American DJ PAR Z100 5K operation manual

PAR Z100 5K
©2017 ADJ Products, LLC all rights reserved. Information,
specications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of their
respective companies.
ADJ Products, LLC and all aliated companies hereby dis­claim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, unsucient and negligent as­sembly, installation, rigging, and operation of this product.
9/17
User Instructions
DOCUMENT VERSION
Please check www.adj.com for the latest revision/update of this guide.
Date
09/27/17
Europe Energy Saving Notice Energy Saving Matters (EuP 2009/125/EC) Saving electric energy is a key to help protecting the enviroment. Please turn o all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!
Document
Version
1 1.0
Software
Version
DMX
Channel
>
Mode
1/2/3 Initial Release
Notes
Par Z100 5K General Instructions Par Z100 5K General Information
Unpacking: Thank you for purchasing the Par Z100 5K by ADJ Prod-
ucts, LLC. Every Par Z100 5K has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the ship­ping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your xture for any damage and be sure all equipment necessary to operate the unit has arrived intact. In the event damage has been found or parts are miss­ing, please contact our toll free customer support number for further instructions. Please do not return this unit to your dealer without con­tacting customer support rst.
Introduction: The P
LED par fixture. The Par Z100 5K also operates as a stand alone fixture. This fixture is suitable for theaters, studios, retail stores, and other similar locations. For best results use fog or special effects
smoke to enhance the beams projections.
ar Z100 5K is a DMX intelligent, zooming,
Customer Support: ADJ Products, LLC provides a toll free cus-
tomer support line, to provide help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.adj.com for any comments or suggestions. Service Hours are Monday through Friday 8:00 a.m. to 4:30 p.m. Pacic Standard Time.
Voice: (800) 322-6337 Fax: (323) 582-2941 E-mail: support@americandj.com
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Warning! This may cause severe eye damage. Avoid looking directly
into the light source at all times!
To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference.
Par Z100 5K Features
• DMX-512 Protocol Compatible (3 DMX Channel Modes: 1 Channels, 2 Channels, & 3 Channels)
• 5-Pin XLR In/Out Connections
• powerCON In/Out Connections
• 5 Dimmer Curves (Standard, Stage, TV, Architectural, & Theatre)
• Digital Display for Address and Function Setting
• Gamma Correction Adjustment
• Dimming Frequency Adjustment
• Multiple Unit Power Linking (See page 18)
Par Z100 5K Warranty Registration
The Par Z100 5K carries a 2 year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase and war-
ranty. You may also register your product online at www. adjproducts. com. All returned service items whether under warranty or not, must
be freight pre-paid and accompany a return authorization (R.A.) num­ber. If the unit is under warranty you must provide a copy of your proof of purchase invoice. Please contact ADJ Products, LLC cus­tomer support for a R.A. number.
Par Z100 5K Handling Precautions
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact ADJ Products, LLC.
During operation the housing may become extremely hot. Avoid touching the unit with bare hands while in use.
ADJ Products, LLC will not accept any liability for any resulting dam­ages caused by the non-observance of this manual or any unauthor-
ized modication to this unit.
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 3ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 2
Par Z100 5K Safety Precautions
Par Z100 5K DMX Set Up
For Your Own Personal Safety, Please Read and Understand This
Manual Completely Before You Attempt To Install Or Operate
This Unit!
• To reduce the risk of electrical shock or re, do not expose this unit rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Be sure that the local power outlet match that of the required volt-
age for your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken.
• Do not attempt to remove or break o the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product out-
doors voids all warranties.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience recep-
tacles, and the point where they exit from the appliance.
• Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 19 for cleaning details.
• Heat -This fixture should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when:
A. Objects have fallen, or liquid has been spilled into the appliance. B. The appliance has been exposed to rain or water. C. The appliance does not appear to operate normally or exhibits
a marked change in performance.
Power Supply: The ADJ Par Z100 5K contains a automatic voltage
switch, which will auto sense the voltage when it is plugged into the power source. With this switch there is no need to worry about the cor­rect power voltage, this unit can be plugged in anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. A DMX
controller sends DMX data instructions from the controller to the fix­ture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX
compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. Therefore, the first fixture controlled by the controller could be the last fixture in the chain. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation): The Par Z100 5K can be controlled via DMX-512 proto-
col. The Par Z100 5K three DMX channel modes; 1 channel mode, 2 channel mode, & 3 channel mode. The DMX address is set electronically using the controls on the rear panel of the unit. Your unit and your DMX controller require a approved DMX-512 110 Ohm Data cable for data input and data output (Figure
1). We recommend Accu-Cable DMX cables. If you are making your own cables, be sure to use stan­dard 110-120 Ohm shielded cable (This cable may be purchased at almost all professional sound and
Figure 1
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 5ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 4
Par Z100 5K DMX Set Up
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and avoids signal transmission problems and interference. It is always advisable to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
Par Z100 5K DMX Set Up
lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also remember that DMX cable must be daisy chained and cannot be split.
Notice: Be sure to follow gures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con­nect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behavior.
COMMON
1
DMX512 IN
3
3-PIN XLR
2
Figure 2
XLR Pin Conguration
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
XLR Male Socket
1 Ground
Figure 3
DMX512 OT
3-PIN XLR
2 Cold
3 Hot
1
3
2
XLR Female Socket
2 Cold
DMX +
DMX -
1 Ground
3 Hot
5-Pin XLR DMX Connectors.
This unit use 5-pin DMX-512 data
cables for DATA transmission. 5-pin DMX xtures may be implemented in a 3-pin DMX line. When inserting standard 5-pin data cables in to a 3-pin line a cable adaptor must be used, these adaptors are read­ily available at most electric stores. The chart below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion
Conductor 5-Pin XLR Male (In)3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
Pin 1
Pin 2
Pin 3
Pin 1
Pin 2
Pin 3
Pin 4 - Do Not Use
Pin 5 - Do Not Use
Special Note: Line Termination.
used, you may need to use a terminator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
When longer runs of cable are
nected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 6 ADJ Products, LLC - www.adj.com - Par Z100 5K Instruction Manual Page 7
Termination reduces signal errors and
1
avoids signal transmission problems
3
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
Figure 4
Loading...