AL400ULX Series
Power Supply/Charger
Installation Guide
Models Include:
AL400ULX
- Single Output.
AL400ULPD4
- Four (4) Fuse Protected Outputs.
AL400ULPD8
- Eight (8) Fuse Protected Outputs.
AL400ULXPD16
- Sixteen (16) Fuse Protected Outputs.
For a red enclosure add an “R” suffix to the part #, e.g. AL400ULPD8R
Rev. 013119
AL400ULPD4CB
- Four (4) PTC Protected Outputs.
AL400ULPD8CB
- Eight (8) PTC Protected Outputs.
AL400ULXPD16CB
- Sixteen (16) PTC Protected Outputs.
More than just power.
TM
Altronix AL400ULX is a power supply that converts a 115VAC, 60Hz input to a 12VDC or 24VDC regulating
output (see specifications below).
The AL400ULX is a base power supply unit for the UL Listed multi-output power supply/charger series:
AL400ULPD4, AL400ULPD4CB, AL400ULPD8, AL400ULPD8CB, AL400ULXPD16, AL400ULXPD16CB
(Refer to AL400ULX Series Power Supply Configuration Reference Chart below).
AL400ULX Series Power Supply Configuration Reference Chart:
Overview:
Altronix
Accessory Power
Distribution
Module(s)
Number of Outputs
Fused Outputs
PTC Outputs (auto-resettable)
12VDC Total
Output Current (A)
24VDC Total
Output Current (A)
Output Rating (A) per Output
Power Supply
Input Fuse Rating
Power Supply
Model Number
AL400ULX
AL400ULXX
AL400ULXR
AL400ULPD4
AL400ULPD4CB
AL400ULPD8
AL400ULPD8CB
AL400ULXPD16
AL400ULXPD16CB
– 1 – – 4 3 2.5
PD4UL
–
P
4
PD4ULCB –
PD8UL
PD8ULCB –
Two (2)
PD8UL
P
8
P
P
– 3.5
4 3
P
– 3.5
16
Two (2)
PD8ULCB
–
P
5A/
250V
3.5
5A/
250V
2.5
5A/
250V
2.5
5A/
250V
2.5
Output Fuse Rating
15A/
32V
15A/
32V
15A/
32V
15A/
32V
*Access Control Performance Levels:
Destructive Attack - I; Endurance - IV; Line Security - I; Stand-by Power - IV.
NYC
Dept. of
Buildings
Agency
Listings
Factory
Mutual
Approved
UL Listings and
UL File # S4707
140 58th St. Brooklyn, NY
UL Listed for Access
California
State Fire
Marshal
UL Listed for Power
Supplies for Use
with Burglar-Alarms
UL Listed Hospital
Signaling and Nurse
Call Equipment.
UL Listed for Power
Supplies for Fire
Protective Signaling
“Signal Equipment”
CSA Standard C22.2
No.205-M1983
File Numbers
UL 294*
Control
System Units.
––––––––
UL 603
Systems.
––––––––
UL 1069
––––––––
UL 1481
Systems
––––––––
Evaluated to
AL400ULPD4(CB) and AL400ULPD8(CB) are available in larger enclosure.
Add “X” to the model number (e.g. AL400ULXPD4/CB).
- 2 - AL400ULX Series
Specifications:
Input:
• Input 115VAC, 60Hz, 3.5A.
Output:
• Class 2 Rated power-limited output(s).
• 12VDC or 24VDC selectable output(s).
Burglar Alarm Aplications (UL 603):
12VDC = 10VDC-13.2VDC.
24VDC = 20VDC-26.4VDC.
• 4A total supply current at 12VDC or
3A total supply current at 24VDC.
• Filtered and electronically regulated output(s).
• Short circuit and thermal overload protection.
Supervision:
• AC fail supervision (form “C” contacts).
• Low battery and battery presence supervision
(form “C” contacts).
Power Supply Output Specifications:
Output Switch Position
12VDC SW1 - ON
24VDC SW1 - OFF
Stand-by Specifications (total current shown):
Output
12VDC / 40AH Battery
24VDC / 12AH Battery –
24VDC / 40AH Battery
4 hr. of Stand-by and
5 Minutes of Alarm
Stand-by = 4.0A
Alarm = 4.0A
Stand-by = 3.0A
Alarm = 3.0A
Battery Backup:
• Built-in charger for sealed lead acid or
gel type batteries.
• Automatic switch over to stand-by battery when
AC fails.
• Maximum charge current 0.7A.
• Zero voltage drop when switched over to
battery backup.
LED Indicators:
• AC input, DC output and Battery LED indicators.
Additional Features:
• Power supply, enclosure, cam lock and battery leads.
• All models are available in red enclosure
(add an “R” suffix to the part #, e.g. AL400ULPD8R).
ON
OFF - 24V
24 hr. of Stand-by and
5 Minutes of Alarm
Stand-by = 1.0A
Alarm = 4.0A
Stand-by = 200mA
Alarm = 3.0A
Stand-by = 1.0A
Alarm = 3.0A
60 hr. of Stand-by and
5 Minutes of Alarm
Stand-by = 300mA
Alarm = 4.0A
–
Stand-by = 300mA
Alarm = 3.0A
AL400ULX Series - 3 -
Fig. 1
Power
Distribution
Module(s)
+ DC ---
NC C NO NC C NO
+ BAT ---
AC DC Bat
Risk of Fire,
Replace Fuses
As Marked
AC Fail
Bat Fail
J1
SW1
5A 250V
15A 250V
AC Delay
15
L G N
Door
CAUTION: De-energize unit prior to servicing. For continued protection against risk
of electric shock and fire hazard replace fuse with the same type and rating.
Do not expose to rain or moisture.
Green
Lead
Battery connection (non power limited)
Switch Position:
24VDC = SW1 OFF
12VDC = SW1 ON
Wire
Strap
(from
Enclosure
to Door)
115VAC
power mains
non-power
limited
Battery & AC
Supervision
Circuit
(power limited)
-
Divider
power-limited
For 12VDC Operation
use hook-up in the
inset on the right
CAUTION: When power supply board is set for 12VDC use only one (1) 12VDC stand-by battery.
Keep power limited wiring separate from non-power limited. Use minimum 0.25" spacing.
12VDC Rechargeable Battery
(optional)
12VDC Rechargeable Battery
(optional)
SW1
NC C NO NC C NO AC Fail
Bat Fail
J1
AC Delay
OFF - 24V
ON - 12V
ON
1
OFF - 24V
ON - 12V
ON
1
Battery & AC
Supervision Circuit
(power-limited)
Fig. 1a
Fig. 1b
Fig. 1c
- 4 - AL400ULX Series