male
and female XLR connector on either end
of the cable. Also, remember that DMX
cable must be daisy chained and can
not be “Y”ed or split.
Notice: Do not use the ground lug on the XLR connector. Do
not connect the cable’s shield conductor to the ground lug or allow
the shield conductor to come in contact with the XLR’s outer casing.
Grounding the shield could cause a short circuit and erratic behavior.
Figure 1
Special Note: Line Termination.
When longer runs of cable
are used, you may need to use a terminator on the last unit to avoid
erratic behavior. A terminator is a 90 - 120 ohm 1/4 watt resistor which is
connected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This unit is inserted in the female XLR connector of the last
Linking:
Your Rampage comes with several built in programs. These programs
will automatically run to the beat of music. For a more dramatic effect
link several Rampage units together. Each Rampage can act a “Master
Unit” that can control up to 15 more units. Link the units together using
standard DMX cable. Follow the Master/Slave Dip Switch Chart on page
7 for proper dip switch settings. The built programs are optimized for a
four unit chase.
XLR FEMALE SOCKET
1 EARTH
3 HOT
XLR Pin Configuration:
Pin 1 = Shield
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
1 EARTH
XLR MALE SOCKET
2 HOT
2 COLD
COLD 2
Figure 3
©American DJ Supply® www.americandj.com Rampage Instruction Manual Page 3
Figure 2
©American DJ Supply® www.americandj.com Rampage Instruction Manual Page 4