Electrical: To properly install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
■ Range must be connected to the proper electrical voltage and
frequency as specified on the model/serial number rating plate. The model/serial number rating plate is located on the left-side frame behind the storage drawer panel or behind the top right side of the oven door. Refer to the figures in the “Product Dimensions” section of the “Location Requirements” section.
■ This range is manufactured with the neutral terminal connected to
the cabinet. Use a 3-wire, UL Listed. 40- or 50-amp power supply cord (pigtail) (see following Range Rating chart). If local codes do not permit ground through the neutral, use a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for use with ranges.
120/240 Volts 120/208 Volts Amps
8.8 – 16.5 KW 7.8 – 12.5 KW 40 or 50 **
16.6 – 22.5 KW 12.6 – 18.5 KW 50
* The NEC calculated load is less than the total connected load listed on
the model/serial rating plate.
** If connecting to a 50-amp circuit, use a 50-amp rated cord with a kit.
For 50-amp rated cord kits, use kits that specify use with a nominal 13/8" (34.9 mm) diameter connection opening.
■ A circuit breaker is recommended.
AER3311WA
AER5330BA
AER5523XA
AER5524XA
Range Rating*
AER5630BA
AER5823XA
AER5830VA
AER6303MF
AER6603SF
Specified Rating of Power Supply Cord Kit and Circuit Protection
CABINET OPENING DIMENSIONS
PRODUCT DIMENSIONS
A
B
F
C
E
D
A. 273/4" (70.5 cm) max. depth with handle B. 467/8" (119.1 cm) overall height (max.) with leveling legs
screwed all the way in*
C. 36" (91.4 cm) cooktop height (max.) with leveling legs screwed
all the way in* D. 297/8" (75.9 cm) width E. 255/16" (64.3 cm) depth – back of range to front of cooktop** F. Model/serial rating plate (located on the left-side frame behind
storage drawer or right side of frame behind the oven door)
IMPORTANT: Range must be level after installation. Follow the instructions in the “Level Range” section. Using the cooktop as a reference for leveling the range is not recommended.
* Range can be raised approximately 1" (2.5 cm) by adjusting the
leveling legs.
** Front of door and drawer may extend further forward depending on
styling.
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the range, following the range hood or microwave hoods combination instructions for dimensional clearances above the cooktop surface.
A freestanding range may be installed next to combustible walls with zero clearance.
* NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet
is covered by not less than 1/4" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
Because Whirlpool Corporation includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
A. 13" (33.0 cm) max.
A
B
C
upper cabinet depth
B. 30" (76.2 cm) min.
opening width
C. For minimum clearance
to top of cooktop, see
D
NOTE*
D. 301/8" (76.5 cm) min
opening width
E. Outlet – 8" (20.3 cm)
E
to 22" (55.9 cm) from either cabinet, 51/2" (14.0 cm) max. to
F
floor
F. Cabinet door or hinges
should not extend into the cutout
Ref. W10403811C