Amana RCE42C2A, RCE24C2A, RCE30C2A, RCE36C2A, RCE48C2A Speci? Cation Sheet

...
Page 1
Specifi cation Sheet
14 SEER
Cooling Capacity:
24,000 - 60,000 BTUH
LIMITED WARRANTY
• Lifetime—Compressor
• 10-Year Limited—Parts
U
R
L
C
U
R
L
RCE Prestige™
Split System Air Conditioner
The Amana® brand RCE Prestige™ Air Conditioners offer economy, dependable cooling comfort, high-effi ciency performance, application fl exibility and installation and service ease. Cost-effective engineering, low operating costs, reliable components and quality manufacturing make RCE units perfect for the value-minded homeowner or cost-conscious builder.
High-effi ciency Copeland Scroll Compressor with Factory- installed Sound Blanket. Compressor is hermetically sealed and
features safeguards to protect it from excessive temperatures, pressure and abnormal electrical currents. In addition, energy-saving design reduces internal resistance and friction and increases operating effi ciency. The entire compressor is mounted on rubber cushions to help absorb vibrations. Economy and Performance. Simplicity of design and construction make this unit economical to own as well as operate. The balance of economy and effi ciency makes RCE units ideal for replacement or new construction. The RCE line delivers SEERs of up to 15 when paired with high-effi ciency blower coils, which can help reduce your cooling costs. Refrigerant line connections and service valves are easy to reach. Embossments in the bottom allow drainage and air fl ow under the unit to reduce corrosion. Heavy vinyl-coated grilles protect the fan, motor and coil. Controls and service valves can be serviced without interrupting unit operation. Copper and Aluminum Coils. The RCE condenser features enhanced fi ns. Our condenser and evaporator coils are made from copper tubing and aluminum fi ns. Tubing life is extended and fewer leaks experienced because we use only refrigeration­grade copper tubing. Optional “A” Coils are shipped with leak-proof plastic drain pans attached. All coils have sweat connections and are fully leak tested before leaving the factory. Pressure Controls and Time Delay provide additional protection to the compressor upon a loss of charge to the system. The time delay prevents short cycling. A 3-minute delay occurs when the power supply or the indoor thermostat’s signal is interrupted. Field-Piped Refrigerant System. Sweat style service valves are used for a more positive connection. Installers can size the tubing to fi t the job with a neat application and no waste for better control. Unit is shipped charged with refrigerant for a 15’ liquid line and matching indoor coil. Service Valves and Gauge Ports are angled at 30° with enough clearance to allow quick and easy servicing of the unit. Service panel swings open at the corner for effective service from two directions. Inside, a pre-wired control panel speeds installation. Minimal quantity of numbered and color-coded wires to assure fast fi eld wiring. Compressor and tubing access from the side and top give plenty of internal room for installation and removal of parts. Factory-installed Liquid Line Filter Drier. Standard protection adds to reliability by helping to keep refrigerant clean and dry. Clean and dry refrigerant ensures longer life for the compressor and expansion devices. Quiet Condenser Fan with Vertical Air Discharge. Quiet, effi cient fan and motor reduce operating sounds and large blades move high volumes of air with lower power requirement. Draw through air fl ow directs operating sound and hot air away from neighbors, shrubs and buildings. Adds to installation versatility. Cabinets. Painted sheet metal cabinet maintains its attractive nish for many years. Cabinet and screws resist rust and fading due to UV rays. When properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds.
www.amana-hac.com
Page 2
Specifi cation Sheet
Nomenclature
R E 24 C 2
Product Type
R: Remote Condensing
Unit or Heat Pump
System Type
C: Cooling
Product Family
C
E: 14 SEER
Revision
(C Indicates Two-Tone
Color Scheme)
Voltage
2: 208/230-60-1
Marketing Designator
C: Current Series
Nominal
Capacity
24: 24,000 Btuh 30: 30,000 Btuh 36: 36,000 Btuh
42: 42,000 Btuh 48: 48,000 Btuh
60: 60,000 Btuh
2
www.amana-hac.com
Page 3
Specifi cation Sheet
Specifi cations for C2A Models
RCE24C2A RCE30C2A RCE36C2A RCE42C2A RCE48C2A RCE60C2A
Cooling Capacities
Nominal Cooling Capacity (Btuh) 24,000 30,000 36,000 42,000 48,000 60,000
Compressor
R.L. AMPS 10.8 12.2 14.7 16.5 18.3 25.0
L.R. AMPS 54.0 67.0 83.0 95.0 109.0 169.0
Condenser Fan Motor
Horsepower 1/12 1/4
R.L. AMPS 0.6 1.70
L.R. AMPS 1.0 3.30
Sound Levels (Db) 7.2 7.2 7.4 7.6 7.6 7.8
Refrigerant Lines
Liquid Line (“O.D.) 3/8
Suction Line (“O.D.) 3/4 7/8 1-1/8
Refrigerant Charge 155.0 oz. 160.0 oz. 225.0 oz. 225.0 oz. 235.0 oz. 245.0 oz.
Design Subcooling Cooling Mode 11° ± 3° 11° ± 3° 11° ± 3° 11° ± 3° 11° ± 3° 11° ± 3°
Electrical
Power Supply 208/230-60-1
Minimum Circuit Ampacity 14.22 16.0 20.5 22.7 25.0 33.4
Maximum Overcurrent Device 20 25 35 35 40 55
Electrical Conduit Size
Power Supply 1/2” or 3/4”
Low Voltage 1/2”
Approximate Shipping Weights (pounds)
Weight 208 209 270 272 274 314
Dimensions
Square Base Height
RCE24C2A 29½” 29”
RCE30C2A 29½” 29”
RCE36C2A 35 33”
RCE42C2A 35 33”
RCE48C2A 35 33”
RCE60C2A 35 37”
www.amana-hac.com
3
Page 4
Specifi cation Sheet
Specifi cations for C2C Models
RCE24C2C RCE30C2C RCE36C2C RCE42C2C RCE48C2C RCE60C2C
Cooling Capacities
Nominal Cooling Capacity (Btuh) 24,000 30,000 36,000 42,000 48,000 60,000
Compressor
R.L. AMPS 10.90 12.18 13.46 16.54 17.95 19.87
L.R. AMPS 54.0 63.0 73.0 95.0 104.0 137.0
Condenser Fan Motor
Horsepower 1/12 1/6
R.L. AMPS 0.6 1.10
L.R. AMPS 1.0 1.90
Sound Levels (Db) 7.2 7.2 7.4 7.6 7.6 7.8
Refrigerant Lines
Liquid Line (“O.D.) 3/8
Suction Line (“O.D.) 3/4 7/8 1-1/8
Refrigerant Charge 120.0 oz. 125.0 oz. 160.0 oz. 175.0 oz. 175.0 oz. 235.0 oz.
Design Subcooling Cooling Mode 11° ± 3° 11° ± 3° 11° ± 3° 11° ± 3° 11° ± 3° 11° ± 3°
Electrical
Power Supply 208/230-60-1
Minimum Circuit Ampacity 14.22 15.82 17.93 21.77 23.54 26.54
Maximum Overcurrent Device 25 25 30 35 40 45
Electrical Conduit Size
Power Supply 1/2” or 3/4”
Low Voltage 1/2”
Approximate Shipping Weights (pounds)
Weight 175 175 230 230 235 260
Dimensions
Square Base Height
RCE24C2C 29½” 37”
RCE30C2C 29½” 37”
RCE36C2C 35 37”
RCE42C2C 35 37”
RCE48C2C 35 37”
RCE60C2C 35 37”
4
www.amana-hac.com
Page 5
Cooling Specifi cations for C2A Models
Specifi cation Sheet
RCE24C2A with CHA24T*C Conditions: 80° ID DB, 67° ID WB @ 800 CFM
Outdoor
Ambient °F
75° 25,600 171,509 8,450 1,550 80° 25,300 17,200 8,100 1,600 85° 25,000 17,250 7,750 1,660 90° 24,700 17,290 7,410 1,710
95° 24,400 17,325 7,075 1,760
100° 23,800 17,250 6,550 1,800 105° 23,200 17,170 6,030 1,840 110° 22,350 16,540 5,810 1,875 115° 21,500 15,910 5,590 1,910
TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
95° 23,900 18,400 5,500 1,600
RCE30C2A with CHA30T*C Conditions: 80° ID DB, 67° ID WB @ 1,000 CFM
Outdoor
Ambient °F
75° 30,200 20,840 9,360 1,850
80° 29,850 20,890 8,960 1,910
85° 29,500 20,945 8,555 1,980
90° 29,150 20,985 8,165 2,040
95° 28,400 21,025 7,775 2,100
100° 28,100 20,925 7,175 2,150 105° 27,400 20,825 6,575 2,200
110° 26,350 20,020 6,330 2,245
115° 25,300 19,230 6,070 2,290
TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
95° 27,500 22,550 4,950 2,100
Total
Btuh
Total
Btuh
Sensible
Btuh
Sensible
Btuh
Latent
Btuh
Latent
Btuh
Total
Outdoor
Watts
Total
Outdoor
Watts
RCE42C2A with CHA42T*C Conditions: 80° ID DB, 67° ID WB @ 1,400 CFM
Outdoor
Ambient °F
75° 42,000 29,400 12,600 2,520 80° 41,500 29,460 12,040 2,610 85° 41,000 29,520 11,480 2,700 90° 40,500 29,560 10,940 2,775
95° 40,000 29,600 10,400 2,850
100° 39,000 29,430 9,570 2,915 105° 38,000 29,260 8,740 2,980 110° 36,600 29,180 8,420 3,040 115° 35,200 27,100 8,100 3,100
TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
95° 37,100 29,300 7,800 2,730
RCE48C2A with CHA54T*C Conditions: 80° ID DB, 67° ID WB @ 1,600 CFM
Outdoor
Ambient °F
75° 49,400 34,580 14,820 2,930
80° 48,800 34,640 14,160 3,035
85° 48,200 34,700 13,500 3,140 90° 47,600 34,740 12,860 3,235
95° 47,000 34,780 12,220 3,330
100° 45,850 34,590 11,260 3,400
105° 44,700 34,400 10,300 3,480
110° 43,050 33,140 9,910 3,620 115° 41,400 31,880 9,520 3,620
TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
95° 43,600 34,400 9,200 3,180
Total
Btuh
Total
Btuh
Sensible
Btuh
Sensible
Btuh
Latent
Btuh
Latent
Btuh
Total
Outdoor
Watts
Total
Outdoor
Watts
RCE36C2A with CHA36T*C Conditions: 80° ID DB, 67° ID WB @ 1,200 CFM
Outdoor
Ambient °F
75° 37,800 26,080 11,720 2,230 80° 38,350 26,140 11,210 2,305 85° 36,900 26,200 1,070 2,380 90° 36,450 26,240 10,210 2,450
95° 36,000 26,280 9,720 2,520
100° 35,100 26,135 8,965 2,575 105° 34,200 25,990 8,210 2,630 110° 32,950 25,040 7,910 2,680 115° 31,700 24,090 7,610 2,730
TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
95° 33,400 26,050 7,350 2,410
Total
Btuh
Sensible
Btuh
Latent
Btuh
RCE60C2A with CHA60T*C Conditions: 80° ID DB, 67° ID WB @ 1,800 CFM
Total
Outdoor
Watts
Outdoor
Ambient °F
75° 62,000 42,780 19,220 3,830 80° 61,250 42,865 18,385 3,970 85° 60,500 42,950 17,550 4,110 90° 59,750 43,010 16,740 4,230
95° 59,000 43,070 15,930 4,360
100° 57,550 42,850 14,700 4,465 105° 56,100 42,630 13,470 4,570 110° 54,000 41,035 12,965 4,660 115° 51,900 39,440 12,460 4,750
TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
95° 54,700 42,660 12,040 4,160
www.amana-hac.com
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Outdoor
Watts
5
Page 6
Specifi cation Sheet
Cooling Specifi cations for C2C Models
RCE24C2C / CA*025*2A + TVX Conditions: 80° ID DB, 67° ID WB @ 800 CFM
Outdoor
Temp. ° F.
75° 24,990 17,688 7,302 1,843
80° 24,693 17,989 6,704 1,898
85° 24,395 18,277 6,118 1,953
90° 24,098 18,054 6,044 2,002
95° 23,800 17,831 5,969 2,050
100° 23,205 17,715 5,490 2,091
105° 22,610 17,581 5,029 2,950
110° 21,777 17,005 4,772 2,168
115° 20,944 16,422 4,522 2,203
95 22,054 4,401 17,653 1,973
RCE30C2C / CAX*037*2A + TXV Conditions: 80° ID DB, 67° ID WB @ 1,000 CFM
Outdoor
Temp. ° F.
75° 29,610 20,421 9,189 2,060
80° 29,258 20,435 8,823 2,121
85° 28,905 20,442 8,463 2,182
90° 28,553 20,518 8,035 2,236
95° 28,200 20,586 7,614 2,290
100° 27,495 20,452 7,043 2,336
105° 26,790 20,298 6,492 3,600
110° 25,803 19,632 6,171 2,421
115° 24,816 18,960 5,856 2,461
95 26,131 5,751 20,380 2,204
Total Btuh
TVA Conditions @ 95° OD DB, 75° ID DB, 63 ID WB
Total
Btuh
TVA Conditions @ 95° OD DB, 75° ID DB, 63 ID WB
Sensible
Btuh
Sensible
Btuh
Latent
Btuh
Latent
Btuh
Total
Watts
Total
Watts
RCE42C2C/CA*X049*2A + TXV Conditions 80° ID DB, 67° ID WB @ 1,000 CFM
Outdoor
Temp. ° F.
75° 43,050 34,980 8,070 3,104
80° 42,538 31,705 10,833 3,194
85° 42,025 28,499 13,526 3,284
90° 41,513 28,605 12,907 3,363
95° 41,000 28,700 12,300 3,442
100° 39,975 28,513 11,462 3,509
105° 38,950 28,298 10,652 5,040
110° 37,515 27,370 10,145 3,635
115° 36,080 26,433 9,647 3,693
95 37,992 9,579 28,413 3,316
RCE48C2C / CA*X061*2A + TXV Conditions: 80° ID DB, 67° ID WB @ 1500 CFM
Outdoor
Temp. ° F.
75° 49,350 33,569 15,781 3,441
80° 48,763 33,591 15,171 3,601
85° 48,175 33,603 14,572 3,760
90° 47,588 33,728 13,859 3,855
95° 47,000 33,840 13,160 3,950
100° 45,825 33,619 12,206 4,031
105° 44,650 33,366 11,284 6,360
110° 43,005 32,272 10,733 4,181
115° 41,360 31,167 10,193 4,250
95 43,552 10,050 33,502 3,800
Total Btuh
TVA Conditions @ 95° OD DB, 75° ID DB, 63 ID WB
Total Btuh
TVA Conditions @ 95° OD DB, 75° ID DB, 63 ID WB
Sensible
Btuh
Sensible
Btuh
Latent
Btuh
Latent
Btuh
Total
Watts
Total
Watts
RCE36C2C / CAX*042*2A + TXV Conditions: 80° ID DB, 67° ID WB @ 1,150 CFM
Outdoor
Temp. ° F.
75° 36,540 24,510 12,030 2,648
80° 36,105 24,526 11,579 2,726
85° 35,670 24,535 11,135 2,803
90° 35,235 24,626 10,609 2,872
95° 34,800 24,708 10,092 2,940
100° 33,930 24,547 9,383 2,998
105° 33,060 24,362 8,698 3,600
110° 31,842 23,563 8,279 3,106
115° 30,624 22,756 7,868 3,157
95 32,247 7,786 24,461 2,831
Total Btuh
TVA Conditions @ 95° OD DB, 75° ID DB, 63 ID WB
Sensible
Btuh
Latent
Btuh
Total
Watts
RCE60C2C/ CAX*061*2A + TXV Conditions: 80° ID DB, 67° ID WB @ 1750 CFM
Outdoor
Temp. ° F.
75° 59,850 40,712 19,138 4,347
80° 59,138 40,738 18,399 4,553
85° 58,425 40,753 17,672 4,760
90° 57,713 40,904 16,808 4,882
95° 57,000 41,040 15,960 5,005
100° 55,575 40,772 14,803 5,109
105° 54,150 40,465 13,685 2,607
110° 52,155 39,138 13,017 5,303
115° 50,160 37,798 12,362 5,393
95 52,818 12,189 40,630 48,10
Total Btuh
TVA Conditions @ 95° OD DB, 75° ID DB, 63 ID WB
Sensible
Btuh
Latent
Btuh
Total
Watts
6
www.amana-hac.com
Page 7
Performance Ratings
Specifi cation Sheet
Model Evaporator Model Total BTUH Sensible BTUH SEER EER ARI Ref. # Decibel
RCE24C2*
RCE30C2*
ARPT032-00A-1 CHH24TCD+BDK CHH30TCD+BDK
AEPT030-00A-1
ARUF032-00A-1
ARPF036-00B-1
CA*X025*2*+A*V90453B**
CA*X025*2*+MBR800****
CA*X025*2*+BDK
CA*X030*2*+A*V90453B**
CA*X030*2*+A*V90704C**
CA*X030*2*+MBR800****
CA*X030*2*+BDK
CA*X037*2*+A*V90453B**
CA*X037*2*+A*V90704C**
CA*X037*2*+MBR800****
CA*X037*2*+MBE1200****
CA*X037*2*+BDK
CH*X024*2*+A*V90704C**
CH*X024*2*+MBR800****
CH*X024*2*+BDK
CH*X030*2*+A*V90453B**
CH*X030*2*+MBR800****
CH*X030*2*+BDK
CH*X037*2*+A*V90453B**
CH*X037*2*+A*V90704C**
CH*X037*2*+MBR800****
CH*X037*2*+MBE1200****
CH*X037*2*+BDK
ARPT042-00A-1
CCH36FCD+TXV+BDK
CHH36TCD+BDK CHH30TCD+BDK
AEPT030-00A-1
ARUF042-00A-1
ARPF036-00B-1
CA*X030*2*+A*V90704C**
CA*X037*2*+A*V90453B** CA*X037*2*+A*V90704C** CA*X037*2*+A*V90905D**
CA*X037*2*+MBR1200****
CA*X037*2*MBE1200****
CA*X037*2*+BDK CA*X042*2*+A*V90453B** CA*X042*2*+MBR1200**** CA*X042*2*+MBE1200****
CA*X042*2*+BDK
CA*X049*2*+BDK CH*X030*2*+A*V90453B** CH*X037*2*+A*V90453B** CH*X037*2*+MBE1200**** CH*X042*2*+A*V90453B**
CH*X042*2*+A*V90704C**
CH*X042*2*+BDK
23,000 23,200 24,200 23,600 23,000 23,000 24,000 24,400 23,800 24,000 24,400 23,800 23,200 24,600 24,800 24,800 24,800 24,200 24,600 24,600 23,400 24,000 24,200 24,000 24,000 24,800 23,800 24,200 23,600
27,000 27,600 27,600 27,600 28,800 27,000 27,000 27,200 28,000 27,200 28,600 28,400 28,800 28,800 28,000 28,600 29,000 28,800 26,600 27,000 27,000 27,400 28,000 28,000 27,400
16,300 16,500 17,200 16,800 16,300 16,300 17,000 17,300 16,900 17,000 17,300 16,900 16,500 17,500 17,600 17,600 17,600 17,200 17,500 17,500 16,600 17,000 17,200 17,000 17,000 17,600 16,900 17,200 16,800
20,000 20,400 20,400 20,400 21,300 20,000 20,000 20,100 20,700 20,100 21,200 21,000 21,300 21,300 20,700 21,200 21,500 21,300 19,700 20,000 20,000 20,300 20,700 20,700 20,300
14.0
14.0
14.0
15.0
14.0
14.0
15.0
15.0
14.0
15.0
15.0
15.0
14.0
16.0
16.0
15.0
16.0
14.0
15.0
14.0
14.0
15.0
15.0
14.0
15.0
15.0
15.0
15.0
14.0
14.0
14.0
14.0
13.0
15.0
14.0
13.0
14.0
15.0
15.0
15.0
14.0
15.0
14.0
15.0
14.0
15.0
14.0
14.0
14.0
14.0
14.0
15.0
15.0
14.0
12.7
12.3
12.3
14.0
12.7
12.7
12.8
12.8
12.3
12.8
12.8
12.8
12.3
13.5
13.5
12.8
13.5
12.3
12.8
12.3
12.3
12.8
12.8
12.3
12.8
12.8
12.8
12.8
12.3
12.7
12.3
12.3
11.7
14.0
12.7
11.7
12.3
12.8
12.8
12.8
12.3
12.8
12.3
12.8
12.3
12.8
12.3
12.3
12.3
12.3
12.3
12.8
12.8
12.3
410056 411353 411402 462893 468210 468755 504540 504541 504542 504543 504544 504545 504546 504547 504548 504549 504550 504551 504552 504553 504554 504555 504556 504557 504558 504559 504560 504561 504562
410048 411383 411391 462467 462894 468204 469096 504563 504564 504565 504566 504567 504568 504569 504570 504571 504572 504573 504574 504575 504576 504577 504578 504579 504580
71
71
www.amana-hac.com
7
Page 8
Specifi cation Sheet
Performance Ratings (cont.)
Model Evaporator Model Total BTUH Sensible BTUH SEER EER ARI Ref. # Decibel
RCE36C2*
RCE42C2*
ARPT049-00A-1
CHH36TCD+BDK CCH48FCD+TXV+BDK CCH36FCD+TXV+BDK
AEPT036-00A-1 ARUF042-00A-1
ARPF048-00B-1 CA*X037*2*+A*V90905D** CA*X037*2*+A*V91155D**
CA*X037*2*+MBR1200**** CA*X037*2*+MBE1200****
CA*X037*2*+BDK CA*X042*2*+A*V90453B** CA*X042*2*+MBR1200**** CA*X042*2*+MBE1200**** CA*X042*2*+MBE1600****
CA*X042*2*+BDK
CA*X049*2*+A*V90704C** CA*X049*2*+A*V90905D** CA*X049*2*+A*V91155D**
CA*X049*2*+MBR1600**** CA*X049*2*+MBE1600**** CA*X049*2*+MBE2000****
CA*X049*2*+BDK
CA*X049*2*+BDK CH*X030*2*+A*V90453B** CH*X037*2*+A*V90453B** CH*X037*2*+MBR1200****
CH*X037*2*+BDK CH*X042*2*+A*V90453B**
CH*X042*2*+A*V90704C**
CH*X042*2*+MBR1600**** CH*X042*2*+MBE1600****
CH*X042*2*+BDK
CH*X048*2*+A*V90905D** CH*X048*2*+A*V91155D**
CH*X048*2*+MBE2000****
CH*X048*2*+BDK
ARPT049-00A-1
CHH60TCD+BDK
CCH60FCD+TXV+BDK
AEPT060-00A-1 ARUF049-00A-1 ARPF048-00B-1
CA*X042*2*+A*V90453B**
CA*X042*2*+A*V90704C**
CA*X042*2*+MBR1200**** CA*X042*2*+MBE1200****
CA*X042*2*+BDK
CA*X049*2*+A*V90704C** CA*X049*2*+A*V90905D** CA*X049*2*+A*V91155D**
CA*X049*2*+MBR1600**** CA*X049*2*+MBE1600**** CA*X049*2*+MBR2000****
CA*X049*2*+BDK
CA*X060*2*+A*V90905D** CA*X060*2*+A*V91155D**
CA*X060*2*+MBR2000**** CA*X060*2*+MBE2000****
CA*X060*2*+BDK
CH*X042*2*+A*V90704C**
CH*X042*2*+BDK
CH*X048*2*+A*V90704C** CH*X048*2*+A*V90905D** CH*X048*2*+A*V91155D**
CH*X048*2*+MBR1600**** CH*X048*2*+MBE1600**** CH*X048*2*+MBR2000**** CH*X048*2*+MBE2000****
CH*X048*2*+BDK
35,000 34,800 36,000 34,800 34,800 35,000 35,000 35,000 35,200 35,200 35,200 34,600 35,200 35,200 35,400 36,000 34,800 35,600 35,800 35,800 35,600 36,200 36,200 35,800 35,000 33,200 33,200 34,000 34,600 34,200 34,800 35,000 35,200 35,000 35,000 35,200 36,000 35,000
40,000 41,500 41,500 38,500 40,000 40,000 39,000 39,000 39,500 40,000 39,000 40,000 40,000 40,500 40,500 40,500 39,500 38,500 40,500 40,500 40,000 40,500 40,500 38,500 39,000 38,500 39,500 40,000 39,000 39,500 38,500 40,000 39,000
25,600 25,400 26,300 25,400 25,400 25,600 25,600 25,600 25,700 25,700 25,700 25,300 25,700 25,700 25,700 26,300 25,400 25,000 26,100 26,100 26,000 26,400 26,400 26,100 25,600 24,200 24,800 24,800 25,300 25,000 25,400 25,700 25,700 25,700 25,700 25,700 26,300 25,600
29,600 30,700 30,700 28,500 29,600 29,600 28,900 28,900 29,200 29,600 28,900 29,600 29,600 30,000 30,000 30,000 29,300 28,500 30,000 30,000 29,600 30,000 30,000 28,500 28,900 28,500 29,200 29,600 28,900 29,200 28,500 29,600 28,900
14.0
14.0
14.0
14.0
15.0
14.0
14.0
15.0
15.0
14.0
15.0
14.0
15.0
14.0
15.0
15.0
14.0
15.0
16.0
16.0
14.0
15.0
16.0
14.0
14.0
14.0
14.0
14.0
14.0
15.0
15.0
14.0
15.0
14.0
15.0
15.0
16.0
14.0
14.0
14.0
14.0
15.0
14.0
14.0
14.0
15.0
14.0
14.0
14.0
15.0
15.0
15.0
14.0
15.0
14.0
14.0
16.0
16.0
14.0
16.0
14.0
14.0
14.0
14.0
15.0
15.0
14.0
15.0
14.0
15.0
14.0
12.7
12.3
12.3
12.3
14.0
12.7
12.7
12.8
12.8
12.3
12.8
12.3
12.8
12.3
12.8
12.8
12.3
12.8
13.5
13.5
12.3
12.8
13.5
12.3
12.3
12.3
12.3
12.3
12.3
12.8
12.8
12.3
12.8
12.3
12.8
12.8
13.5
12.3
12.6
12.3
12.3
14.0
12.6
12.6
12.3
12.8
12.3
12.3
12.3
12.8
12.8
12.8
12.3
12.8
12.3
12.3
13.5
13.5
12.3
13.5
12.3
12.3
12.3
12.3
12.8
12.8
12.3
12.8
12.3
12.8
12.3
410045 411434 411465 411467 462895 468211 469094 504581 504582 504583 504584 504585 504586 504587 504588 504589 504590 504591 504592 504593 504594 504595 504596 504597 504598 504599 504600 504601 504602 504603 504604 504605 504606 504607 504608 504609 504610 504611
410057 411533 411545 462896 468208 468788 504612 504613 504614 504615 504616 504617 504618 504619 504620 504621 504622 504623 504624 504625 504626 504627 504628 504629 504630 504631 504632 504633 504634 504635 504636 504637 504638
73
73
8
www.amana-hac.com
Page 9
Performance Ratings (cont.)
Specifi cation Sheet
Model Evaporator Model Total BTUH Sensible BTUH SEER EER ARI Ref. # Decibel
RCE48C2*
RCE60C2*
ARPT049-00A-1
CHH60TCD+BDK CCH60FCD+TXV+BDK CCF61FCC+TXV+BDK
CHH48TCD+BDK
AEPT060-00A-1 ARUF048-00A-1
ARPF060-00B-1 CA*X049*2*+A*V90905D** CA*X049*2*+A*V91155D**
CA*X049*2*+MBE1600****
CA*X049*2*+BDK CA*X060*2*+A*V90905D** CA*X060*2*+A*V91155D**
CA*X060*2*+MBR2000**** CA*X060*2*+MBE2000**** CA*X061*2*+MBR2000**** CA*X061*2*+MBE2000****
CA*X061*2*+BDK
CH*X048*2*+A*V90905D** CH*X048*2*+A*V91155D** CH*X048*2*+MBE1600**** CH*X048*2*+MBR2000**** CH*X048*2*+MBE2000****
CH*X048*2*+BDK
CH*X060*2*+MBR2000**** CH*X060*2*+MBE2000****
CH*X060*2*+BDK
ARPT061-00A-1
CHH60TCD+BDK
AEPT060-00A-1 ARUF061-00A-1 ARPF060-00B-1
CA*X060*2*+A*V91155D**
CA*X060*2*+MBE2000**** CA*X061*2*+A*V90905D** CA*X061*2*+A*V91155D**
CA*X061*2*+MBR2000****
CA*X061*2*+BDK
CH*X048*2*+MBE2000****
CH*X048*2*+BDK CH*X060*2*+A*V91155D** CH*X060*2*+MBE2000****
CH*X060*2*+BDK
45,000 47,000 47,000 46,500 46,000 46,500 45,000 45,000 44,000 44,000 46,000 45,000 46,000 46,000 45,500 46,000 46,500 47,500 46,500 45,000 45,000 44,500 45,500 46,000 45,000 46,500 47,500 46,500
57,000 57,000 56,000 57,000 57,000 56,500 56,000 57,000 57,500 59,000 57,000 56,000 55,500 57,000 58,000 57,000
33,300 34,800 34,800 34,400 34,000 34,400 33,300 33,300 32,600 32,600 34,000 33,300 34,000 34,000 33,700 34,000 34,500 35,200 34,400 33,300 33,300 32,900 33,700 34,000 33,300 34,400 35,200 34,400
41,600 41,600 40,900 41,600 41,600 41,200 40,900 41,600 42,000 43,100 41,600 40,900 40,500 41,600 42,300 41,600
14.0
14.0
14.0
14.0
13.0
15.0
14.0
14.0
14.0
14.0
14.0
13.0
14.0
14.0
14.0
14.0
14.0
15.0
14.0
14.0
14.0
14.0
14.0
15.0
14.0
14.0
15.0
14.0
14.0
14.0
14.5
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
13.0
14.0
14.0
14.0
12.0
12.3
12.3
12.3
12.1
14.0
12.0
12.0
12.3
12.3
12.3
11.9
12.3
12.3
12.3
12.3
12.3
12.8
12.3
12.3
12.3
12.3
12.3
12.8
12.3
12.3
12.8
12.3
12.7
12.3
13.5
12.7
12.7
12.3
12.3
12.3
12.3
12.3
12.3
12.3
11.6
12.3
12.3
12.3
410049 411582 411585 411586 435969 462898 468216 469098 504639 504640 504641 504642 504643 504644 504645 504646 504647 504648 504649 504650 504651 504652 504653 504654 504655 504656 504657 504658
410055 411672 462897 468213 468789 504659 504660 504661 504662 504663 504664 504665 504666 504667 504668 504669
74
76
www.amana-hac.com
9
Page 10
Specifi cation Sheet
Accessories
Model Description RCE24C2* RCE30C2* RCE36C2* RCE42C2* RCE48C2* RCE60C2*
ASAS Electronic Air Cleaner X X X X X X
FSK01A** Freeze Thermostat Kit X X X X X X
AMU Media Air Cleaner X X X X X X
PCK01A Pressure Control Kit X X X X X X
ASC01A Anti-short Cycle Kit X X X X X X
LSK01A Liquid Line Solenoid Kit X X X X X X
** Factory-installed
10
www.amana-hac.com
Page 11
Specifi cation Sheet
Thermostats
Model M038101 1213402 1213401 1213408
Manual/Auto Manual Manual Manual Manual or Auto
Programmable No No Yes Yes
Cool 1 1 1 1
Heat 1 1 1 1
Emergency Electric Heat No No No Yes
Shape Rect. / Vertical Rectangular Rectangular Rectangular
Battery Powered No Yes Yes No
24V Powered w/Battery Back-up No No No Yes
For Use With Gas Heat, Electric Heat, Electric Cool
Color Beige White White White
www.amana-hac.com
11
Page 12
Specifi cation Sheet
Amana® is a trademark of Maytag Corporation and used under license to Goodman Company, L.P. All rights reserved. Our continuing commitment to quality products may mean a change in specifi cations without notice. Copyright © 2004 Goodman Company, L.P. · Houston, Texas · Printed in U.S.A.
12
www.amana-hac.com
Date: 8/04
Supercedes 2/04
Form: PDB-RCE
Loading...