Amana Ap075m Owner's Manual

Page 1
R
AP075M Part Number: AC-8888-146
HAIER AMERICA
SERVICEMANUAL
PORTABLEAIRCONDITIONER
Importantpointsonservice,andoperatingsafety,
withaflow-chartforinspectionandrepair.............1
Troubleshooting...................................................3
Technicalspecifications....................................4
Refrigeratorsystemandschematicwiring
diagrams.............................................................5
Explodedview.....................................................6
Partslist..........................................................7-8
Thismanualisfortheuseoftechnicalpersonnelentrusted withmaintenance. Widetechreservestherighttochangethisdehumidifier's casing,circuitandpartswithoutnotice.
..
115V/60Hz
Page 2
1
IMPORTANTPOINTSONSERVICEOPERATINGSAFETY Pleasefollowtheseinsructionscarefully:
Unplugtheunittoavoidanydangerfromelectricshockbeforedisassemblingtheunitfor repair. Ifthereisanysoundoftherefrigerantcirculatingwheninoperation,avoidtouchingthe coolingcoils. Ifyouneedtoperformanyweldingorsoldering,besureyouareinawellventilatedarea.
Onlyaqualifiedprofessionalshouldperformanyweldingontheunit. Whenrepairingtheunit,thespecificationslistedinthismanualmustbestrictlyadhered towhenreplacinganycomponents. Whenreplacinganyelectricalcomponentstheyshouldbefactoryapprovedunits.
Besurethatanyelectricalcomponentsareproperlywiredandinplace.
FLOWCHARTFORINSPECTINGANDREPAIRINGTHEUNIT
AIRCONDITIONER WON'TSTART
AIRCONDITIONER WON'TCOOL PROPERLY
COMPRESSORWON'T START
NOPOWER
POWERTRIPPED
PLUGANDSOCKET ARELOOSE
TIMERFAILURE
PROTECTORFAILURE
CAPACITORFAILURE
CHECKTHEPOWER SWITCH
RE-PLUGINGTHE POWERSUPPLYCORD
TESTINGBY ELECTROSCOPE
CHANGETHE PROTECTOR
CHANGETHE CAPACITOR
CHANGETHESWITCH
WIRINGISLOOSE
REFRIGERANT LEAKAGE
TROUBLESHOOTING THESYSTEM
USEOXYACETYLENEANDPLUS5% SILVERSOLDERTOWELDTHE CRACKEDPOINTS
RUNNINGTEST
RUNNINGTHEVACUUM EVACUATIONFORMORE THAN15MINUTES
RE-CONNECTING
CHANGETHEAIRCONDITIONERWITH15KG/CM
NITROGENGASFROMLOW-PRESSURESIDEAND
DETECTTHELEAKINGPOINTBYSOAP
CHARGECOOLANTAND PROCEEDRUNNINGTEST
2
Page 3
APPEARANCE(OUTWARD)
TRANSPARENTCOVER
CONTROLPANEL
DISCHARGEGRILLE (COMPLETE)
TOPCOVERPLATE
HANDLE
FRONTPANEL
TURINGWHEEL
FUNCTIONS
TIMESWITCH
TIMER
CONT
8
ROTARYSWITCH
COOLING
1
2
THERMOSTATSWITCH
0 CONT
FAN
OFFOFF
THERMOSTAT
SIDEPLATE
3
7
4
6
5
WA-903
Page 4
TROUBLESHOOTING
PROBLEM POSSIBLECAUSE REMEDIES
Theairconditioner doesn'twork
Theairconditioner worksforshort periodonly
Theairconditioner switchesareoff constantly
-Thereisapowerfailure
-Theplugisnotconnected
-Thetimerisunabletowork
-Themainswitchhasnot beenpressed
-Thesettemperatureistoo closetotheroom's temperature
-Thereissomethingblocking thesuctionventonthe backofcondenser
-Thefanonthecondenseris blocked
-Malfunction
-Waitforthepowerreturn
-Connecttheplug
-Providerepairment
-Pressthemainswitch
-Decreasethesetting temperature
-Removeanyobstacles
-Providerepairment
-Turnofftheappliance
removetheplugand contacttheservicecenter
Theairconditioner worksbutitdoes notcooltheroom
Theapplianceis verynoisyand vibratesviolently
-Thereisawindowopened
-Thereisasourceofheat operatingintheroom (burner,lamp,etc.),orthe roomiscrowded
-Theairfilterisclogged
-Thecapacityoftheair conditionerisnotsuitable fortheconditionsorsize oftheroom
-Theevaporatorisfrozen
-Thecompressorblocking devicehasbeenloosenor thecopperpipeisgetting intouchwiththebodyof theset
-Closethewindow
-Remove/switchoffthe sourceofheat
-Decreasetheset temperature
-Cleanthefilter
-Cleantheairfilter
-Changethepurifierfilter, ifnecessary
-Donotmaketheappliance operatingattoolow temperature(below22
-Providerepairment
)
Page 5
TECHNICALSPECIFICATIONS
AIRCONDITIONER
ITEMUNIT
OUTERDIMENSION REFERENTIALUSING
AREA
RATEDVOLTAGE
COOLINGCAPACITY
B.T.U.
DEHUMIDIFYING CAPACITY
RUNNINGCURRENT POWER
CONSUMPTION INDOORAIRVOLUME
MODEL
INPUT POWER
mm
2
m
V/Hz
L/H
A
W
3
m/hr
W
AP075M
520W*750H*360D 1214 115/60
7500
1.25
8.7
950
250 2R12S3R126AUB 740
K1NC104ABBBBD 710
RUNNING
COMPRESSOR
MOTOR
EVAPORATOR
CONDENSER
REFRIGERANT
WEIGHT
CAPACITOR
PROTECTOR
LOCKED ROTORAMPS
MODEL OUTPUT
POWER RUNNING
CAPACITOR
uF/V
A
W
uF/V
R22/g
Kg
35/250 MRA98503/MRA98706
/MRA98706-9090
6.9
LS-40T2-4P
40
8/250
2R11S17FPI
2R9S19FPI+3R9S17FPI 440
32
55/250 T0262/46
6.23
400
REMARK
Page 6
REFRIGERSYSTEMDIAGRAM
FLOWOF
RIGERANTREF
MOTOR
SCHEMATICWIRINGDIAGRAM
Loading...