Electrical: To properly install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
• Range must be connected to the proper electrical voltage and frequency as specied on the model/serial number rating plate. The model/serial number rating plate is located on the left side frame behind the storage drawer panel or behind the top right side of the oven door. Refer to the gures in the “Product Dimensions” section
of the “Location Requirements” section.
• This range is manufactured with the neutral terminal connected to the cabinet. Use a 3-wire, UL listed, 40- or 50-amp power supply cord (pigtail) (see following Range Rating chart). If local codes do not permit ground through the neutral, use a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for use
with ranges.
Range Rating*
120/240 Volts 120/208 Volts Amps
8.8 – 16.5 KW 7.8 – 12.5 KW 40 or 50 **
16.6 – 22.5 KW 12.6 – 18.5 KW 50
* The NEC calculated load is less than the total connected load listed
on the model/serial rating plate.
** If connecting to a 50-amp circuit, use a 50-amp rated cord with kit.
For 50-amp rated cord kits, use kits that specify use with a nominal
3
1
/8" (34.9 mm) diameter connection opening.
• A circuit breaker is recommended.
AER3311WA AER5330BA AER5523XA AER5524XA
AER5630BA AER5823XA AER5830VA
Specied Rating of Power Supply Cord Kit and Circuit Protection
CABINET OPENING DIMENSIONS
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the range, following the range hood or microwave hoods combination instructions for dimensional clearances above the cooktop surface.
A freestanding range may be installed next to combustible walls with zero clearance.
* NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet
is covered by not less than 1/4" (0.64 cm) ame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.
Because Whirlpool Corporation includes a continues commitment to improve our products, we reserve the right to change materials and specications without notice.
PRODUCT DIMENSIONS
A
F
E
D
A. 273/4" (70.5 cm) max. depth with handle B. 467/8" (119.1 cm) overall height (max.) with leveling legs
screwed all the way in*
C. 36" (91.4 cm) cooktop height (max.) with leveling legs
screwed all the way in* D. 297/8" (75.9 cm) width E. 255/16" (64.3 cm) depth – back of range to front of cooktop** F. Model/serial rating plate (located on the left side frame behind
storage drawer or right side of frame behind the oven door)
IMPORTANT: Range must be level after installation. Follow the instructions in the “Level Range” section. Using the cooktop as a reference for leveling the range is not recommended.
* Range can be raised approximately 1" (2.5 cm)
by adjusting the leveling legs.
** Front of door and drawer may extend further forward
depending on styling.
A
B
D
E
A. 13" (33.0 cm) max. upper cabinet depth B. 30" (76.2 cm) min. opening width C. For minimum clearance to top of cooktop, see NOTE*. D. 301/8" (76.5 cm) min opening width E. Outlet – 8" (20.3 cm) to 22" (55.9 cm) from either cabinet, 51/2" (14.0 cm) max. to oor
F. Cabinet door or hinges should not extend into the cutout
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specications subject to change without notice.
C
F