instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying
product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection
claimed includes all forms and matters of copyrightable materials and information now allowed by
statutory or judicial law or hereinafter granted. Product names used in this document may be
trademarks or registered trademarks of their respective companies and are hereby acknowledged.
All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of
their respective companies.
ADJ Products, LLC and all aliated companies hereby disclaim any and all liabilities for property,
equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic
loss associated with the use or reliance of any information contained within this document, and/or as
a result of the improper, unsafe, unsucient and negligent assembly, installation, rigging, and operation of this product.
DOCUMENT VERSION
Please check www.adj.com for the latest revision/update of this guide.
Date
01/19/18
Document
Version
11.00
Software
Version
>
DMX
Channel
Mode
Notes
6/7/8/11/12Initial Release
Europe Energy Saving Notice
Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the enviroment. Please turn o all electrical products when
they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power
when not in use. Thank you!
MOD HEX100Table of Contents
Introduction
Features / Warranty Registration / Installation
Safety Precautions
Control Panel Layout
DMX Set Up
DMX Addressing
DMX Channel Modes
System Menu
Operating Instructions
Master-Slave Conguration
UC IR/Airstream IR Control
3
4
5
7
8
10
11
20
21
24
25
Dimmer Curve Chart
Dimensional Drawings
Housing Change / Frost Filter
Power Linking / Trouble Shooting / Cleaning
Warranty
Technical Specications
ADJ Products, LLC - www.adj.com - MOD HEX100 User Manual Page 2
26
27
28
29
30
31
MOD HEX100Introduction
Unpacking: Thank you for purchasing the MOD HEX100 by ADJ Products, LLC. Every MOD HEX100
has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the
shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your xture for any damage and be sure all accessories necessary to operate
the unit has arrived intact. In the case damage has been found or parts are missing, please contact our
toll free customer support number for further instructions. Do not return this unit to your dealer without
rst contacting customer support.
Introduction: The ADJ MOD HEX100 is a DMX intelligent, high powered LED par fixture. This xture
can be used in a stand alone set up or connected in a Master/Slave set up. The MOD HEX100 has
seven operating modes: Sound Active mode, Auto Run mode, Color Change mode, Color Fade mode,
RGBWA+UV Dimmer mode, Static Color mode, and DMX controlled. To optimize the performance of
this product, please read these operating instructions carefully to familiarize yourself with the basic
operations of this unit. These instructions contain important safety information regarding the use and
maintenance of this unit. Please keep this manual with the unit, for future reference.
Customer Support: ADJ provides a customer support line, to provide set up help and to answer any
question should you encounter problems during your set up or initial operation. You may also visit us
on the web at www.adj.com for any comments or suggestions. Service Hours are Monday through
Friday 8:00 a.m. to 4:30 p.m. Pacic Standard Time.
Voice: (323) 582-2650
Fax: (323) 582-2941
E-mail: support@AmericanDJ.com
Warning! To prevent or reduce the risk of electrical shock or re, do not expose this unit to rain or
moisture.
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself,
doing so will void your manufactures warranty. In the unlikely event your unit may require service
please contact ADJ Products, LLC.
PLEASE recycle the shipping carton when ever possible.
ADJ Products, LLC - www.adj.com - MOD HEX100 User Manual Page 3
MOD HEX100Features
• Multi-Colors
• Seven Operating Modes
• Electronic Dimming 0-100%
• Built in Microphone
• DMX-512 protocol
• 3-Pin & 5-Pin DMX Connection
• Five DMX Modes: 6 Channel Mode, 7 Channel Mode, 8 Channel Mode, 11 Channel Mode, and
12 Channel Mode.
• ADJ UC IR compatible and Airstream IR compatible
• Multiple Unit Power Linking (See page 29)
INCLUED:
1 x Scissor Yoke
1 x powerCON Cable
3 x Frost Filters (20/40/60 Degrees)
OPTIONAL ACCESSORIES:
MOD Kit Pearl White Housing Case (Order Code: MOD510)
MOD HEX100Warranty Registration
The MOD HEX100 carries a 2 year limited warranty. Please fill out the enclosed warranty card to
validate your purchase. All returned service items whether under warranty or not, must be freight prepaid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on
the outside of the return package. A brief description of the problem as well as the R.A. number must
also be written down on a piece of paper included in the shipping carton. If the unit is under warranty,
you must provide a copy of your proof of purchase invoice. You may obtain a R.A. number by contacting our customer support team on our customer support number. All packages returned to the
service department not displaying a R.A. number on the outside of the package will be returned to the
shipper.
MOD HEX100Installation
The unit should be mounted using a mounting clamp (not provided), axing it to the mounting
bracket that is provided with the unit. Always ensure that the unit is rmly xed to avoid vibration
and slipping while operating. Always ensure that the structure to which you are attaching the unit is
secure and is able to support a weight of 10 times the unit’s weight. Also, always use a safety cable
that can hold 12 times the weight of the unit when installing the xture.
The equipment must be installed by a professional, and it must be installed in a place where it is out
of the reach of people’s grasp.
ADJ Products, LLC - www.adj.com - MOD HEX100 User Manual Page 4
MOD HEX100Safety Precautions
• To reduce the risk of electrical shock or re, do not expose this unit rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken. Do not attempt to
remove or break o the ground prong from the electrical cord. This prong is used to reduce the risk
of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Never plug this unit in to a dimmer pack
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6”
(15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product outdoors voids all warranties.
• During long periods of non-use, disconnect the unit’s main power.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by
items placed upon or against them, paying particular attention to the point they exit from the unit.
• Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 29
for cleaning details.
• Heat -The appliance should be situated away from heat sources such as radiators, heat registers,
stoves, or other appliances (including amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when:
A. The power-supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the fixture.
C. The fixture has been exposed to rain or water.
D. The fixture does not appear to operate normally or exhibits a marked change in performance.
E. The fixture has fallen and/or subjected to extreme handling.
ADJ Products, LLC - www.adj.com - MOD HEX100 User Manual Page 5
MOD HEX100Safety Precautions
RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET (UV) RADIATION!
FIXTURE EMITS HIGH INTENSITY ULTRAVIOLET (UV) LIGHT
AT A WAVELENGTH OF 399NM - 435NM.
WEAR PROPER EYE AND SKIN PROTECTION.
AVOID PROLONGED PERIODS OF EXPOSURE.
AVOID WEARING WHITE COLOR CLOTHING AND/OR
USING (UV) PAINTS ON SKIN.
AVOID DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES SHORTER THAN 11 feet (3.3m).
DO NOT OPERATE FIXTURE WITH DAMAGED OR MISSING EXTERNAL COVER PROTECTIVE
LENS.
DO NOT LOOK DIRECTLY INTO THE (UV) LIGHT AND/OR VIEW (UV) LIGHT DIRECTLY WITH
OPTICAL INSTRUMENTS THAT MAY CONCENTRATE THE LIGHT/RADIATION OUTPUT.
INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE
DISORDERS, OR INDIVIDUALS USING PHOTOSENSITIVE MEDICATION, MAY RECEIVE
DISCOMFORT IF EXPOSED TO THE ULTRAVIOLET (UV) LIGHT EMITTED FROM THIS FIXTURE.
ADJ Products, LLC - www.adj.com - MOD HEX100 User Manual Page 6
MOD HEX100Control Panel Layout
LCD DISPLAY
MODE BUTTON
SET UP BUTTON
POWER IN
POWER OUT
MODE
SET UP
UP
DOWN
DMX INPOWER IN
DMX IN
UP BUTTON
DOWN BUTTON
DMX IN
DMX OUT
DMX OUTDMX OUTPOWER OUT
ADJ Products, LLC - www.adj.com - MOD HEX100 User Manual Page 7
MOD HEX100DMX Set Up
REMOTE
CONTROL
INPUT
POWER
INPUTOUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUTOUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUTOUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signalerrors andavoids signal transmission problemsand interference. It is always advisableto connect a DMX terminal, (Resistance120 Ohm 1/4 W) between PIN 2 (DMX-)and PIN 3 (DMX +) of the last fixture.
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of commu-
nication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions
from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture
via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only
have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufactures to be
linked together and operate from a single controller, as long as all xtures and the controller are DMX
compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use
the shortest cable path possible. The order in which fixtures are connected in a DMX line does not
influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed
anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is
assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that
unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation): The MOD HEX100
can be controlled via DMX-512 protocol. The MOD HEX100 has 5 DMX channel
modes. The DMX address is set on the rear panel of the MOD HEX100. Your unit
and your DMX controller require a standard 3-pin XLR connector for data input and
data output (Figure 1). We recommend Accu-Cable DMX cables. If you are making
your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable
may be purchased at almost all pro lighting stores). Your cables should be made
with a male and female XLR connector on either end of the cable. Also remember
Figure 1
that DMX cable must be daisy chained and cannot be split.
Notice: Be sure to follow gures two and three when making your own cables. Do not use the ground
lug on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or allow the
shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a
short circuit and erratic behavior.
COMMON
XLR Male Socket
1 Ground
Figure 3
DMX512 OT
3-PIN XLR
2 Cold
3 Hot
1
3
2
XLR Female Socket
2 Cold
DMX +
DMX -
1 Ground
3 Hot
1
DMX512 IN
3
2
3-PIN XLR
Figure 2
XLR Pin Conguration
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
ADJ Products, LLC - www.adj.com - MOD HEX100 User Manual Page 8
MOD HEX100DMX Set Up
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUTOUTPUT
and PIN 3 (DMX +) of the last fixture.
Special Note: Line Termination.
When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is
connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted
in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable
terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
Termination reduces signal errors and
1
3
avoids signal transmission problems
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
Figure 4
5-Pin XLR DMX Connectors.
Some manufactures use 5-pin DMX-512 data cables for DATA transmis-
sion in place of 3-pin. 5-pin DMX xtures may be implemented in a 3-pin DMX line. When inserting
standard 5-pin data cables in to a 3-pin line a cable adaptor must be used, these adaptors are readily
available at most electric stores. The chart below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion
Conductor5-Pin XLR Male (In)3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
Pin 1
Pin 2
Pin 3
Pin 1
Pin 2
Pin 3
Do Not Use
Do Not Use
ADJ Products, LLC - www.adj.com - MOD HEX100 User Manual Page 9
Loading...
+ 23 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.