RCC36A2B |
|
Specification Sheet |
|
|
Condensing Unit |
|
Due to policy of continual product improvement, the right is |
|
|
|
reserved to change specifications and design without notice. |
|
|
|
|
|
|
|
|
|
|
|
|
Specifications
Cooling Capacity, BTUH (Nominal) |
36,000 |
Compressor |
|
R.L. Amps |
14.40 |
L.R. Amps |
82.00 |
Condenser Fan Motor |
|
Horsepower |
1/12 |
R.L. Amps |
0.60 |
L.R. Amps |
1.20 |
Liquid Line, Inches O.D. |
3/8 |
Suction Line, Inches O.D. |
7/8* |
Refrigerant Charge (oz) |
114 |
Power Supply |
208/230-60-1 |
Min.Circuit Ampacity |
18.6 |
Max. Overcurrent Device (Amps) |
30 |
Electric Conduit Size |
|
Power Supply |
1/2" or 3/4" |
Low Voltage |
1/2" |
Approximate Shipping Weight (lbs) |
198 |
* A 3/4 inch O.D. suction line can be used with a corresponding 1-1/2 percent reduction in cooling capacity and efficiency.
NOTE: It is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.
If installed with orifice expansion coil, orifice size 0.068 must be used (Amana part number 11076306 or B1443808).
Standard Features
•Liquid Line Dryer (Shipped for field installation)
•Automatic Reset High Pressure Switch
•Automatic Reset Low Pressure Switch
•Front Seating Valves
•Crankcase Heater
•Low RPM (825) 8 Pole Motor
•Hard Start Capacitor and Relay
Accessories
•Low Ambient Kit (LAC02A)
•Sound Blanket Kit (CSB04A)
•Liquid Line Solenoid (LSK01A)
•Freeze Protection Kit (FSK01A) (For Indoor Coil)
Effective: February 1996
Amana Refrigeration, Inc. |
11070134 |
Fayetteville, TN 37334 |