#6009ML • 7/2002
PRINTED IN U. S .A .
VENTLESS HOOD
Model: VH
ML-5
VHML-10
OPERATION and CARE MANUAL
COOK/HOLD/SERVE SYSTEMS
W164 N9221 Water Street •P.O. Box 450 •Menomonee Falls, Wisconsin 53052-0450 U.S.A.
PHONE: 262.251.3800 FAX: 262.251.7067 • 800.329.8744 U.S.A. ONLY WEBSITE:
800.558.8744 U.S.A./CANADA 262.251.1907 INTERNATIONAL www.alto-shaam.com
VHML-10
pictured on Combitherm
Model 10•18
ML electric
VENTLESS HOOD
UNPACKING and SET-UP
The Alto-Shaam Ventless Hood has been thoroughly
tested and inspected to insure only the highest quality unit is
provided. When you receive your hood, check for any
possible shipping damage and report it at once to the
delivering carrier.
Save all the information and instructions packed inside
the carton. Complete and return the warranty card to the
factory as soon as possible to assure prompt service in the
event of a warranty parts and labor claim.
NOTE
: All claims for warranty must include the full model number
and serial number of the unit.
OPERATION
The Ventless Hood is factory installed directly on the
top of the Alto-Shaam
® Combitherm® oven. The hood is
designed to vent clean air back into the kitchen, filtering
vapors and grease. A high-power fan draws steam and
fumes into the hood intake and out the top surface exhaust
vent. Fumes and vapors are circulated through filters
draining the condensation through a drain at the rear of the
hood. An activated charcoal filter cleans the air before
venting it out the top of the hood.
Turn the ventless hood ON before operation of the
Combitherm oven. There are a number of safety features
incorporated into the operation of the hood which are
directly related to the interaction of hood function and the
operation of the combination oven/steamer.
VENTLESS HOOD INTERLOCK SWITCHES
— CHARCOAL FILTER SWITCH, GREASE FILTER SWITCH:
Prevents hood and oven operation if any filter is not in
place or is improperly installed.
— FAN PRESSURE SWITCH: Prevents Combitherm oven
operation if hood fan is not operating or if the filters are
more than 25% blocked.
TIMED LATCHING MECHANISM
— In order to evacuate steam and grease-laden air from
the oven interior, this mechanism briefly prevents the
operator from fully opening the oven door. The
mechanism automatically disengages at the end of a
pre-set time allowing full door extension.
RESET SWITCH
— The Reset has to be used if the Combitherm oven is turned on
before the hood or if the hood was opened. It resets the
pressure switch circuit and provides power to the
Combitherm control circuit. This switch must also be used to
reset hood controls after any problem with the filters, or the
improper latching of the ventless hood door. See illustrations
on following pages of this manual.
1. An identification tag is permanently mounted on the back of
the ventless hood.
2. The interconnenct cord from the ventless hood to the
Combitherm oven provides full power connection.
See illustrations on following pages of this manual.
®
MODEL
VHML-5 VHML-10
Replacement Filters
Grease FI-24113 FI-23062
Charcoal FI-24114 FI-24102
Charcoal
Filter Frame -- 1426
Fan Motor FA-3716 FA-33252
Fan Capacitor FA-33440 FA-33146
Fuse FU-3775 FU-3775
Fuseholder FU-3772 FU-3772
Hinge, Door HG-25514 HG-25514
Hood Control/Timer BA-33827 BA-33827
Latch, Door LT-3738 LT-3738
Power Supply RL-33828 BA-33828
Relay, 240V RL-33831 RL-33831
Relay, Power RL-33493 RL-33493
Solenoid SE-33615 SE-33615
Switch, Power SW-33101 SW-33101
Switch, Pressure SW-33538 SW-33538
Switch, Reset SW-33495 SW-33495
Switch, Safety, Filters SW-33148 SW-33148
#6009ML Operation & Care - Pg. 1
ELECTRICAL
SERVICE PARTS
EXAMPLE
SERIAL NUMBER AND WARRANTY CODE
IDENTIFICATION MODEL NUMBER
MODEL
SERIAL NO. WATTS
VOLTS
MAXIMUM RATED VOLTAGE MAXIMUM RATED FREQUENCY
xxx-xx
xxxx-xx xxxx
AC
1 PH
ALTO-SHAAM INC. MILW. WI. PAT. NO. 3521030
MAXIMUM RATED
WATTAGE
xx
HZxxx
#6009ML Operation & Care - Pg. 2
VHML-5 Ventless Hood
Grease Filter
Charcoal Filter
Timed Oven
Latching Mechanism
Opening Mechanism
Using a coin or screwdriver, turn
to open; reverse procedure to
close and latch.
Hood and oven will not operate
unless this is closed properly.