ALTUSEN SN0108, SN0116 User Guide

Serial Over the NET™
SN0108 / SN01 16
User Manual
www.altusen.com.tw
SN0108 / SN0116 User Manual
FCC Information
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
RoHS
This product is RoHS compliant.
SJ/T 11364-2006
The following contains information that relates to China.
ii
SN0108 / SN0116 User Manual
User Information
Online Registration
Be sure to register your product at our online support center:
International http://support.aten.com North America ATEN TECH http://www.aten-usa.com/product_registration
ATEN NJ http://support.aten.com
Telephone Support
For telephone support, call this number:
International 886-2-8692-6959 North America ATEN TECH 1-888-999-ATEN
ATEN NJ 1-732-356-1703
User Notice
All information, documentation, and specifications contained in this manual are subject to change without prior notification by the manufacturer. The manufacturer makes no representations or warranties, either expressed or implied, with respect to the contents hereof and specifically disclaims any warranties as to merchantability or fitness for any particular purpose. Any of the manufacturer's software described in this manual is sold or licensed as is. Should the programs prove defective following their purchase, the buyer (and not the manufacturer, its distributor, or its dealer), assumes the entire cost of all necessary servicing, repair and any incidental or consequential damages resulting from any defect in the software.
The manufacturer of this system is not responsible for any radio and/or TV interference caused by unauthorized modifications to this device. It is the responsibility of the user to correct such interference.
The manufacturer is not responsible for any damage incurred in the operation of this system if the correct operational voltage setting was not selected prior to operation. PLEASE VERIFY THAT THE VOLTAGE SETTING IS CORRECT BEFORE USE.
iii
SN0108 / SN0116 User Manual
Copyright © 2004-2006 ATEN® International Co., Ltd.
Manual Part No. PAPE-0241-3AXG
Printing Date: 1/2009
ATEN and the ATEN logo are registered trademarks of ATEN International Co., Ltd. All rights re served.
All other brand names and trademarks are the registered property of their respective owners.

Package Contents

The SN0108 / SN0116 package consists of:
1SN0108, SN0116, SN0108D, or SN0116D1Power Cord (SN0108 or SN0116)1Rack Mount Kit (Brackets and Phillips head hex M3 x 8 screws)1Foot Pad Set (4 pcs.)1Software CD1User Manual*1Quick Start Guide
Check to make sure that all of the components are present and in good order. If anything is missing, or was damaged in shipping, contact your dealer.
Read this manual thoroughly and follow the installation and operation procedures carefully to prevent any damage to the switch or to any other devices on the installation.
* Features may have been added to the manual since it was printed. Please visit
our website to download the most up to date version.
iv
SN0108 / SN0116 User Manual
Contents
FCC Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ii
SJ/T 11364-2006. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ii
User Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii
Online Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii
Telephone Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii
User Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii
Package Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .x
Product Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .x
Chapter 1.
Introduction
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
SN0108 / SN0108D Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
SN0116 / SN0116D Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
SN0108 / SN0116 Rear Panel (AC Power). . . . . . . . . . . . . . . . . . . . . . . . .6
SN0108D / SN0116D Rear Panel (DC Power). . . . . . . . . . . . . . . . . . . . . .7
Chapter 2.
Hardware Setup
Before you Begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Stacking and Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Stacking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Rack Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
SN0108 / SN0116 PC Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
SN0108D / SN0116D PC Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
SN0108 / SN0116 Sun Fire V100 Server Installation . . . . . . . . . . . . . . . .15
SN0108D / SN0116D Sun Fire V100 Server Installation . . . . . . . . . . . . .17
Chapter 3.
Browser Login
Logging In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
The SN0108 / SN0116 Main Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Logging Out. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
v
SN0108 / SN0116 User Manual
Chapter 4.
Administration
Working Environment Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Administrator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Connection Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Network. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Service Ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
IP Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
IP Address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
ANMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
CC Management Settings: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
SNMP Settings:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
OOBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Date / Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Firmware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Device Management Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Port Config . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Alert Settings: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
User Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Deleting an Account . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Adding an Account:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Editing an Account: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Direct Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Session Info . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Sys Info. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Chapter 5.
Browser Operation
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Telnet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Port Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
User Manager. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
vi
SN0108 / SN0116 User Manual
Chapter 6.
Out of Band Operation
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
HyperTerminal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
Direct HyperTerminal Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . .53
Logging In:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Indirect HyperTerminal Connection. . . . . . . . . . . . . . . . . . . . . . . . . . .58
Final Check:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Logging In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
PPP (Dial In) Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Direct PPP Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Finishing Up: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Logging In:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Indirect PPP Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Setup: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Final Check:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Logging In:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Telnet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Logging In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
SSH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Terminal Session (Linux): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Third Party Utility (Windows): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
Chapter 7.
Real COM Port Management
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71
Driver Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71
Windows 2000 and Higher Installation . . . . . . . . . . . . . . . . . . . . . . . .71
Windows 98 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Linux Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
Uninstalling the Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
Real COM Port Management – Windows. . . . . . . . . . . . . . . . . . . . . . . . .74
Dialog Box Layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
Menu and Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
Target Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
Target List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
Port List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
Mapped COM Ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Port Mapping and Unmapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Port Unmapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
Real COM Port Management – Linux. . . . . . . . . . . . . . . . . . . . . . . . . . . .80
Mapping/Unmapping Virtual Ports. . . . . . . . . . . . . . . . . . . . . . . . . . . .80
Virtual Port Naming Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80
vii
SN0108 / SN0116 User Manual
Appendix
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
DC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83
Rack Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85
International . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
North America. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86
SN0108 / SN0116. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86
SN0108D / SN0116D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87
Administrator Login Failure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
IP Address Determination. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89
Method 1: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89
Method 2: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
Method 3: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
RJ-45 to Serial Adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96
Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96
Limited Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
viii
SN0108 / SN0116 User Manual
About This Manual
This User Manual is provided to help you get the most from your SN0108 / SN0116 system. It covers all aspects of installation, configuration and operation. An overview of the information found in the manual is provided below.
Overview
Chapter 1, Introduction, introduces you to the SN0108 / SN0116 System.
Its purpose, features and benefits are presented, and its front and back panel components are described.
Chapter 2, Hardware Setup, provides step-by-step instructions for setting up your installation.
Chapter 3, Browser Login, explains how to log into the SN0108 / SN0116 from your browser.
Chapter 4, Administration, explains the administrative procedures that are employed to configure the SN0108 / SN0116’s working environment.
Chapter 5, Browser Operation, details concepts and procedures involved in the browser operation of your SN0108 / SN0116 installation.
Chapter 6, Out of Band Operation, describes how to set up the various serial port methods that can be used to access the SN0108 / SN0116 when the network is unavailable.
Chapter 7, Real COM Port Management, shows how to install the virtual COM port driver and to set up and manage the virtual COM ports.
An Appendix, at the end of the manual provides technical and troubleshooting information.
ix
SN0108 / SN0116 User Manual
Conventions
This manual uses the following conventions:
Monospaced Indicates text that you should key in.
[ ] Indicates keys you should press. For example, [Enter] means
1. Numbered lists represent procedures with sequential steps. Bullet lists provide information, but do not involve sequential
Indicates selecting the option (on a menu or dialog box, for
to press the Enter key. If keys need to be chorded, they appear together in the same bracket with a plus sign between them: [Ctrl+Alt].
steps.
example), that comes next. For example, Start means to open the Start menu, and then select Run.
Indicates critical information.
Run
Product Information
For information about all ALTUSEN products and how they can help you connect without limits, visit ALTUSEN on the Web or contact an ALTUSEN Authorized Reseller. Visit ALTUSEN on the Web for a list of locations and telephone numbers
International – http://www.aten.comNorth America – http://www.aten-usa.com
x
Chapter 1
Remote
SN0108
TCP/IP

Introduction

Overview

The SN0108 / SN0116 Serial over the NET™ series are control units that provide both In-Band and Out-of-Band remote serial access to up to 8 (SN0108) or 16 (SN0116) servers or other serial IT devices (hubs, routers, power management devices, etc.), via a Telnet or SSH TCP/IP connection.
Up to 8 (SN0108) or 16 (SN0116) Users can log in at the same time from any computer connected to the Internet, whether down the hall, or half way around the world. Each is able to control a separate port so that eight attached devices can be accessed at the same time.
There are four models in the series. Their similarities and differences are shown in the following table:
Model KVM Ports Power
SN0108 8 AC SN0116 16 AC SN0108D 8 DC SN0116D 16 DC
1
SN0108 / SN0116 User Manual
The SN0108 / SN0116 can work in tandem with other remote management products - such as the Altusen PN9108 Power over the NET™ remote power management system to provide convenient, reliable, and effective, remote data center device management.
Installation is fast and easy: plugging cables into their appropriate ports is all that is entailed. A choice of browser based GUI, Telnet (SSH), and VT console terminal sessions make configuration and operation smooth and convenient.
The SN0108 / SN0116's firmware is upgradeable over the Net, so you can stay current with the latest improvements simply by downloading updates from our website. With its advanced features and ease of operation, the SN0108 / SN0116 is the most convenient, most reliable, and most cost effective way to centrally manage your remote, serially connected, IT products.

Requirements

Sun's Java 2 JRE 1.4.2 or higher must be installed on your computer. Java
is available for free download from the Sun Java website:
http://java.sun.com
The devices that connect to the SN0108 / SN0116 must support the
RS-232 protocol or RS-232 terminal operations
Virtual COM port driver (Real COM port) support requires Windows 98 or
higher (Windows systems); or Linux kernel 2.2 or higher (Linux systems).
2
Chapter 1. Introduction

Features

Complete Centralized Remote Serial Management:
Remote serial access over the Internet for up to 8 (SN0108) or 16
(SN0116) servers or other serial IT devices Works in tandem with other Altusen/Aten appliances - such as the
PN0108 and PN9108 - allowing administrators to manage a wide range
of data center devices through IP connections Remote access to Serial over IP appliances, and attached devices, in
centralized manner
Session historyDC Operation (SN0108D - SN0116D)
Security:
Multi level secure user loginsPort-specific access rightsSupports Active Directory (via CC management)Supports RADIUS
Convenient Access:
Browser access with an intuitive GUI – Java applet provides SSH
connectivity with cut and paste and print screen capability Telnet client plus third party (PuTTY, etc.) client support – SSH
connectivity available via PuTTY
Console terminalDirect port addressing - via SSH to any Serial Over IP port (bypassing
the SN0108 / SN0116) Dial in Modem and Direct Access via serial applications (such as
HyperTerminal and PPP), or IP applications (such as SSH and Telnet)
Modem sharing capability via IP-forwarding [Modem support]
Sun Ready:
Hardware break suppression ensures uninterrupted Solaris server
operation
Network Interfaces:
TCP/IP, UDP/IP, HTTP, HTTPS, NTP, SNMP, Telnet, SSH, SSL, PPP10Base-T/100BaseTX, auto senseDNS, DHCP, ARP, R ADIUSPing
3
SN0108 / SN0116 User Manual
Serial Connectivity:
VT320 support – backward compatible to VT52 (VT52, 100, 220)Hardware and software flow control Real COM port support*Raw TCP Mode support with file-based sessions
Alarms and Alerts:
Client applicationsBuzzerSNMP Traps
OS Support:
WindowsMacSunLinuxUnixAIXDOS 6.2+
Code Set Support:
ISO646 - US (US ASCII)ISO8859 - 15 (Latin -9)
General:
Hot-pluggable - add and remove servers without rebootingRack mountable in 1U system rackEasy setup – plugging cables into their ports is all it takes
* With supplied Virtual COM port driver.
4

Components

12345

SN0108 / SN0108D Front Panel

SN0116 / SN0116D Front Panel

12345
Chapter 1. Introduction
No. Component Description
1 Port LEDs A Port LED lights to indicate the device attached to its
2 Reset Switch Pressing and holding this switch in for less than three
3 10/100 Mbps
Data LED
4 Link LED Flashes GREEN to indicate that a Client program is
5 Power LED
corresponding port is online. The LED flashes when data is being transmitted through its corresponding port.
seconds performs a system reset. Pressing and holding this switch in for more than three seconds returns its settings to their default status.
The LED lights ORANGE to indicate a 10 Mbps data transmission speed. It lights GREEN to indicate a 100 Mbps data transmission speed.
accessing the device. Lights when the SN0108 is powered up and ready to
operate.
5
SN0108 / SN0116 User Manual
23 41

SN0108 / SN0116 Rear Panel (AC Power)

23 41
No. Component Description
1 Power Socket The power cable from your AC source plugs in here. 2 Power Switch This is a standard rocker switch that powers the SN0108
3 LAN Port The Ethernet cable that connects the SN0108 / SN0116
4 Serial Ports The Cat 5 cables that connect to the RJ45 to Serial
/ SN0116 on and off.
to the Internet plugs in here.
adapters plug in here. (See SN0108D / SN0116D PC
Installation Diagram:, page 14, and RJ-45 to Serial Adapters, page 92.)
Note: RJ-45 to Serial adapters require a separate purchase. To purchase RJ-45 to Serial adapters, contact your dealer.
6
Chapter 1. Introduction
34 51
2

SN0108D / SN0116D Rear Panel (DC Power)

34 51
2
No. Component Description
1 Grounding
Terminal
2 DC Terminal
Block
3 Power Switch This is a standard rocker switch that powers the
4 LAN Port The Ethe rnet cable that connects the SN0108D /
5 Serial Ports The Cat 5 cables that connect to the RJ45 to Serial
Attach the wire to ground this device here.
The electric leads from your power source connect to this DC terminal block.
SN0108D / SN0116D on and off.
SN0116D to the Internet plugs in here.
adapters plug in here. (See SN0108D / SN0116D PC
Installation Diagram:, page 14, and RJ-45 to Serial Adapters, page 92.)
Note: RJ-45 to Serial adapters require a separate purchase. To purchase RJ-45 to Serial adapters, contact your dealer.
7
SN0108 / SN0116 User Manual
This Page Intentionally Left Blank
8
Chapter 2
1. Important safety information regarding the placement of this device is provided onpage 81. Please review it before proceeding.
2. Make sure that power to all the devices you will be connecting up have been turned off.

Hardware Setup

Before you Begin

Stacking and Mounting

The SN0108 / SN0116 can be placed on the desktop or it can be rack mounted, as described in the sections that follow.

Stacking

To place the SN0108 / SN0116 on the desktop stick the self-adhesive footpads that came with your package to the unit's bottom panel at the four corners.
9
SN0108 / SN0116 User Manual
Phillips head hex M3 x 6
Phillips head hex M3 x 6
x

Rack Mounting

The SN0108 / SN0116 can be mounted in a 1U system rack. The mounting brackets can screw into either the front or the back of the unit so that it can attach to the front or the back of the rack. To rack mount the unit:
1. Remove the screws at the front or the rear, as shown in the diagram below.
2. Screw the mounting brackets into the sides of the unit at the front or the rear, as shown in the diagram below.
Phillips head hex M3 x 8
Phillips head he M3 x 8
3. Slide the unit into the front or rear of the rack and secure it to the rack.
10
Chapter 2. Hardware Setup

SN0108 / SN0116 PC Installation

Refer to the Installation Diagram on page 12 (the numbers in the diagram correspond to the numbers of the steps), as you do the following:
1. For each server or serial device, plug an RJ45 to Serial adapter into its
serial port. (See RJ-45 to Serial Adapters, page 92, for details on choosing the appropriate adapter.)
Note: RJ-45 to Serial adapters require a separate purchase. To purchase
RJ-45 to Serial adapters, contact your dealer.
2. Use standard Ethernet cable to connect any available port on the SN0108 /
SN0116's rear panel to the adapter.
3. If you choose to install a serial modem for OOB operation (see Chapter 6),
use standard Ethernet cable to connect any available port on the SN0108 / SN0116's rear panel to a DTE to DCE serial adapter (see RJ-45 to Serial Adapters, page 92 for details on choosing the appropriate adapter), then plug the adapter into the modem's serial port.
Note: This step is optional.
4. Plug the cable that connects the SN0108 / SN0116 to the network or the
Internet into its LAN port.
5. Use the AC power cord provided with this package to connect the SN0108
/ SN0116's Power Socket to an AC power source.
This completes the SN0108 / SN0116 installation.
11
SN0108 / SN0116 User Manual
SN0108 / SN0116 PC Installation Diagram:
SA0142
(DB9-M, DTE - DCE)
(DB9, DCE)
Modem
3
5
4
(DB9-F, DTE - DTE)
2
1
SA0141
12
(DB9, DTE)
Chapter 2. Hardware Setup

SN0108D / SN0116D PC Installation

Refer to the Installation Diagram on page 14 (the numbers in the diagram correspond to the numbers of the steps), as you do the following:
1. For each server or serial device, plug an RJ45 to Serial adapter into its
serial port. (See RJ-45 to Serial Adapters, page 92, for details on choosing the appropriate adapter.)
Note: RJ-45 to Serial adapters require a separate purchase. To purchase
RJ-45 to Serial adapters, contact your dealer.
2. Use standard Ethernet cable to connect any available port on the SN0108D
/ SN0116D's rear panel to the adapter.
3. If you choose to install a serial modem for OOB operation (see Chapter 6),
use standard Ethernet cable to connect any available port on the SN0108D / SN0116D's rear panel to a DTE to DCE serial adapter (see RJ-45 to Serial Adapters, page 92 for details on choosing the appropriate adapter), then plug the adapter into the modem's serial port.
Note: This step is optional.
4. Plug the cable that connects the SN0108D / SN0116D to the network or
the Internet into its LAN port.
5. Connect the DC power source to the switch (refer to the installation
diagram for details).
6. Ground the switch.
This completes the SN0108D / SN0116D installation.
13
SN0108 / SN0116 User Manual
SN0108D / SN0116D PC Installation Diagram:
SA0142
(DB9-M, DTE - DCE)
(DB9, DCE)
Modem
3
6
5
+/- 36 – 75V
4
2
(DB9-F, DTE - DTE)
1
SA0141
14
(DB9, DTE)
Chapter 2. Hardware Setup

SN0108 / SN0116 Sun Fire V100 Server Installation

For each Sun Fire V100 server you wish to install, refer to the Installation Diagram on page 16 (the numbers in the diagram correspond to the numbers of the steps), as you do the following:
1. Use standard Ethernet cable to connect any available port on the SN0108 /
SN0116's rear panel to an SA0141 adapter.
2. Use standard Ethernet cable to connect the V100's LAN port to an SA0142
adapter.
3. Connect the two adapters.
Note: If you choose to install a serial modem for OOB operation
(see Chapter 6), refer to step 3 of the PC installation procedure (see page 11).
4. Plug the cable that connects the SN0108 / SN0116 to the network or the
Internet into its LAN port.
5. Use the AC power cord provided with this package to connect the SN0108
/ SN0116's Power Socket to an AC power source.
This completes the SN0108 / SN0116 installation.
15
SN0108 / SN0116 User Manual
5
3
1
4
2
SA0141
SA0142
SunFire
V100
Server
SN0108 / SN0116 Sun Fire V100 Server Installation Diagram
16
Chapter 2. Hardware Setup

SN0108D / SN01 16D Sun Fire V100 Server Installation

For each Sun Fire V100 server you wish to install, refer to the Installation Diagram on page 18 (the numbers in the diagram correspond to the numbers of the steps), as you do the following:
1. Use standard Ethernet cable to connect any available port on the SN0108D
/ SN0116D's rear panel to an SA0141 adapter.
2. Use standard Ethernet cable to connect the V100's LAN port to an SA0142
adapter.
3. Connect the two adapters.
Note: If you choose to install a serial modem for OOB operation
(see Chapter 6), refer to step 3 of the PC installation procedure (see page 13).
4. Plug the cable that connects the SN0108D / SN0116D to the network or
the Internet into its LAN port.
5. Connect the DC power source to the switch (refer to the installation
diagram for details).
6. Ground the switch.
This completes the SN0108D / SN0116D installation.
17
SN0108 / SN0116 User Manual
SN0108D / SN0116DSun Fire V100 Server Installation Diagram
SunFire
V100
Server
6
+/- 36 – 75V
SA0141
1
4
5
SA0142
2
3
18
Chapter 3

Browser Login

Logging In

SN0108 / SN0116 operation is Internet browser based. To begin:
1. Open your browser and specify the IP address of the SN0108 / SN0116
you want to access in the browser's URL location bar.
Note: 1. Get the IP address from the SN0108 / SN0116 administrator.
2. If you are the administrator, and are logging in for the first time, the various ways to determine the SN0108 / SN0116's IP address are described in the Appendix on p. 89.
2. A Security Alert dialog box appears. Accept the certificate.
3. A login dialog box, like the one below, appears:
4. Provide a valid Username and Password (set up by the administrator), then
Click Login to continue.
Note: If you are the administrator, and are logging in for the first time, use
the default Username: administrator; and the default Password: password. For security purposes, we strongly recommend you remove these and give yourself a unique Username and Password (seeGeneral, page 21).
19
SN0108 / SN0116 User Manual

The SN0108 / SN0116 Main Screen

After you have successfully logged in, the Main Screen appears:
Except for the Logout icon, the icons arranged horizontally across the top
are only enabled for the administrator. Administrative functions are explained in Chapter 4.
Note: Be sure to click the Logout icon when you end your session.
The bar along the left side is used to configure and control access to each
of the SN0108 / SN0116's COM ports. The functions of each of the buttons is described in Chapter 5.
Unless you need to perform administrative functions, yo u can skip
to Chapter 5 now.

Logging Out

Click the Logout icon to end your SN0108 / SN0116 session.
20
Chapter 4

Administration

Working Environment Configuration

The icon bar across the top of the SN0108 / SN0116 web page is used by the administrator to configure its working environment.
An explanation of the functions is given in the sections that follow.
Note: The icons at the top of the page are disabled for all but the administrator .
Only Logout is active for everyone else.

General

When you click the General icon, the following dialog box appears:
21
SN0108 / SN0116 User Manual
The dialog box is divided into three main panels:
System Information
The System Information section allows you to provide a name and description for the SN0108 / SN0116 Station. Providing a Station Name and Station Description is optional, but makes it convenient to differentiate the Stations in large, multistation installations.
Administrator
This section sets the administrator's login name and password.
The default administrator name is: administratorThe default password is: password
For security purposes, we strongly recommend that you change the default values to something unique.
The Comments field is optional. It provides administrators with a place to enter personal comments.
Connection Control
Session Timeout sets a timeout value. If there is no input from the logged in operator for the amount of time set with this function, the operator is automatically logged out and the session is terminated. Valid settings are from 0 ~ 255 minutes. A setting of 0 (zero) disables this function. The default is 3 minutes.
22
Chapter 4. Administration

Network

Network Configuration allows you to set up the network parameters for the SN0108 / SN0116:
Service Ports
Lets you select the service ports that the SN0108 / SN0116 listens for incoming data on. Unless you have a specific reason for changing them, we recommend you leave the default settings as they are.
IP Installer
Click a radio button to Enable/Disable the IP Installer utility (see Method 1:, page 89, for IP Installer details).
Note: If you choose View Only, the utility will be enabled as far as showing
the SN0108 / SN0116 in the Device List, but you will not be able to use it to assign IP addresses.
23
SN0108 / SN0116 User Manual
IP Address
The default is for a fixed IP address. To give the SN0108 / SN0116 a fixed IP address, fill in the Primary IP to Alternate DNS Server fields with values appropriate to the network you are on.
To have the Station obtain its IP address automatically from a DHCP server, put a check in the Obtain an IP address automatically [DHCP] checkbox.
To have your SMTP server email the DHCP-generated IP address to you, do the following:
1. Enable the Enable report from the following SMTP server checkbox, and key in the IP address of your SMTP server.
2. If your server requires authentication, put a check in the My server requires authentication checkbox.
3. Key in the appropriate account information in the Account Name, Password, and From fields.
4. Key in the email address of where you want the report of the DHCP address sent to in the To field.
5. When all of your configuration settings have been made, click Update to save the information and have the SN0108 / SN0116's DHCP generated IP address emailed to you.
Note: If the SN0108 / SN0116 is on a network that uses DHCP to assign
network addresses, and you don't know what the address is, there are several methods you can use to ascertain it. See IP Address Determination, page 89 for details.
24

ANMS

The Authentication Network Management Service dialog box allows you to set up login authorization management from external sources.
It is divided into three main panels, as described below:
Chapter 4. Administration
CC Management Settings:
If you want to allow authorization for the SN0108 / SN0116 through a CC (Control Center) server, check Enable CC Management and fill in the CC Server’s IP address and the port that it listens on in the appropriate fields.
(Continues on next page.)
25
SN0108 / SN0116 User Manual
(Continued from previous page.)
RADIUS Settings:
If you want to allow authorization for the SN0108 / SN0116 through a RADIUS server, do the following:
1. Check Enable RADIUS.
2. Fill in the IP addresses and Service Ports for the Primary and Alternate RADIUS servers.
3. Key the Shared Secret character string that you want to use for authentication between the SN0108 / SN0116 and the RADIUS Server.
4. Set the time in seconds that the SN0108 / SN0116 waits for a RADIUS server reply before it times out in the Timeout field.
5. Set the number of RADIUS retries allowed in the Retries field.
6. Click Save to save the information.
7. On the RADIUS server, set the access rights for each user according to the attribute information in the table, below:
Attribute Meaning
U (User) The user has the authority to access and configure some
T (True) The user has the authority to access and configure the ports
F (False) The user cannot configure any ports. A (All) The user has the authority to access and configure all ports.
ports. This attribute must be specified for all users who access the system.
that are specified with it.
Example:
U,T,2,3,5,6,12,16
The user can access and configure ports 2, 3, 5, 6, 12, and 16.
Note: 1. The characters are not case sensitive. Upper or lower case work
equally well.
2. Characters are comma delimited.
3. An invalid character in the string will prohibit access to the SN0108 / SN0116 for the user.
26
Chapter 4. Administration
SNMP Settings:
If you want to use SNMP to help with your installation management:
1. Check Enable SNMP Agent.
2. Once SNMP Agent has been enabled, the SNMP Trap checkbox becomes active. If you want to enable SNMP trapping, click to put a check in the checkbox.
3. Key in passwords for the Community Name fields. We recommend replacing the defaults (public, private) with an alphanumeric string of at least 8 characters.
4. Key in the IP addresses of the computers that will automatically be notified of SNMP trap events in the SNMP Manager fields.
5. When you have finished making all your entries, click Save, to save them.
Note: MIB definitions for the SN0108 / SN0116 are provided on the CD that
came with this package.
27
SN0108 / SN0116 User Manual

OOBC

OOBC (Out of Band Configuration), provides the ability to access the SN0108 / SN0116 via a serial connection. This can either be a direct
serial connection from a local computer, or a dial in connection via modem. When you click the OOBC icon, the following dialog box appears:
1. Select which port will be used for the Console Port. The Console Port is the one that you connect the terminal or modem to for OOB communication. The default is Port 1 (COM1), but you can use any of the ports as long as you specify which one it is, here.
2. Specify the SN0108 / SN0116's IP address in the ServerIP field.
3. Specify the IP address of the device that will connect to the SN0108 / SN0116 in the ClientIP field.
4. Click Update to save the information.
The various ways to access the SN0108 / SN0116 with an OOB connection, are described in Chapter 6.
28

Date / Time

The Date / Time function allows you to set the SN0108 / SN0116's date and time. When you click the Date / Time icon, the following
dialog box appears:
Chapter 4. Administration
The date and time that the SN0108 / SN0116 is currently set to appear in the upper section. The large middle section offers three methods to set new date and time parameters:
Synchronizing the date and time with your computer's date and timeSetting the date and time manuallySynchronizing the date and time with the date and time of an NTP server
on the internet
Note: 1. If you enable Synchronize with computer time, the Date and Time
fields are filled with the date and time settings of your computer.
2. If you enable Set Manually, key in the Date and Time in the corresponding fields.
3. If you enable Synchronize with NTP server, select the time zone that corresponds to the SN0108 / SN0116's location from the list box in the Time Zone panel. If you are behind a firewall, you must enable a port for the NTP server.
Click Save to save your changes.
29
SN0108 / SN0116 User Manual

Firmware

The Firmware Upgrade function provides a smooth, automated
process for upgrading the SN0108 / SN0116's firmware. New firmware upgrade packages are posted on our web site as they become available. Check the site regularly to find the latest packages.
To upgrade your firmware, do the following:
1. From your computer, go to our Internet support site and choose the
SN0108 / SN0116 to get a list of available Firmware Upgrade Packages.
2. Choose the Firmware Upgrade Package you want to install (usually the
most recent), and download it to your computer.
3. From the computer that you downloaded the upgrade file to, log into the
SN0108 / SN0116.
4. Click the Firmware icon. A dialog box similar to the one below appears:
5. Click the Browse button; navigate to the upgrade file on your computer,
and select it.
6. Click Upgrade to perform the upgrade.
Note: 1. If you enable Check Firmware Version, the upgrade function
compares the station's firmware level with that of the upgrade files. If it finds that the SN0108 / SN0116's current version is equal to, or higher than, the upgrade version, it won't overwrite the SN0108 / SN0116's version.
2. If you do not enable Check Firmware Version, the Utility installs the upgrade files without checking whether they are a higher level, or not.
30
Chapter 4. Administration

Device Management Configuration

The buttons in the bar along the left side of the SN0108 / SN0116 web page are used to manage and access the devices connected to the SN0108 / SN0116's COM ports.
This section discusses the functions available to administrators and, in the case of port configuration, users with configuration permission. The functions available to ordinary users are discussed in Chapter 5, Browser Operation.

Port Config

The administrator and users with port configuration permission (seeUser Manager, page 36), can set up the operating parameters for each of the SN0108
/ SN0116's ports by clicking the Port Config button to bring up the Port Configuration dialog box:
(Continues on next page.)
31
SN0108 / SN0116 User Manual
(Continued from previous page.)
Property Settings
To set up the serial communications parameters for a port, select it, then click the Property Settings button at the bottom of the page:
The meanings of the settings are given in the following table:
Setting Meaning
Port ID Each port on the SN0108 / SN0116 has a port ID number (COM1 -
Port Name You can give a port an appropriate name by editing the Port Name
Baud Rate This sets the port’s data transfer speed. Choices are from 300 –
Data Bits This sets the number of bits used to transmit one character of data.
COM8 for the SN0108, or COM1 - COM16 for the SN0116). The Port ID field displays the number of the port that is being configured.
field.
115200 (drop down the list to see them all). Set this to match the baud rate setting of the connected device. Default is 9600 (which is a basic setting for many serial devices).
Choices are: 5, 6, 7 and 8. Set this to match the data bit setting of the connected device. Default is 8 (which is the default for the majority of serial devices).
(Continues on next page.)
32
Chapter 4. Administration
(Continued from previous page.)
Setting Meaning
Parity This bit checks the integrity of the transmitted data. Choices are:
Stop Bits This indicates that a character has been transmitted. Set this to
Flow Control This allows you to choose how the data flow will be controlled.
Enable Toggle DTR
Online Detect This allows you to set the DSR signal to detect online status or not.
Out CRLF Translation
Suspend Character
Even, Odd, None, Mark, and Space. Set this to match the parity setting of the connected device. Default is None (which is the default for the majority of serial devices).
match the stop bit setting of the connected device. Choices are: 1,
1.5, and 2. Default is 1 (which is the default for the majority of serial devices).
Choices are: None, Hardware (RTS/CTS), and XON/XOFF. Set this to match the flow control setting of the connected device. Default is None.
Enabling this parameter allows the DTR signal to toggle between disabled and enabled when the port is occupied. Choices are: No, and Yes. Default is No.
Note: For some devices, in order for Enabled to work correctly, you must first disable DTR (select No, then click Update), then Enable it (select Yes, then click Update).
Choices are: None and DSR. Default is DSR. This allows you to select whether to send a Carriage Return and Line
Feed signal (CRLF), or only a Carriage Return signal (CR). Choices are: None (which sends CRLF) and CRLF to CR (which only sends CR), Default is None.
Note: If your device outputs double spaced lines, it means that a line feed is automatically added to a carriage return signal. In that case, choose CRLF to CR.
The Suspend character is used to bring up the Suspend Menu in Telnet sessions (seeTelnet, page 47).
Note: Valid characters are from A—Z, except H, I, J, and M. Those four characters may not be used.
(Continues on next page.)
33
SN0108 / SN0116 User Manual
(Continued from previous page.)
Setting Meaning
Operating Mode The choices are:
Console Management: In this mode, users establish a Telnet or
SSH session under the SN0108 / SN0116 to manage a server or serial device connected to the port. Users can log in using the browser Telnet function, a direct Telnet session, SSH or PuTTY. This mode can also be used for Out-of-Band operation via the SN0108 / SN0116’s Console Port. SeeOut of Band Operation, Chapter 6.
Raw TCP Mode: This mode is used with socket programming to
directly control the device’s data transmission without the need for serial port control or serial modem signal control. Only data is transmitted (using IP as the protocol).
Note: When you use the IP address you must also specify the port number. For example:
192.168.0.200 5003. For security purposes, access to the port can be limited to
specific IP addresses. See Direct Access, page 39, for further details.
Real COM Port: Used with a virtual COM port driver on the local
machine (See Real COM Port Management, Chapter 7 for virtual port management details.) The device connected to this port appears as if it were a device directly connected to a COM port on the local computer. Data transmission between the device and the local computer takes place over the virtual COM port to the SN0108 / SN0116.
This mode is useful with serial devices such POS terminals, Bar Code Readers, Serial printers, etc. In addition, this mode can be used with other Altusen management products, such as the PN9108 Power Over the NET™.
As with Raw TCP Mode, access to the port can be limited to specific IP addresses with the Direct Access function (see page 39).
Timeout If there is no input on this port for the amount of time set here, the
Authorized Operators
port is released for use by another user. Note: This field does not appear if the port is selected as a
Console port. (See OOBC, page 28, for selection details.) The Authorized Operators field indicates the users that are
authorized to operate the port (seeUser Manager, page 36). The information in this field is for viewing purposes only. It can't be changed on this page.
When you have finished making your choices, click Update to save them.To abandon your choices without saving them, simply leave the page.
34
Chapter 4. Administration
Alert Settings:
The Port Alert Settings dialog box provides a way for you to be informed via email about problems that may occur on the devices connected to the SN0108 / SN0116's ports. When a device has a problem - such as a critical error that requires a reboot - debug messages can be sent through its COM port.
Note: This function only works when the Operating Mode is set to Console
Management (see Operating Mode, page 34).
When the SN0108 / SN0116 receives such a message, it can send an email to inform the user specified here of the problem. You can have up to 10 types of alert emailed to you when a device generates them.
To configure a port to provide alert notification, do the following:
1. Select it in the Select column of the Port Configuration dialog box (see page 31), then click the Alert Settings button. A dialog box, similar to the one below, appears:
2. Use the Alert String fields to specify the alerts you want to receive.
35
SN0108 / SN0116 User Manual
3. Enable the Enable report to the following address checkbox, and key in the IP address of your SMTP server.
4. If your server requires authentication, put a check in the My server requires authentication checkbox.
5. Key in the appropriate account information in the Account Name, Password, and From fields.
6. Key in the email address of where you want the report sent to in the To field.
7. When all of your configuration settings have been made, click Update to save the information.
After setting up this page, whenever one of the specified alerts is generated, you will be informed by email of its occurrence.

User Manager

Clicking the User Manager button brings up the User Management dialog box. If this is the first time you are accessing this function, or no user accounts have been created yet, the following screen displays:
Click New to begin setting up user accounts. See p. 37 for adding, editing, and deleting user accounts.
36
Chapter 4. Administration
If user accounts have been set up, the User Manager dialog box appears:
This dialog box allows the administrator to add, delete, and edit user accounts. Up to 15 user accounts can be established. Operators must provide the Usernames and Passwords established here, in order to log in.
Deleting an Account
To delete a user account, select it and click Delete.
Adding an Account:
To add a user, click Add. The User Information dialog box appears:
1. Key in the user’s Username and Password (up to 16 characters for each).
2. Reenter the password to confirm that it is correct.
3. Key in any Comments you wish to make concerning the user. (optional)
37
SN0108 / SN0116 User Manual
4. If you want the user to have Port Configuration permission, put a check in the Port Config Permission checkbox. Otherwise, leave it blank.
Note: 1. Port Configuration is where the Port Numbers and Names that
appear in this dialog are set. See Port Config, page 31 for port configuration information.
2. The term “Yes” in the Shared column means that other users have access permission to the port.
5. If there are any ports that you do not want the user to access, remove the check from the Enable checkbox.
6. Click Add to save your changes.
Editing an Account:
1. To Edit a user account, select the user, then click Edit. The user’s User Information dialog box appears:
2. Make your changes in the appropriate fields and checkboxes.
3. T o save your changes, click Update.
4. To exit without saving any changes, click Back.
38
Chapter 4. Administration

Direct Access

For security purposes, Direct Access can limit the users attempting to log in to RAW TCP ports or Real COM ports (seeOperating Mode, page 34).
If no IP addresses are specified on this page, anyone can open a TCPIP Telnet session to a RAW TCP or Real COM port by specifying the IP address and port number of the port – without having to specify a Username and Password.
Once specific IP addresses are entered here, however, only users logging in to the SN0108 / SN0116 from one of those IP addresses can have access to the RAW TCP or Real COM ports without having to specify a Username and Password.
Note: Ports must be designated as a RAW TCP or Real COM ports under the
Port Config settings. See Operating Mode, page 34, for further details.
39
SN0108 / SN0116 User Manual

Session Info

Clicking the Session Info button brings up the Active Sessions display:
This display lets the administrator see at a glance all the users currently logged into the SN0108 / SN0116, and provides information about each of their sessions.
It also gives the administrator the option of forcing a user logout by selecting the user and clicking End Session.
40
Chapter 4. Administration

Sys Info

The System Information dialog box provides information about all aspects of the SN0108 / SN0116's configuration:
41
SN0108 / SN0116 User Manual
Log
Clicking the Log button brings up the Event Log dialog box:
The SN0108 / SN0116 maintains a log file of the events that take place on it. This dialog box allows you to select the range of events you wish to view:
Choose Today then click OK to see a listing of only today's events.Choose All then click OK to see a listing of events for the entire log file.Choose Selected; key in the desired range of dates in the From and To
fields; then click OK to see a listing of events for a specific time period.
Note: The maximum number of events contained in the log file is 512. Once
that amount is reached, the oldest events are discarded as new ones are recorded.
42
(Continues on next page.)
Chapter 4. Administration
(Continued from previous page.)
Once you make a choice and click OK an Event Log List, similar to the one below, appears:
When you have finished viewing the event list:
To return to the Event Log dialog box, click Back.To erase the contents of the entire log file, click Clear ALL Log.To exit, select a different function from the button bar.
43
SN0108 / SN0116 User Manual
This Page Intentionally Left Blank
44
Chapter 5

Browser Operation

Overview

Once you have logged in and the Main Screen appears (see The SN0108 / SN0116 Main Screen, page 20).The bar along the left side is used to configure
and control access to each of the SN0108 / SN0116's COM ports. The functions of each of the buttons is described in the following table:
Button Authorization Function
All Clicking this button brings up the Serial Port
All Clicking this button brings up the Telnet page.
Administrator and Permitted Users
All This button has two effects depending on
Status screen. This is the same screen that displays after a log in (see page 20). Users can see the status of each of the devices attached to the SN0108 / SN0116's COM ports.
This page allows the administrator and all users to open telnet sessions to connect to the devices attached to the SN0108 / SN0116's COM ports. See p. 47 for details.
This page allows the administrator and users with configuration permission (seeUser Manager, page 36), to set up the COM port parameters for each of the SN0108 / SN0116's COM ports (seePort Config, page 31).
whether the administrator or an ordinary user clicks it:
The administrator can use this function to
Create, Edit, and Delete user profiles (seeUser Manager, page 36, for details).
Ordinary users can only use this function to
change their passwords and personal information (see p.User Manager, page 51).
Note: Operators who have logged in via a RADIUS server (seeRADIUS Settings:, page 26) can view User Manager information, but cannot make any changes to that information.
(Continues on next page.)
45
SN0108 / SN0116 User Manual
(Continued from previous page.)
Button Authorization Function
Administrator Only
Administrator Only
Administrator Only
Administrator Only
For security purposes, Direct Access can limit the users attempting to log in to ports that have been specified as RAW TCP Ports and Real COM Ports (seeOperating Mode, page 34).
This page allows the administrator to see information about all the users who are currently logged into the SN0108 / SN0116 (see p. 40)
This page shows information about the SN0108 / SN0116's configuration (see p. 41)
Clicking this button brings up the Event Log dialog box which allows the administrator to view all of the events that took place on the SN0108 / SN0116 (see p.42 for details).
Note: 1. Buttons are only active for the functions that the user is authorized to
perform.
2. Administrator functions (inc luding Port Config) are discussed in Chapter 4.
3. The Telnet, and User Manager operations are discussed in the sections that follow.
46
Chapter 5. Browser Operation

Telnet

To access any of the device attached to the SN0108 / SN0116's COM ports, click the Telnet button. A screen similar to the one below appears:
1. Select the port you would like to access.
Note: You must have permission in order to access a port (see User
Manager, page 36 for details).
2. If you want to view the port history, click the View History button. A screen showing the Telnet activity that took place on the device connected to the port appears. Click the browser's Back button to return to the Telnet page.
47
SN0108 / SN0116 User Manual
3. To access the device connected to the port, click Connect.
The SN0108 / SN0116 opens a Telnet session and a screen similar to the one below appears:
4. If you are connected to a computer and want to go to a terminal session or
command line to operate it, Press [Enter]. When you have finished with the session, log out, then bring up the Main Menu.
Note: Be sure to log out before bringing up the Main Menu, otherwise,
another user can access the device without having to log in.
5. If you are connected to another device, enter the command that brings it
up. For example, if you are connected to a PN9108, key in: [???] [Enter]
(Continues on next page.)
48
Chapter 5. Browser Operation
(Continued from previous page.)
6. To display the Suspend Menu, Press [Ctrl+x]. Where x represents the Suspend Character set by the Administrator (see
the Property Settings dialog box under Port Configuration, p. 32). The screen will prompt you as to the correct character. In this example, it is [Ctrl+D] (see the prompt on the previous screenshot). The following screen appears:
7. Press 1 to issue a Send Break command to the attached device. This is used to put a Sun system in OK Mode.
8. Press Q to bring up the Main Menu:
49
SN0108 / SN0116 User Manual
The Main Menu is the text based equivalent of the browser configuration and control functions. The descriptions and explanations for the Browser Operations apply to the submenu functions presented here, as well.
Note: 1. As with the browser version, access to many of these submenus
are restricted to the administrator or users with configuration permission. If you select a submenu that you are not authorized for, nothing will happen.
2. Some of the submenus do not have an Exit choice. In these cases, you can return to the previous menu without making any changes by pressing Enter twice.
3. You can bring up the Main Menu at any time during your session.
When you have finished with your session, bring up the Main Menu and press Q to log out.
50
Chapter 5. Browser Operation

Port Configuration

Since only the administrator and users with port configuration permission can access this function, it is discussed in the Administration chapter (seePort Config, page 31).

User Manager

For users, clicking the User Manager button brings up their User Information dialog box:
They can use this dialog box to change their password and Comments information
 To save any changes, click Update.  To exit without saving any changes, click Back.
51
SN0108 / SN0116 User Manual
This Page Intentionally Left Blank
52
Chapter 6

Out of Band Operation

Overview

In case the network goes down, or the SN0108 / SN0116 cannot be accessed with the usual browser based method for some other reason, the SN0108 / SN0116 can be reached via several additional Out of Band (OOB) methods. These include HyperTerminal, PPP, Telnet, and SSH. Each of these is described in the sections that follow.

HyperTerminal

HyperTerminal is a program included with Windows. It can be used to establish either a direct terminal connection, or an indirect (phone in) terminal connection. Both configurations are discussed below.

Direct HyperTerminal Connection

Setup:
To set up a direct HyperTerminal connection, do the following:
1. Use Ethernet cable and a DTE-to-DTE adapter to connect one of the SN0108 / SN0116's serial ports to a COM port on a PC (see the Installation section, pages 13 and 14).
Note: 1. See RJ-45 to Serial Adapters, page 92, for details on choosing the
appropriate adapter. The usual choice for connecting to a PC is SA0141.
2. In the examples that follow we use COM1. If you use a different COM port, change the settings accordingly.
3. Be sure that the port you specify as the Console Port in the OOBC dialog box (seeOOBC, page 28) matches the port that you are connecting the PC to. Change the setting, if necessary.
53
SN0108 / SN0116 User Manual
2. On your PC, run the HyperTerminal program:
Start Programs Accessories Communications HyperTerminal Hypertrm.exe
The following dialog box appears:
3. Key a name to describe the connection in the Name field (we chose
Com1Test); select an icon to represent the connection; then click OK. A dialog box similar to the one below comes up:
54
Chapter 6. Out of Band Operation
4. For the Connect using: field, select Direct to COM1 (assuming you are
using COM1 on your PC), then click OK. A Port Setting dialog box similar to the one below comes up:
5. For OOBC connections, the SN0108 / SN0116's serial port settings and the computer's COM port settings must be the same. Change the settings in your dialog box (if necessary), so that they match the SN0108 / SN0116's Console Port settings (seePort Config, page 31, for details), then click OK.
Note: The SN0108 / SN0116's default settings are 9600 bps; 8 Data bits;
No Parity; No Stop bits, but you can change these to something more suitable to your installation as long as they both match.
55
SN0108 / SN0116 User Manual
6. When the HyperTerminal screen appears, open the File menu and select: Properties Settings. The following dialog box displays:
7. Change the settings (if necessary), so that they match the settings shown in the dialog box, then click ASCII Setup... The ASCII Setup dialog box comes up:
:
8. Change the settings (if necessary), so that they match the settings shown in the dialog box, then click OK.
56
Chapter 6. Out of Band Operation
9. Close the HyperTerminal Window. When Windows asks if you want to
disconnect, click Yes. When Windows asks if you want to save the session, click Yes.
This completes the HyperTerminal setup. For Windows NT, 2000, XP and Windows Server 2003 systems, a HyperTerminal icon that connects you to the SN0108 / SN0116 is created on the desktop. For Windows 98 and ME, you must access HyperTerminal from the Windows Start Menu.
Logging In:
1. Double click the HyperTerminal icon on your desktop.
2. In the VT100 terminal window, key in:
[Ctrl + D]
A login prompt appears.
3. Key in your Username and Password to bring up the SN0108 / SN0116's
main menu.
57
SN0108 / SN0116 User Manual

Indirect HyperTerminal Connection

This method uses HyperTerminal to phone into the SN0108 / SN0116 from a remote location.
Setup:
1. Set up your hardware configuration to match the diagram, below
:
SN0108 / SN0116
Serial Modem Cable
Phone Line
Ethernet Cable
DTE to DCE
Adapter
Remote
Operator
Modem Modem
On the remote computer side, use a standard 9 pin serial modem cable
(pin 2 to pin 2; pin 3 to pin 3) to connect the computer to the modem.
On the SN0108 / SN0116 side, use Cat 5 cable and an RJ-45 to Serial
adapter to connect a modem to any of its serial ports (see theSN0108D
/ SN0116D PC Installation Diagram:, page 14). Also see RJ-45 to Serial Adapters, page 92, for details on choosing the appropriate
adapter. The usual choice for connecting to a modem is SA0142.
Note: Be sure that the port you specify as the Console Port in the OOBC
dialog box (see p. 28) matches the port that you connect the modem to. Change the setting, if necessary.
2. Create a HyperTerminal connection. a) Start with Step 2 of the Direct HyperTerminal Setup section (p. 54). b) For Connect using: in Step 4, select the type of modem connected to
your computer from the list. If your modem doesn't appear in the list, select Standard 28800bps Modem.
c) Follow Steps 5-9 to complete the setup and create the connection icon.
58
Chapter 6. Out of Band Operation
This completes the HyperTerminal setup. For Windows NT, 2000, XP and Windows Server 2003 systems, a HyperTerminal icon that connects you to the SN0108 / SN0116 is created on the desktop. For Windows 98 and ME, you must access HyperTerminal from the Windows Start Menu.
Final Check:
To make sure that the modem and COM port are correctly installed:
1. Open the Control Panel:
My Computer Control Panel
2. Open the Make New Connection folder.
If all went well, you should see an entry with the name you assigned for this connection.
3. Open the Device Manager:
My Computer Control Panel System Device Manager
Your Modem and Ports entries should look similar to the image below
.
59
SN0108 / SN0116 User Manual

Logging In

1. Double click the HyperTerminal icon on your desktop.
2. In the VT100 terminal window, key in:
atdt [modem telephone number] [Enter]
The terminal responds with:
CONNECT115200
3. Wait at least 60 seconds, then key in:
[Ctrl+D]
4. Key in your Username and Password to bring up the SN0108 / SN0116's Main Menu.
60
Chapter 6. Out of Band Operation

PPP (Dial In) Connection

This type of connection works directly through the COM port.

Direct PPP Connection

Setup:
To set up a direct PPP connection, do the following:
1. Use Ethernet cable a DTE-to-DTE adapter to connect one of the SN0108 /
SN0116's serial ports to a COM port on a PC (refer to SN0108 / SN0116 PC Installation, page 11 or SN0108D / SN0116D PC Installation, page 13, if necessary).
Note: 1. See RJ-45 to Serial Adapters, page 92, for details on choosing the
adapter. The usual choice for connecting to a PC is SA0141.
2. In the examples that follow we use COM1. If you use a different COM port, change the settings accordingly.
2. On your PC, run the Make New Connection setup program:
Start Programs Accessories Communications Make New Connection
The following dialog box appears:
3. Key a descriptive name for the connection in the top text box; select
Standard 28800 bps Modem for the device; then click Configure.
61
SN0108 / SN0116 User Manual
4. In the Modem Properties dialog box that comes up change the dialog box settings (if necessary), so that the COM port is correct, then click OK.
5. Click the Connection tab to see the connection setup page:
6. Change your settings (if necessary), so that they match the settings shown in the figure above then click Advanced.
62
Chapter 6. Out of Band Operation
7. In the Advanced Connection Settings dialog box enable Use flow control;
select Hardware (RTS/CTS); then click OK to return to the Connection page.
8. Click OK (at the bottom of the Connection page; then click Next. The
following dialog box appears:
9. Key in anything you like for these fields, then click Next.
10.Click Finish.
A new icon that you can use to connect to the SN0108 / SN01 16 is created in the Dial-up Network folder. This completes the Direct Dial In setup.
63
SN0108 / SN0116 User Manual
Finishing Up:
The SN0108 / SN0116's serial port settings and the computer's COM port settings must be the same. Change the SN0108 / SN0116's settings for the port you are connecting the computer to (seePort Config, page 31), so that they match the ones you just set in the dialog boxes (as shown in the table below):
Parameter Value
Bit per second: 115200
Data bits: 8
Parity: None
Stop bits: 1
Flow control: Hardware (RTS/CTS)
Logging In:
1. Double click the icon you created in the Dial-up Network folder.
2. Key in your Username and Password, then click Connect.
3. Use Telnet, SSH, or your browser to access the SN0108 / SN0116 the same way as if you were accessing it over the net.
64
Chapter 6. Out of Band Operation

Indirect PPP Connection

This method uses a modem connection to phone into the SN0108 / SN0116 from a remote location.
Setup:
1. Set up your hardware configuration to match the diagram, below:
SN0108 / SN0116
Serial Modem Cable
Phone Line
Remote
Operator
Modem Modem
Ethernet Cable
DTE to DCE
Adapter
On the remote computer side, use a standard 9 pin serial modem cable
(pin 2 to pin 2; pin 3 to pin 3) to connect the computer to the modem.
On the SN0108 / SN0116 side, use Cat 5 cable and an RJ-45 to Serial
adapter to connect a modem to any of its serial ports (see theSN0108D
/ SN0116D PC Installation Diagram:, page 14). Also see RJ-45 to Serial Adapters, page 92, for details on choosing the appropriate
adapter. The usual choice for connecting to a modem is SA0142.
Note: Be sure that the port you specify as the Console Port in the OOBC
dialog box (see p. 28) matches the port that you connect the modem to. Change the setting, if necessary.
2. Set up your connection configuration as specified in Steps 2 - 8 of the
Direct Dial In Connection, section (see page 61).
3. For Step 9, key in the SN0108 / SN0116's modem telephone number in the
fields provided, then click Next.
4. Click Finish.
A new icon that you can use to connect to the SN0108 / SN01 16 is created in the Dial-up Network folder. This completes the Indirect Dial In setup.
65
SN0108 / SN0116 User Manual
Final Check:
To make sure that the modem and COM port are correctly installed, follow the procedures described under Final Check on p. 59.
Logging In:
1. Double click the icon you created in the Dial-up Network folder.
2. Key in your Username and Password; click Connect and wait for the Authentication procedure to complete (be patient, it may take a few moments).
3. Use Telnet, SSH, or your browser to access the SN0108 / SN0116 the same way as if you were accessing it over the net.
66
Chapter 6. Out of Band Operation

Telnet

Logging In

1. On your computer, open a terminal (command line) session.
2. At the prompt, key in the SN0108 / SN0116's IP Address in the following
way:
telnet [IP Address]
Note: The default telnet port is 23. If that port is already being used, up to
16 additional users can log in by adding a port number (from 5000 to 5015) to the login command. For example:
telnet [IP Address]5001
3. Press Enter.
The following screen appears:
4. At the login prompt, provide your Username and Password.
Note: If you cannot see the login prompt click Terminal/Preferences on the
telnet session's menu bar, then select VT-100/ANSI.
Once a Telnet connection to the device is established, the SN0108 / SN0116 Main Menu comes up. See p. 47 for Telnet operation.
67
SN0108 / SN0116 User Manual
SSH

Terminal Session (Linux):

1. Open a terminal (command line) on your computer.
2. At the prompt, key in your SN0108 / SN0116 Username and the SN0108 / SN0116's IP Address in the following way:
SSH [username@IP Address]
Note: The default SSH port is 22. If that port is already being used, up to
16 additional users can log in by adding a port number (from 5100 to 5115) to the login command. For example:
SSH [username@IP Address] -P 5101
3. Press Enter
4. When you are prompted for a password, use your SN0108 / SN0116 password.
Once an SSH connection to the device is established, the SN0108 / SN0116 Main Menu comes up:
This menu is the same as the main menu that appears with Telnet sessions (see p. 47 for Telnet operation).
68
Chapter 6. Out of Band Operation

Third Party Utility (Windows):

SSH sessions can be implemented under Windows with the use of third party utility software, such as PuTTY, a free implementation of Telnet and SSH for the Win32 and Unix platforms. To make an SSH connection with PuTTY, do the following:
1. In the Host Name box, enter the Internet host name of the server you want
to connect to.
Note: The default SSH port is 22. If that port is already being used, select
an alternate port - from 5100 to 5115. This allows up to 16 additional users to log in at the same time.
2. Select SSH from the Protocol buttons.
3. Click Open (at the bottom of the dialog box)
4. After you have connected, provide your SN0108 / SN0116 username and
password at the login prompts.
Note: If you make a mistake keying in the username, the SSH protocol
doesn't allow you to try again. Y ou must close PuTTY and start over .
Once an SSH connection to the device is established, the SN0108 / SN0116 Main Menu comes up. This menu is the same as the main menu that appears with Telnet sessions (see p. 47 for Telnet operation).
69
SN0108 / SN0116 User Manual
This Page Intentionally Left Blank
70
Chapter 7

Real COM Port Management

Overview

The SN0108 / SN0116 offers Real COM Port (Virtual COM Port) support. Devices connected to this virtual port appear as if they were connected to a COM port on the local computer. Data transmission between the device and the local computer takes place over the virtual COM port to the SN0108 / SN0116.
This mode is useful with serial devices such POS terminals, Bar Code Readers, Serial printers, etc. In addition, this mode can be used with other Altusen management products, such as the PN9108 Power Over the NET™.

Driver Installation

In order to utilize Real COM port management, the Altusen virtual COM port driver must be installed on the local computer.

Windows 2000 and Higher Installation

To install the Windows 2000 and higher driver, do the following:
1. On the software CD that came with your SN0108 / SN0116 package,
locate the file: sn0108_0116_virtual COM port_ windows 2000__vxxx.exe
Note: The vxxx specified above stands for the driver’s version number . The
file on the CD will show an actual version number.
2. Double click the filename. The Setup screen appears:
71
SN0108 / SN0116 User Manual
3. Click Next to move on.
4. Click Yes to accept the License Agreement.
5. Continue through the setup screens to complete the driver installation.
Uninstalling the Driver
To uninstall the driver
1. Open the Windows Start menu.
2. Select: All Programs
Virtual Port Management Utility Uninstall
Manager.

Windows 98 Installation

To install the Windows 98 and higher driver, do the following:
1. On the software CD that came with your SN0108 / SN0116 package, locate the file: SN0116 Virtual Port for Win98 vxxx.exe.
Note: The vxxx specified above stands for the driver’s version number . The
file on the CD will show an actual version number.
2. Double click the filename. The Setup screen appears. (It looks exactly like the screenshot, above.)
3. Click Next to move on.
4. Click Yes to accept the License Agreement.
5. Continue through the setup screens to complete the driver installation.
Uninstalling the Driver
To uninstall the driver
1. Open the Windows Start menu.
2. Select: All Programs Manager.
Virtual Port Management Utility Uninstall
72
Chapter 7. Real COM Port Management

Linux Installation

Preparation
Before installing the driver file, make sure that the target you want to map is on the network; that the port on the target you want to map is in Real COM Port mode; and that your Linux IP address has been specified in the SN0108 / SN0116's Direct Access dialog box (see Direct Access, page 39).
Installing the Driver
To install the driver file, first become root, and do the following:
1. Create a temporary directory in your system. For example, to create a temp
directory under root, at the # prompt use the following command:
mkdir /root/temp
Note: Under Linux, all input is case sensitive
2. On the software CD that came with your SN0108 / SN0116 package,
locate the file AtenVPInstall_vxxx.tgz (or download it from our website), and copy it into the temp directory you just created.
Note: The vxxx specified above stands for the driver’s version number . The
file on the CD will show an actual version number.
3. At the # prompt, uncompress AtenVPInstall_vxxx.tgz with the following
command:
tar xvfz AtenVPInstall_vxxx.tgz
4. After AtenVPInstall_vxxx.tgz has been uncompressed, at the # prompt
issue the following command:
./AtenVPInstall.sh
5. Follow the on-screen instructions to install the driver.
Uninstalling the Driver
To uninstall the virtual port driver, as well as the daemon and device files, first become root, and run:
/usr/lib/AtenVPort/AtenVPUnInstall.sh
This kills the daemon, and unloads the driver module from the kernel. It modifies the rc file to eliminate self-starting of the daemon and auto-loading of the module, and removes virtual port device files(/dev/ttyaxxx).
73
SN0108 / SN0116 User Manual
Real COM Port Management – Windows
The Virtual Port Management Utility provides a convenient interface to COM port mapping. When you run the Virtual Serial Port Manager program (Start
Virtual Port Management Utility Virtual Serial Port Manager), the
following dialog box appears:

Dialog Box Layout

The Virtual Port Management Utility dialog box is laid out as fo llows: The menu and button bars allow the automatic enumeration and listing of
devices and ports.
Below the menu and button bars, there is an area to input information in
order to manually list target devices if the device doesn’t appear using the automatic enumeration method.
All target devices that were found by enumeration or manually entered are
listed in the left side panel.
All ports that were found for a selected target device are enumerated in the
central panel.
The right side panel displays the virtual COM port mappings that you have
made.
74
Chapter 7. Real COM Port Management
Menu and Toolbar
The Virtual Port Management Utility menu and toolbar have the same captions and functions. Users can either click the menu items or buttons to invoke the desired function, as shown in the table, below:
Item Action
Enum Targets This function searches and lists all SN01xx devices on the
Enum Ports This function lists the existing ports for the target device
Map After selecting a port from the Port List panel, selecting this
Unmap After selecting a port from the Mapped Ports list, selecting this
LAN. The results are shown in the Target List panel (see Target List, page 76, for details). Be aware that all devices listed in the T arget List will be deleted when the delete function is invoked. Be sure to remove any devices from the list that you don’t want to delete before invoking the delete function.
currently selected in the Target List. The results are shown in the Port List panel.
function maps the device’s COM port to a virtual COM port on the user’s computer.
function removes the mapping between the computer and the device’s COM port.
Ta rget Information
The Target Information fields allow a user to install (map) ports on an offline target device, as follows:
Field Action
Target IP Address Input the IP address of the target that you want to map COM
ports to. Base Socket Port The base socket port of the target device. Target Name The name of the target. If it is different from the target’s real
name, it will be replaced by the real one. Note that the name is
not related to the mapping or unmapping process. Only the IP
address, socket port and target type are relevant. Target Type The type of target to be mapped. Only SN01xx series devices
are valid. Add Target Creates an entry in the Target List based on the above
information. Delete Target Remove the currently selected target from the Target List.
75
SN0108 / SN0116 User Manual
Target List
The left side panel displays all the devices that were found with the Enumeration function, as well as any devices that were manually added with the Target Information fields.
Note: Double clicking an item in the list invokes the same function as
selecting Enum Ports–which displays the numbers and working modes of the selected target’s ports in the Port List column.
If a device was automatically listed as a result of the Enumeration
procedure, the icon to its left is drawn with green dots and lines to show that the target is on line and is ready to be mapped.
If a device was added to the list manually and is off line, the icon to its left
is drawn with black dots and lines. Double clicking a manually added item can get some information and display it in the Port List, but the working mode information is not accurate and we must assume that all the device’s ports are in Virtual Port mode. See Operating Mode, page 34 for details about port modes.
If the target is off line or is on line but does not respond within 2 seconds
of asking to enumerate its ports, the working mode information is not accurate and we must assume that all the device’s ports are in Virtual Port mode. See Operating Mode, page 34 for details about port modes.
76
Chapter 7. Real COM Port Management
Port List
This list displays the port information of the selected target (only one target can be selected at a time).
The left column lists the target’s port numbers, the second column shows
the COM port it is mapped to (if any), the third column shows its working mode, and the right column shows its status.
Note: The working mode refers to the setting for the port that was
specified when the port was configured. See Port Config, page 31, for details.
Double clicking a port in the Port List brings up a Port Mapping dialog
box that lets users select the number of COM ports they wish to map (i.e., virtual COM ports they wish to install). Only ports designated as Virtual Port ports can be mapped. See Port Mapping, page 78 for mapping details.
Note: The Port Mapping dialog box can also be invoked either by clicking
MapTo… on the toolbar or selecting MapTo… from the menu.
77
SN0108 / SN0116 User Manual
Mapped COM Ports
This panel displays the mapped COM ports, showing the device and port that each mapped one is derived from. The list is generated as soon as the application starts, and is dynamically updated whenever the mapped COM port configuration changes as a result of installations and removals.

Port Mapping and Unmapping

Port Mapping
To map a virtual COM port:
1. Double click your Target item in the Port List to bring up the Port Mapping dialog box:
2. Drop down the list of available COM ports and select the COM port you wish to map the Target port to.
78
Chapter 7. Real COM Port Management
3. Click OK to complete the operation.
Note: 1. If a range of ports was selected, and Map consecutively is enabled, the
COM ports are mapped to the Target ports in sequence based on the port numbers.
2. Only Virtual Mode port s are mapped. Other ports in the range are passed over.
Port Unmapping
To unmap virtual COM ports:
1. Either click Unmap… on the button bar or select Unmap… from the menu
to bring up the Port Unmapping dialog box:
2. Drop down the list of mapped COM ports and select the COM port you wish to unmap.
3. Click OK to complete the operation.
Note: For a consecutive unmapping, the COM ports are unmapped in
sequence based on the mapped COM port number.
79
SN0108 / SN0116 User Manual
Real COM Port Management – Linux

Mapping/Unmapping Virtual Ports

To map or unmap virtual ports, do the following:
1. As root, go to the /usr/lib/AtenVPort directory.
2. Issue the following command:
/AtenVPMapping
The process can run in either Interactive mode or Fast mode. With Interactive mode, users don’t specify any parameters on the command line. They make mapping/unmapping choices based on questions generated as the program runs.
With Fast mode, users specify parameters on the command line to indicate their mapping/unmapping choices – as shown in the following examples:
1. Mapping (input should all be on one line): ./AtenVPMapping map(1) PCPort(0-255) TargetIP(a.b.c.d)
T argetPort(1-48) NumberofMapping(1-48)
2. Unmapping (input should all be on one line): ./AtenVPMapping unmap(0) PCPort(0-255) NumberofUnMapping(1-48)

Virtual Port Naming Rules

All of the ATEN SN virtual ports under Linux have the prefix ttya. Mapped virtual ports can be found in the /dev dir. They all have a prefix of ttya
(ttya000, ttya001, etc.). The range is from ttya000 – ttya255.
80

Appendix

Safety Instructions

General

Read all of these instructions. Save them for future reference.Follow all warnings and instructions marked on the device.Do not place the device on any unstable surface (cart, stand, table, etc.). If
the device falls, serious damage will result.
Do not use the device near water.Do not place the device near, or over, radiators or heat registers.The device cabinet is provided with slots and openings to allow for
adequate ventilation. To ensure reliable operation, and to protect against overheating, these openings must never be blocked or covered.
The device should never be placed on a soft surface (bed, sofa, rug, etc.) as this will block its ventilation openings. Likewise, the device should not be placed in a built in enclosure unless adequate ventilation has been provided.
Never spill liquid of any kind on the device.Unplug the device from the wall outlet before cleaning. Do not use liquid
or aerosol cleaners. Use a damp cloth for cleaning.
The device should be operated from the type of power source indicated on
the marking label. If you are not sure of the type of power available, consult your dealer or local power company.
The device is designed for IT power distribution systems with 230V
phase-to-phase voltage.
The device is equipped with a 3-wire grounding type plug. This is a safety
feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not attempt to defeat the purpose of the grounding-type plug. Always follow your local/national wiring codes.
Do not allow anything to rest on the power cord or cables. Route the
power cord and cables so that they cannot be stepped on or tripped over.
If an extension cord is used with this device make sure that the total of the
ampere ratings of all products used on this cord does not exceed the extension cord ampere rating. Make sure that the total of all products plugged into the wall outlet does not exceed 15 amperes.
81
SN0108 / SN0116 User Manual
T o help protect your system from sudden, transient increases and
decreases in electrical power, use a surge suppressor, line conditioner, or uninterruptible power supply (UPS).
Position system cables and power cables carefully; Be sure that nothing
rests on any cables.
Never push objects of any kind into or through cabinet slots. They may
touch dangerous voltage points or short out parts resulting in a risk of fire or electrical shock.
Do not attempt to service the device yourself. Refer all servicing to
qualified service personnel.
If the following conditions occur, unplug the device from the wall outlet
and bring it to qualified service personnel for repair.
The power cord or plug has become damaged or frayed.Liquid has been spilled into the device.The device has been exposed to rain or water.The device has been dropped, or the cabinet has been damaged.The device exhibits a distinct change in performance, indicating a need
for service.
The device does not operate normally when the operating instructions
are followed.
Only adjust those controls that are covered in the operating instructions.
Improper adjustment of other controls may result in damage that will require extensive work by a qualified technician to repair.
Do not connect the RJ-11 connector marked “UPGRADE” to a public
telecommunication network.
82
Chapter .

DC Power

The system relies on the protective devices in the building installation for
protection against short-circuit, overcurrent, and earth (grounding) fault. Ensure that the protective devices in the building installation are properly rated to protect the system, and that they comply with national and local codes.
Ensure that there is a readily accessible disconnect device incorporated in
the building's installation wiring.
A separate protective earthing terminal is provided on this product and
shall be permanently connected to earth.
For the DC supply circuit, select a DC supply cable that is certified by UL,
AWM VW-1 Style 1015, minimum 16 AWG , minimum 105º C, minimum 300 V.
CAUTION: This equipment is designed to permit the connection of
the earthed conductor of the DC supply circuit to the earthing conductor at the equipment. If this connection is made, all of the following conditions must be met:
This equipment shall be connected directly to the DC supply system
earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing electrode conductor is connected.
This equipment shall be located in the same immediate area (such as
adjacent cabinets) as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor, and also the point of earthing of the DC system. The DC system shall not be earthed elsewhere.
The DC supply source is to be located within the same premises as this
equipment.
Switching or disconnecting devices shall not be in the earthed circuit
conductor between the DC source and the point of connection of the earthing electrode conductor.
WARNING: This unit is intended for installation in restricted access
areas. A restricted access area (server room, data center, etc.) is where access can only be gained by service personnel through the use of a special tool, lock and key, or other means of security, and is controlled by the authority responsible for the location.
83
SN0108 / SN0116 User Manual

Rack Mounting

Before working on the rack, make sure that the stabilizers are secured to
the rack, extended to the floor, and that the full weight of the rack rests on the floor. Install front and side stabilizers on a single rack or front stabilizers for joined multiple racks before working on the rack.
Always load the rack from the bottom up, and load the heaviest item in the
rack first.
Make sure that the rack is level and stable before extending a device from
the rack.
Use caution when pressing the device rail release latches and sliding a
device into or out of a rack; the slide rails can pinch your fingers.
After a device is inserted into the rack, carefully extend the rail into a
locking position, and then slide the device into the rack.
Do not overload the AC supply branch circuit that provides power to the
rack. The total rack load should not exceed 80 percent of the branch circuit rating.
Make sure that all equipment used on the rack – including power strips and
other electrical connectors – is properly grounded.
Ensure that proper airflow is provided to devices in the rack.Ensure that the operating ambient temperature of the rack environment
does not exceed the maximum ambient temperature specified for the equipment by the manufacturer
Do not step on or stand on any device when servicing other devices in a
rack.
84
Chapter .

Technical Support

Technical support is available both by email and online (with a browser over the web):

International

Email Support support@aten.com Online
Support
Telephone Support 886-2-8692-6959

North America

Email Support ATEN TECH support@aten-usa.com
Online Support
Telephone Support ATEN TECH 1-888-999-ATEN
Technical Support http://support.aten.com Troubleshooting
Documentation Software Updates
Technical Support ATEN TECH http://www.aten-usa.com/support
Troubleshooting Documentation Software Updates
http://www.aten.com
ATEN NJ sales@aten.com
ATEN NJ http://support.aten.com ATEN TECH http://www.aten-usa.com ATEN NJ http://www.aten.com
ATEN NJ 1-732-356-1703
When you contact us, please have the following information ready beforehand:
Product model number, serial number, and date of purchase.Your computer configuration, includi ng operating system, revision level,
expansion cards, and software.
Any error messages displayed at the time the error occurred.The sequence of operations that led up to the error.Any other information you feel may be of help.
85
SN0108 / SN0116 User Manual

Specifications

SN0108 / SN0116

Function SN0108 SN0116
Serial Connectors
Power Connector 1 x 3-prong AC Socket LEDs Link [LAN] 1 x Green
Switches Power 1 x Rocker
I/P Rating 100–240VAC; 50/60Hz; 1A Power Consumption 120V; 8W / 230V; 8W Environment Operating Temp.
Physical Properties
To Devices 8 x Serial Device
Jacks
To LAN 1 x RJ-45
10/100 Mbps 1 x Or ange/Green Power 1 x Blue RS-232 Port 8 x Green 16 x Green
Reset 1 x Semi-recessed pushbutton
Storage Temp. Humidity 0–80% RH
Housing Metal Weight 3.3 kg 3.4 kg Dimensions L x W x H 43.72 x 21.4 x 44 cm
16 x Serial Device
o
C
0–40
o
C
-20–60
Jacks
86

SN0108D / SN0116D

Function SN0108 SN0116
Serial Connectors
Power Connector DC Terminal LEDs Link [LAN] 1 x Green
Switches Power 1 x Rocker
I/P Rating 36–75V DC; 2A Power Consumption 8W Environment Operating Temp.
Physical Properties
To Devices 8 x Serial Device
16 x Serial Device
Jacks
To LAN 1 x RJ-45
10/100 Mbps 1 x Or ange/Green Power 1 x Blue RS-232 Port 8 x Green 16 x Green
Reset 1 x Semi-recessed pushbutton
o
C
0–40
Storage Temp.
-20–60
o
C Humidity 0–80% RH Housing Metal Weight 3.3 kg 3.4 kg Dimensions L x W x H 43.72 x 21.4 x 44 cm
Chapter .
Jacks
87
SN0108 / SN0116 User Manual

Administrator Login Failure

If you are unable to perform an Administrator login (because the Username and Password information has become corrupted, or you have forgotten it, for example), you can clear the login information with the following procedure:
1. Power off the SN0108 / SN0116 and remove its housing.
2. Short the jumper labeled J6.
3. Power on the switch.
4. When the Link and 10/100Mbps LEDs flash, power off the switch.
5. Remove the jumper cap from J6.
6. Close the housing and start the SN0108 / SN0116 back up. After you start back up, you can use the default Username and Password
(see Logging In, page 19) to log in.
88
Chapter .

IP Address Determination

If you are an administrator logging in for the first time, you need to access the SN0108 / SN0116 in order to give it an IP address that users can connect to. There are three methods to choose from. In each case, your computer must be on the same network segment as the SN0108 / SN0116.After you have connected and logged in you can give the SN0108 / SN0116 its fixed network address. SeeNetwork, page 23 for details.

Method 1:

For computers running Windows, an IP address can be assigned with the IP Installer utility:
1. Unzip the contents of IPInstaller.zip (found on the Software CD that came
with your SN0108 / SN0116 package) to a directory on your hard drive.
2. Go to the directory that you unzipped the IPInstaller program to and run
IPInstaller.exe. A dialog box similar to the one below appears
:
3. Select the SN0108 / SN0116 in the Device List.
Note: 1. If the list is empty, or your device doesn't appear, click
Enumerate to refresh the Device List.
2. If there is more than one device in the list, use the MAC address to pick the one you want. The SN0108 / SN0116's MAC address is located on its bottom panel.
89
SN0108 / SN0116 User Manual
4. Select either Obtain an IP address automatically (DHCP), or Specify an IP address. If you chose the latter, fill the IP Address, Subnet Mask, and
Gateway fields with the information appropriate to your network.
5. Click Set IP.
6. After the IP address shows up in the Device List, click Exit to end the program.

Method 2:

1. Set your computer's IP address to 192.168.0.XXX Where XXX represents any number or numbers except 10. (192.168.0.10 is
the default address of the SN0108 / SN0116.)
2. Specify the switch's default IP address (192.168.0.10) in your browser, and you will be able to connect.
3. Assign a fixed IP address for the SN0108 / SN0116 that is suitable for the network segment that it resides on.
4. After you log out, be sure to reset your computer's IP address to its original value.

Method 3:

A fixed IP address can also be assigned with the ARP command as follows:
1. Turn off the power to the SN0108 / SN0116.
2. Enter the following command:
arp -s <ip address> <SN0108 / SN0116's MAC address>
Where the IP address that you assign is one suitable for the network segment that the SN0108 / SN0116 resides on.
Note: The SN0108 / SN0116's MAC address can be found on its bottom
panel.
3. Turn the power to the SN0108 / SN0116 back on.
90