SUBBASE KIT INSTALLATION INSTRUCTIONS
ATTENTION INSTALLING PERSONNEL: As a professional installer you have an obligation to know the product better than the
customer. This includes all safety precautions and related items. Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety warnings. Remember, it is your responsibility to install the product safely and to know it well enough to be able to instruct a customer in its safe use. Most dealers have a list of specific good safety practices...follow them. The precautions listed in this Installation Manual are intended as supplemental to existing practices. However, if there is a direct conflict between existing practices and the content of this manual, the precautions listed herein take precedence.
The subbase may be installed on the wall sleeve before or after installing the wall sleeve. The subbase is prewired. Electrical connections can be made on the left side after the access cover is removed. A grounding screw is provided.
NOTE: The wall sleeve must be installed a minimum of 3¼ inches above a finished floor and a minimum of 2¾ inches from a finished wall.
WARNING
PERSONAL RISK HAZARD
To avoid the risk of
property damage, personal injury or death due to electrical shock, disconnect the electrical power
before working on this product
Subbase Assembly
Part/Location Identification
Wall
Sleeve
A Left Front Cover B Right Front Panel C Front Cord Panel
D
E
D Wall Sleeve Hole Location E Skirting Hole Location Z Right Front Cover Assembly
IMPORTANT NOTE: To avoid equipment dam­age, use copper conductors only.
Wiring
Access
NOTE:
The installation and servicing of this equipment must be performed by
A
qualified, experienced technicians only.
1. Remove (B) and (C) from the subbase and join together using two metal screws provided. This assembly now becomes the right front cover (Z) of the subbase.
2. Position subbase under the front of the wall sleeve. Locate by aligning flanges on the subbase to the wall sleeve. When positioned correctly, the subbase will extend 1-7/16" past the front of the wall sleeve.
3. Drill four 1/8-inch holes in wall sleeve to line up with holes in subbase (D). Mount subbase to wall sleeve with four sheet metal screws provided with kit (D).
4. Remove the left front cover from the subbase (A).
5. Position skirting on each side of wall sleeve to prevent the entry of foreign mate­rials. Trim skirting to desired length. Attach skirting with four sheet metal screws provided with kit (E).
6. Wire subbase for appropriate voltage (seeWiring Diagram). NOTE: The proper subbase must be ordered to obtain the correct electrical re-
ceptacle (see NEMA Plug Configurations).
7. After wiring is complete, mount covers A and Z to the subbase with provided screws.
8. When installing optional accessories to the subbase, refer to each installation instruction for that accessory.
.
IMPORTANT NOTE: Sub-
base should extend 1-7/16” past wall sleeve flange. .
D
B
S
u
b
B
b
o
a
x
s
e
A
s
s
y
.
Compartment
Z
C
Low Voltage
11-3/4"
E
B
+
3"
C
=
Z
LOCATE FLANGE ON SUBBASE
AGAINST WALL SLEEVE FLANGE.
Part No. 1 1113807 Printed in USA
January 2005
Wall Sleeve
(Outdoor Side)
2
NEMA 5-15R
Receptacle
13-3/4"
16-1/16"
3-1/4"
Left End View
NOTE: The subbase should extend into the room 1-7/16" past the w all sleeve fl an g e.
G
W
L2L1
115 VAC Field Schematic
W
BLK
L1 L2
Field Wiring Line Voltag e
GRN
G
WHT
19-9/16"
1-3/8"
Wall
Sleeve
Inside
Edge
Ground Screw Location
Back of Flange "A"
2"
19-9/16"
G
L2L1
Field Wiring
NEMA 6-15R
Receptacle
NEMA 6-20R
Receptacle
NEMA 6-30R
Receptacle
230/208 VAC Field Schematic 265 VAC Field Schematic
Line Voltage
L1 L2
BLK RED
G
L2L1
G
G
L2L1
G
W
NEMA 7-20R
Receptacle
G
W
NEMA 7-30R
Receptacle
L2L1
L2L1
W
BLK
L1 L2
Field Wiring Line Voltage
G
Receptacle
Provided
Inside Subbase
3-1/2"
Accessory
Concentric
Knockouts in Rear
Front View
3-1/2"
Concentric
Knockouts in Bottom
Top View
Subbase Dimensions
GRN
Voltage Unit Plug Subbase Receptacle
WHT
115
230/208
230/208
1-1/4"
13-1/2"
1-3/8"
Wall Sleeve
(Inside Side)
2-5/8"
2" Max. Adjustment
Back of Flange "A"
NEMA 6-15 AMP
L2
NEMA 6-20 AMP
1-1/4"
1-1/4"
4"
L1 L2
2"
L2 L1 L1 L2
L2L2L1 L1
NEMA 5 -15 AMP NEMA 5-15 AMP
G
NEMA 6-15 AMP
GG
NEMA 6-20 AMP
L1
13-3/4"
16-1/16"
1-7/16"
3-1/4"
Right End View
NOTE: The subbase should extend into the room 1-7/16" past the wall sleeve flange.
Voltage Unit Plug Subbase Receptacle
265
230/208
265
G
NEMA 7-20 AMP
W
L2
L1
G
G
W
NEMA 6-30 AMP
L1
NEMA 7-30 AMP
L1
L2
L2
L1
L1
L1
G
W
G
W
NEMA 7-20 AMP
L2
NEMA 6-30 AMP
L2
NEMA 7-30 AMP
L2
Wall
Sleeve
Outdoor
Edge
Wiring Diagram
NEMA Plug Configurations
Loading...