Altronix ALTV1224DCCB220, ALTV1224DC1CB220, ALTV1224DC2CB220, ALTV1224DCCB, ALTV1224DC1 Installation Manual

...
Page 1
ALTV1224DC220 Series
CCTV Power Supplies
Installation Guide
Models Include:
• ALTV1224DC220 • ALTV1224DCCB220
- 12VDC or 24VDC @ 4A. - 12VDC or 24VDC @ 4A.
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
- 12VDC or 24VDC @ 4A. - 12VDC or 24VDC @ 4A.
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
- 12VDC or 24VDC @ 6A. - 12VDC or 24VDC @ 6A.
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
Rev. 022505
Page 2
Overview:
D1
INPUT
R1
LED
Used on PTC Models
(example: ALTV1224DCCB220)
220VAC
power mains
Divider
ALTV1224DC220 Series DC CCTV power supplies are designed to power CCTV Cameras and accessories. Units provide 12VDC or 24VDC distributed via eight (8) or sixteen (16) fused or PTC protected outputs with a total of 4A or 6A total continuous supply current.
Eight (8) or Sixteen (16) Output ALTV1224DC Reference Chart:
Altronix Model Number
ALTV1224DC220 ALTV1224DCCB220 ALTV1224DC1220 ALTV1224DC1CB220 ALTV1224DC2220 ALTV1224DC2CB220
Output
Voltage
12VDC
or
24VDC
Total
Output Current (Power)
4A
6A 16
Number
of
Outputs
8
16
PTC
Protected
Outputs
-----
P
-----
P
-----
P
Fuse
Protected
Outputs
P
----- 2.5A
P
----- 2.5A
P
----- 2.5A
Output
Current
(max per
output)
3.5A
3.5A
3.5A
220VAC
50/60Hz
Input
Current
0.9A
1.5A
Input:
• Input 220VAC (working range 198VAC-256VAC), 50/60 Hz.
Output:
• Eight (8) or sixteen (16) fuse or PTC protected outputs.
• 12VDC or 24VDC.
• Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
• Filtered and electronically regulated outputs.
Specifications:
Features:
• AC input and DC output LED indicators.
• Power ON/OFF switch.
• Unit maintains camera synchronization.
• Ease of installation saves time and eliminates costly labor.
Enclosure Dimensions (H x W x D approx.):
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm).
Installation Instructions:
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws; level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install two fasteners. Place the enclosure’s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 6). Secure enclosure to earth ground.
2. Slide switch to OFF position (Fig. 1, pg. 3, Fig. 2, pg. 4 or Fig. 3, pg. 5).
3. Set the unit to desired DC output voltage range by setting switch (SW1) on the power supply board to the appropriate position. Use trimpot to adjust voltage if necessary (Fig. 1, pg. 3, Fig. 2, pg. 4 or Fig. 3, pg. 5).
4. Connect AC circuit (220VAC, 50/60Hz) as follows: Green branch wire connects to earth (safety) ground lug . Line and Neutral to the connector on power supply board marked [L, N] respectively (Fig. 1, pg. 3, Fig. 2, pg. 4 or Fig. 3, pg. 5).
5. Measure output voltage before connecting devices. This helps avoiding potential damage.
6. Connect each DC device to the output terminals 1 through 8 (Fig. 1, pg. 3) or terminals 1 through 16 (Fig. 2, pg. 4 or Fig. 3, pg. 5). Note: Be careful to observe camera polarity.
7. When batteries are being used, the DC output voltage must be adjusted by turning the trim pot VR1 (Fig. 1, pg. 3, Fig. 2, pg. 4 or Fig. 3, pg. 5) clockwise to increase the output voltage to 13.7VDC for 12VDC operation and 27.1VDC for 24VDC operation. Connect battery to theterminals marked [-- BAT + ] (battery leads included) (Fig. 1, pg. 3, Fig. 2, pg. 4 or Fig. 3, pg. 5). Use two (2) 12VDC batteries connected in series for 24VDC operation.
8. Slide switch to ON position (Fig. 1, pg. 3, Fig. 2, pg. 4 or Fig. 3, pg. 5).
9. Green LED on the PD8/PD8CB or PD16W/PD16WCB board will illuminate when power is present.
10. Upon completion of the wiring, secure enclosure door with screws (supplied).
WARNING: To reduce the risk of fire or electric shock do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes.
- 2 - ALTV1224DC220 Series
Page 3
ALTV1224DC/CB Terminal Identification:
CAUTION: De-energize unit prior to servicing. For continued protection against
OLS127220 - Power Supply
Terminal Legend Function/Description
L, N 220VAC power mains connection. – DC + 12VDC or 24VDC @ 4A total continuous output. – BAT + Stand-by battery connections. Maximum charge rate 0.5A.
PD8/PD8CB - Power Distribution Module
Terminal Legend Function/Description
1P - 8P Positive DC power outputs. 1N - 8N Negative DC power outputs.
Fig. 1
fire hazard replace fuse with the same type and rating. Do not expose unit to rain or moisture.
Divider
LED
Door
Wire Strap
(from
Enclosure
to Door)
Ground
Lug
220VAC
power mains
OFF - 24V
ON - 12V
1 2 3 4 5 6 7 8
OFF ON
ON
ON
OFF - 24V ON - 12V
Switch disables power mains line voltage input.
If stand-by battery (batteries) are connected the DC output remains on.
SW1 24VDC output - OFF 12VDC output - ON
INPUT
D1
R1
FUSED POWER OUTPUTS
COMMON POWER OUTPUTS
N
P
Used on PTC Models
(example: ALTV1224DCCB220)
Trimpot Adjusts output voltage on power supply
ALTV1224DC220 Series - 3 -
Page 4
ALTV1224DC1/CB Terminal Identification:
OLS127220 - Power Supply
Terminal Legend Function/Description
L, N 220VAC power mains connection. – DC + 12VDC or 24VDC @ 4A total continuous output. – BAT + Stand-by battery connections. Maximum charge rate 0.5A.
PD16W/PD16WCB - Power Distribution Module
Terminal Legend Function/Description
1P - 16P Positive DC power outputs. 1N - 16N Negative DC power outputs.
Fig. 2
CAUTION: De-energize unit prior to servicing. For continued protection against fire hazard replace fuse with the same type and rating. Do not expose unit to rain or moisture.
Door
Wire Strap
(from
Enclosure
to Door)
Ground
Lug
220VAC
power mains
ON - 12V
OFF - 24V
ON
Divider
12345678
OFF ON
ON
OFF - 24V ON - 12V
9 10 11 12 13 14 15 16
common
outputs protected
outputs
For continuous protection against risk of fire
replace fuses with same type and rating.
3.5A 250V
Switch disables power mains line voltage input.
If stand-by battery (batteries) are connected the DC output remains on.
SW1 24VDC output - OFF 12VDC output - ON
Trimpot Adjusts output voltage on power supply
N
P
NP
NPS
XFMR Input
Used on PTC Models
(example: ALTV1224DC1CB220)
12345678
common
outputs
protected
outputs
9 10 11 12 13 14 15 16
N
P
NP
NPS
XFMR Input
- 4 - ALTV1224DC220 Series
Page 5
ALTV1224DC2/CB Terminal Identification:
OLS187220 - Power Supply
Terminal Legend Function/Description
L, N 220VAC power mains connection. – DC + 12VDC or 24VDC @ 6A total continuous output. – BAT + Stand-by battery connections. Maximum charge rate 0.5A.
PD16W/PD16WCB - Power Distribution Module
Terminal Legend Function/Description
1P - 16P Positive DC power outputs. 1N - 16N Negative DC power outputs.
Fig. 3
CAUTION: De-energize unit prior to servicing. For continued protection against fire hazard replace fuse with the same type and rating. Do not expose unit to rain or moisture.
Door
Wire Strap
Enclosure
to Door)
(from
Ground
Lug
OFF - 24V
ON - 12V
Divider
12345678
3.5A 250V
ON
OFF ON
ON
OFF - 24V ON - 12V
Switch disables power mains line voltage input.
If stand-by battery (batteries) are connected the DC output remains on.
SW1 24VDC output - OFF 12VDC output - ON
Trimpot Adjusts output voltage on power supply
9 10 11 12 13 14 15 16
common
outputs
protected
outputs
For continuous protection against risk of fire
replace fuses with same type and rating.
N
P
NP
NPS
XFMR Input
ON OFF
5A 250V
LGN
220VAC
power mains
AC
DC
--- BAT + --- DC +
Used on PTC Models
(example: ALTV1224DC2CB220)
12345678
common
outputs
protected
outputs
9 10 11 12 13 14 15 16
N
P
NP
NPS
XFMR Input
ALTV1224DC220 Series - 5 -
Page 6
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
(
)
(
)
(
)
presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel.
Enclosure Dimensions:
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm)
1.40”
(36mm)
1.20”
(31mm)
(36mm)
0.75”
(19mm)
1.40”
4.85”
(123mm)
12.5”
(318mm)
11.0”
(279mm)
4.85”
(123mm)
1.40”
(36mm)
(19mm)
0.75”
1.20”
(31mm)
0.9375” (24mm)
3.25”
(83mm)
1.20”
(31mm)
1.40”
(36mm)
5.10”
(130mm)
5.10”
(130mm)
3.25”
(83mm)
13.0”
(330mm)
1.0”
(25mm)
0.9375” (24mm)
1.0”
(25mm)
3.25”
(83mm)
3.25”
(83mm)
5.10”
(130mm)
6.5625”
(167mm)
1.0”
25mm
10.5”
267mm
1.0”
25mm
- 6 - ALTV1224DC220 Series
Page 7
Notes:
ALTV1224DC220 Series - 7 -
Page 8
Notes:
Altronix is not responsible for any typographical errors.