Copyright 2001 Allied Telesyn International Corp.
960 Stewart Drive, Suite B, Sunnyvale CA 94085 USA
All rights reserved. No part of this publication may be reproduced without prior
written permission from Allied Telesyn International Corp.
Ethernet is a registered trademark of Xerox Corporation. All other product names,
company names, logos or other designations mentioned herein are trademarks or
registered trademarks of their respective owners.
Allied Telesyn International Corp. reserves the right to make changes in specifications
and other information contained in this document without prior written notice. The
information provided herein is subject to change without notice. In no event shall
Allied Telesyn International Corp. be liable for any incidental, special, indirect, or
consequential damages whatsoever, including but not limited to lost profits, arising out
of or related to this manual or the information contained herein, even if Allied Telesyn
International Corp. has been advised of, known, or should have known, the possibility of
such damages.
Page 3
Safety Warnings
Standards: This product meets the following standards.
DECLARATION OF CONFORMITY
Manufacture Name:Allied Telesyn International Corp.
Manufacture Address:960 Stewart Drive, Suite B
Manufacture Telephone:408-730-0950
Declares that the product:Fast Ethernet Switches
Model Numbers:AT-FS211, AT-FS212, AT-FS212/1,
This product complies with FCC Part 15B, Class B Limits:
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device must not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class B
digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with instructions, may cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on. The
user is encouraged to try to correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes and modifications not expressly approved by the manufacturer or registrant of
this equipment can void your authority to operate this equipment under Federal
Communications Commission rules.
This Class B digital apparatus meets all requirements of the Canadian InterferenceCausing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur
le matériel brouilleur du Canada.
RFI EmissionEN55022 Class B
Warning: In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
ImmunityEN55024
$ 1
$ 2
$ 3
iii
Page 4
Safety Wa rnings
Warning: This product requires shielded cables to comply with emission and immunity
standards. If it is used with unshielded cables, the user may be required to take measures
to correct the interference problem at their own expense.
Electrical SafetyEN60950 (TUV), UL1950 (UL/cUL)
LaserEN60825
Warning Class 1 Laser product. (AT-FS212/x models)
Warning Do not stare into the Laser beam.
At time of installation, the Fiber Optic Lasers comply with FDA Radiation Performance
Standard 21CFR Subchapter J, applicable at date of manufacture.
This is a “CLASS 1 LED PRODUCT” (AT-FS21x models)
Important: Appendix B contains translated safety statements for installing this
equipment. When you see the
your language.
Wichtig: Anhang B enthält übersetzte Sicherheitshinweise für die Installation dieses
Geräts. Wenn Sie
in Ihrer Sprache nach.
Vigtigt: Tillæg B indeholder oversatte sikkerhedsadvarsler, der vedrører installation af
dette udstyr. Når De ser symbolet
sikkerhedsadvarsler i Deres eget sprog.
Belangrijk: Appendix B bevat vertaalde veiligheidsopmerkingen voor het installeren van
deze apparatuur. Wanneer u de
veiligheidsinstructies in uw taal.
Important: L'annexe B contient les instructions de sécurité relatives à l'installation d e cet
équipement. Lorsque vous voyez le symbole
la traduction de ces instructions dans votre langue.
Tärkeää: Liite B sisältää tämän laitteen asentamiseen liittyvät käännetyt turvaohjeet.
Kun näet
Importante: l’Appendice B contiene avvisi di sicurezza tradotti per l’installazione di
questa apparecchiatura. Il simbolo
sicurezza nella propria lingua.
Viktig: Tillegg B inneholder oversatt sikkerhetsinformasjon for installering av dette
utstyret. Når du ser
sikkerhetsinformasjonen på ønsket språk.
Importante: O Anexo B contém advertências de segurança traduzidas para instalar este
equipamento. Quando vir o símbolo
idioma no Anexo B.
Importante: El Apéndice B contiene mensajes de seguridad traducidos para la
instalación de este equipo. Cuando vea el símbolo
mensaje de seguridad traducido a su idioma.
Obs! Bilaga B innehåller översatta säkerhetsmeddelanden avseende installationen av
denna utrustning. När du ser
säkerhetsmeddelandet på ditt språk.
$ 4
$ 6
$ 7
$ 8
$ 9
$
, go to Appendix B for the translated safety statement in
$
sehen, schlagen Sie in Anhang B den übersetzten Sicherheitshinweis
$
, skal De slå op i tillæg B og finde de oversatte
$
ziet, raadpleeg Appendix B voor vertaalde
$
, reportez-vous à l'annexe B pour consulter
$
-symbolin, katso käännettyä turvaohjetta liitteestä B.
$
, indica di consultare l’Appendice B per l’avviso di
$
, åpner du til Tillegg B for å finne den oversatte
$
, leia a advertência de segurança traduzida no seu
$
, vaya al Apéndice B para ver el
$
, skall du gå till Bilaga B för att läsa det översatta
This installation guide contains instructions on how to wall-mount the
AT-FS21x and the AT-FS212/x Series Fast Ethernet Switches and how to
connect the units to your network.
Where to Find Web-based Guides
The Allied Telesyn web site at www.alliedtelesyn.com provides you with an
easy way to access the most recent documentation, software, and technical
information for all of our products. For product guides, you can go directly to
the following web page: www.alliedtelesyn.com/support/prd_libs.htm.
Document Conventions
This guide uses several conventions that you should become familiar with
before you begin to install the product.
Note
A note provides additional information.
Caution
A caution indicates that performing or omitting a specific action may
result in equipment damage or loss of data.
Warning
A warning indicates that performing or omitting a specific action may
result in bodily injury.
vii
Page 8
Welcome to Allied Telesyn
Contacting Allied Telesyn
You can contact Allied Teleysn technical support online or by telephone, fax,
or e-mail.
Online Support
You can request technical support online by filling out the Online Technical
Support Form at www.alliedtelesyn.com/support/supportf.asp or by
accessing the Technical Support Knowledge Base from Allied Telesyn’s North
American web site. You can use the Knowledge Base to submit questions to
our technical support staff and review answers to previously asked questions.
Technical and Fax Support
For technical support via fax, please fill out the “Technical Support Fax
Order” on page 33 and send it to the appropriate location listed below.
Americas
United States, Canada, Mexico,
Central America, South America
Tel:1 (800) 428-4835, option 4
Fax:1 (425) 481-3790
Asia
Singapore, Taiwan, Thailand, Malaysia,
Indonesia, Korea, Philippines, China,
India, Hong Kong
Tel:(+65) 3815-612
Fax:(+65) 3833-830
Australia
Australia, New Zealand
Tel:1 (800) 000-880
Fax:(+61) 2-9438-4966
France
France, Belgium, Luxembourg,
The Netherlands, Middle East, Africa
Tel:(+33) 1-60-92-15-25
Fax:(+33) 1-69-28-37-49
Germany
Germany, Switzerland, Austria, Eastern
Europe
Tel:(+49) 30-435-900-126
Fax:(+49) 30-435-70-650
Italy
Italy, Spain, Portugal, Greece, Turkey,
Israe
l
Tel:(+39) 02-41-30-41
Fax:(+39) 02-41-30-42-00
Japan
Tel:(+81) 3-3443-5640
Fax:(+81) 3-3443-2443
United Kingdom
United Kingdom, Denmark, Norway,
Sweden, Finland
Tel:(+44) 1-235-442500
Fax:(+44) 1-235-442680
viii
Page 9
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
Technical Support E-mail Addresses
United States and Canada
TS1@alliedtelesyn.com
Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands
latin_america@alliedtelesyn.com
Europe
support_europe@alliedtelesyn.com
Returning Products
Products for return or repair must first be assigned a Return Materials
Authorization (RMA) number. A product sent to Allied Telesyn without a
RMA number will be returned to the sender at the sender’s expense.
To obtain an RMA number, contact Allied Telesyn’s Technical Support at one
the following locations:
Tel: international code + 425-481-3852
Fax: international code + 425-481-3895
Mexico
Toll-free: 800-424-5012, ext 3852
Fax: international code + 425-481-3895
Australia
Toll-free: 1-800-000-880
Fax: +61-2-9438-4966
Europe, Africa, and the Middle East
Tel: +44-1793-501401
Fax: +44-1793-431099
Puerto Rico
Tel: 1-800-424-5012, ext 3852 or
1-800-424-4284, ext 385
Asia and Southeast Asia
Tel: +65-381-5612
Fax: +65-383-3830
New Zealand
Toll-free: 0800-45-5782
2
FTP Server
If you need management software for an Allied Telesyn device and you know
the file name of the software, you can download the software by connecting
directly to our FTP server at ftp.alliedtelesyn.com. At login, enter
‘anonymous’ as the user name and your e-mail address for the password.
ix
Page 10
Welcome to Allied Telesyn
For Sales or Corporate Information
You can contact Allied Telesyn for sales or corporate information at one of the
locations below:
Allied Telesyn International Corp.
19800 North Creek Parkway, Suite 200
Bothell, WA 98011
Tel: 1 (425) 487-8880
Fax: 1 (425) 489-9191
Allied Telesyn International Corp.
960 Stewart Drive, Suite B
Sunnyvale, CA 94085
Tel: 1 (800) 424-4284 (US and Canada)
Fax: 1 (408) 736-0100
Tell Us What You Think
If you have any comments or suggestions on how we might improve this or
other Allied Telesyn documents, please fill out the Send Us Feedback Form at
www.alliedtelesyn.com/contact/feedbackf.asp.
x
Page 11
Chapter 1
Overview
The AT-FS21x and AT-FS212/x Series Fast Ethernet Switches feature the
following models:
These switches are designed to interconnect LAN devices and subnetworks
over large distances. These dual-port switches can also improve the
performance of your network by dividing it into smaller, more manageable
segments.
The AT-FS21x and AT-FS212/x Series Switches have a 10/100Base-TX
twisted pair port and a 100Base-FX fiber optic port. The twisted pair port has
an RJ-45 connector and a maximum operating distance of 100 meters (328
feet). This port operates at 10/100 Mbps and features half- and full-duplex
operation.
The fiber optic port has a FJ, LC, MT-RJ, SC, ST, or VF-45 connector and a
maximum operating distance 2 kilometers (1.2 miles) to 100 kilometers
(62 miles), depending on the model. This port operates at 100 Mbps and
features full-duplex operation.
1
Page 12
Overview
These switches are easy to install and do not require software configuration or
management. Figure 1 illustrates an AT-FS21x Series Switch.
Mounting
Bracket Screws
4
1
2
S
F
-
T
A
Fast Ethernet Switch
LEDs
X
F
R
W
P
X
T
10Base-T/
100Base-TX
C
D
V
.3
3
Cable Hook
DC Connector10/100Base-TX Port
Figure 1 AT-FS21x Series Switch (Model AT-FS214)
Table 1 lists the operating distances for the AT-FS21x and AT-FS212/x Series
Switches.
Table 1 Maximum Operating Distance
Model10/100Base-TX
ConnectorMaximum
Operating Distance
1
100Base-FX
ConnectorMaximum
Operating Distance
2
AT-FS211RJ-45100 m (328 ft)ST2 km (1.2 mi)
AT-FS212RJ-45100 m (328 ft)SC2 km (1.2 mi)
AT-FS212/1RJ-45100 m (328 ft)SC15 km (9.3 mi)
AT-FS212/2RJ-45100 m (328 ft)SC40 km (24.8 mi)
AT-FS212/3RJ-45100 m (328 ft)SC70 km (43.4 mi)
AT-FS212/4RJ-45100 m (328 ft)SC100 km (62 mi)
AT-FS214RJ-45100 m (328 ft)MT-RJ2 km (1.2 mi)
AT-FS215RJ-45100 m (328 ft)VF-452 km (1.2 mi)
AT-FS216RJ-45100 m (328 ft)LC2 km (1.2 mi)
AT-FS217RJ-45100 m (328 ft)FJ2 km (1.2 mi)
1. Maximum distance can only be obtained when the UTP/STP cabling is installed and verified to the TIA/EIA 568A
Commercial Building Telecommunications Cabling Standard.
2. Maximum distance for 100 Mbps Optical Datalinks are dependent on the following factors: type of optical fiber,
duplex mode of both end-nodes, and maximum optical loss budget for each of the optical fiber at the operating
optical wavelength.
2
Page 13
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
Key Features
The switches have the following key features:
❑LEDs for unit and port status
❑Wall-mountable chassis
❑Auto MDI/MDI-X
❑External AC/DC power adapters (North America, Continental, or
Europe)
❑Full- or half-duplex mode operation on the twisted pair port
❑Full-duplex operation on the fiber optic port
❑FJ, LC, MT-RJ, SC, ST, or VF-45 fiber optic connector
❑Data packet forwarding and filtering at full wire speed
❑Store and forward switching mode
❑Automatic address learning and aging
❑IEEE 802.3u compliant auto-negotiation on the twisted pair port
Switch Performance
The switches perform at:
❑148,800 pps for 100 Mbps and 14,880 pps for 10 Mbps with full wire
speed forwarding and filtering
❑200 Mbps maximum throughput in 100 Mbps, full-duplex mode
❑20 Mbps maximum throughput in 10 Mbps, full-duplex mode
Table 2 AT-FS21x and AT-FS212/x Series Switch LEDs
LEDColorDescription
PWRGreenPower is applied.
FXGreen
Blinking
TXGreen
Blinking
100MGreen
OFF
A link has been established on the fiber optic port
Activity has been detect ed on the fiber optic port.
A link has been establ ished on the twisted pair port
Activity has been detected on the twisted pair port.
The twisted pair port is operating at 100 Mbps.
The twisted pair port is operating at 10 Mbps.
External Pow er Adapter
The power adapter supplies 3.3V DC to the switch. Allied Telesyn supplies an
approved safety compliant AC power adapter for 3.3 V/1.5 A versions with an
unregulated output of 3.3V DC.
Auto MDI/MDI-X
An RJ-45 twisted pair port on a 10 Mbps or 100 Mbps Ethernet network
device can have one of two possible wiring configurations: MDI or MDI-X. The
RJ-45 port on a PC, router, or bridge is typically wired as MDI, while the
twisted pair port on a switch or hub is usually MDI-X.
To connect two 10 Mbps or 100 Mbps network devices together that have
dissimilar port wiring configurations, such as MDI to MDI-X, you use a
straight-through twisted pair cable. To connect two network devices that have
the same wiring configuration, such as MDI to MDI, you use a crossover cable.
The AT-FS21x and AT-FS212/x Series Switches feature automatic MDI/
MDI-X. Each port automatically determines the configuration of the port on
the device to which it is connected and then configures itself appropriately.
For example, if a port on a switch is connected to a port on a bridge, which is
typically wired as MDI, the port on the switch automatically configures itself
as MDI-X. This eliminated the need for using a crossover cable with these
switches.
4
Page 15
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
Functional Description
Frame Process ing
The switches support store and forward switching at Fast Ethernet full-wire
speed in 10 or 100 Mbps, half- or full-duplex mode. Packets entering each port
are stored in buffers. After the full packet is received, it is forwarded or
discarded depending on its destination address and error status. This ensures
that only error-free data packets destined for another segment will be
transferred across the switch, reducing network load. For example, if the
packet entering from Port 1 is destined for an end station on Port 2, it will be
forwarded if the Frame Check Sequence (FCS) is valid. If the packet from Port
1 is destined for an end station also attached to Port 1, then the packet is
discarded.
The switch will discard CRC error, misaligned, runt, and under-sized/oversized packets. When the packet has dribble bits at the end, the switch will
truncate to octet boundary and check for a good FCS before forwarding.
Address Recognition and Filtering
Up to 4,000 MAC addresses can be stored in the MAC address table. The
switch will learn all new addresses in real-time after power-up with its
address self-learning mechanism. If the source address of an incoming packet
is not found in the address table, the switch waits until the end of the packet
to check for good CRC and then updates its MAC address table. Because the
switch has Automatic Address Aging, if a source address entry in the table is
not updated within five minutes, the entry is deleted from the table. The
switch forwards multicast, broadcast, and unicast packets when the MAC
address table size is exceeded.
5
Page 16
Overview
Network Topologies
Figure 2 illustrates a topology using one AT-FS214 switch to interconnect two
small networks of stackable hubs. Network 1 has an AT-FH812u with an
AT-FH807u switching module connected to the 100Base-FX port on the
AT-FS214. Network 2 has an AT-3624TR hub connected to the 10/100Base-TX
port on the AT-FS214.
Network 1
Network 2
AT-FH812u
with an
AT-FH807u
module
AT-FH812u
AT-FH812u
Twisted Pair
Fiber Optic
AT-FS214
AT-FS214
Fast Ethernet Switch
FX
PWR
TX
100MLK/AT
Figure 2 Network Topology
AT-3624TR
AT-3624TR
AT-3624TR
6
Page 17
Chapter 2
Installing the Switch
Verifying the Package Contents
Make sure the following items are included in your package. If any item is
missing or damaged, contact your Allied Telesyn sales representative for
assistance.
❑One AT-FS21x or AT-FS212/x Series Fast Ethernet Switch
❑External power adapter (North America, Continental Europe, or
United Kingdom)
❑2 Phillips-head screws
❑2 plastic anchors
❑Cable tie
❑This installation guide
❑Warranty card
Planning the Installation
Be sure to observe the following guidelines when planning the installation of
your switch.
❑The end-node connected to the fiber optic port on the switch must be
able to operate at 100 Mbps and full-duplex mode.
❑The end-node connected to the twisted pair port can operate at either
10 Mbps or 100 Mbps, half- or full-duplex mode.
❑The twisted pair cabling must be kept away from sources of electrical
noise, such as radios, transmitters, power lines, broadband amplifiers,
electrical motor, and fluorescent fixtures.
❑Refer to the following tables for the cabling specifications for the 10/
100Base-TX and 100Base-FX ports.
7
Page 18
Installing the S witch
Table 3 10/100Base-TX Twisted Pair Port Cabling Specifications
Operating ModeTwisted Pair Cable
Maximum Operating
Distance
10Base-TShielded or unshielded Category 3 or be tter100 m (328 ft)
100Base-TXShielded or unshielded Category 5 or better100 m (328 ft)7
Table 4 100Base-FX Fiber Optic Port Cabling Specificatio ns (Full-duplex)
ModelFiber Optic Cable
AT-FS21150/125 or 62.5/125
Maximum
Operating Di stance
2 km (1.2 mi)13 dB at 1310 nm
Maximum Allowable
Loss Budget
micron multimode
AT-FS21250/125 or 62.5/125
2 km (1.2 mi)13 dB at 1310 nm
micron multimode
AT-FS212/19/125 micron
15 km (9.3 mi)16 dB at 1310 nm
single-mode
AT-FS212/29/125 micron
40 km (24.8 mi)30 dB at 1310 nm
single-mode
AT-FS212/39/125 micron
70 km (43.4 mi)33 dB at 1310 nm
single-mode
AT-FS212/4
1
9/125 micron
100 km (62 mi)34 dB at 1550 nm
single-mode
AT-FS21450/125 or 62.5/125
2 km (1.2 mi)13 dB at 1310 nm
micron multimode
AT-FS21550/125 or 62.5/125
2 km (1.2 mi)13 dB at 1310 nm
micron multimode
AT-FS21650/125 or 62.5/125
2 km (1.2 mi)13 dB at 1310 nm
micron multimode
AT-FS21750/125 or 62.5/125
2 km (1.2 mi)13 dB at 1310 nm
micron multimode
1. The cable must be non-dispersion-shifted, dispersion-shifted, or non-zero dispersion-shifted single-mode fiber
optic cable.
8
Page 19
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
Note
Refer to page 18 for additional fiber optic port specifications.
Selecting a Site
Be sure to observe the following requirements when choosing a site for your
switch.
❑Select a site that is dust-free and moisture-free.
❑Be sure that the site will allow you to easily access the fiber optic and
twisted pair cables and the power cord.
❑Use dedicated power circuits or power conditioners to supply reliable
power to the device.
Reviewing Safety Guidelines
Please review the following safety guidelines before you begin to install the
media converter.
Warning
Class 1 laser device. $ 7
Warning
Do not stare into the laser beam. $ 8
Warning
Electric Shock Hazard: To prevent electric shock, do not remove the
cover. There are no user-serviceable parts inside. The unit contains
hazardous voltages and should only be opened by a trained and
qualified technician. $ 9
Warning
Lightning Danger: Do not work on this equipment or cables during
periods of lightning activity. $ 11
Caution
Power cord is used as a disconnection device: To de-energize
equipment, disconnect the power cord. $ 12
9
Page 20
Installing the S witch
Caution
Pluggable Equipment: The socket outlet should be installed near the
equipment and should be easily accessible. $ 13
Caution
Air vents: The air vents must not be blocked on the unit and must have
free access to the room ambient air for cooling. $ 14
Caution
Operating Temperature: This product is designed for a maximum
ambient temperature of 40°C. $ 16
Caution
All Countries: Install this product in accordance with local and
National Electric Codes. $ 17
Installing the Switch
To install an AT-FS21x or AT-FS212/x Series Switch, perform the following
procedure:
1.Remove all equipment from the package and store the packaging in a safe
place.
2.Remove the mounting bracket screws, as shown in Figure 3. These screws
are marked with black circles.
h
itc
w
t S
e
n
r
e
th
AT-FS214
t E
s
a
F
PWR
FX
TX
10Base-T/
100Base-TX
C
D
V
.3
3
Figure 3 Removing the Moun ting Bracket Screws
10
Page 21
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
3.Gently slide the bracket off the switch. See Figure 4.
Figure 4 Sliding the Wall-mounting Bracket of f t he Switch
Note
For drywall installation, drill two 3/16-inch holes, insert the plastic
anchors and tap flush.
4.Position the wall-mounting bracket on the wall and, using two
Phillips-head screws (provided), secure the bracket to the wall. See Figure
5.
Figure 5 Attaching the Wall-mounting Bracket to the Wall
11
Page 22
Installing the S witch
Note
The switch can be mounted either vertically or horizontally.
5.Using the flanges under the fiber optic port as a guide, slide the switch
into the mounting bracket. Refer to Figure 6.
FlangeFlange
AT-FS214
Fast Ethernet S
witch
F
X
P
W
R
T
X
L
K
/
A
T
1
0
0
M
Figure 6 Sliding the Switch Over the Wall-mounting Bracket
6.Secure the switch to the wall-mounting bracket using the screws removed
in Step 2.
7.If your switch is shipped with Universal Voltage Power Adapter (2-cable),
do the following:
a. Connect the AC power cord to the Universal Voltage Power Adapter.
b. Plug the DC cable into the DC receptacle on the switch.
c. Plug the AC power cord on the adapter to a power outlet.
12
Page 23
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
8.If your switch is shipped with an Single Voltage Power Adapter (single
cable), do the following:
a. Plug the DC cable into the DC receptacle on the switch.
b. Plug the AC power cord to a power outlet.
Note
To prevent the DC power cable from being inadvertently pulled out of
the switch, use the cable tie supplied with the unit to secure the DC
power cable to the cable hook located next to the DC connector.
9.Verify that the PWR LED on the switch is green. If the LED is OFF, refer
to “Troubleshooting” on page 15.
10. Remove the dust cover from the 100Base-FX fiber optic port and connect
the fiber optic cable.
11. Connect the twisted pair cable to the 10/100Base-TX port.
12. Power ON the end-nodes. The TX and FX LEDs should be green. If the
LEDs are OFF, refer to “Troubleshooting” on page 15.
13. The switch is now ready for use.
Warranty Registration
When you finish installing the product, you should register your product by
completing the enclosed warranty card and sending it in. You can also fill out
the registration online at www.alliedtelesyn.com/support/warrantyf.asp.
13
Page 24
Page 25
Chapter 3
Troubleshooting
Follow the guidelines below to test and troubleshoot the installation in the
event a problem occurs.
If the PWR LED is OFF, do the following:
❑Make sure that the power adapter is securely connected to a power
source and the DC power cord on the adapter is securely connected to
the DC power connector on the switch.
❑Verify that the power outlet has power by connecting another device
to it.
❑Try connecting the switch to another power source.
❑Try using another power adapter.
If the TX LED for the twisted pair port is powered OFF, do the following:
❑Check that the end-node connected to the port is ON and is operating
properly.
❑Check that the twisted pair cable is securely connected to the twisted
pair port on the switch and on the end-node.
❑Make sure that the twisted pair cable does not exceed 100 meters (328
feet).
❑If the end-node is operating at 100 Mbps, verify that you are using
Category 5 or better twisted pair cabling.
If the FX LED for the fiber optic port is powered OFF, do the following:
❑Verify that the end-node connected to the port is ON and is operating
properly.
❑Check that the fiber optic cable is securely connected to the fiber optic
port on the switch and on the end-node.
15
Page 26
Troubleshooting
❑Check to be sure that the end-node connected to the port is operating
at 100 Mbps.
❑Make sure that the fiber optic port on the end-node is operating in
full-duplex mode.
❑Make sure that the cable connected to the fiber optic receiver port on
the switch is connected to the transmitter port on the remote end-node
and that the fiber optic transmitter port on the switch is connected to
the receiver port on the end-node.
❑Test the attenuation on the fiber cable to ensure that it does not
exceed acceptable values.
❑Verify that you are using the appropriate type of fiber optic cable and
that you have not exceeded the maximum operating distance. For
cable types and operating distances, refer to Table 4 on page 8.
❑Check that the operating specifications of the fiber optic port on the
end-node are compatible with the operating specifications of the fiber
optic port on the switch. Refer to page 18 for the fiber optic port
specifications.
If you are still experiencing problems after testing and troubleshooting the
installation, contact Allied Telesyn Technical Support for assistance. Refer to
“Contacting Allied Telesyn” on page viii or visit our web site at www.alliedtelesyn.com for support information.
16
Page 27
Appendix A
Technical Specifications
Specifications
Physical
Dimensions:90 mm x 24 mm x 70 mm
(3.54 in x 0.94 in x 2.76 in)
Weight:0.23 kg (0.5 lbs)
Temperature
Operating:0° to 40° C
Storage:-25° to 70° C
Relative Humidity:5% to 80% (non-condensing)
Operating Altitude:Up to 10,000 feet
Electrical and Mechanical Specifications
Standard:CE Compliant IEEE 802.3, IEEE 802.3u
Immunity:Conforms to EN500082-1 1997 immunity
standard
Safety:Conforms to all standards normally supported
by Allied Telesyn products including safety
standards UL 1950 (UL/cUL), TUV EN60950,
EN60825 CE Compliant
EMI/RFI:Meets all applicable requirements for emissions
including but not limited to FCC Class A,
EN55022 Class A
17
Page 28
Technical Specifications
Electrical Rating
Input Supply Voltage3.3V DC
Minimum Current Rating1.5A
Maximum Power
Consumption6W
Fiber Optic Port Specifications
The following tables list the specifications for the 100Base-FX fiber optic port.
AT-FS217
AT-FS212/ 19/125 SMF16.0019.50015 km (9.4 mi)
AT-FS212/29/125 SMF30.0035.00040 km (25 mi)
AT-FS212/ 39/125 SMF33.0035.0015 km
(9.3 mi)
AT-FS212/ 49/125 SMF34.0035.0040 km
(24.8 mi)
1. The recommended minimum range is stated in all cases where the maximum transmitter output power exceeds
the receivers saturation level. This is to prevent blinding or burning out of the optical receiver on the far end-node.
70 km
(43.4 mi)
100 km
(62 mi)
19
Page 30
Technical Specifications
Table 8 Fiber Optic Loss Specification (Benchmarks)
Important: This appendix contains multiple-language translations for the
safety statements in this guide.
Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch
enthaltenen Sicherheitshinweise in mehreren Sprachen.
Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af
sikkerhedsadvarslerne i denne håndbog.
Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de
veiligheidsopmerkingen in deze gids.
Important: Cette annexe contient la traduction en plusieurs langues des
instructions de sécurité figurant dans ce guide.
Tärkeää: Tämä liite sisältää tässä oppaassa esiintyvät turvaohjeet usealla
kielellä.
Importante: questa appendice contiene traduzioni in più lingue degli avvisi
di sicurezza di questa guida.
Viktig: Dette tillegget inneholder oversettelser til flere språk av
sikkerhetsinformasjonen i denne veiledningen.
Importante: Este anexo contém traduções em vários idiomas das
advertências de segurança neste guia.
Importante: Este apéndice contiene traducciones en múltiples idiomas de los
mensajes de seguridad incluidos en esta guía.
Obs! Denna bilaga innehåller flerspråkiga översättningar av
säkerhetsmeddelandena i denna handledning.
21
Page 32
Electrical Safety and Ins tallation Requiremen t s
Standards: This product meets the following standards.
U.S. Federal Communications Commission
DECLARATION OF CONFORMITY
Manufacture Name:Allied Telesyn International Corp.
Manufacture Address:960 Stewart Drive, Suite B
Manufacture Telephone:408-730-0950
Declares that the product:Fast Ethernet Switches
Model Numbers:AT-FS211, AT-FS212, AT-FS212/1,
This product complies with FCC Part 15B, Class B Limits:
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device must not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class B
digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with instructions, may cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on. The
user is encouraged to try to correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes and modifications not expressly approved by the manufacturer or registrant of
this equipment can void your authority to operate this equipment under Federal
Communications Commission rules.
This Class B digital apparatus meets all requirements of the Canadian InterferenceCausing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur
le matériel brouilleur du Canada.
$ 1RFI EmissionEN55022 Class B
$ 2Warning: In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
$ 3ImmunityEN55024
$ 4Warning: This product requires shielded cables to comply with emission and
immunity standards. If it is used with unshielded cables, the user may be required
to take measures to correct the interference problem at their own expense.
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
$ 7Warning Class 1 Laser product. (AT-FS212/x models)
$ 8Warning Do not stare into the Laser beam.
At time of installation, the Fiber Optic Lasers comply with FDA Radiation
Performance Standard 21CFR Subchapter J, applicable at date of manufacture.
$ 9ELECTRICAL NOTICES
Warning: ELECTRIC SHOCK HAZARD
To prevent ELECTRIC shock, do not remove the cover. No userserviceable parts inside. This unit contains HAZARDOUS VOLTAGES
and should only be opened by a trained and qualified technician. To avoid
the possibility of ELECTRIC SHOCK, disconnect electric power to the
product before connecting or disconnecting the LAN cables.
$ 10This is a “CLASS 1 LED PRODUCT” (AT-FS21x models)
$ 11LIGHTNING DANGER
Danger: DO NOT WORK on equipment or CABLES during periods of LIGHTNING
ACTIVITY.
$12Caution: Power cord is used as a disconnection device. to de-energize
equipment, disconnect the power cord.
$ 13Pluggable equipment, the socket outlet shall be installed near the
equipment and shall be easily accessible.
$ 14Caution: Air vents must not be blocked and must have free access to the room
ambient air for cooling.
$ 15Power to the hub must be sourced only from the adapter.
USA/CANADA
Use a UL Listed/CSA Certified AC adapter of DC 3.3V, 1.5A.
EUROPE - EU
Use TÜV licensed AC adapter of DC 3.3V, 1.5A.
UK
Use a UK Safety Approved AC adapter of DC 3.3V, minimum 1.5A.
$ 16Operating Temperature: This product is designed for a maximum ambient
temperature of 40 degrees C.
$ 17All Countries: Install product in accordance with local and National Electrical
Codes.
Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen.
$ 1HochfrequenzstörungEN55022 Klasse B
$ 2Warnung: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen
hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen
ergreifen.
$ 3StörsicherheitEN55024
$ 4Achtung: Für dieses Produkt sind abgeschirmte Kabel erforderlich, damit den
Richtlinien für Emission und Interferenzschutz entsprochen wird. Falls das Produkt
mit nicht abgeschirmten Kabeln verwendet wird, können weitergehende
Maßnahmen für die Korrektur von Interferenzproblemen auf Kosten des Benutzers
notwendig werden.
Electrical Safety and Ins tallation Requiremen t s
SICHERHEIT
$ 7Warnung Laserprodukt der Klasse 1.
$ 8Warnung Nicht direkt in den Strahl blicken.
$ 9Achtung: GEFÄHRLICHE SPANNUNG
Das Gehäuse nicht öffnen. Das Gerät enthält keine vom Benutzer
wartbaren Teile. Das Gerät steht unter Hochspannung und darf nur von
qualifiziertem technischem Personal geöffnet werden. Vor Anschluß der
LAN-Kabel, Gerät vom Netz trennen.
$ 10Das ist ein “LED Produkt der Klasse 1”
$ 11GEFAHR DURCH BLITZSCHLAG
Gefahr: Keine Arbeiten am Gerät oder an den Kabeln während eines Gewitters
ausführen.
$ 12Vorsicht: Das netzkabel dient zum trennen der stromversorgung. Zur trennung
vom netz, kabel aus der steckdose ziehen.
$ 13Steckbares Gerät: Die Anschlußbuchse sollte in der Nähe der Einrichtung
angebracht werden und leicht zugänglich sein."
$ 14Vorsicht
Die Entlüftungsöffnungen dürfen nicht versperrt sein und müssen zum
Kühlen freien Zugang zur Raumluft haben
.
$ 15Der Buchse darf nur aus dem Adapter Strom zugeführt werden.
EUROPE - EU
Gebrauchen Sie einen von TÜV zugelassenen Wechselstromadapter für Gleichstrom
3.3V, 1.5A.
$ 16Betriebstemperatur
Dieses Produkt wurde für den Betrieb in einer Umgebungstemperatur von nicht
mehr als 40° C entworfen.
$17Alle Länder: Installation muß örtlichen und nationalen elektrischen Vorschriften
entsprechen.
Standarder: Dette produkt tilfredsstiller de følgende standarder.
$ 1Radiofrekvens
forstyrrelsesemissionEN55022 Klasse B
$ 2Advarsel: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse.
Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige
foranstaltninger.
$ 3Immunitet EN55024
$ 4Advarsel: Dette produkt skal bruges med afskærmede kabler for at overholde
bestemmelserne vedrørende udstråling og støjimmunitet. Hvis det bruges med
uafskærmede kabler, kan det blive påkrævet af brugeren at korrigere
interferensproblemer for egen regning.
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
$ 9ELEKTRISKE FORHOLDSREGLER
Advarsel: RISIKO FOR ELEKTRISK STØD
For at forebygge ELEKTRISK stød, undlad at åbne apparatet. Der er
ingen indre dele, der kan repareres af brugeren. Denne enhed indeholder
LIVSFARLIGE STRØMSPÆNDINGER og bør kun åbnes af en uddannet
og kvalificeret tekniker. For at undgå risiko for ELEKTRISK STØD,
afbrydes den elektriske strøm til produktet, før LAN-kablerne monteres
eller afmonteres.
$ 10Dette er et “PRODUKT UNDER KLASSE 1 LED”
$ 11FARE UNDER UVEJR
Fare: UNDLAD at arbejde på udstyr eller KABLER i perioder med
LYNAKTIVITET.
$ 12Waarschuwing: Het toestel wordt uitgeschakeld door de stroomkabel te
ontkoppelen. Om het toestel stroomloos te maken: de stroomkabel ontkoppelen.
$ 13Aan te sluiten apparatuur, de contactdoos wordt in de nabijheid van de apparatuur
geïnstalleerd en is gemakkelijk te bereiken."
$ 14Opgelet: De ventilatiegaten mogen niet worden gesperd en moeten de
omgevingslucht ongehinderd toelaten voor afkoeling
$ 15Strømforsyningen til apparatet må udelukkende tages fra
tilpasningstransformatoren.
EUROPE - EU
Brug kun TÜV godkendt vekselstrømstransformator på 3.3V jævnstrøm, 1.5A.
$ 16Betjeningstemperatur: Dette apparat er konstrueret til en omgivende temperatur
på maksimum 40 grader C.
$ 17Alle Lande: Installation af produktet skal ske i overensstemmelse med lokal og
national lovgivning for elektriske installationer.
Eisen: Dit product voldoet aan de volgende eisen.
$ 1RFI EmissieEN55022 Klasse B
$ 2Waarschuwing: Binnenshuis kan dit product radiostoring veroorzaken, in welk
geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen.
$ 3ImmuniteitEN55024
$ 4Waarschuwing: Om te voldoen aan de emissie- en immuniteitsnormen dient dit
apparaat te zijn voorzien van afgeschermde kabels. Als het met niet-afgeschermde
kabels wordt gebruikt, kan het zijn dat de gebruiker maatregelen moet treffen om
interferentieproblemen voor eigen rekening op te lossen.
Advarsel: RISIKO FOR ELEKTRISK STØD For at forebygge
ELEKTRISK stød, undlad at åbne apparatet. Der er ingen indre dele, der
kan repareres af brugeren. Denne enhed indeholder LIVSFARLIGE
25
Page 36
Electrical Safety and Ins tallation Requiremen t s
STRØMSPÆNDINGER og bør kun åbnes af en uddannet og kvalificeret
tekniker. For at undgå risiko for ELEKTRISK STØD, afbrydes den
elektriske strøm til produktet, før LAN-kablerne monteres eller
afmonteres.
$ 10Dit is een “KLASSE 1 LED-PRODUKT”
$ 11GEVAAR VOOR BLIKSEMINSLAG
Gevaar: NIET aan toestellen of KABELS WERKEN bij BLIKSEM.
$ 12Attention: Le cordon d’alimentation sert de mise hors circuit. Pour couper
l’alimentation du matériel, débrancher le cordon.
$ 13Equipement pour branchement electrique, la prise de sortie doit être placée près de
l’équipement et facilement accessible".
$ 14Attention: Ne pas bloquer les fentes d’aération, ceci empêcherait l’air ambiant de
circuler librement pour le refroidissement
$ 15Stroom mag alleen via de adapter naar het apparaat toegevoerd worden.
EUROPE - EU
Gebruik een door TÜV gekeurde wisselstroomadapter van 3.3 Volt gelijkstroom, 1.5
milliampères.
$ 16Bedrijfstemperatuur: De omgevingstemperatuur voor dit produkt mag niet meer
bedragen dan 40 graden Celsius.
$ 17Alle Landen: het toestel installeren overeenkomstig de lokale en nationale
elektrische voorschriften.
Normes: ce produit est conforme aux normes de suivantes.
$ 1Emission d'interférences
radioélectriquesEN55022 Classe
B
$2Mise En Garde: dans un environnement domestique, ce produit peut provoquer des
interférences radioélectriques. Auquel cas, l'utilisateur devra prendre les mesures
adéquates.
$ 3ImmunitéEN55024
$ 4Avertissement : Il faut utiliser des câbles blindés pour ce produit afin de respecter
les normes d’émission et d’immunité. Si l’utilisateur choisit d’utiliser des câbles non
blindés, il sera peut-être contraint de prendre les mesures nécessaires pour corriger
les problèmes d’interférences, ainsi que d’assumer le coût correspondant.
$ 8Attention Ne pas fixer le faisceau des yeux.
$ 9INFORMATION SUR LES RISQUES ÉLECTRIQUES
L
AVERTISSEMEN
Pour éviter toute ÉLECTROCUTION, ne pas ôter le revêtement
protecteur du matériel. Ce matériel ne contient aucun élément réparable
par l’utilisateur. Il comprend des TENSIONS DANGEREUSES et ne doit
: DANGER D’ÉLECTROCUTION
26
Page 37
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
être ouvert que par un technicien dûment qualifié. Pour éviter tout risque
d’ÉLECTROCUTION, débrancher le matériel avant de connecter ou de
déconnecter les câbles LAN.
$ 10Ce mat‚riel est un “PRODUIT A DIODE LECTROLUMINESCENTE DE CLASSE 1”
$ 11DANGER DE FOUDRE
Danger: NE PAS MANIER le matériel ou les CÂBLES lors d'activité orageuse.
$ 12Attention: Le cordon d’alimentation sert de mise hors circuit. Pour couper
l’alimentation du matériel, débrancher le cordon.
$ 13EQUIPEMENT POUR BRANCHEMENT ELECTRIQUE, la prise de sortie doit être
placée près de l’équipement et facilement accessible".
$14Attention: Ne pas bloquer les fentes d’aération, ceci empêcherait l’air
ambiant de circuler librement pour le refroidissement.
$ 15L'alimentation du concentrateur doit être uniquement fournie par l'adaptateur.
EUROPE - EU
Utiliser un adaptateur secteur conforme TÜV de 3.3V, 1.5A en courant continu.
$ 16TEMPÉRATURE DE FONCTIONNEMENT
Ce matériel est capable de tolérer une température ambiante maximum de 40 degrés
Celsius.
$ 17POUR TOUS PAYS: Installer le matériel conformément aux normes électriques
nationales et locales.
Standardit: Tämä tuote on seuraavien standardien mukainen.
$ 1Radioaaltojen häirintäEN55022 Luokka B
$ 2Varoitus: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä
tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin
toimenpiteisiin.
$ 3KestävyysEN55024
$ 4Varoitus: Tämä tuote vaatii suojattuja kaapeleita toimiakseen emissio- ja
häiriönsietostandardien mukaisesti. Jos tuotetta käytetään ilman suojattuja
kaapeleita, käyttäjä voi joutua korjaamaan häirinnän aiheuttaman ongelman
omalla kustannuksellaan.
$ 8Variotus Älä katso säteeseen.
$ 9SÄHKÖÖN LIITTYVIÄ HUOMAUTUKSIA
VAROITUS: S ÄHKÖISKUVAARA Estääksesi SÄHKÖISKUN älä poista
kantta. Sisällä ei ole käyttäjän huollettavissa olevia osia. Tämä laite
sisältää VAARALLISIA JÄNNITTEITÄ ja sen voi avata vain koulutettu
ja pätevä teknikko. Välttääksesi SÄHKÖISKUN mahdollisuuden
katkaise sähkövirta tuotteeseen ennen kuin liität tai irrotat
paikallisverkon (LAN) kaapelit.
$ 10Tämä on “ENSIMMÄISEN LUOKAN VALODIODITUOTE”
27
Page 38
Electrical Safety and Ins tallation Requiremen t s
$ 11SALAMANISKUVAARA
ENGENVAARA: ÄLÄ TYÖSKENTELE laitteiden tai KAAPELEIDEN KANSSA
SALAMOINNIN AIKANA.
$ 12HUOMAUTUS: VIRTAJOHTOA KÄYTETÄÄN VIRRANKATKAISULAITTEENA.
VIRTA KATKAISTAAN irrottamalla virtajohto.
$ 13PISTORASIAAN KYTKETTÄVÄ LAITE; pistorasia on asennettava laitteen lähelle
ja siihen on oltava esteetön pääsy."
$ 14HUOMAUTUS: Ilmavaihtoreikiä ei pidä tukkia ja niillä täytyy olla vapaa yhteys
ympäröivään huoneilmaan, jotta ilmanvaihto tapahtuisi.
$ 15Tähtipisteeseen (hub) syötettävän virran pitää tulla ainoastaan sovittimesta.
EUROPE - EU
Käytä TÜV-lisenssillä valmistettua verkkosovitinta, jonka tasajännitteen
nimellisarvot ovat DC 3.3V, 1.5A (milliampeeria).
$ 16KÄYTTÖLÄMPÖTILA
Tämä tuote on suunniteltu ympäröivän ilman maksimilämpötilalle 40° C.
$ 17KAIKKI MAAT: Asenna tuote paikallisten ja kansallisten
sähköturvallisuusmääräysten mukaisesti.
Standard: Questo prodotto è conforme ai seguenti standard.
$ 1Emissione RFI (interferenza di
radiofrequenza) EN55022 Classe
B
$2Avvertenza: in ambiente domestico questo prodotto potrebbe causare radio
interferenza. In questo caso potrebbe richiedersi all'utente di prendere gli adeguati
provvedimenti.
$ 3ImmunitàEN55024
$ 4Avvertenza: questo prodotto, se utilizzato con cavi schermati, è conforme alle
norme sulle emissioni e sull’immunità. In caso di uso senza cavi schermati, l’utente
può dover adottare a proprie spese misure correttive contro le interferenze.
$ 8Avertenza Non fissare il raggio con gli occhi.
$ 9AVVERTENZE ELETTRICHE
ATTENZIONE: PERICOLO DI SCOSSE ELETTRICHE
Per evitare SCOSSE ELETTRICHE non asportare il coperchio. Le
componenti interne non sono riparabili dall’utente. Questa unità ha
TENSIONI PERICOLOSE e va aperta solamente da un tecnico
specializzato e qualificato. Per evitare ogni possibilità di SCOSSE
ELETTRICHE, interrompere l’alimentazione del dispositivo prima di
collegare o staccare i cavi LAN.
$ 10Questo è un “PRODOTTO CON LED DI CLASSE 1”
$ 11PERICOLO DI FULMINI
Pericolo: NON LAVORARE sul dispositivo o sui CAVI durante PRECIPITAZIONI
TEMPORALESCHE.
28
Page 39
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
$ 12Attenzione: Il cavo di alimentazione è usato come dispositivo di disattivazione. Per
togliere la corrente al dispositivo staccare il cavo di alimentazione.
$ 13APPARECCHIATURA COLLEGABILE, la presa va installata vicino all’apparecchio
per risultare facilmente accessibile".
$ 14ATTENZIONE: le prese d’aria non vanno ostruite e devono consentire il libero
ricircolo dell’aria ambiente per il raffreddamento.
$ 15Questo dispositivo deve essere alimentato solo mediante l’adattatore.
EUROPE - EU
Utilizzare l’adattatore per c.a. da 3.3V c.c. e 1.5A conforme alla normativa TÜV.
$ 16TEMPERATURA DI FUNZIONAMENTO
Questo prodotto è concepito per una temperatura ambientale massima di 40 gradi
centigradi.
$ 17TUTTI I PAESI: installare il prodotto in conformità delle vigenti normative
elettriche nazionali.
Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer.
$ 1RFI strålingEN55022 Klasse B
$ 2Advarsel: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake
radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler.
$ 3ImmunitetEN55024
$ 4Advarsel: Dette produktet må brukes med vernede kabler for å tilfredsstille
emisjons- og fritakelsesstandarder. Dersom produktet brukes med uvernede kabler,
må brukeren muligens rette forstyrrelsesproblemene for egen regning.
$ 8ADVARSAL Stirr ikke på strålen.
$ 9ELEKTRISITET
Advarsel: FARE FOR ELEKTRISK SJOKK
For å unngå ELEKTRISK sjokk, må dekslet ikke tas av. Det finnes ingen
deler som brukeren kan reparere på innsiden. Denne enheten inneholder
FARLIGE SPENNINGER, og må kun åpnes av en faglig kvalifisert
tekniker. For å unngå ELEKTRISK SJOKK må den elektriske strømmen
til produktet være avslått før LAN-kablene til- eller frakobles.
$ 10Dette er et “KLASSE 1 LED PRODUKT”
$ 11FARE FOR LYNNEDSLAG
FARE: ARBEID IKKE på utstyr eller KABLER i TORDENVÆR.
$12Forsiktig: STRØMLEDNINGEN BRUKES TIL Å FRAKOBLE UTSTYRET. FOR
Å DEAKTIVISERE UTSTYRET, må strømforsyningen kobles fra.
$13UTSTYR FOR STIKKONTAKT. Stikkontakten skal monteres i nærheten av
utstyret og skal være lett tilgjengelig."
$14Forsiktig: Lufteventilene må ikke blokkeres, og må ha fri tilgang til luft med
romtemperatur for avkjøling.
$ 15All strømtilførsel må komme fra adapteren.
29
Page 40
Electrical Safety and Ins tallation Requiremen t s
EUROPE - EU
Benytt TÜV-godkjent AC-adapter på 3.3V DC, 1.5A (millismpere)
$ 16DRIFTSTEMPERATUR
Dette produktet er konstruert for bruk i maksimum romtemperatur på 40 grader
celsius.
$ 17ALLE LAND: Produktet må installeres i samsvar med de lokale og nasjonale
elektriske koder.
Padrões: Este produto atende aos seguintes padrões.
$ 1Emissão De Interferência De
RadiofrequênciaEN55022 Classe
B
$2Aviso: Num ambiente doméstico este produto pode causar interferência na
radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas
adequadas.
$ 3ImunidadeEN55024
$ 4Advertência: Este produto requer a utilização de cabos blindados para
cumprimento dos standards de limites de emissão e imunidade. Se o produto for
utilizado com cabos não blindados, o utilizador poderá necessitar de tomar medidas
para correcção de problemas de interferência, por sua própria conta.
$ 8Aviso Não olhe fixamente para o raio.
$ 9AVISOS SOBRE CARACTERÍSTICAS ELÉTRICAS
Atenção: PERIGO DE CHOQUE ELÉTRICO
Para evitar CHOQUE ELÉTRICO, não retire a tampa. Não contém peças
que possam ser consertadas pelo usuário. Este aparelho contém
VOLTAGENS PERIGOSAS e só deve ser aberto por um técnico
qualificado e treinado. Para evitar a possibilidade de CHOQUE
ELÉTRICO, desconecte o aparelho da fonte de energia elétrica antes de
conectar e desconectar os cabos da LAN.
$ 10Este é um “PRODUTO CLASSE 1 LED”
$ 11PERIGO DE CHOQUE CAUSADO POR RAIO
PERIGO: NÃO TRABALHE no equipamento ou nos CABOS durante períodos
suscetíveis a QUEDAS DE RAIO.
$ 12Cuidado: O cabo de alimentação é utilizado como um dispositivo de desconexão.
Para deseletrificar o equipamento, desconecte o cabo de alimentação.
$ 13EQUIPAMENTO DE LIGAÇÃO, a tomada eléctrica deve estar instalada perto do
equipamento e ser de fácil acesso."
$ 14Cuidado: As aberturas de ventilação não devem ser bloqueadas e devem ter acesso
livre ao ar ambiente para arrefecimento adequado do aparelho.
$ 15Use somente o adaptador fornecido para alimentação elétrica do hub.
EUROPE - EU
Use um adaptador de corrente alternada com saída DC de 3.3V e 1.5A em
conformidade com as especificações da TÜV.
30
Page 41
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
$ 16TEMPERATURA DE FUNCIONAMENTO
Este produto foi projetado para uma temperatura ambiente máxima de 40 graus
centígrados.
$ 17TODOS OS PAÍSES: Instale o produto de acordo com as normas nacionais e locais
para instalações elétricas.
Estándares: Este producto cumple con los siguientes estándares.
$ 1Emisión RFIEN55022 Clase B
$ 2Advertencia: en un entorno doméstico, este producto puede causar
radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas
que sean convenientes al respecto.
$ 3InmunidadEN55024
$ 4Advertencia: Este producto exige cables protectores para ajustarse a las normas de
emisión e inmunidad. Si se utiliza con cables sin protección, el usuario tendrá que
correr con los gastos por las medidas a tomar en caso de problemas de interferencias.
$ 8¡ADVERTENCIA! No mirat fijamente el haz.
$ 9AVISOS ELECTRICOS
Advertencia: PELIGRO DE ELECTROCHOQUE
Para evitar un ELECTROCHOQUE, no quite la tapa. No hay ningún
componente en el interior al cual puede prestar servicio el usuario. Esta
unidad contiene VOLTAJES PELIGROSOS y sólo deberá abrirla un
técnico entrenado y calificado. Para evitar la posibilidad de
ELECTROCHOQUE desconecte la corriente eléctrica que llega al
producto antes de conectar o desconectar los cables LAN.
$ 10Este es un “PRODUCTO DE DIODO LUMINISCENTE (LED) CLASE 1”
$ 11PELIGRO DE RAYOS
Eligro: NO REALICE NINGUN TIPO DE TRABAJO O CONEXION en los equipos
o en LOS CABLES durante TORMENTAS ELECTRICAS.
$ 12ATENCION: EL CABLE DE ALIMENTACION SE USA COMO UN
DISPOSITIVO DE DESCONEXION. PARA DESACTIVAR EL EQUIPO, desconecte
el cable de alimentación.
$ 13EQUIPO CONECTABLE, el tomacorriente se debe instalar cerca del equipo, en un
lugar con acceso fácil".
$ 14ATENCION: Las aberturas para ventilación no deberán bloquearse y deberán tener
acceso libre al aire ambiental de la sala para su enfriamiento.
$ 15La energía para el dispositivo central o "hub" debe provenir únicamente del
adaptador.
EUROPE - EU
Utilizar un adaptador de corriente alterna autorizado TÜV de 3.3 voltios de corriente
continua y 1.5 miliamperios.
$ 16TEMPERATURA REQUERIDA PARA LA OPERACIÓN
Este producto está diseñado para una temperatura ambiental máxima de 40 grados
C.
31
Page 42
Electrical Safety and Ins tallation Requiremen t s
$ 17PARA TODOS LOS PAÍSES: Monte el producto de acuerdo con los Códigos
Eléctricos locales y nacionales.
Standarder: Denna produkt uppfyller följande standarder.
$ 1RadiostörningEN55022 Klass B
$ 2Varning: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan
tvinga användaren till att vidtaga erforderliga åtgärder.
$ 3ImmunitetEN55024
$ 4Varning! Denna produkt kräver skärmade kablar för att uppfylla standardkraven
för emission och immunitet. Om den används med oskärmade kablar kan
användaren vara tvungen att vidta åtgärder på egen bekostnad för att åtgärda
störningsproblemet.
RISK FÖR ELEKTRISK STÖTFör att undvika ELEKTRISK stöt, ta ej av locket. Det
finns inga delar inuti som behöver underhållas. Denna apparat är under
HÖGSPÄNNING och får endast öppnas av en utbildad kvalificerad tekniker. För att
undvika ELEKTRISK STÖT, koppla ifrån produktens strömanslutning innan LANkablarna ansluts eller kopplas ur.
$ 10Detta är en “KLASS 1 LYSDIODPRODUKT”
$ 11FARA FÖR BLIXTNEDSLAG
Fara: ARBETA EJ på utrustningen eller kablarna vid ÅSKVÄDER.
$ 12Varning: Nätkabeln används som strömbrytare för att koppla från strömmen, dra
ur nätkabeln.
$13UTRUSTNING MED PLUGG. Uttaget skall installeras i utrustningens närhet och
vara lättåtkomligt".
$ 14VARNING: Luftventilerna får ej blockeras och måste ha fri tillgång till omgivande
rumsluft för avsvalning.
$ 15Endast anslutningsenheten får vara kraftkälla till centralen.
EUROPE - EU
Använd en växelströmsanslutningsenhet licensierad av TÜV. Likström 3.3V, 1.5A.
$ 16DRIFTSTEMPERATUR
Denna produkt är konstruerad för rumstemperatur ej överstigande 40 grader
Celsius.
$ 17ALLA LÄNDER: Installera produkten i enlighet med lokala och statliga
bestämmelser för elektrisk utrustning.
32
Page 43
Appendix C
Technical Support Fax Order
Name _________________________________________________________________
Company______________________________________________________________
Address _______________________________________________________________
City______________________ State/Province _______________________________
Zip/Postal Code ________________ Country _______________________________
Phone______________________________ Fax_______________________________
Incident Summary