Door-type, Single-Rack, Chemical Sanitizer, Dump & Fill Dishmachine
Listed by UL, #E68594, NSF/ANSI 3, ASSE 1004 #933, LA Test Labs File M-780089, Mass. License P3-0111-306
1
If you have questions, call 800-922-2178 or visit our website at www.AmericanDish.com
The electrical power supplied to this machine is an imminent hazard that could result in severe
bodily injury or death if not properly installed or hooked up correctly. When working in the control
box or on electrical parts, always disconnect power and tag-out before servicing. Replace cover
to control box and other protective covers when fi nished servicing this equipment.
Copyright ADS Installation Manual Model AF-ES, Revision 3.0, 6/7/2013
2
READ Manufacturer’s Manual before Using this Product. For your safety read and observe all
cautions shown throughout these instructions. While performing installations described in this
booklet, wear approved Personal Protective Equipment, including Safety Eye-Wear.
CHEMICALS — There are potentially hazardous situations when working with industrial cleaning
chemicals for dishmachines. See chemical manufacturer’s safe practices and MSDS sheets for
handling and installing chemicals and supply containers.
#1 BEFORE YOU BEGIN — American Dish Service provides this information as a service to our
customers. Keep all instructions for future reference. ADS reserves the right to alter or update
this information at any time. Should you desire to make sure that you have the most up-to-date
information, we would direct you to the appropriate document on our web site:
www.americandish.com. Set out below are the specifi cations and requirements that you must use
and follow to properly install the type or types of equipment listed above. It is your obligation as
the customer to ensure that the machine is installed safely and properly, and when completed,
the machine is left in proper and safe working order. Electrical, Plumbing, and Chemical hookup
should be performed by a qualifi ed professional who will ensure that the equipment is installed
in accordance with all applicable Codes, Ordinances, and Safety requirements. Failure to follow
the installation instructions could void the warranty. ADS assumes no liability or control over the
installation of the equipment. Product failure due to improper installation is not covered under the
ADS Warranty.
#2 FLUSH OUT — Do not install spray arms until machine is fl ushed with water. When this
machine is turned on, it is normal for it to start and complete one cycle. First, fi ll and run a cycle.
Do this before installing the spray arms. Draining the water will fl ush installation debris from the
tank and pump; this prevents damage to spray arm bearings. To drain, pull the drain ball out of
the sump.
#3 WATER HEATERS — or boilers must provide the minimum temperature of 120°F required by
the machine listed above and which demands a minimum of 35 gallons per hour. The
recommended temperature range for optimal performance is 130-140°F. These specifi cations are
for the dishmachine only, which typically accounts for 70% of a restaurant’s hot water demand.
#4 IMPORTANT — The model of dishmachine listed in this document must be installed with space
around the outside to allow for servicing of motor and scrap accumulator as well as a 4” space
behind the machine from the wall.
#5 INSPECT FOR DAMAGE — If you receive a damaged dishmachine, do not sign “Clear” but write
“Damaged” on the documents.
#6 LOOSE ELECTRICAL CONNECTIONS — Damage to equipment can occur if the following
precautions are not observed. Before connecting power to the machine, check all electrical
terminals in the control box. Screws can loosen in transit. Loose connections on high amp load
terminals such as the pump motor will cause wire burning and component damage during
operation and will not be covered under ADS warranty.
Copyright ADS Installation Manual Model AF-ES, Revision 3.0, 6/7/2013
#7 “CLEAN CIRCUIT” means the electrical circuit breaker for the dishmachine supplies no other
outlets, machines, or lights. GFCI outlets are not recommended for commercial dishmachines;
ADS recommends that a single-rack machine be installed with the wire connection (hard-wired)
directly from the circuit breaker. If a plug and socket are used to provide electrical power to a
dishmachine in a commercial kitchen, then according to electrical code it must be a GFCI, but not
all GFCIs are the same. They must be rated for the draw of the circuit.
Reference NEC Article 210.8 GFCI Protection (B) Other Than Dwelling Units (2) Commercial and
Institutional Kitchens. All 15 and 20A, 125V receptacles installed in kitchens, even those that do not
supply the countertop surface, must be GFCI protected.
#8 This equipment is considered an item of heavy use. It is not rated for outdoor use.
ELECTRICAL SECTION
The electrical power supplied to this machine is an imminent hazard that could result in
severe bodily injury or death if not properly installed or hooked up correctly.
Electrical—AF-ES, AFC-ES, (120 volt, 20 amp)
3
Showing control tray installed in normal positionShowing control tray lifted up to service pumps
The power supply for 120 volts, 20amps, shall consist of two #10-12-gauge wires and one suitable green
ground wire. The 20 amp breaker or 20 amp fuse must be on a clean circuit for only the machine. ADS
has provided a junction box with a 7/8” hole for the 1/2” conduit that will bring the building’s electrical
power to the machine. The junction box is attached to the back of the control box.
Remove the junction box cover, attach the conduit and connect a black 120 volt supply wire to the black
wire in the junction box. Connect a white neutral supply wire to the white wire in the junction box. When
powered up, test the neutral wire to a ground source with a volt meter, it should read 0 to 6 volts. Test the
black wire to a ground source, it should read 110-120 volts. Attach a building ground wire to the green
ground screw located in the junction box and tighten all wires. Replace the junction box cover and control
box lid. Label the 20 amp circuit breaker, “DISHMACHINE.”
Copyright ADS Installation Manual Model AF-ES, Revision 3.0, 6/7/2013
Showing control box, chemical pumps, prime switchesShowing power connection box for 120v wiring
4
Ground screw in junction boxLine connection spades for L1, Neu (arrow 1 & 2)
THIS MACHINE DOES NOT USE A BOOSTER OR TANK SUSTAINER HEATER.
IT IS RECOMMENDED THAT THIS EQUIPMENT BE INSTALLED USING A NEW CIRCUIT BREAKER.
PLUMBING SECTION
#1 TANKLESS water heaters can be problematic for commercial dishmachines. The ADS model
AF-ES dishmachine requires the full cycle amount of water (.95 gallon) supplied within 7 seconds.
It has been the experience of ADS that tankless supply systems require multiple units plumbed in
sequence with a recirculation loop to achieve proper pressure and temperature.
Check with the tankless water heater manufacturer, they may recommend a storage tank to
guarantee proper fl ow and line pressure to the machine. Failure to provide adequate water
quantity, pressure and temperature to the machine will cause the machine to function improperly
and is not the responsibility of ADS. Improperly installing ADS equipment in this manner could
void the warranty. All costs associated with providing an adequate water supply to the machine is
the sole responsibility of the user.
Copyright ADS Installation Manual Model AF-ES, Revision 3.0, 6/7/2013
#2 HOODS—Follow all local plumbing and mechanical codes. IMC 2012, section 507.2.2 requires
Type II hoods for all commercial dishwashers except where the heat and moisture loads are
incorporated into the building’s HVAC systems or dishwashing equipment designed with
separate heat and moisture removal systems. The door-type, chemical sanitizing dishwasher in
this manual is rated at 6753 Btu/h by UL Project #12CA71037, according to ASTM F1704-12 and
ASTM F2474-09. This sensible and latent gain would typically require a half ton of AC. ADS DOES
NOT SPECIFY BUILDING HVAC VALUES
#3 DRAIN SIZE—Gravity drain lines are 2” pipe size. Do not use reducing adapters for drain lines,
always use same diameter pipe or larger. Close pump petcocks if equipped.
5
Showing ½” female pipe inlet, ball valve, y-line fi lter,
water solenoid, ASSE approved air gap (backfl ow preventer)
Typical name plate information
Hot Water Connection
WATER HEATER — Flush the building’s water lines before connecting to the dishmachine. Prior to
connecting plumbing, level the machine by adjusting the feet at the bottom of each leg up or down.
Water heaters or boilers must provide the minimum temperature of 120°F for this model of machine,
which demands a minimum of 35 GPH for AF-ES series. Temperatures above 150°F exceed the
operational design limits for this model. This model cannot be converted to high temp sanitizing by
adding a booster.
INLET FLEX HOSE — Domestic style 1/2” fl exible braded hose should not be used to connect the
dishmachine to plumbing. The ID of the plastic liner for this type hose restricts fl ow. Connect 1/2" male
pipe thread (1/2” is the minimum allowable pipe size) of the hot water supply line to the 1/2" female pipe
thread on the dishmachine’s water inlet manifold.
SINK FAUCET — If the hot water line is also supplying the faucet of a pre-rinse sink, install check valves
on both cold and hot water inlets to the faucet— to avoid cooling the water by cross-connection in the
mixing head of the faucet. The hot water inlet manifold is located behind the AF-ES control box. The
supply water must have a minimum of 120°F, but 130-140°F is recommended for best results.