Alpha IN024A Specsheet

Product Specification Sheet APS651 - Rev. 12/2013
IN024A 24 Input Serial Encoder BoardIN024A 24 Input Serial Encoder Board
Alpha CommunicationsAlpha Communications
42 Central Drive • Farmingdale • NY • 11735-1202 • Phone: (631) 777-5500 • Fax: (631) 777-559942 Central Drive • Farmingdale • NY • 11735-1202 • Phone: (631) 777-5500 • Fax: (631) 777-5599
TOLL-FREE: (800) 666-4800 • Web: AlphaCommunications.com • Email: info@alphacommunications.comTOLL-FREE: (800) 666-4800 • Web: AlphaCommunications.com • Email: info@alphacommunications.com
Copyright © 1998-2 016 Alpha Communication s® - All Righ ts Reserved.
Architects' And Engineers' SpecificationsArchitects' And Engineers' Specifications
The 24-input RS232 Decoder Board(s) shall be Alpha Communications® IN024A or equivalent. T he IN024A shall be activated by c apturing the voltage(s) generated by cont act closures or voltages generated, and sending the proper RS232 data to a PC which is running VisitorVerifier™ or AlphaEntry™ (or other) Alpha Communications® software.
The cont ract or shall also furnish and install the required KE-
PWR5/2A (5VDC) power supply, MTA100-13-12 wiring harness
cable and RS232 cable to c onnec t the IN024A to t he PC's serial input port (or USB port with the proper adapter).
All wiring to relay shall be low-voltage Class II wiring, installed as per all federal, stat e, and local electrical and building codes.
IN024A 24 Input Serial Encoder BoardIN024A 24 Input Serial Encoder Board
The Alpha Communicat ions® IN024A 24-input Decoder Boards are used for a variety of applications. T he primary use is for c apturing up to 24 voltage (or dry c ontact ) inputs from an entry interc om or call st ation (or up to 144 when used in a matrix c onfiguration with some additional components), and sending the proper RS232 data to a PC which is running VisitorVerifier™ or AlphaEntry™ (or other) Alpha Communications® software.
The IN024A boards are designed to easily surface mount right onto the finished wall by using the mounting holes provided for sc rew mounting, along with the provided plastic st and-offs.
Connect ions are positive sc rew t erminal and plug-in type.
FeaturesFeatures
Easily Installs Right on Finished Wall Surfac e Operates on Safe Low- Voltage Class II Wiring RS-232 port to accept serial data or send serial data based on inputs. Convenient Sc rew Terminal and Plug-in Connect ions Program up to 12 x 12 matrix, based on application. Pins not used as Rows or Columns can be used as individual inputs (requires additional components for grater than 24 inputs). DB9 female connect or for RS232 hookup No special drivers required
SpecificationsSpecifications
Dimensions:
4.00"W (102mm) x 3.00"H (77mm) x .75"D (20mm).
Connections:
Screw Terminal and Plug-in Connect ors (requires MT A100-13-12 cable)
Power Required:
5VDC, provided by the model KE-
PWR5/2A power supply
Operating Temp.: 0°C - 70°C