Alpha IR315F Specsheet

Product Specification Sheet A PS106 - Rev. 07/2013
IR315F Duty/Staff Station (NC300II/HC345 Series)
42 Central Drive • Farmingdale • NY • 11735-1202 • Phone: (631) 777-5500 • Fax: (631) 777-5599
TOLL-FREE: (800) 666-4800 • Web: AlphaCommunications.com • Email: info@alphacommunications.com
Copyright© 1998-201 4 Alpha Communications® - All Rights Reserved.
Due to co ntinuous pro duct improvement, all colo rs, sizes, materials, finishes and specification s are subject to ch ange without n otice.
IR315F
Architects' And Engineers'
Specifications
Duty Stat ion(s) shall be Alpha Communications® / TekTone model IR315F, or approved equal. Model IR315F shall include LSI/Microprocessor tec hnology, combination yellow c all placed indicator and c all button, combination red in use indicator and reset butt on, and red emergency/code call indicator. Audible and visual signaling of normal and emergency c alls shall be provided. Three distinctive tone volume levels shall be available and shall be field-programmable at the st ation. It shall be possible via user programming, to select the call priorities the duty st ation will annunciate. The st ation shall utilize a 2.50" x 2.50" speaker/microphone for accurate voice reproduction. All IR315F components shall be mounted on an att ract ive flame retardant ABS plastic faceplate, in fog white c olor. Connections shall be pug-in type.
The IR315F shall be U.L. 1069 listed to the latest 4th Edition St andards. Contractor shall observe all local and national electrical and building codes.
IR315F Duty Station
The IR315F duty station provides reliable two way, hands free communication between the nurse master st ation and utility and examination rooms, kitc hen, or any locat ion where a nurse may perform a funct ion out of hearing or sight range of t he master stat ion.
Calls are placed from the duty stat ion to the master station by use of a momentary push button. Calls answered at the master station c ause the red in use indicator on the duty st ation to light and the nurse may then carry on a conversation from the remot e loc ation.
A call originating from a patient stat ion is indicated bot h audibly and visually at the duty station to which it is assigned. Normal calls are indicated by a st eady illumination of the yellow call-placed indicator and a slowly repeating tone. Emergency/bath calls c ause alternate flashing of the yellow call-placed and red emergency indicators and a rapidly repeating t one. Code calls function the same as emergency calls, but at twice t he pulse rate. Dome light indication is also provided. All c alls initiated from stations ot her than t he duty stat ion can only be reset at t he master stat ion or point of origin.
Features
U.L. 1069 Listed, 4th Edition Standards Fully supervised LSI/Microproc essor design Solid-stat e multiplex circuitry Simplified multiplex wiring using plug-in type connec tors Attractive flame retardant ABS plastic faceplate Improved t actile feel in the Reset and Call button Select ive annunciation of call priority
Specifications
Dimensions:
Height: 4.50" (119mm) Width: 6.38" (162mm) Depth: 2.75" (70mm) Projects: 0.50" (12.7mm) above mounting surface
Construction: Attractive, flame retardant ABS plastic
Finish: Light texture, fog white c olor.
Connections: Plug-in type
Housing:
Steel City #H3BD with Steel City #3GC plaster ring, or Alpha Communications® Part #IH353 box with IH352 ring, or EXACT EQUAL. Horizontal mount.
Wiring: Multiplex (using #WM300B or WM300BP cable)
Speaker: 2.50" x 2.50"