All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis K.K.
Microsoft is a registered trademark of Microsoft Corporation, Netscape Navigator is a registered trademark of Netscape
Communications Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks
or registered trademarks of their respective owners.
Allied Telesis K.K. reserves the right to make changes in specifications and other information contained in this document without prior
written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesis K.K. be liable for
any incidental, special, indirect , or co ns equen tial d amages what soever, including but not limited to l ost p rof its, ar ising out of or rel at ed
to this manual or the information contained herein, even if Allied Telesis K.K. has been advised of, known, or should have known, the
possibility of such damages.
Page 3
Electrical Safety and Emission
Statement
Standards: This product meets the following standards.
Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate
Important: Appendix C contains translated safety statem ents for installing this equipment. When you see the , go to Appendix C
for the translated safety statement in your language.
Wichtig: Anhang C enthält übersetzte Sicherheitshinweise für die Installation dieses Geräts. Wenn Sie
Anhang C den übers etzten Sicherheitshinweis in Ihrer Sprache nach.
Vigtigt: Tillæg C indeholder oversatte sikkerhedsadvarsler, der vedrøre r installation af dette udstyr. Når De ser symbolet
slå op i tillæg C og finde de oversatte sikkerhedsadvarsler i Deres eget sprog.
Belangrijk: Appe ndix C bevat vertaalde veilig he idsopmerkingen voor het instal le re n van deze apparatuur. Wann ee r u de
raadpleeg Appendix C voor ve rtaalde veiligheidsinstructies in uw taal .
Important: L'annexe C contient les instructions de sécurité relatives à l'installation de cet équipement. Lorsque vous voyez le symbole
, reportez-vous à l'annexe C pour consulter la traduction de ce s instructions dans votre langue.
Tärkeää: Liite C sisältää tämän laitteen asentamiseen liittyvät käännetyt turvaohjeet. Kun näet
turvaohjet ta liitteestä C.
Importante: l’Appendice C contiene avvisi di sicurezza tradotti per l’installazione di questa apparecchiatura. Il simbolo
consultare l’Appendice C per l’avviso di sicurezza nella pro pria lingua.
Viktig: Tillegg C inneholder oversatt sikkerhetsinformasjon for installering av dette utstyret. Når du ser
å finne den oversatte sikkerhetsinformasjonen på ønsket språ k.
Importante: O Anexo C contém advertências de segurança traduzidas para instalar este equipamento. Quando vir o símbolo
advertência de segurança traduzida no seu idioma no Ane xo C.
Importante: El Apéndice C contiene mensajes de seguridad tra ducidos para la instalación de este equipo. Cuando vea el símbolo
vaya al Apéndice C para ver el mensaje de seguridad traducido a su idioma.
Obs! Bilaga C innehåller översatta säkerhetsmeddelanden avseende installationen av denna utrustning. När du ser
Bilaga C för att läsa det översatta säkerhetsmeddelandet på ditt språk.
How This Guide is Organized ...............................................................................................................................................6
Summary of Features ............................................................................................................................................................9
Location of Components .....................................................................................................................................................11
Hardware Features ...............................................................................................................................................................12
VDSL Line Port........................................................................................................................................................... 12
PSTN Port .................................................................................................................................................................... 13
Status LEDs.................................................................................................................................................................. 15
DC Power Supply Input Port ....................................................................................................................................... 16
External AC/DC Power Adapter.................................................................................................................................. 16
Software Features ................................................................................................................................................................17
Selecting a Site for the Network Extender ..........................................................................................................................21
Cables Not Included ............................................................................................................................................................22
Unpacking the Network Extender .......................................................................................................................................23
Installing the AT-MC601 Subscriber Unit ..........................................................................................................................24
Using the Subscriber Unit on a Desktop...................................................................................................................... 24
Wall-Mounting the Subscriber Unit.............................................. ..... .......................................................................... 24
4
Page 5
Contents
Cabling the Subscriber Unit......................................................................................................................................... 26
Powering On the Subscriber Unit................................................................................................................................ 27
Installing the AT-MC602 Provider Unit .............................................................................................................................28
Using the Provider Unit on a Desktop......................................................................................................................... 28
Wall-Mounting the Provider Unit................................................................................................................................ 29
Grounding the Provider Unit....................................................................................................................................... 30
Rack-Mounting the Provider Unit. ...... ....................................... ................................................................................. 31
Cabling the Provider Unit............................................................................................................................................ 32
Powering On the Provider Unit................................................................................................................................... 33
Opening the Configuration Software........................................................................................................................... 37
Configuring the Provider Unit ............................................................................................................................................38
Configuring the Subscriber Unit ................................ .........................................................................................................45
Power Specifications .................................................. ...... ...... ....................................... ..... .................................................52
Safety and Electromagnetic Compatibility Certifications ........................... ........................................ .... ...........................53
Appendix C
Translated Electrical Safety and Emission Information ...............................................................................................54
5
Page 6
Preface
This guide contains instructions on how to install and configure the
AT-MC601 and AT-MC602 Extended Ethernet units.
How This Guide is Organized
This manual contains the following chapters and appendices:
Chapter 1, Product Description, describes the features and components
of the network extenders.
Chapter 2, Installation, contains installation instructions for each unit.
Chapter 3, Configuration, explains how to use the configuration
software. The AT-S57 software is used to configure the network extenders.
Chapter 4, Troubleshooting, provides information on how to resolve
common problems that might occur with the network extenders.
Appendix A, Default Settings, lists the default software settings.
Appendix B, Technical Specifications, lists the technical specifications
for the network extenders.
Appendix C, Translated Electrical Safety and Emission Information,
contains multi-language translations of the warnings and cautions in the
manual.
6
Page 7
Preface
Document Conventions
This document uses the following conventions:
Note
Notes provide additional information.
Warning
Warnings inform you that performing or omitting a specific action may
result in bodily injury.
Caution
Cautions inform you that performing or omitting a sp ecific action may
result in equipment damage or loss of data.
7
Page 8
AT-MC601, AT-MC602 Installation and User’s Guide
Contacting Allied Telesyn Technical Support
This section provides Allied Telesyn contact information for technical
support as well as sales or corporate information.
Online SupportYou can request technical support online by accessing the Allied Telesyn
Knowledge Base from the following web site:
http://kb.alliedtelesyn.com. You can use the Knowledge Base to submit
questions to our technical support staff and review answers to previously
asked questions.
E-mail and
Telephone
Support
Returning
Products
For Sales or
Corporate
Information
Obtaining
Management
Software Updates
For Technical Support via E-mail or telephone, refer to the Support &
Services section of the Allied Telesyn web site:
http://www.alliedtelesyn.com.
Products for return or repair must first be assigned a Return Materials
Authorization (RMA) number. A product sent to Allied Telesyn without a
RMA number will be returned to the sender at the sender’s expense.
To obtain a RMA number, contact Allied Telesyn’s Technical Support at
our web site: http://www.alliedtelesyn.com
You can contact Allied Telesyn for sales or corporate information at our
web site: http://www.alliedtelesyn.com. To find the contact information for
your country, select Contact Us then Worldwide Contacts.
New releases of management software for our managed products can be
downloaded from either of the following Internet sites:
•Allied Telesyn web site: http://www.alliedtelesyn.com
•Allied Telesyn FTP server: ftp://ftp.alliedtelesyn.com
If you would prefer to download new software from the Allied Telesyn
FTP server from your workstation’s command prompt, you will need FTP
client software and you will be asked to log in to the server. Enter
‘anonymous’ as the user name and your email address for the password.
8
Page 9
Chapter 1
Product Description
The AT-MC601, AT-MC602 Extended Ethernet products are designed to
transmit data at very high speeds over unshielded pairs of copper wires
using VDSL technology on your existing telephone line.
Summary of Features
❑ VDSL (Very high-bit-rate Digital Subscriber) Line port
❑ PSTN (Public Switched Telephone Network) port
❑ 10/100 Mbps Ethernet port with an RJ-45 connector
❑ Auto MDI/MDI-X
❑ Auto-Negotiation for speed and duplex mode (IEEE 803.3u-
compliant)
❑ Status LEDs
❑ Management port
❑ AT-S57 configuration software
❑ 12V DC external power supply input port
9
Page 10
Overview
AT-MC601, AT-MC602 Installation and User’s Guide
These devices can be used in multi-dwelling units (MDU), multi-tenant
buildings (MTU), and in the hospitality industry, such as airports, hotels,
and convention centers.
These units are sold in pairs with the AT-MC601 functioning as the
subscriber and the AT-MC602 functioning as the provider. In an MDU,
such as a university dormitory, the subscriber unit would be installed in
each room and connected to a provider unit through the telephone outlet.
Each AT-MC602 or provider unit would be located in the building wiring
closet.
The AT-MC601 Extended Ethernet unit can be used as a desktop or
wallmount device while the AT-MC602 can be either installed in an
AT-MCR12 chassis, used as a desktop device, or mounted onto the wall,
provided that the chassis is connected to an appropriate ground rod. Refer
to ”Installing the AT-MC602 Provider Unit” on page 28" for installation
details. These units are easy to install. They can be configured and
managed through the MGMT port using the software provided on the
installation CD.
When both the AT-MC601 Subscriber and the AT-MC602 Provider have
been installed, the network extender system topology shown in Figure 1 is
complete.
Computer’s
Ethernet Port
AT-MC601
Subscriber
Unit
AT-MC602
Provider
Unit
Internet
Service
Provider
10BaseT/
100BaseTX
LINK
ACT
PWR
AT-MC601
10BaseT/
100BaseTX
LINK
ACT
PWR
AT-MC602
VDSL EXTENDED ETHERNET
MGMT
MGMT
VDSL EXTENDED ETHERNET
Laptop
Telephone
LINE
PSTN
VDSL Line through
wall/interior phone line
LINE
PSTN
ERR
LINK
ERR
LINK
Telco
PBX
Line
Figure 1 Network Extender System Topology
10
Page 11
Product Description
Location of Components
Figure 2 illustrates the front panels of the AT-MC601 and AT-MC602
network extenders.
AT-MC601
Ethernet
Status
LEDs
10BaseT/
100BaseTX
LINK
ACT
PWR
AT-MC601
Ethernet Port
MGMT
VDSL EXTENDED ETHERNET
Management Port
PSTN Port
LINE
PSTN
VDSL Line Port
ERR
LINK
VDSL Line
LEDs
AT-MC602
Ethernet
Status
LEDs
10BaseT/
100BaseTX
LINK
ACT
PWR
AT-MC602
MGMT
VDSL EXTENDED ETHERNET
LINE
PSTN
ERR
LINK
VDSL Line
LEDs
Figure 2 Front Panels
Figure 3 illustrates the rear panels of the AT-MC601 and AT-MC602
network extenders.
AT-MC601
AT-MC602
12 VD C
DC Power Supply Port
12 VD C
Figure 3 Rear Panels
11
Page 12
Hardware Features
The following sections describe these hardware features of the AT-MC601
and AT-MC602 network extenders:
AT-MC601, AT-MC602 Installation and User’s Guide
❑ VDSL Line port
❑ PSTN port
❑ 10/100 Mbps twisted pair Ethernet port
❑ Status LEDs
❑ Management port
❑ Management cable
❑ DC power supply input port
❑ External AC/DC power adapter
VDSL Line PortThe VDSL Line port allows you to connect the AT-MC601 Subscriber unit
to a telephone jack (wall outlet) and the AT-MC602 Provider unit to the
inside phone line at the wiring closet. The two units need to be within
1,200 meters of each other in order for the port to operate properly. The
port transmits voice data at a frequency of 300-3400Hz and Ethernet data
at frequencies of 300 KHz to 8 MHz. This port features an RJ-11
connector.
Table 1 lists the RJ-11 port pinouts and their assignments.
Table 1 VDSL - RJ-11 Port Pinouts
PinAssignment
1pass-through 6
2pass-through 5
3VDSL and phone ring
4VDSL and phone tip
5pass-through 2
6pass-through 1
12
Page 13
Product Description
PSTN PortThe PSTN port allows you to connect the AT-MC601 Subscriber unit to a
telephone and the AT-MC602 Provider unit to the outside telco box. This
port features an RJ-11 connector.
Table 2 lists the RJ-11 port pinouts and their assignments.
Table 2 PSTN - RJ-11 Port Pinout
PinAssignment
1pass-through 1/6
2pass-through 2/5
3phone ring
4phone tip
5pass-through 5/2
6pass-through 6/1
10/100 Mbps
Twisted Pair
Ethernet Port
The AT-MC601 and AT-MC602 network extenders each have one twisted
pair Ethernet port. The twisted pair ports feature RJ-45 connectors with a
maximum operating distance of 100 meters (328 feet). For the port pinout
details, refer to ”RJ-45 Port Pinouts” on page 14.
Type of Cabling.The 10/100Base-TX twisted pair port on the ATMC601 and AT-MC602 network extenders are designed to operate with
Category 3 or better unshielded twisted pair cables. For 10 Mbps operation
on the twisted pair ports, Category 3 or better 100 ohm unshielded twisted
pair cabling is required. For 100 Mbps operation on the twisted pair ports,
Category 5 and Enhanced Category 5 (5E) 100 ohm unshielded twisted
pair cabling is recommended.
Auto MDI/MDI-X.An RJ-45 twisted pair port on a 10/100 Mbps
Ethernet network device can have one of two possible wiring
configurations: MDI or MDI-X. The RJ-45 port on a PC, router, or bridge
is typically wired as MDI, while the twisted pair port on a switch or hub is
usually MDI-X.
The AT-MC601 and AT-MC602 network extenders feature automatic
MDI/MDI-X. Each port automatically determines the configuration of the
port on the device to which it is connected and then configures itself
appropriately. For example, if a port on a network extender is connected to
a port on a bridge, which is typically wired as MDI, the port on the network
extender automatically configures itself as MDI-X. This feature allows you
to use either straight-through or crossover cables when connecting devices
to the network extender.
13
Page 14
AT-MC601, AT-MC602 Installation and User’s Guide
Auto-Negotiation.The network extenders Auto-Negotiate the speed
and duplex mode of the Ethernet link, so that the link comes up in the
highest performance configuration supported by both ends.
Half- and Full-duplex Mode.Duplex mode refers to the way an endnode sends and receives data on the network. An end-node can operate in
either half- or full-duplex mode, depending on its capabilities. An endnode that is operating in half-duplex mode can either send data or receive
data, but it cannot do both at the same time. An end-node that is operating
in full-duplex mode can send and receive data simultaneously. The best
network performance is achieved when an end-node can operate at fullduplex, since the end-node is able to send and receive data simultaneously.
The AT-MC601 and AT-MC602 network extenders can operate in either
half- or full-duplex mode. The network extender can operate with endnodes capable of either half-duplex, full-duplex, or that can AutoNegotiate the duplex mode. However, it is important to remember that the
two end-nodes connected to the ports on the network extenders must be
able to operate in the same duplex mode.
RJ-45 Port Pinouts.Figure 4 illustrates the pin assignments of an RJ45 connector and port.
8
1
8
1
Figure 4 RJ-45 Connector and Port Pin Assignments
Table 3 lists the RJ-45 10Base-T/100Base-TX connector pins and their
signals when the port is operating in either MDI or MDI-X configuration.
Table 3 RJ-45 Port Pinouts
PinMDI SignalMDI-X Signal
1TX+RX+
2TX-RX3RX+TX+
6RX-TX-
14
Page 15
Product Description
Status LEDsThe AT-MC601 and AT-MC602 network extenders feature the status
LEDs defined in Table 4.
Table 4 Status LEDs
LEDColorDescription
PWRGreenPower is applied to the unit.
10/100Base-TX Port
LINKGreenA link has been established on the port.
ACTGreenData is being received on the ports.
LINE Port
ERRGreenAn error has been detected on the port.
LINKGreenA link has been established on the port.
MGMT PortThe management port features a 8-pin DIN connector for connecting the
network extenders to your laptop or PC-compatible computer for
configuration using the provided management cable.
Management
Cable
The management cable included with the AT-MC602 Provider unit
features a 9-pin RS-232 connector to attach to your computer and an
8-pin DIN connector to attach to the network extender.
8-pin DIN connector
9-pin RS-232
connector
Figure 5 Management Cable
15
Page 16
AT-MC601, AT-MC602 Installation and User’s Guide
Table 5 lists the management cable connector pins and their signals.
Table 5 Management Cable Pinouts
RS-232 PinDIN PinSignal
11Not Used
22TXD
38RXD
45DSR
56GND
63DTR
74CTS
87RTS
DC Power
Supply Input
Port
External AC/DC
Power Adapter
9(N/A)Not Used
The network extender has a single DC power supply socket on the back
panel. The unit does not have a power switch. To turn the network extender
ON or OFF, you connect or disconnect the power cord.
An external AC/DC power adapter is included with the network extender
for desktop or wall-mount operation. The power adapter supplies 12V DC
to the network extender. Allied Telesyn supplies an approved safety
compliant AC power adapter specifically designed for each region the
network extender is sold. Each type of power adapter has an unregulated
output of 12V DC at 1A.
16
Page 17
Product Description
Software Features
The AT-S57 software used to configure the AT-MC601 and AT-MC602
network extenders has the following features:
❑ Determine the VDSL link status
❑ Set the upstream and downstream data transfer rates
❑ Monitor the status of the VDSL parameters on both the local and
remote units
❑ Monitor the status of the Ethernet parameters on both the local and
remote units
❑ Link recovery
Note
The features listed here are further described in ”Configuration” on
page 35.
17
Page 18
Chapter 2
Installation
This chapter contains the installation procedures for the network extenders.
The installation process is described in the following sections:
❑ Installation Safety Precautions
❑ Selecting a Site for the Network Extender
❑ Required Cables
❑ Unpacking the Network Extender
❑ Installing the AT-MC601 Subscriber Unit
❑ Installing the AT-MC602 Provider Unit
❑ Warranty Registration
18
Page 19
Installation
Installation Safety Precautions
Please review the following safety precautions before you begin to install
the network extenders. Refer to ”Translated Electric al Safety and Emission
Information” on page 54 for translated safety statements in your language.
Caution
Only use the power adapter supplied with the extender.
The AT-MC602 can be installed stand alone or can be inserted in the
AT-MCR12 chassis. In the last case, the AT-MC602 does no t need the
power adapter. 4
Caution
Power cord is used as a disconnection device: To de-energize
equipment, disconnect the power cord. 5
Warning
Lightning Danger: Do not work on this equipment or cables during
periods of lightning activity. 6
Caution
Air vents: The air vents must not be blocked on the unit and must have
free access to the room’s ambient air for cooling. 7
Caution
Operating Temperature: This product is designed for a maximum
ambient temperature of 40°C. 9
Caution
All Countries: Install this product in accordance with local and
national electric codes. 10
19
Page 20
AT-MC601, AT-MC602 Installation and User’s Guide
Additional
Compliance
Warning
Statements
Additional telecommunication-related compliance warning statements
used with the AT-MC601 and AT-MC602 Extended Ethernet units are
listed below:
Warning
When using your telephone equipment, basic safety precautions
should always be followed to reduce the risk of fire, electronic shock
and injury to persons, including the following:
1.Do not use this product near water, for example, near a bathtub,
washbowl, kitchen sink, or laundry tub in a wet basement or near
a swimming pool.
2.Avoid using a telephone (other than a cordless type) during an
electrical storm. There may be remote risk of electric shock from
lightning.
3.Do not use the telephone to report a gas leak in the vicinity of the
leak.
Caution
To reduce the risk of fire, use only No. 26 AWG or larger
telecommunication line cord.
Caution
Mechanical Mounting: The attached rackmounting ears must be used
to securely mount the device onto the rack.
20
Page 21
Installation
Selecting a Site for the Network Extender
Observe the following requirements when choosing a site for your network
extender:
❑ If you plan to install the AT-MCR12 in an equipment rack, check to
be sure that the rack is safely secured and that it will not tip over.
Devices in a rack should be installed starting at the bottom, with the
heavier devices near the bottom of the rack.
❑ If you are installing the network extender on a table, be sure that the
table is level and secure.
❑ The power outlet for the network extender should be located near the
unit and should be easily accessible.
❑ The site should provide for easy access to the ports on the front of
the network extender. This will make it easy for you to connect and
disconnect cables, as well as view the LEDs.
❑ To allow proper cooling of the network extender, air flow around the
unit and through its vents on the side should not be restricted.
❑ Do not place objects on top of the network extender.
❑ Do not expose the network extender to moisture or water.
❑ Make sure that the site is a dust-free environment.
❑ You should use dedicated power circuits or power conditioners to
supply reliable electrical power to the network extenders.
21
Page 22
Cables Not Included
The AT-MC601 and AT-MC602 network extenders require the three
cables described in Table 6 below. These cables are not included with the
network extenders.
PortCableConnector
AT-MC601, AT-MC602 Installation and User’s Guide
Table 6 Cables
EthernetCategory 3 or better
100-ohm unshielded
straight-through or
crossover twisted pair
cable
PSTNstandard telephone
cable
VDSL Linestandard telephone
cable
RJ-45
RJ-11
RJ-11
22
Page 23
Installation
Unpacking the Network Extender
To unpack the network extender:
1. Remove all components from the shipping package and store the
packaging material in a safe location.
Note
You must use the original shipping material if you need to return the
unit to Allied Telesyn.
2. Place the network extender on a level, secure surface.
3. Make sure the following hardware components are included in your
network extender package. If any item is missing or damaged, contact
your Allied Telesyn sales representative for assistance.
❑ One AT-MC601 or AT-MC602 Network Extender
❑ Four protective feet
❑ Two Phillips-head screws for wall-mounting
❑ Two plastic anchors for wall-mounting
❑ One cable lug
❑ One M4 x 8mm screw
❑ One power adapter
❑ One management cable (provided for AT-MC602 model only)
❑ Documentation and configuration software CD
❑ Warranty and registration card
23
Page 24
Installing the AT-MC601 Subscriber Unit
The AT-MC601 Subscriber unit will most likely be used as a stand-alone
device, or can be used as a desktop device, or mounted onto a wall, using
the keyholes on the bottom of the unit. The screws and plastic anchors used
for mounting the unit are provided.
AT-MC601, AT-MC602 Installation and User’s Guide
Using the
Subscriber Unit
on a Desktop
Wall-Mounting
the Subscriber
Unit
To use the Subscriber unit on a desktop, perform the following procedure:
1. Remove all equipment from the package and store the packaging
material in a safe place.
2. Attach the four protective feet (provided) to each corner of the bottom
of the unit, as illustrated in Figure 6.
AT-MC601
PWR
ACT
LINK
100BaseTX
10BaseT/
LINK
ERR
PSTN
LINE
VDSL EXTENDED ETHERNET
MGMT
Figure 6 Attaching Protective Feet to the Subscriber Unit
The Subscriber unit can be mounted onto a wall using the keyholes on the
bottom of the unit. The screws and plastic anchors used for mounting the
unit are provided.
To wall-mount the Subscriber Unit, perform the following procedure:
1. If attached, remove the protective feet, data cables, and power cord from
the unit.
2. Select a wall location for the device.
24
Page 25
Installation
3. Install the screws and plastic anchors onto the wall, as shown in Figure
7.
LINK
ERR
PSTN
LINE
VDSL EXTENDED ETHERNET
MGMT
AT-MC601
PWR
ACT
LINK
100BaseTX
10BaseT/
Figure 7 Installing the Screws and Plastic Anchors Onto The Wall
4. Position the switch onto the wall screws so that the ports are facing the
ceiling, as shown in Figure 8.
ERR
LINK
PSTN
10BaseT/
100BaseTX
LINE
AT-MC601
MGMT
VDSL EXTENDED ETHERNET
LINK
ACT
PWR
Figure 8 Positioning The Switch Onto The Wall Screws
25
Page 26
AT-MC601, AT-MC602 Installation and User’s Guide
Cabling the
Subscriber Unit
To cable the Subscriber unit, perform the following steps:
1. First, connect the Ethernet cable from the Ethernet port to the Ethernet
port on the computer, as shown in Figure 9.
1
0
B
a
s
e
T
/
1
0
0
B
a
s
e
T
X
L
I
N
K
A
C
T
P
W
R
A
T
-
M
C
6
0
1
V
D
S
L
E
X
T
E
N
D
L
I
N
E
M
G
M
T
E
D
E
T
H
E
R
N
E
T
E
R
R
P
S
T
N
L
I
N
K
Figure 9 Ethernet to Computer
2. Then, connect a telephone line cable from the PSTN port to the
telephone, as shown in Figure 10.
1
0
B
a
s
e
T
/
1
0
0
B
a
s
e
T
X
L
I
N
K
A
C
T
P
W
R
A
T
-
M
C
6
0
1
V
D
S
L
E
X
T
E
N
L
I
N
E
M
G
M
T
D
E
D
E
T
H
E
R
N
E
T
E
R
R
P
S
T
N
L
I
N
K
Figure 10 PSTN to Telephone
26
Page 27
Installation
M
C
R
1
2
LINE
10BaseT/
100BaseTX
LINK
ACT
PWR
ERR
LINK
MGMT
AT-MC602
VDSL EXTENDED ETHERNET
PSTN
3. Next, connect a telephone line cable from the VDSL Line port to the
wall/interior telephone line, as shown in Figure 11, so that the
Subscriber unit can communicate with the Provider unit.
1
0
B
a
s
e
T
/
1
0
0
B
a
s
e
T
X
L
I
N
K
A
C
T
P
W
R
A
T
-
M
C
6
0
1
V
D
L
I
N
E
M
G
M
T
S
L
E
X
T
E
N
D
E
D
E
T
H
E
R
N
E
E
R
R
P
S
T
N
L
I
N
T
K
Wall/Interior Phone Line
Figure 11 VDSL Line to Wall/Interior Phone Line
Note
The procedure for connecting the management cable is described in
”Cabling Preparations” on page 36.
Powering On the
Subscriber Unit
Power on the Subscriber unit using the power adapter provided, as shown
in Figure 12.
1
2
V
D
C
Figure 12 Power On The Subscriber Unit
27
Page 28
Installing the AT-MC602 Provider Unit
The AT-MC602 Provider unit can be installed in an AT-MCR12
rackmount chassis, used as a desktop device, or mounted onto a wall using
the keyholes on the bottom of the unit. The screws and plastic anchors used
for mounting the unit are provided.
Warning
To prevent exposure to electric shock, the AT-MC602 Provider Unit
must be installed in a RESTRICTED ACCESS LOCATION and
performed by QUALIFIED SERVICE PERSONNEL.
Note
For Finland, Norway, and Sweden – When the AT-MC602 and the
AT-MCR12 are used, a permanent ground conductor must be installed
on the AT-MCR12 chassis.
For installation instructions of this ground conductor, refer to the AT-MCR12 Media Converter Rackmount Chassis Installation Manual
(PN 613-10725-00).
AT-MC601, AT-MC602 Installation and User’s Guide
Using the
Provider Unit on
a Desktop
To use the Provider unit on a desktop, perform the following procedure:
1. Remove all equipment from the package and store the packaging
material in a safe place.
2. Attach the four protective feet (provided) to each corner of the bottom
of the unit, as illustrated in Figure 6.
AT-MC602
PWR
ACT
LINK
100BaseTX
10BaseT/
LINK
ERR
PSTN
LINE
VDSL EXTENDED ETHERNET
MGMT
Figure 13 Attaching Protective Feet to the Provider Unit
28
Page 29
Installation
Wall-Mounting
the Provider
Unit
The Provider unit can be mounted onto a wall using the keyholes on the
bottom of the unit. The screws and plastic anchors used for mounting the
unit are provided.
To wall-mount the Provider Unit, perform the following procedure:
1. If attached, remove the protective feet, data cables, and power cord from
the unit.
2. Select a wall location for the device.
3. Install the screws and plastic anchors onto the wall, as shown in Figure
7.
LINK
ERR
PSTN
LINE
VDSL EXTENDED ETHERNET
MGMT
AT-MC602
PWR
ACT
LINK
100BaseTX
10BaseT/
Figure 14 Installing the Screws and Plastic Anchors Onto The Wall
4. Position the switch onto the wall screws so that the ports are facing the
ceiling, as shown in Figure 8.
ERR
LINK
PSTN
10BaseT/
100BaseTX
LINE
AT-MC602
MGMT
VDSL EXTENDED ETHERNET
LINK
ACT
PWR
Figure 15 Positioning The Switch Onto The Wall Screws
29
Page 30
AT-MC601, AT-MC602 Installation and User’s Guide
C
Grounding the
Provider Unit
When an AT-MC602 Provider unit is used as a standalone network
extender, you must ground the unit to a ground point to ensure a safe and
proper operation.
Grounding the chassis requires the following items:
❑ One cable lug (provided)
❑ One M4 x 8mm screw (provided)
❑ Crimping tool (not provided)
❑ One 12 AWG stranded wire or 14 AWG solid wire (not provided)
Warning
Make sure to attach the frame to ground before you power on the
chassis.
To ground the unit to the ground point, perform the following procedure:
1. Use a crimping tool to affix the provided cable lug to one end of the 12
AWG bundled or 14 AWG solid ground wire.
2. Insert the M4 screw into the cable lug, as illustrated in Figure 16.
Figure 16 Inserting M4 Screw into the Cable Lug
3. Secure the cable lug with the M4 screw to the rear panel of the Provider
unit, as illustrated in Figure 17.
Figure 17 Securing Cable Lug with M4 Screw
4. Attach the other end of the ground wire to an appropriate ground (earth)
rod of the building.
30
Page 31
Installation
Rack-Mounting
the Provider
Unit
To install the Provider unit in an AT-MCR12 rackmount chassis, perform
the following steps:
1. Attach the unit to one of the sliders that will hold the unit in the chassis,
as shown in Figure 18.
LINK
ERR
PSTN
LINE
MGMT
VDSL EXTENDED ETHERNET
AT-MC601
PWR
ACT
LINK
10BaseT/
100BaseTX
Figure 18 Rack Mount - Set on Slider
2. Then, set the slider in the chassis, as shown in Figure 19.
12
R
C
M
LINK
ERR
PSTN
LINE
MGMT
VDSL EXTENDED ETHERNET
AT-MC601
PWR
ACT
LINK
10BaseT/
100BaseTX
Figure 19 Rack Mount - Set in Rack
R
E
W
O
P
31
Page 32
AT-MC601, AT-MC602 Installation and User’s Guide
MCR12
LINE
10BaseT/
100BaseTX
LINK
ACT
PWR
ERR
LINK
MGMT
AT-MC603
VDSL EXTENDED ETHERNET
PSTN
M
C
R
1
2
LINE
10BaseT/
100BaseTX
LINK
ACT
PWR
ERR
LINK
MGMT
AT-MC603
VDSL EXTENDED ETHERNET
PSTN
Cabling the
Provider Unit
To cable the Provider unit, perform the following steps:
1. First, connect the Ethernet cable from the Ethernet port to the Service
Provider box in your wiring closet, as shown in Figure 20.
Internet
Service
Provider
Figure 20 Ethernet to Internet Service Provider
2. Then, connect a telephone line cable from the PSTN port to the outside
telco box, as shown in Figure 21.
Telco
PBX
Line
Figure 21 PSTN to Telco PBX Line
32
Page 33
Installation
M
C
R
1
2
LINE
10BaseT/
100BaseTX
LINK
ACT
PWR
ERR
LINK
MGMT
AT-MC602
VDSL EXTENDED ETHERNET
PSTN
3. Next, connect a telephone line cable from the VDSL Line port to the
wall/interior telephone line, as shown in Figure 22, so that the Provider
unit can communicate with the Subscriber unit.
1
0
B
a
s
e
T
/
1
0
0
B
a
s
e
T
X
L
I
N
K
A
C
T
P
W
R
AT-MC601
L
I
N
E
M
G
M
T
V
D
S
L
E
X
T
E
N
D
E
E
R
R
P
S
T
N
L
I
D
N
K
E
T
H
E
R
N
E
T
Wall/Interior Phone Line
Figure 22 VDSL Line to Wall/Interior Phone Line
Note
The procedure for connecting the management cable is described in
”Cabling Preparations” on page 36.
Powering On the
Provider Unit
Powering on the AT-MC602 Provider Unit requires that the host
equipment, AT-MCR12 rackmount chassis, is powered on as well.
Warning
The QUALIFIED SERVICE PERSONNEL must verify that the
AT-MCR12 power cord is connected to the socket provided with the
ground conductor.
If the power cord is not connected, the QUALIFIED SERVICE PERSONNEL must install a permanent ground connection using the
bond stud on the rear panel of the AT-MCR12 chassis.
For detailed information on how to power on the AT-MCR12 unit, refer to
the AT-MCR12 Media Converter Rackmount Chassis Installation Manual.
33
Page 34
Warranty Registration
When you have finished installing the network extender, register your
product by completing the enclosed warranty card and mailing it to Allied
Telesyn.
AT-MC601, AT-MC602 Installation and User’s Guide
34
Page 35
Chapter 3
Configuration
The configuration software allows you to adjust and monitor the operating
parameters of the media converter. Some of the functions that you can
perform with the software include:
❑ Determine the VDSL link status
❑ Set the upstream and downstream data transfer rates
❑ Monitor the status of the VDSL parameters on both the local and
remote units
❑ Monitor the status of the Ethernet parameters on both the local and
remote units
❑ Link recovery
The AT-S57 configuration software is included on the Documentation CD
included with the network extender. The default settings may be adequate
for some networks and may not need to be changed. If this is true for your
network, then you can use the network extenders by simply connecting the
units to your network, as explained in ”Installation” on page 18.
Note
The default settings for the configuration software can be found in
Appendix A”” on page 51.
To actively configure a network extender by changing or adjusting its
operating parameters, you must access the AT-S57 software while
connected to the AT-MC602 Provider unit. The AT-S57 software has a
menu interface that makes it very easy to use.
35
Page 36
Starting a Configuration Session
AT-MC601, AT-MC602 Installation and User’s Guide
Downloading
Software Updates
Cabling
Preparations
In order to configure and manage your AT-MC601 and AT-MC602 VDSL
network extenders, you need to download a copy of the configuration
software onto the computers you will use to manage the units. The AT-S57
configuration software is included on the Documentation CD provided
with the units.
New releases of the AT-S57 configuration software are available from the
Allied Telesyn Web site at www.alliedtelesyn.com or from our FTP server
atftp.alliedtelesyn.com. To log on to the FTP server, enter “anonymous”
for the user name and your email address for the password. Management
software for the AT-MC601 and AT-MC602 VDSL network extenders
will have “S57” as part of the file name.
Once you have a copy of the software on your computer, connect the
Provider unit to your computer using the management cable provided, as
shown in Figure 23. Attach the 9-pin RS-232 end of the cable to the COM
1 or COM 2 port on your computer. Attach the 8-pin DIN end of the cable
to the management port on the unit.
1
0
B
a
s
e
T
/
1
0
0
B
a
s
e
T
X
L
I
N
K
A
C
T
P
W
R
A
T
-
M
C
6
0
2
M
G
M
VDSL EXTENDED ETHERNET
T
L
I
N
E
E
R
P
S
T
N
R
L
I
N
K
Figure 23 Connecting the Management Cable
If the network extender is not already on, power on the unit using the
power cable provided. Refer to ”Powering On the Subscriber Unit” on page
27 for further instructions on how to power on the unit.
36
Page 37
Configuration
Opening the
Configuration
Software
Open the configuration software by double-clicking the “ATS57”
application icon, as you would with any other software program. The ATMC60x Configurator pop-up will appear, as shown in Figure 24.
Figure 24 AT-MC60x Configurator
If you would like to verify that you are using the latest version of the
configuration and management software, click the About button on the
bottom right of the AT-MC60x Configurator pop-up. The About ATMC60x Configurator pop-up will appear, as shown in Figure 25.
Figure 25 About AT-MC60x Configurator
Select the computer port you are using from the pull-down menu on the
AT-MC60x Configurator pop-up and click OK.
If you are connected to the AT-MC602 Provider unit and want to configure
the network extenders, continue with the next section, ”Configuring the
Provider Unit” on page 38. If you are connected to the AT-MC601
Subscriber unit to attempt link recovery, continue with ”Configuring the
Subscriber Unit” on page 45.
37
Page 38
AT-MC601, AT-MC602 Installation and User’s Guide
Configuring the Provider Unit
After performing the procedure described in the previous section, ”Starting
a Configuration Session” on page 36, if you are connected to the Provider
unit, the AT- MC60x Configurator menu will appear. The Configurator bar
at the top of the menu indicates whether or not the Provider unit has
established an Ethernet link by displaying [link DOWN] or [link UP] in
brackets.
The AT-MC60x Configurator menu has three screens: Configuration,
VDSL Status, and Ethernet Status. The parameters on these screens are
described below. Use the tabs at the top of the menu to toggle between
these screens. When you have finished viewing or adjusting the parameters
on the menu screens, click the Close button on the bottom right of the menu
to exit from the configuration software.
ConfigurationThe Configuration screen displayed in Figure 26 is shown first by default.
Figure 26 Configuration
38
Page 39
Configuration
The parameters on the Configuration screen are described below.
Upstream/Downstream
The upstream and downstream data transfer rate.
❑ Actual (Mbps)
Displays the actual data transfer rate on the line. The software
automatically detects this speed.
❑ Min (Mbps)
Allows you to adapt the data transfer rate by setting a minimum
speed.
❑ Max (Mbps)
Allows you to adapt the data transfer rate by setting a maximum
speed.
The maximum and minimum speeds in Mbps available in the pull-down
menus are:
0.94
1.06
1.41
1.88
2.11
2.81
3.75
4.22
5.63
7.50
8.44
11.26
15.01
16.88 (upstream only)
Status
This field will display “Select speed to set” until you have selected data
rates from the upstream and downstream pull-down menus and set the rates
by clicking the Apply button. Then reports on the status of the attempt to
configure the speeds selected from the upstream and downstream pulldown menus will appear in this field. A successful configuration attempt
will cycle though the following status reports:
Looking for link status...
Checking signal/noise ratio
Loading a Configuration DS=1.41 US=2.81
(This report will keep repeating with progressively higher
upstream and downstream values until the set rate or the
highest possible rate has been achieved.)
Saving config on EEPROM - S Side
Saving config on EEPROM - P Side
Done
39
Page 40
AT-MC601, AT-MC602 Installation and User’s Guide
The Configuration Saved pop-up shown in Figure 27 will appear when the
set rate or the highest possible rate has been achieved.
Figure 27 Configuration Saved
An unsuccessful configuration attempt may include the following status
reports:
Loading defaults
Can’t read link status
Done
These negative status reports may also be accompanied by error message
pop-ups. Error messages are explained in ”Troubleshooting” on page 47.
HIGH -> LOW/LOW -> HIGH
Allows you to choose the negotiation direction for the modem speed. The
default and preferred direction is Low -> High. Choosing a negotiation
direction determines how the modem searches for speeds . When set to Lo w
-> High, the modem will start at minimum speeds and keeps negotiating
progressively higher speeds until it has achieved its maximum speed for
the connection.
Apply
Press the Apply button to set your data transfer rates and negotiation
direction selections.
About
Use the About button to display the version number of the AT-S57
configuration software.
40
Page 41
Configuration
VDSL StatusTo view the VDSL Status screen, click on the VDSL Status tab at the top of
the menu.
The VDSL Status screen is displayed in Figure 28.
Figure 28 VDSL Status
The parameters on the VDSL Status screen are described below. These
parameters are for viewing and monitoring purposes only. They cannot be
changed manually.
SNR of Received Signal
The Signal-to-Noise Ratio on the VDSL line, measured in decibels. The
SNR is a parameter of the constellation of the receive signal.
Corrected RS errors /s
Number of corrected Reed-Solomon errors per second.
Mean Square Error
An indication of the symbol error rate, measured in decibels.
Full Constellation Link
The highest possible QAM (Quadrature Amplitude Modulation)
constellation, which enables the highest line rates.
41
Page 42
AT-MC601, AT-MC602 Installation and User’s Guide
Reduced Constellation Link
A lesser QAM constellation, causing reduced line rates. If the full
constellation rate cannot be achieved because the received SNR is too low,
then a reduced constellation link can be established and the software can
automatically configure the Subscriber unit parameters.
TC Synchronized
Transmission convergence is synchronized.
Ethernet Encapsulation Sync
The process of encapsulating packets into frames at the VDSL link level is
synchronized.
Remote I/F Synchronized
Remote interface is synchronized.
Signal Detected
The VDSL signal is being detected by the software.
Link Fail Counter
Number of unsuccessful link attempts.
Micro Interruption Occurred
A micro-interruption occurred.
AGC Converged
Automatic gain control has converged on the VDSL link.
Timing Converged
The timing acquisition function is converged. This only occurs on the
Subscriber (remote) unit
ADC Saturation
Analog-to-digital converter has been overloaded with interference.
Local/Remote
Select Local to view the pa ramete rs fo r the Provider unit. S elect Remote to
view the parameters for the Subscriber unit. The Remote option will only
be available when an active link has been established.
42
Page 43
Configuration
Ethernet StatusTo view the Ethernet Status screen, click on the Ethernet Status tab at the
top of the menu.
The Ethernet Status screen is displayed in Figure 29.
Figure 29 Ethernet Status
The parameters on the Ethernet Status screen are described below.
TxRx Counters
The data fields in this section indicate the number and type of frames that
have been transmitted and received via the Ethernet link.
Collision Counters
The data fields in this section indicate the number and type of collisions
that have occurred on the Ethernet link.
Error Counters
The data fields in this section indicate the number and type of errors that
have occurred on the Ethernet link.
Clear
This button allows you to reset the counters, clearing the values previously
recorded by the software.
43
Page 44
AT-MC601, AT-MC602 Installation and User’s Guide
Stop/Start
This button allows you to pause counting. When you press Stop, the
counters remain at their present values. When you press Start, the counters
continue adding to the values already recorded by the software.
Local/Remote
Select Local to view the pa ramete rs fo r the Provider unit. S elect Remote to
view the parameters for the Subscriber unit. The Remote option will only
be available when an active link has been established.
44
Page 45
Configuration
Configuring the Subscriber Unit
In rare instances, you may need to use the configuration software on the
Subscriber unit to attempt link recovery. If the configuration software
detects a problem with the Subscriber unit while you are connected to the
Provider unit, it will prompt you to use the software on the Subscriber unit
by displaying a pop-up error message. On these occasions, follow the
procedure described in ”Starting a Configuration Session” on page 36 and
then continue with the instructions in this section.
After you have selected the correct port and clicked the OK button, the ATMC60x Configurator Select Mode screen will appear, as displayed in
Figure 30.
Figure 30 Select Mode
There are two options on the Select Mode screen: Normal and Install.
These options are described below:
Normal
The Normal mode sets the units to operate under normal parameters. The
units will attempt to establish a link using the parameters you set on the
Configuration screen while connected to the Provider unit. See
”Configuration” on page 38 for a description of the Configuration screen.
Using the Normal mode will only allow the units to establish links that
meet the criteria you have set. The disadvantage to using the Normal mode
is that if either of the upstream or downstream speeds you have set are
unattainable, the link attempt will fail because the units are not set to use
the default parameters as back-ups.
Install
The Install mode enables a watchdog timer to monitor the link attempt
process. If the network extenders are not able to establish a link using the
parameters you set on the Provider unit within a reasonable amount of
45
Page 46
AT-MC601, AT-MC602 Installation and User’s Guide
time, a timeout will occur. After a timeout, the default configuration
parameters will be used to establish a link with the highest possible speed.
The default configuration parameters start at 0.94 Mbps upstream and
downstream with negotiation set from Low -> High.
Select the option that corresponds to your mode choice and click the Apply
button.
When the mode has been set, the AT-MC60x Configurator Done message
will appear, as displayed in Figure 31.
Figure 31 Done Message
When you have finished setting the mode on the Subscriber unit, click the
Close button on the bottom right of the AT-MC60x Configurator menu to
exit from the configuration software.
46
Page 47
Chapter 4
Troubleshooting
This chapter contains information on how to troubleshoot the
AT-MC601 and AT-MC602 network extenders in the event a problem
occurs.
Note
If after following the instructions in this chapter you are unable to
resolve the problem, contact Allied Telesyn Technical Support for
assistance. Refer to ”Contacting Allied Telesyn Technical Support” on
page 8 for information on how to contact our Technical Support
Department.
LEDsCheck the PWR LED on the front of the network extender. If the LED is
OFF, indicating that the network extender is not receiving power, do the
following:
❑ If the network extender is inserted in the AT-MCR12 chassis, make
sure that the power cord is securely connected to the power source
and to the power connector on the back panel of the
AT-MCR12 chassis.
❑ If the network extender stands alone, make sure that the provided
adapter is securely connected to the power source and to the power
connector on the back panel of the network extender.
❑ Verify that the power outlet has power by connecting another device
to it.
❑ Try connecting the network extender to another power source.
❑ Try using a different power cord or a different power adapter.
❑ Check that the voltage from the power source is within the required
levels for your region.
47
Page 48
AT-MC601, AT-MC602 Installation and User’s Guide
Verify that the ACT LED for each twisted pair port is ON. If a ACT LED is
OFF, do the following:
❑ Verify that the end node connected to the port is powered ON and is
operating properly.
❑ Check that the twisted pair cable is securely connected to the port on
the network extender and to the port on the end node.
❑ Make sure that the twisted pair cable does not exceed 100 meters
(328 feet).
❑ Verify that you are using the appropriate category of twisted pair
cable: Category 3 or better for 10 Mbps operation, Category 5 and
Category 5E for 100 Mbps operation.
❑ Make sure that the operating parameters of the port on the network
extender are compatible with the end node to which the port is
connected.
Error MessagesWhen using the configuration software, you may encounter the following
error messages:
❑ “No answer from device,” as shown in Figure 32
Figure 32 No Answer Error Message
This error message may occur when your computer is not
responding, in which case you should re-start your computer and try
again.
❑ “Communication error: the program will be closed. Verify serial
connection and restart the program
,” as shown in Figure 33
Figure 33 Communication Error Message
48
Page 49
Troubleshooting
If you are unable to establish a configuration session with the
network extender and receive this error message, check to be sure
that the management cable is securely connected to the management
port on the network extender and to the RS-232 port on the
computer. Then make sure you are selecting the correct COM1 or
COM2 port at the software prompt.
❑ “Max speed cannot be lower than min speed: select different
values
”
This error message occurs when you select a maximum speed that is
lower than the set minimum speed during the selection of speed
ranges on the rate adaptation section on the Configuration menu
screen. Select a higher maximum value to correct the problem.
❑ “P side must be connected to start this procedure” or “S side must
be connected to start this procedure
”
These error messages occur when the management cable is
connected to the wrong unit for the procedure you are trying to
perform.This could happen if you switch the management cable
between the units without closing the software window. Simply
switch the management cable to the other unit to correct the
problem.
❑ “Can't read link status”
This message occurs when the software cannot read the link status
from the Provider side. Perform the procedure described in
”Configuring the Subscriber Unit” on page 45 to see if link recovery
on the Subscriber unit solves the problem.
❑ “Please run this program on S side to set it in Install mode. If S side
is already in install mode then configuration can not be
achieved,”
as shown in Figure 34.
Figure 34 Run on S Side Error Message
This error message occurs when the Provider unit cannot achieve the
link with the S or Subscriber side unit using the default speeds value.
Set the Subscriber to Install Mode, as described in ”Configuring the
Subscriber Unit” on page 45.
49
Page 50
AT-MC601, AT-MC602 Installation and User’s Guide
❑ “Configuration file was not found”
❑ “Syntax error in configuration file”
❑ “Configuration cannot be achieved”
These last three error messages indicate a problem with the
configuration software. Try re-loading the software onto your
computer.
50
Page 51
Appendix A
Default Configuration Settings
This appendix lists the AT-MC601 and AT-MC602 default settings.
109 mm x 95 mm x 25 mm
(4.29 in. x 3.74 in. x 0.98 in.)
Weight: .27 kg (0.6 lbs)
Recommended Minimum
Clearance on All Sides:5.08 cm (2.0 in.)
Environmental Specifications
Operating Temperature:0° C to 40° C (32° F to 104° F)
Storage Temperature:-25° C to 70° C (-13° F to 158° F)
Operating Humidity:5% to 90% (noncondensing)
Storage Humidity:5% to 95% (noncondensing)
Operating Altitude:3,000 m (approx. 10,000 ft)
Non-operating Altitude:4,000 m (approx.13,100 ft)
Power Specifications
Power Consumption:6 Watts
Input Supply Current:500 mA
Input Supply Voltage:12V DC
52
Page 53
Technical Specifications
Safety and Electromagnetic Compatibility Certifications
Translated Electrical Safety and
Emission Information
Important: This appendix contains multiple-language translations for
the safety statements in this guide.
Wichtig: Dieser Anhang enthält Übersetzungen der in diesem
Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen.
Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af
sikkerhedsadvarslerne i denne håndbog.
Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de
veiligheidsopmerkingen in deze gids.
Important: Cette annexe contient la traduction en plusieurs langues
des instructions de sécurité figurant dans ce guide.
Tärkeää: Tämä liite sisältää tässä oppaassa esiintyvät turvaohjeet
usealla kielellä.
Importante: questa appendice contiene traduzioni in più lingue degli
avvisi di sicurezza di questa guida.
Viktig: Dette tillegget inneholder oversettelser til flere språk av
sikkerhetsinformasjonen i denne veiledningen.
Importante: Este anexo contém traduções em vários idiomas das
advertências de segurança neste guia.
Importante: Este apéndice contiene traducciones e n múlti ples idi omas
de los mensajes de seguridad incluidos en esta guía.
Obs! Denna bilaga innehåller flerspråkiga översättningar av
säkerhetsmeddelandena i denna handledning.
54
Page 55
Translated Electrical Safety and Emission Information
Standards: This product meets the following safety standards.
1RFI EmissionEN55022 Class A, FCC Part 15 Class A
2ImmunityEN55024
3Elec trical SafetyEN60950, UL60950, FCC Part 68
4Only use t he power adapter supplied with the extender.
5Caution: Power cord is used as a disconnection device. To de-energize equipment
6Lightning Danger
7Do not block air vents.
8Do not connect a telephone line into the signal connector.
9Operating Temperature: This product is designed for a maximum ambient
Safety
The AT-MC602 can be installed stand alone or can be inserted in the AT-MCR12
chassis. In the last case, the AT-MC602 doe s not need the power adapter.
disconnect the power cord.
Danger: Do not work on eq uipm en t or ca bles du rin g pe riods of lightn ing a ctivity.
temperature of 40 degrees C.
10All Countries: Install product in accordance with local and National Electrical Codes.
55
Page 56
AT-MC601, AT-MC602 Installation and User’s Guide
Normen: Dieses Produkt erfüllt die Anforderun gen der nachfolgenden Norm en.
1HochfrequenzstörungEN55022 Klasse A, FCC Part 15 Klasse A
2StörsicherheitEN55024
3Elektrische Sicherheit EN60950, UL60950, FCC Part 68
Sicherheit
4Bitte den Adapter nur mit dem mitgelieferten Extender benutzen.
Die AT-MC602 kann einzeln benutzt werden oder in der AT-MCR12 Einheit. Im
letzteren Fall braucht der AT-MC602 keinen Adapter.
5Vorsicht: Das netzkabel dient zum trennen der stromversorgung. Zur trennung vom
netz, kabel aus der steckdose zi ehen.
6Gefahr Durch Blitzschlag
Gefahr: Keine Arbeiten am Gerät oder an den Kabeln während eines Gewitters
ausführen.
7Entlüftungsöffnungen nicht versperren.
8Verbinden Sie nicht das Tel efonkabel mit dem Signalverbindungsstecker.
9Betriebstemperatur: Dieses Produkt wu r de f ür den Betrieb in einer
Umgebungstemperatur von nicht mehr als 40° C entwor fen.
10Alle Länder: Installation muß örtlichen und nationalen elektrischen Vorschriften
entsprechen.
56
Page 57
Translated Electrical Safety and Emission Information
1 Radiofrekvens forstyrrelsesemissionEN55022 Klasse A, FCC Part 15 Klasse A
2ImmunitetEN55024
3Elektrisk sikkerhedEN60950, UL60950, FCC Part 68
4Ved in stallation af converteren må man kun benytte de n med købte PSU.
5Advarsel: Den strømførende ledning bruges til at afbryde strømmen. Skal strømmen til
6Fare Under Uvejr
7Ventilationsåbningerne må ikke blokeres.
8Tilslut ikke telefonledninger til signalstikforbindelsen.
9Betjeningstemperatur: Dette apparat er konstrueret til en omgivende temperatur på
Standarder: Dette produkt tilfredsstiller de fø lgende stand arder.
Sikkerhed
AT-MC602 converteren kan installeres som enkelt node eller installeres i et
AT-MCR12 chassis. Ved installation i AT-MCR12 chassis, skal man ikke benytte
PSU'en.
apparatet afbryd es, tages ledningen ud af stik ket.
Fare: UNDLAD at arbejde på udstyr eller KABLER i perioder med LYNAKTIVITET.
maksimum 40 grader C.
10Alle Lande: Installation af pro duktet skal sk e i overen sstemmelse med lokal og nationa l
lovgivning for elektriske installationer.
57
Page 58
AT-MC601, AT-MC602 Installation and User’s Guide
Eisen: Dit product voldoet aan de volgende eisen .
1RFI EmissieEN55022 Klasse A, FCC Part 15 Klasse A
2ImmuniteitEN55024
3Electrische VeiligheidEN60950, UL60950, FCC Part 68
Veiligheid
4Gebr uik alleen de power adapter di e meegeleverd is met de verlenger.
De AT-MC602 kan als stand alone gebruikt worden, maar kan ook geplaatst worden in
de AT-MCR12 chassis. In het laatste geval heef t de AT-MC602 zijn powersupply niet
nodig.
5Waarschuwing: Het toestel wordt uitgeschakeld door de stroomkabel te ontkoppelen.
Om het toestel stro omloos te maken: de stro omkabel ontkoppelen.
6Gevaar Voor Blikseminslag
Gevaar: NIET aan toestellen of KAB ELS WERKEN bij BLIKSE M.
7Ventilatiegaten niet blokkeren.
8Slu it geen telefoonl ij n aan op de signaalver binding.
9Bedrijfstemperatuur: De omgevingstemperatuur voor di t produkt mag niet meer
bedragen dan 40 grad en Celsius.
10Alle Landen: het toestel installeren overeenkomstig de lokale en nationale elektrische
voorschriften.
58
Page 59
Translated Electrical Safety and Emission Information
1Eemission d’interférence s EN55022 Class A, FCC Part 15 Class A
2Immunité EN55024
3Sécur ité électriqueEN60950, UL60950, FCC Part 68
4Utiliser uniquement l’adapteur aleatoire fourni avec l’extender.
5Attention: Le cordon d’alimentati on sert de mise hors circuit. Pour couper
6Dan ger De Foudre
7Ne pas bl oquer les fentes d’aération.
8Ne pas connecter une ligne téléphonique au connecteur de signaux.
9Température De Fonctionnement: Ce matériel est capable de tolérer une température
Normes: ce produit est conforme aux normes de suivante s.
radioélectriques
Sécurité
Le AT-MC602 peut etre installe d’une faco n autonome, ou insere dans le AT-MCR12
chassis. Dans le deuxieme cas, le AT-MC602 n’a pas besoin de l’adapteur al eatoire.
l’alimentation du matériel, débrancher le cordon.
Danger: NE PAS MANIER le matériel ou les CÂBLES lors d’activité orageuse.
ambiante maximum de 40 deg r és Celsius.
10Pour Tous Pays: Installer le matériel conformément aux normes électriques nationales
et locales.
59
Page 60
AT-MC601, AT-MC602 Installation and User’s Guide
Standardit: Tämä tuote on seuraavien standa rdi en mukainen.
1Radioaaltojen häirintä EN55022 Class A, FCC Part 15 Class A
2Kestävyys EN55024
3SähköturvallisuusEN60950, UL60950, FCC Part 68
Turvallisuus
4Käytä vain muuntimen mukana toimitettua virtalaitetta.
AT-MC602 voidaan käyttää itsenäisesti tai asennettuna AT-MCR12-kehikkoon,
jälkimmäisessä tapauksessa AT-MC602 ei tarvitse erillistä virtalaitetta.
5Huomautus: Virtajohtoa käytetään virrankatkaisulaitteena. Virta katkaistaan
irrottamalla virtajohto.
6Salamaniskuvaara
Hengenvaara: ÄLÄ TYÖSKENTELE laitteiden tai KAAPELEIDEN KANSSA
SALAMOINNIN AIKANA.
7Älä tuki i lmareikiä
8Älä liitä puhelinlinjaa signaalin liittimeen.
9Käyttölämpötila: Tämä tuote on suunniteltu ympäröivän ilman maksimilämpötilalle
40° C.
10Kaikki Maat: Asenna tuote paikallisten ja kansallisten sähköturvallisuusmääräysten
mukaisesti.
60
Page 61
Translated Electrical Safety and Emission Information
1Emissione RFI (interferenza di EN55022 Classe A, FCC Pa r t 15 Classe A
2Immunità EN55024
3Sicurezz a el ettricaEN6095 0, UL60950, FCC Part 68
4Questo dispositivo deve essere alimentato solo mediante il proprio adattatore.
5Attenzione: Il cavo di alimentazione è usato come dispositivo di disattivazione. Per
6Pericolo Di Fulmini
7Non ostruire le prese d’aria.
Standard: Questo prodotto è conforme ai seguen ti standard.
radiofrequenza)
Norme Di Sicurezza
Il dispositivo AT-M C60 2 pu o' es sere ins ta llato a se' stante o puo' essere inserito
nell' unita' AT-MCR12. In questo ultimo caso, il dispositivo AT-MC602 non richiede
l' adattatore.
togliere la corrente al dispositivo staccare il cavo di alimentazione.
Pericolo: NON LAVORARE sul dispositivo o sui CAVI durante PRECIPITAZIONI
TEMPORALESCHE.
8Non coll egare una linea telefonica al co nnettore del segnale.9Temperatura Di Funzionamento: Questo prodotto è concepito per una temperatura
ambientale massima di 40 gradi centigradi.
10Tutti I Paesi: installare il prodotto in conformità delle vigenti normative elettriche
nazionali.
61
Page 62
AT-MC601, AT-MC602 Installation and User’s Guide
Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer.
1RFI stråling EN55022 Klasse A, FCC Part 15 Klasse A
2ImmunittetEN55024
3Elektrisk sikkerhetEN60950, UL60950, FCC Part 68
Sikkerhet
4Ved installation av converteren må man kun benytte den med tilhørende PSU.
AT-MC602 converteren kan installeres som enkel node eller installeres i et
AT-MCR12 chassis. Ved installation i AT-MCR12 chassis, skal man ikke benytte
PSU'en.
5Forsiktig: Strømledningen brukes til å frakobl e utsty re t. For å deaktivisere utstyret, må
strømforsyningen kobles fra.
6Fare For Lynneds l a g
Fare: ARBEID IKKE på utstyr eller KABLER i TORDENVÆR.
7Blokker ikke luftventilene.
8Telefonlinje må ikke koples til signalkontakten.
9Driftstemperatur: Dette produktet er konstruert for bruk i maksimum romtemperatur
på 40 grader celsius.
10Alle Land: Produktet må installeres i samsvar med de lokale og nasjonale elektriske
koder.
62
Page 63
Translated Electrical Safety and Emission Information
1Emissão de interferência de EN55022 Class A, FCC Pa r t 15 Cl as s A
2ImunidadeEN55024
3Segurança eléctricaEN60950, UL60950, FCC P art 68
4Use apena s adaptador de energia fornecido pelo extensão.
5Cuidado: O cabo de alimentação é utilizado como um dispositivo de desconexão. Para
6Perigo De Choque Causado Por Raio
7Não bloqueie as aberturas de ventilação.
Padrões: Este produto atende aos seguintes padrões.
radiofrequência
Segurança
O AT-MC602 pode ser instalado de maneira independente ou pode ser colocado dentro
da unidade AT-MCR12. No último caso o AT-MC602 não precisa de adaptador de
energia.
deseletrificar o equipamento, desconecte o cabo de ALIMENTAÇÃO.
Perigo: NÃO TRABALHE no equipamento ou nos CABOS durante períodos
suscetíveis a QUEDAS DE RAIO.
8Não conecte uma linha telefônica ao con ector de sinal.9Temperatura De Funcionamento: Este produto foi projetado para uma temperatu ra
ambiente máxima de 40 graus centígrados.
10Todos Os Países: Instale o produto de acordo com as normas nacionais e lo cais para
instalações elétricas.
63
Page 64
AT-MC601, AT-MC602 Installation and User’s Guide
Estándares: Este producto cumple con los siguientes estándares.
1Emisión RFIEN55022 Clase A, FCC Part 15 Clase A
2InmunidadEN55024
3Seguridad eléctricaEN60950, UL60950, FCC Part 68
Seguridad
4Use únicamente el adaptador de corriente suministrado junto con el extensor.
El extensor AT-MC602 puede ser instalado en stand alone o puede ser inserta do en la
unidad AT-MCR12. En este ultimo caso el extensor AT-MC602 no necesita el
adaptador de corriente suministrado.
5Atencion: El cable de alimentacion se usa como un dispositivo de desconexion. Para
desactivar el equipo, desconecte el cable de alimentación.
6Peligro De Rayos
Peligro: NO REALICE NINGUN TIPO DE TRABAJO O CONEXION en los equipos
o en LOS CABLES durante TORMENTAS ELECTRICAS.
7No bloquee las aberturas para ventilacion.
8No conectar ninguna línea telefónica al conector de señales.
9Temperatura Requerida Para La Operación: Est e pr oducto está diseña do para una
temperatura ambiental máxima de 40 grados C.
10Para Todos Los Países: Monte el producto de acuerdo con los Códigos Eléctricos
locales y nacionales.
64
Page 65
Translated Electrical Safety and Emission Information
1Radiostörning EN55022 Klass A, FCC Par t 15 Klass A
2ImmunitetEN55024
3ElsäkerhetEN60950, UL60950, FCC Part 68
4Använd endast medföljande kr aftaggregat till DSL konverteraren.
5Varning: Nätkabeln används som strömbrytare för att koppla från strömmen, dra ur
6Fara För Blixtnedslag
7Blockera inte luftventilerna.
8Koppla inte telefonledning till signalkontakten.9Driftstemperatur: Denna produkt är konstruerad för rumstemperatur ej överstigande
Standarder: Denna produkt uppfyller följande standarder.
Säkerhet
AT-MC602 kan installeras fristående eller monterad i AT-MCR12 enheten. I det senare
fallet behöver AT-MC602 inte kraf tagg reg ate t.
nätkabeln.
Fara: ARBETA EJ på utrustningen eller kablarna vid ÅSKVÄDER.
40 grader Celsius.
10Alla Länder: Installera produkten i enl igh e t med lok ala oc h statlig a bestä mme lse r för
elektrisk utrus tning.
65