Allied Telesis AT-FS217 User Manual

Page 1
AT-FS211 AT-FS212 AT-FS212/1 AT-FS212/2 AT-FS212/3 AT-FS212/4 AT-FS214 AT-FS215 AT-FS216 AT-FS217
Wall-Mountable Fast Ethernet Switches
PN 613-50226-00 Rev B
Installation Guide
Page 2
Copyright 2001 Allied Telesyn International Corp. 960 Stewart Drive, Suite B, Sunnyvale CA 94085 USA
All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International Corp.
Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Allied Telesyn International Corp. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesyn International Corp. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesyn International Corp. has been advised of, known, or should have known, the possibility of such damages.
Page 3

Safety Warnings

Standards: This product meets the following standards.
DECLARATION OF CONFORMITY Manufacture Name: Allied Telesyn International Corp. Manufacture Address: 960 Stewart Drive, Suite B
Manufacture Telephone: 408-730-0950 Declares that the product: Fast Ethernet Switches Model Numbers: AT-FS211, AT-FS212, AT-FS212/1,
This product complies with FCC Part 15B, Class B Limits: This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device must not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class B
digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on. The user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission rules.
U.S. Federal Communications Commission
Sunnyvale, CA 94085 USA
AT-FS212/2, AT-FS212/3, AT-FS212/4, AT-FS214, AT-FS215, AT-FS216, AT-FS217
Industry Canada
This Class B digital apparatus meets all requirements of the Canadian Interference­Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
RFI Emission EN55022 Class B Warning: In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures. Immunity EN55024
$ 1
$ 2
$ 3
iii
Page 4
Safety Wa rnings
Warning: This product requires shielded cables to comply with emission and immunity standards. If it is used with unshielded cables, the user may be required to take measures to correct the interference problem at their own expense.
Electrical Safety EN60950 (TUV), UL1950 (UL/cUL) Laser EN60825 Warning Class 1 Laser product. (AT-FS212/x models) Warning Do not stare into the Laser beam.
At time of installation, the Fiber Optic Lasers comply with FDA Radiation Performance Standard 21CFR Subchapter J, applicable at date of manufacture.
This is a CLASS 1 LED PRODUCT (AT-FS21x models)
Important: Appendix B contains translated safety statements for installing this equipment. When you see the your language.
Wichtig: Anhang B enthält übersetzte Sicherheitshinweise für die Installation dieses Geräts. Wenn Sie in Ihrer Sprache nach.
Vigtigt: Tillæg B indeholder oversatte sikkerhedsadvarsler, der vedrører installation af dette udstyr. Når De ser symbolet sikkerhedsadvarsler i Deres eget sprog.
Belangrijk: Appendix B bevat vertaalde veiligheidsopmerkingen voor het installeren van deze apparatuur. Wanneer u de veiligheidsinstructies in uw taal.
Important: L'annexe B contient les instructions de sécurité relatives à l'installation d e cet équipement. Lorsque vous voyez le symbole
la traduction de ces instructions dans votre langue. Tärkeää: Liite B sisältää tämän laitteen asentamiseen liittyvät käännetyt turvaohjeet.
Kun näet Importante: lAppendice B contiene avvisi di sicurezza tradotti per linstallazione di
questa apparecchiatura. Il simbolo sicurezza nella propria lingua.
Viktig: Tillegg B inneholder oversatt sikkerhetsinformasjon for installering av dette utstyret. Når du ser sikkerhetsinformasjonen på ønsket språk.
Importante: O Anexo B contém advertências de segurança traduzidas para instalar este equipamento. Quando vir o símbolo idioma no Anexo B.
Importante: El Apéndice B contiene mensajes de seguridad traducidos para la instalación de este equipo. Cuando vea el símbolo mensaje de seguridad traducido a su idioma.
Obs! Bilaga B innehåller översatta säkerhetsmeddelanden avseende installationen av denna utrustning. När du ser säkerhetsmeddelandet på ditt språk.
$ 4
$ 6
$ 7
$ 8
$ 9
$
, go to Appendix B for the translated safety statement in
$
sehen, schlagen Sie in Anhang B den übersetzten Sicherheitshinweis
$
, skal De slå op i tillæg B og finde de oversatte
$
ziet, raadpleeg Appendix B voor vertaalde
$
, reportez-vous à l'annexe B pour consulter
$
-symbolin, katso käännettyä turvaohjetta liitteestä B.
$
, indica di consultare lAppendice B per lavviso di
$
, åpner du til Tillegg B for å finne den oversatte
$
, leia a advertência de segurança traduzida no seu
$
, vaya al Apéndice B para ver el
$
, skall du gå till Bilaga B för att läsa det översatta
$ 5
iv
Page 5

Table of Contents

Safety Warnings ............................................................................................iii
Welcome to Allied Telesyn .........................................................................vii
Where to Find Web-based Guides ...................................................................vii
Document Conventions ....................................................................................vii
Contacting Allied Telesyn...............................................................................viii
Online Support .........................................................................................viii
Technical and Fax Support......................................................................viii
Technical Support E-mail Addresses ........................................................ix
Returning Products ........................................................................................... ix
FTP Server.........................................................................................................ix
For Sales or Corporate Information ..................................................................x
Tell Us What You Think .................................................................................... x
Chapter 1
Overview ..........................................................................................................1
Key Features.......................................................................................................3
Switch Performance .................................................................................... 3
Status LEDs ................................................................................................ 4
External Power Adapter .............................................................................4
Auto MDI/MDI-X.........................................................................................4
Functional Description....................................................................................... 5
Frame Processing........................................................................................ 5
Address Recognition and Filtering.............................................................5
Network Topologies............................................................................................6
Chapter 2
Installing the Switch ..................................................................................... 7
Verifying the Package Contents ........................................................................7
Planning the Installation...................................................................................7
Selecting a Site ...................................................................................................9
Reviewing Safety Guidelines .............................................................................9
Installing the Switch........................................................................................10
Warranty Registration.....................................................................................13
v
Page 6
Chapter 3
Troubleshooting ...........................................................................................15
Appendix A
Technical Specifications ............................................................................17
Specifications ....................................................................................................17
Physical......................................................................................................17
Temperature ..............................................................................................17
Electrical and Mechanical Specifications.................................................17
Electrical Rating........................................................................................18
Fiber Optic Port Specifications ........................................................................18
Pinout Assignments..........................................................................................20
Appendix B
Electrical Safety and Installation Requirements .................................21
Appendix C
Technical Support Fax Order ...................................................................33
Incident Summary............................................................................................33
vi
Page 7

Welcome to Allied Telesyn

This installation guide contains instructions on how to wall-mount the AT-FS21x and the AT-FS212/x Series Fast Ethernet Switches and how to connect the units to your network.

Where to Find Web-based Guides

The Allied Telesyn web site at www.alliedtelesyn.com provides you with an easy way to access the most recent documentation, software, and technical information for all of our products. For product guides, you can go directly to the following web page: www.alliedtelesyn.com/support/prd_libs.htm.

Document Conventions

This guide uses several conventions that you should become familiar with before you begin to install the product.
Note
A note provides additional information.
Caution
A caution indicates that performing or omitting a specific action may result in equipment damage or loss of data.
Warning
A warning indicates that performing or omitting a specific action may result in bodily injury.
vii
Page 8
Welcome to Allied Telesyn

Contacting Allied Telesyn

You can contact Allied Teleysn technical support online or by telephone, fax, or e-mail.

Online Support

You can request technical support online by filling out the Online Technical Support Form at www.alliedtelesyn.com/support/supportf.asp or by accessing the Technical Support Knowledge Base from Allied Telesyns North American web site. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.

Technical and Fax Support

For technical support via fax, please fill out the Technical Support Fax Order on page 33 and send it to the appropriate location listed below.
Americas
United States, Canada, Mexico, Central America, South America Tel: 1 (800) 428-4835, option 4 Fax: 1 (425) 481-3790
Asia
Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India, Hong Kong Tel: (+65) 3815-612 Fax: (+65) 3833-830
Australia
Australia, New Zealand Tel: 1 (800) 000-880 Fax: (+61) 2-9438-4966
France
France, Belgium, Luxembourg, The Netherlands, Middle East, Africa Tel: (+33) 1-60-92-15-25 Fax: (+33) 1-69-28-37-49
Germany
Germany, Switzerland, Austria, Eastern Europe Tel: (+49) 30-435-900-126 Fax: (+49) 30-435-70-650
Italy
Italy, Spain, Portugal, Greece, Turkey, Israe
l
Tel: (+39) 02-41-30-41 Fax: (+39) 02-41-30-42-00
Japan
Tel: (+81) 3-3443-5640 Fax: (+81) 3-3443-2443
United Kingdom
United Kingdom, Denmark, Norway, Sweden, Finland Tel: (+44) 1-235-442500 Fax: (+44) 1-235-442680
viii
Page 9
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de

Technical Support E-mail Addresses

United States and Canada
TS1@alliedtelesyn.com
Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands
latin_america@alliedtelesyn.com
Europe
support_europe@alliedtelesyn.com

Returning Products

Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the senders expense.
To obtain an RMA number, contact Allied Telesyns Technical Support at one the following locations:
North America
Toll-free: 1-800-428-4835, option 4 Fax: 1-425-481-3790
Latin America, the Caribbean, and Virgin Islands
Tel: international code + 425-481-3852 Fax: international code + 425-481-3895
Mexico
Toll-free: 800-424-5012, ext 3852 Fax: international code + 425-481-3895
Australia
Toll-free: 1-800-000-880 Fax: +61-2-9438-4966
Europe, Africa, and the Middle East
Tel: +44-1793-501401 Fax: +44-1793-431099
Puerto Rico
Tel: 1-800-424-5012, ext 3852 or 1-800-424-4284, ext 385
Asia and Southeast Asia
Tel: +65-381-5612 Fax: +65-383-3830
New Zealand
Toll-free: 0800-45-5782
2

FTP Server

If you need management software for an Allied Telesyn device and you know the file name of the software, you can download the software by connecting directly to our FTP server at ftp.alliedtelesyn.com. At login, enter anonymous as the user name and your e-mail address for the password.
ix
Page 10
Welcome to Allied Telesyn

For Sales or Corporate Information

You can contact Allied Telesyn for sales or corporate information at one of the locations below:
Allied Telesyn International Corp.
19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191
Allied Telesyn International Corp.
960 Stewart Drive, Suite B Sunnyvale, CA 94085 Tel: 1 (800) 424-4284 (US and Canada) Fax: 1 (408) 736-0100

Tell Us What You Think

If you have any comments or suggestions on how we might improve this or other Allied Telesyn documents, please fill out the Send Us Feedback Form at www.alliedtelesyn.com/contact/feedbackf.asp.
x
Page 11

Chapter 1

Overview

The AT-FS21x and AT-FS212/x Series Fast Ethernet Switches feature the following models:
AT-FS211 AT-FS212/4 AT-FS212 AT-FS214 AT-FS212/1 AT-FS215 AT-FS212/2 AT-FS216 AT-FS212/3 AT-FS217
These switches are designed to interconnect LAN devices and subnetworks over large distances. These dual-port switches can also improve the performance of your network by dividing it into smaller, more manageable segments.
The AT-FS21x and AT-FS212/x Series Switches have a 10/100Base-TX twisted pair port and a 100Base-FX fiber optic port. The twisted pair port has an RJ-45 connector and a maximum operating distance of 100 meters (328 feet). This port operates at 10/100 Mbps and features half- and full-duplex operation.
The fiber optic port has a FJ, LC, MT-RJ, SC, ST, or VF-45 connector and a maximum operating distance 2 kilometers (1.2 miles) to 100 kilometers (62 miles), depending on the model. This port operates at 100 Mbps and features full-duplex operation.
1
Page 12
Overview
These switches are easy to install and do not require software configuration or management. Figure 1 illustrates an AT-FS21x Series Switch.
Mounting Bracket Screws
4
1
2
S
F
-
T
A
Fast Ethernet Switch
LEDs
X
F
R
W
P
X
T
10Base-T/ 100Base-TX
C
D
V
.3
3
Cable Hook
DC Connector10/100Base-TX Port
Figure 1 AT-FS21x Series Switch (Model AT-FS214)
Table 1 lists the operating distances for the AT-FS21x and AT-FS212/x Series Switches.
Table 1 Maximum Operating Distance
Model 10/100Base-TX
Connector Maximum
Operating Distance
1
100Base-FX
Connector Maximum
Operating Distance
2
AT-FS211 RJ-45 100 m (328 ft) ST 2 km (1.2 mi) AT-FS212 RJ-45 100 m (328 ft) SC 2 km (1.2 mi) AT-FS212/1 RJ-45 100 m (328 ft) SC 15 km (9.3 mi) AT-FS212/2 RJ-45 100 m (328 ft) SC 40 km (24.8 mi) AT-FS212/3 RJ-45 100 m (328 ft) SC 70 km (43.4 mi) AT-FS212/4 RJ-45 100 m (328 ft) SC 100 km (62 mi) AT-FS214 RJ-45 100 m (328 ft) MT-RJ 2 km (1.2 mi) AT-FS215 RJ-45 100 m (328 ft) VF-45 2 km (1.2 mi) AT-FS216 RJ-45 100 m (328 ft) LC 2 km (1.2 mi) AT-FS217 RJ-45 100 m (328 ft) FJ 2 km (1.2 mi)
1. Maximum distance can only be obtained when the UTP/STP cabling is installed and verified to the TIA/EIA 568A
Commercial Building Telecommunications Cabling Standard.
2. Maximum distance for 100 Mbps Optical Datalinks are dependent on the following factors: type of optical fiber,
duplex mode of both end-nodes, and maximum optical loss budget for each of the optical fiber at the operating optical wavelength.
2
Page 13
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de

Key Features

The switches have the following key features:
LEDs for unit and port status
Wall-mountable chassis
Auto MDI/MDI-X
External AC/DC power adapters (North America, Continental, or
Europe)
Full- or half-duplex mode operation on the twisted pair port
Full-duplex operation on the fiber optic port
FJ, LC, MT-RJ, SC, ST, or VF-45 fiber optic connector
Data packet forwarding and filtering at full wire speed
Store and forward switching mode
Automatic address learning and aging
IEEE 802.3u compliant auto-negotiation on the twisted pair port

Switch Performance

The switches perform at:
148,800 pps for 100 Mbps and 14,880 pps for 10 Mbps with full wire
speed forwarding and filtering
200 Mbps maximum throughput in 100 Mbps, full-duplex mode
20 Mbps maximum throughput in 10 Mbps, full-duplex mode
Storage for up to 4,000 MAC addresses
Unlimited multicast/broadcast addresses
Low latency 15.6 µs (64-byte packet, 100 Mbps full-duplex)
3
Page 14
Overview

Status LEDs

Table 2 lists the switch LEDs.
Table 2 AT-FS21x and AT-FS212/x Series Switch LEDs
LED Color Description
PWR Green Power is applied. FX Green
Blinking
TX Green
Blinking
100M Green
OFF
A link has been established on the fiber optic port Activity has been detect ed on the fiber optic port.
A link has been establ ished on the twisted pair port Activity has been detected on the twisted pair port.
The twisted pair port is operating at 100 Mbps. The twisted pair port is operating at 10 Mbps.

External Pow er Adapter

The power adapter supplies 3.3V DC to the switch. Allied Telesyn supplies an approved safety compliant AC power adapter for 3.3 V/1.5 A versions with an unregulated output of 3.3V DC.

Auto MDI/MDI-X

An RJ-45 twisted pair port on a 10 Mbps or 100 Mbps Ethernet network device can have one of two possible wiring configurations: MDI or MDI-X. The RJ-45 port on a PC, router, or bridge is typically wired as MDI, while the twisted pair port on a switch or hub is usually MDI-X.
To connect two 10 Mbps or 100 Mbps network devices together that have dissimilar port wiring configurations, such as MDI to MDI-X, you use a straight-through twisted pair cable. To connect two network devices that have the same wiring configuration, such as MDI to MDI, you use a crossover cable.
The AT-FS21x and AT-FS212/x Series Switches feature automatic MDI/ MDI-X. Each port automatically determines the configuration of the port on the device to which it is connected and then configures itself appropriately. For example, if a port on a switch is connected to a port on a bridge, which is typically wired as MDI, the port on the switch automatically configures itself as MDI-X. This eliminated the need for using a crossover cable with these switches.
4
Page 15
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de

Functional Description

Frame Process ing

The switches support store and forward switching at Fast Ethernet full-wire speed in 10 or 100 Mbps, half- or full-duplex mode. Packets entering each port are stored in buffers. After the full packet is received, it is forwarded or discarded depending on its destination address and error status. This ensures that only error-free data packets destined for another segment will be transferred across the switch, reducing network load. For example, if the packet entering from Port 1 is destined for an end station on Port 2, it will be forwarded if the Frame Check Sequence (FCS) is valid. If the packet from Port 1 is destined for an end station also attached to Port 1, then the packet is discarded.
The switch will discard CRC error, misaligned, runt, and under-sized/over­sized packets. When the packet has dribble bits at the end, the switch will truncate to octet boundary and check for a good FCS before forwarding.

Address Recognition and Filtering

Up to 4,000 MAC addresses can be stored in the MAC address table. The switch will learn all new addresses in real-time after power-up with its address self-learning mechanism. If the source address of an incoming packet is not found in the address table, the switch waits until the end of the packet to check for good CRC and then updates its MAC address table. Because the switch has Automatic Address Aging, if a source address entry in the table is not updated within five minutes, the entry is deleted from the table. The switch forwards multicast, broadcast, and unicast packets when the MAC address table size is exceeded.
5
Page 16
Overview

Network Topologies

Figure 2 illustrates a topology using one AT-FS214 switch to interconnect two small networks of stackable hubs. Network 1 has an AT-FH812u with an AT-FH807u switching module connected to the 100Base-FX port on the AT-FS214. Network 2 has an AT-3624TR hub connected to the 10/100Base-TX port on the AT-FS214.
Network 1
Network 2
AT-FH812u with an AT-FH807u module
AT-FH812u
AT-FH812u
Twisted Pair Fiber Optic
AT-FS214
AT-FS214
Fast Ethernet Switch
FX
PWR
TX
100MLK/AT
Figure 2 Network Topology
AT-3624TR
AT-3624TR
AT-3624TR
6
Page 17

Chapter 2

Installing the Switch

Verifying the Package Contents

Make sure the following items are included in your package. If any item is missing or damaged, contact your Allied Telesyn sales representative for assistance.
One AT-FS21x or AT-FS212/x Series Fast Ethernet Switch
External power adapter (North America, Continental Europe, or
United Kingdom)
2 Phillips-head screws
2 plastic anchors
Cable tie
This installation guide
Warranty card

Planning the Installation

Be sure to observe the following guidelines when planning the installation of your switch.
The end-node connected to the fiber optic port on the switch must be
able to operate at 100 Mbps and full-duplex mode.
The end-node connected to the twisted pair port can operate at either
10 Mbps or 100 Mbps, half- or full-duplex mode.
The twisted pair cabling must be kept away from sources of electrical
noise, such as radios, transmitters, power lines, broadband amplifiers, electrical motor, and fluorescent fixtures.
Refer to the following tables for the cabling specifications for the 10/
100Base-TX and 100Base-FX ports.
7
Page 18
Installing the S witch
Table 3 10/100Base-TX Twisted Pair Port Cabling Specifications
Operating Mode Twisted Pair Cable
Maximum Operating Distance
10Base-T Shielded or unshielded Category 3 or be tter 100 m (328 ft) 100Base-TX Shielded or unshielded Category 5 or better 100 m (328 ft)7
Table 4 100Base-FX Fiber Optic Port Cabling Specificatio ns (Full-duplex)
Model Fiber Optic Cable
AT-FS211 50/125 or 62.5/125
Maximum Operating Di stance
2 km (1.2 mi) 13 dB at 1310 nm
Maximum Allowable Loss Budget
micron multimode
AT-FS212 50/125 or 62.5/125
2 km (1.2 mi) 13 dB at 1310 nm
micron multimode
AT-FS212/1 9/125 micron
15 km (9.3 mi) 16 dB at 1310 nm
single-mode
AT-FS212/2 9/125 micron
40 km (24.8 mi) 30 dB at 1310 nm
single-mode
AT-FS212/3 9/125 micron
70 km (43.4 mi) 33 dB at 1310 nm
single-mode
AT-FS212/4
1
9/125 micron
100 km (62 mi) 34 dB at 1550 nm
single-mode
AT-FS214 50/125 or 62.5/125
2 km (1.2 mi) 13 dB at 1310 nm
micron multimode
AT-FS215 50/125 or 62.5/125
2 km (1.2 mi) 13 dB at 1310 nm
micron multimode
AT-FS216 50/125 or 62.5/125
2 km (1.2 mi) 13 dB at 1310 nm
micron multimode
AT-FS217 50/125 or 62.5/125
2 km (1.2 mi) 13 dB at 1310 nm
micron multimode
1. The cable must be non-dispersion-shifted, dispersion-shifted, or non-zero dispersion-shifted single-mode fiber
optic cable.
8
Page 19
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
Note
Refer to page 18 for additional fiber optic port specifications.

Selecting a Site

Be sure to observe the following requirements when choosing a site for your switch.
Select a site that is dust-free and moisture-free.
Be sure that the site will allow you to easily access the fiber optic and
twisted pair cables and the power cord.
Use dedicated power circuits or power conditioners to supply reliable
power to the device.

Reviewing Safety Guidelines

Please review the following safety guidelines before you begin to install the media converter.
Warning
Class 1 laser device. $ 7
Warning
Do not stare into the laser beam. $ 8
Warning
Electric Shock Hazard: To prevent electric shock, do not remove the cover. There are no user-serviceable parts inside. The unit contains hazardous voltages and should only be opened by a trained and qualified technician. $ 9
Warning
Lightning Danger: Do not work on this equipment or cables during periods of lightning activity. $ 11
Caution
Power cord is used as a disconnection device: To de-energize equipment, disconnect the power cord. $ 12
9
Page 20

Installing the S witch

Caution
Pluggable Equipment: The socket outlet should be installed near the equipment and should be easily accessible. $ 13
Caution
Air vents: The air vents must not be blocked on the unit and must have free access to the room ambient air for cooling. $ 14
Caution
Operating Temperature: This product is designed for a maximum ambient temperature of 40°C. $ 16
Caution
All Countries: Install this product in accordance with local and National Electric Codes. $ 17
Installing the Switch
To install an AT-FS21x or AT-FS212/x Series Switch, perform the following procedure:
1. Remove all equipment from the package and store the packaging in a safe
place.
2. Remove the mounting bracket screws, as shown in Figure 3. These screws
are marked with black circles.
h
itc
w
t S
e
n
r
e
th
AT-FS214
t E
s
a
F
PWR
FX
TX
10Base-T/ 100Base-TX
C
D
V
.3
3
Figure 3 Removing the Moun ting Bracket Screws
10
Page 21
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
3. Gently slide the bracket off the switch. See Figure 4.
Figure 4 Sliding the Wall-mounting Bracket of f t he Switch
Note
For drywall installation, drill two 3/16-inch holes, insert the plastic anchors and tap flush.
4. Position the wall-mounting bracket on the wall and, using two
Phillips-head screws (provided), secure the bracket to the wall. See Figure
5.
Figure 5 Attaching the Wall-mounting Bracket to the Wall
11
Page 22
Installing the S witch
Note
The switch can be mounted either vertically or horizontally.
5. Using the flanges under the fiber optic port as a guide, slide the switch
into the mounting bracket. Refer to Figure 6.
Flange Flange
AT-FS214
Fast Ethernet S
witch
F
X
P
W
R
T
X L
K
/
A
T
1
0
0
M
Figure 6 Sliding the Switch Over the Wall-mounting Bracket
6. Secure the switch to the wall-mounting bracket using the screws removed
in Step 2.
7. If your switch is shipped with Universal Voltage Power Adapter (2-cable),
do the following:
a. Connect the AC power cord to the Universal Voltage Power Adapter.
b. Plug the DC cable into the DC receptacle on the switch.
c. Plug the AC power cord on the adapter to a power outlet.
12
Page 23
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
8. If your switch is shipped with an Single Voltage Power Adapter (single
cable), do the following:
a. Plug the DC cable into the DC receptacle on the switch.
b. Plug the AC power cord to a power outlet.
Note
To prevent the DC power cable from being inadvertently pulled out of the switch, use the cable tie supplied with the unit to secure the DC power cable to the cable hook located next to the DC connector.
9. Verify that the PWR LED on the switch is green. If the LED is OFF, refer
to Troubleshooting on page 15.
10. Remove the dust cover from the 100Base-FX fiber optic port and connect
the fiber optic cable.
11. Connect the twisted pair cable to the 10/100Base-TX port.
12. Power ON the end-nodes. The TX and FX LEDs should be green. If the
LEDs are OFF, refer to “Troubleshooting on page 15.
13. The switch is now ready for use.

Warranty Registration

When you finish installing the product, you should register your product by completing the enclosed warranty card and sending it in. You can also fill out the registration online at www.alliedtelesyn.com/support/warrantyf.asp.
13
Page 24
Page 25

Chapter 3

Troubleshooting

Follow the guidelines below to test and troubleshoot the installation in the event a problem occurs.
If the PWR LED is OFF, do the following:
Make sure that the power adapter is securely connected to a power
source and the DC power cord on the adapter is securely connected to the DC power connector on the switch.
Verify that the power outlet has power by connecting another device
to it.
Try connecting the switch to another power source.
Try using another power adapter.
If the TX LED for the twisted pair port is powered OFF, do the following:
Check that the end-node connected to the port is ON and is operating
properly.
Check that the twisted pair cable is securely connected to the twisted
pair port on the switch and on the end-node.
Make sure that the twisted pair cable does not exceed 100 meters (328
feet).
If the end-node is operating at 100 Mbps, verify that you are using
Category 5 or better twisted pair cabling.
If the FX LED for the fiber optic port is powered OFF, do the following:
Verify that the end-node connected to the port is ON and is operating
properly.
Check that the fiber optic cable is securely connected to the fiber optic
port on the switch and on the end-node.
15
Page 26
Troubleshooting
Check to be sure that the end-node connected to the port is operating
at 100 Mbps.
Make sure that the fiber optic port on the end-node is operating in
full-duplex mode.
Make sure that the cable connected to the fiber optic receiver port on
the switch is connected to the transmitter port on the remote end-node and that the fiber optic transmitter port on the switch is connected to the receiver port on the end-node.
Test the attenuation on the fiber cable to ensure that it does not
exceed acceptable values.
Verify that you are using the appropriate type of fiber optic cable and
that you have not exceeded the maximum operating distance. For cable types and operating distances, refer to Table 4 on page 8.
Check that the operating specifications of the fiber optic port on the
end-node are compatible with the operating specifications of the fiber optic port on the switch. Refer to page 18 for the fiber optic port specifications.
If you are still experiencing problems after testing and troubleshooting the installation, contact Allied Telesyn Technical Support for assistance. Refer to Contacting Allied Telesyn on page viii or visit our web site at www.alliedtelesyn.com for support information.
16
Page 27

Appendix A

Technical Specifications

Specifications

Physical

Dimensions: 90 mm x 24 mm x 70 mm
(3.54 in x 0.94 in x 2.76 in)
Weight: 0.23 kg (0.5 lbs)

Temperature

Operating: 0° to 40° C
Storage: -25° to 70° C
Relative Humidity: 5% to 80% (non-condensing)
Operating Altitude: Up to 10,000 feet

Electrical and Mechanical Specifications

Standard: CE Compliant IEEE 802.3, IEEE 802.3u
Immunity: Conforms to EN500082-1 1997 immunity
standard
Safety: Conforms to all standards normally supported
by Allied Telesyn products including safety standards UL 1950 (UL/cUL), TUV EN60950, EN60825 CE Compliant
EMI/RFI: Meets all applicable requirements for emissions
including but not limited to FCC Class A, EN55022 Class A
17
Page 28
Technical Specifications

Electrical Rating

Input Supply Voltage 3.3V DC
Minimum Current Rating 1.5A
Maximum Power
Consumption 6W

Fiber Optic Port Specifications

The following tables list the specifications for the 100Base-FX fiber optic port.
Table 5 Fiber Optic Transmi tter
2
Model
AT-FS211
Fiber Type
1
Fiber Optic Diameter
Optical Frequency
Maximum A verage Minimum
Launch Power
MMF 50/125 1310 nm -14.0 -20.3 -22.5 AT-FS212 AT-FS214
MMF 62.5/125 1310 nm -14.0 -16.8 -19.0 AT-FS215
AT-FS216 AT-FS217
AT-FS212/1 SMF 9/125 1310 nm -8.0 -11.5 -15.0 AT-FS212/2 SMF 9/125 1310 nm 0.0 -3.0 -5.0 AT-FS212/3 SMF 9/125 1310 nm 0.0 -2.0 -4.0
3
AT-FS212/4
1. MMF = Multimode Fiber / SMF = Single-mode Fiber.
2. The launch power is measured at one meter from the transmitter.
3. The cable must be non-dispersion-shifted, dispersion-shifted, or non-zero dispersion-shifted single-mode fiber optic cable.
SMF 9/125 1550 nm 0.0 -1.5 -3.0
18
Page 29
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
Table 6 Fiber Optic Receiver
Receiver Power
Typical Sensitivity
Model
AT-FS211
Fiber Type
1
Fiber Optic Diameter
Optical Frequency
Minimum
MMF 50/125 1310 nm -31.8 -34.5 -14.0 AT-FS212 AT-FS214
MMF 62.5/125 1310 nm -31.8 -34.5 -14.0 AT-FS215
AT-FS216 AT-FS217
AT-FS212/1 SMF 9/125 1310 nm -31.0 -31.0 -8.0 AT-FS212/2 SMF 9/125 1310 nm -35.0 -38.0 0.0 AT-FS212/3 SMF 9/125 1310 nm -37.0 -37.0 -3.0 AT-FS212/4 SMF 9/125 1550 nm -37.0 -37.0 -3.0
1. MMF = Multimode Fiber / SMF = Single-mode Fiber.
Table 7 Fiber Optic Dat alink
Model Fiber Type
Minimum Power/Link Budget
Average Signal Loss
Minimum Operating Distance
1
Maximum Operating Distance
Saturation
AT-FS211 AT-FS212
50/125 MMF
13.00 18.70 0 2 km (1.25 mi)
AT-FS214 AT-FS215 AT-FS216
62.5/125 MMF
16.80 22.50 0 2 km (1.25 mi)
AT-FS217 AT-FS212/ 1 9/125 SMF 16.00 19.50 0 15 km (9.4 mi) AT-FS212/2 9/125 SMF 30.00 35.00 0 40 km (25 mi) AT-FS212/ 3 9/125 SMF 33.00 35.00 15 km
(9.3 mi)
AT-FS212/ 4 9/125 SMF 34.00 35.00 40 km
(24.8 mi)
1. The recommended minimum range is stated in all cases where the maximum transmitter output power exceeds the receivers saturation level. This is to prevent blinding or burning out of the optical receiver on the far end-node.
70 km (43.4 mi)
100 km (62 mi)
19
Page 30
Technical Specifications
Table 8 Fiber Optic Loss Specification (Benchmarks)
Fiber Type
Multimode
Fiber Optic Diameter
50/125 1310 nm 1.00 db/km 1.50 db/km 400
Optical Frequency
Typical Loss Factor
Worst Case Loss Factor
Bandwidth
Fiber
62.5/125 1310 nm 1.00 db/km 1.5 db/km 500
Single-mode 9/125 nm 1310 nm 0.40 db/km 1 .00 db/km N/A
9/125 nm 1550 nm 0.30 db/km 0.75 db/km N/A

Pinout Assignments

Figure 7 shows the pin assignments of the switchs 10/100Base-TX RJ-45 port.
Pin 1 Pin 8
Figure 7 RJ-45 Pin Assignments
Table 9 lists the RJ-45 connector pins and their signals for 10/100Base-TX.
Table 9 RJ-45 Pin Signals
MDI-X (Default) Signal MDI Signal
1RX+1 TX+ 2RX-2 TX­3 TX+ 3 RX+ 4- 4 ­5- 5 ­6 TX- 6 RX­7- 7 ­8- 8 -
20
Page 31

Appendix B

Electrical Safety and Installation Requirements

Important: This appendix contains multiple-language translations for the safety statements in this guide.
Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen.
Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog.
Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Important: Cette annexe contient la traduction en plusieurs langues des instructions de sécurité figurant dans ce guide.
Tärkeää: Tämä liite sisältää tässä oppaassa esiintyvät turvaohjeet usealla kielellä.
Importante: questa appendice contiene traduzioni in più lingue degli avvisi di sicurezza di questa guida.
Viktig: Dette tillegget inneholder oversettelser til flere språk av sikkerhetsinformasjonen i denne veiledningen.
Importante: Este anexo contém traduções em vários idiomas das advertências de segurança neste guia.
Importante: Este apéndice contiene traducciones en múltiples idiomas de los mensajes de seguridad incluidos en esta guía.
Obs! Denna bilaga innehåller flerspråkiga översättningar av säkerhetsmeddelandena i denna handledning.
21
Page 32
Electrical Safety and Ins tallation Requiremen t s
Standards: This product meets the following standards.
U.S. Federal Communications Commission
DECLARATION OF CONFORMITY Manufacture Name: Allied Telesyn International Corp. Manufacture Address: 960 Stewart Drive, Suite B
Manufacture Telephone: 408-730-0950 Declares that the product: Fast Ethernet Switches Model Numbers: AT-FS211, AT-FS212, AT-FS212/1,
This product complies with FCC Part 15B, Class B Limits: This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device must not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class B
digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on. The user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission rules.
Sunnyvale, CA 94085 USA
AT-FS212/2, AT-FS212/3, AT-FS212/4, AT-FS214, AT-FS215, AT-FS216, AT-FS217
Industry Canada
This Class B digital apparatus meets all requirements of the Canadian Interference­Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
$ 1 RFI Emission EN55022 Class B
$ 2 Warning: In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
$ 3 Immunity EN55024
$ 4 Warning: This product requires shielded cables to comply with emission and
immunity standards. If it is used with unshielded cables, the user may be required to take measures to correct the interference problem at their own expense.
$ 5 Electrical Safety EN60950 (TUV), UL1950 (UL/cUL)
$ 6Laser EN60825
SAFETY
22
Page 33
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
$ 7 Warning Class 1 Laser product. (AT-FS212/x models)
$ 8 Warning Do not stare into the Laser beam.
At time of installation, the Fiber Optic Lasers comply with FDA Radiation Performance Standard 21CFR Subchapter J, applicable at date of manufacture.
$ 9 ELECTRICAL NOTICES
Warning: ELECTRIC SHOCK HAZARD
To prevent ELECTRIC shock, do not remove the cover. No user­serviceable parts inside. This unit contains HAZARDOUS VOLTAGES and should only be opened by a trained and qualified technician. To avoid the possibility of ELECTRIC SHOCK, disconnect electric power to the product before connecting or disconnecting the LAN cables.
$ 10 This is a CLASS 1 LED PRODUCT (AT-FS21x models)
$ 11 LIGHTNING DANGER
Danger: DO NOT WORK on equipment or CABLES during periods of LIGHTNING ACTIVITY.
$ 12 Caution: Power cord is used as a disconnection device. to de-energize
equipment, disconnect the power cord.
$ 13 Pluggable equipment, the socket outlet shall be installed near the
equipment and shall be easily accessible.
$ 14 Caution: Air vents must not be blocked and must have free access to the room
ambient air for cooling.
$ 15 Power to the hub must be sourced only from the adapter.
USA/CANADA
Use a UL Listed/CSA Certified AC adapter of DC 3.3V, 1.5A.
EUROPE - EU
Use TÜV licensed AC adapter of DC 3.3V, 1.5A.
UK
Use a UK Safety Approved AC adapter of DC 3.3V, minimum 1.5A.
$ 16 Operating Temperature: This product is designed for a maximum ambient
temperature of 40 degrees C.
$ 17 All Countries: Install product in accordance with local and National Electrical
Codes.
Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen.
$ 1Hochfrequenzstörung EN55022 Klasse B
$ 2 Warnung: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen
hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen.
$ 3Störsicherheit EN55024
$ 4 Achtung: Für dieses Produkt sind abgeschirmte Kabel erforderlich, damit den
Richtlinien für Emission und Interferenzschutz entsprochen wird. Falls das Produkt mit nicht abgeschirmten Kabeln verwendet wird, können weitergehende Maßnahmen für die Korrektur von Interferenzproblemen auf Kosten des Benutzers notwendig werden.
$ 5 Elektrische Sicherheit EN60950 (TUV), UL1950 (UL/cUL)
$ 6Laser EN60825
23
Page 34
Electrical Safety and Ins tallation Requiremen t s
SICHERHEIT
$ 7 Warnung Laserprodukt der Klasse 1.
$ 8 Warnung Nicht direkt in den Strahl blicken. $ 9 Achtung: GEFÄHRLICHE SPANNUNG
Das Gehäuse nicht öffnen. Das Gerät enthält keine vom Benutzer wartbaren Teile. Das Gerät steht unter Hochspannung und darf nur von qualifiziertem technischem Personal geöffnet werden. Vor Anschluß der LAN-Kabel, Gerät vom Netz trennen.
$ 10 Das ist ein LED Produkt der Klasse 1
$ 11 GEFAHR DURCH BLITZSCHLAG
Gefahr: Keine Arbeiten am Gerät oder an den Kabeln während eines Gewitters ausführen.
$ 12 Vorsicht: Das netzkabel dient zum trennen der stromversorgung. Zur trennung
vom netz, kabel aus der steckdose ziehen.
$ 13 Steckbares Gerät: Die Anschlußbuchse sollte in der Nähe der Einrichtung
angebracht werden und leicht zugänglich sein."
$ 14 Vorsicht
Die Entlüftungsöffnungen dürfen nicht versperrt sein und müssen zum Kühlen freien Zugang zur Raumluft haben
.
$ 15 Der Buchse darf nur aus dem Adapter Strom zugeführt werden.
EUROPE - EU
Gebrauchen Sie einen von TÜV zugelassenen Wechselstromadapter für Gleichstrom
3.3V, 1.5A.
$ 16 Betriebstemperatur
Dieses Produkt wurde für den Betrieb in einer Umgebungstemperatur von nicht mehr als 40° C entworfen.
$ 17 Alle Länder: Installation muß örtlichen und nationalen elektrischen Vorschriften
entsprechen.
Standarder: Dette produkt tilfredsstiller de følgende standarder.
$ 1 Radiofrekvens
forstyrrelsesemission EN55022 Klasse B
$ 2 Advarsel: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse.
Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger.
$ 3 Immunitet EN55024
$ 4 Advarsel: Dette produkt skal bruges med afskærmede kabler for at overholde
bestemmelserne vedrørende udstråling og støjimmunitet. Hvis det bruges med uafskærmede kabler, kan det blive påkrævet af brugeren at korrigere interferensproblemer for egen regning.
$ 5 Elektrisk sikkerhed. EN60950 (TUV), UL1950 (UL/cUL)
$ 6Laser EN60825
SIKKERHED
$ 7 Advarsel Laserprodukt av klasse 1.
$ 8Advarsel Stirr ikke på strålen.
24
Page 35
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
$ 9 ELEKTRISKE FORHOLDSREGLER
Advarsel: RISIKO FOR ELEKTRISK STØD
For at forebygge ELEKTRISK stød, undlad at åbne apparatet. Der er ingen indre dele, der kan repareres af brugeren. Denne enhed indeholder LIVSFARLIGE STRØMSPÆNDINGER og bør kun åbnes af en uddannet og kvalificeret tekniker. For at undgå risiko for ELEKTRISK STØD, afbrydes den elektriske strøm til produktet, før LAN-kablerne monteres eller afmonteres.
$ 10 Dette er et PRODUKT UNDER KLASSE 1 LED
$ 11 FARE UNDER UVEJR
Fare: UNDLAD at arbejde på udstyr eller KABLER i perioder med LYNAKTIVITET.
$ 12 Waarschuwing: Het toestel wordt uitgeschakeld door de stroomkabel te
ontkoppelen. Om het toestel stroomloos te maken: de stroomkabel ontkoppelen.
$ 13 Aan te sluiten apparatuur, de contactdoos wordt in de nabijheid van de apparatuur
geïnstalleerd en is gemakkelijk te bereiken."
$ 14 Opgelet: De ventilatiegaten mogen niet worden gesperd en moeten de
omgevingslucht ongehinderd toelaten voor afkoeling
$ 15 Strømforsyningen til apparatet må udelukkende tages fra
tilpasningstransformatoren.
EUROPE - EU
Brug kun TÜV godkendt vekselstrømstransformator på 3.3V jævnstrøm, 1.5A.
$ 16 Betjeningstemperatur: Dette apparat er konstrueret til en omgivende temperatur
på maksimum 40 grader C.
$ 17 Alle Lande: Installation af produktet skal ske i overensstemmelse med lokal og
national lovgivning for elektriske installationer.
Eisen: Dit product voldoet aan de volgende eisen.
$ 1 RFI Emissie EN55022 Klasse B
$ 2 Waarschuwing: Binnenshuis kan dit product radiostoring veroorzaken, in welk
geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen.
$ 3 Immuniteit EN55024
$ 4 Waarschuwing: Om te voldoen aan de emissie- en immuniteitsnormen dient dit
apparaat te zijn voorzien van afgeschermde kabels. Als het met niet-afgeschermde kabels wordt gebruikt, kan het zijn dat de gebruiker maatregelen moet treffen om interferentieproblemen voor eigen rekening op te lossen.
$ 5 Electrische Veiligheid EN60950 (TUV), UL1950 (UL/cUL)
$ 6Laser EN60825
VEILIGHEID
$ 7 Waarshuwing Klasse-1 laser produkt.
$ 8 Waarchuwing Neit in de straal staren.
$ 9 ELEKTRISKE FORHOLDSREGLER
Advarsel: RISIKO FOR ELEKTRISK STØD For at forebygge ELEKTRISK stød, undlad at åbne apparatet. Der er ingen indre dele, der kan repareres af brugeren. Denne enhed indeholder LIVSFARLIGE
25
Page 36
Electrical Safety and Ins tallation Requiremen t s
STRØMSPÆNDINGER og bør kun åbnes af en uddannet og kvalificeret tekniker. For at undgå risiko for ELEKTRISK STØD, afbrydes den elektriske strøm til produktet, før LAN-kablerne monteres eller afmonteres.
$ 10 Dit is een KLASSE 1 LED-PRODUKT
$ 11 GEVAAR VOOR BLIKSEMINSLAG
Gevaar: NIET aan toestellen of KABELS WERKEN bij BLIKSEM.
$ 12 Attention: Le cordon dalimentation sert de mise hors circuit. Pour couper
lalimentation du matériel, débrancher le cordon.
$ 13 Equipement pour branchement electrique, la prise de sortie doit être placée près de
l’équipement et facilement accessible".
$ 14 Attention: Ne pas bloquer les fentes daération, ceci empêcherait lair ambiant de
circuler librement pour le refroidissement
$ 15 Stroom mag alleen via de adapter naar het apparaat toegevoerd worden.
EUROPE - EU
Gebruik een door TÜV gekeurde wisselstroomadapter van 3.3 Volt gelijkstroom, 1.5 milliampères.
$ 16 Bedrijfstemperatuur: De omgevingstemperatuur voor dit produkt mag niet meer
bedragen dan 40 graden Celsius.
$ 17 Alle Landen: het toestel installeren overeenkomstig de lokale en nationale
elektrische voorschriften.
Normes: ce produit est conforme aux normes de suivantes.
$ 1 Emission d'interférences
radioélectriques EN55022 Classe
B
$ 2Mise En Garde: dans un environnement domestique, ce produit peut provoquer des
interférences radioélectriques. Auquel cas, l'utilisateur devra prendre les mesures adéquates.
$ 3 Immunité EN55024
$ 4 Avertissement : Il faut utiliser des câbles blindés pour ce produit afin de respecter
les normes d’émission et d’immunité. Si lutilisateur choisit dutiliser des câbles non blindés, il sera peut-être contraint de prendre les mesures nécessaires pour corriger les problèmes d’interférences, ainsi que dassumer le coût correspondant.
$ 5Sécurité électrique EN60950 (TUV), UL1950 (UL/cUL)
$ 6Laser EN60825
SÉCURITÉ
$ 7 Attention Producit laser di classe 1.
$ 8 Attention Ne pas fixer le faisceau des yeux. $ 9 INFORMATION SUR LES RISQUES ÉLECTRIQUES
L
AVERTISSEMEN
Pour éviter toute ÉLECTROCUTION, ne pas ôter le revêtement protecteur du matériel. Ce matériel ne contient aucun élément réparable par lutilisateur. Il comprend des TENSIONS DANGEREUSES et ne doit
: DANGER D’ÉLECTROCUTION
26
Page 37
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
être ouvert que par un technicien dûment qualifié. Pour éviter tout risque d’ÉLECTROCUTION, débrancher le matériel avant de connecter ou de déconnecter les câbles LAN.
$ 10 Ce matriel est un PRODUIT A DIODE LECTROLUMINESCENTE DE CLASSE 1
$ 11 DANGER DE FOUDRE
Danger: NE PAS MANIER le matériel ou les CÂBLES lors d'activité orageuse.
$ 12 Attention: Le cordon dalimentation sert de mise hors circuit. Pour couper
lalimentation du matériel, débrancher le cordon.
$ 13 EQUIPEMENT POUR BRANCHEMENT ELECTRIQUE, la prise de sortie doit être
placée près de l’équipement et facilement accessible".
$ 14 Attention: Ne pas bloquer les fentes d’aération, ceci empêcherait lair
ambiant de circuler librement pour le refroidissement.
$ 15 L'alimentation du concentrateur doit être uniquement fournie par l'adaptateur.
EUROPE - EU
Utiliser un adaptateur secteur conforme TÜV de 3.3V, 1.5A en courant continu.
$ 16 TEMPÉRATURE DE FONCTIONNEMENT
Ce matériel est capable de tolérer une température ambiante maximum de 40 degrés Celsius.
$ 17 POUR TOUS PAYS: Installer le matériel conformément aux normes électriques
nationales et locales.
Standardit: Tämä tuote on seuraavien standardien mukainen.
$ 1 Radioaaltojen häirintä EN55022 Luokka B
$ 2Varoitus: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä
tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin.
$ 3Kestävyys EN55024
$ 4Varoitus: Tämä tuote vaatii suojattuja kaapeleita toimiakseen emissio- ja
häiriönsietostandardien mukaisesti. Jos tuotetta käytetään ilman suojattuja kaapeleita, käyttäjä voi joutua korjaamaan häirinnän aiheuttaman ongelman omalla kustannuksellaan.
$ 5Sähköturvallisuus EN60950 (TUV), UL1950 (UL/cUL)
$ 6Laser EN60825
TURVALLISUUS
$ 7Varoitus Luokan 1 Lasertuote.
$ 8Variotus Älä katso säteeseen. $ 9 SÄHKÖÖN LIITTYVIÄ HUOMAUTUKSIA
VAROITUS: S ÄHKÖISKUVAARA Estääksesi SÄHKÖISKUN älä poista kantta. Sisällä ei ole käyttäjän huollettavissa olevia osia. Tämä laite sisältää VAARALLISIA JÄNNITTEITÄ ja sen voi avata vain koulutettu ja pätevä teknikko. Välttääksesi SÄHKÖISKUN mahdollisuuden katkaise sähkövirta tuotteeseen ennen kuin liität tai irrotat paikallisverkon (LAN) kaapelit.
$ 10 Tämä on ENSIMMÄISEN LUOKAN VALODIODITUOTE
27
Page 38
Electrical Safety and Ins tallation Requiremen t s
$ 11 SALAMANISKUVAARA
ENGENVAARA: ÄLÄ TYÖSKENTELE laitteiden tai KAAPELEIDEN KANSSA
SALAMOINNIN AIKANA.
$ 12 HUOMAUTUS: VIRTAJOHTOA KÄYTETÄÄN VIRRANKATKAISULAITTEENA.
VIRTA KATKAISTAAN irrottamalla virtajohto.
$ 13 PISTORASIAAN KYTKETTÄVÄ LAITE; pistorasia on asennettava laitteen lähelle
ja siihen on oltava esteetön pääsy."
$ 14 HUOMAUTUS: Ilmavaihtoreikiä ei pidä tukkia ja niillä täytyy olla vapaa yhteys
ympäröivään huoneilmaan, jotta ilmanvaihto tapahtuisi.
$ 15 Tähtipisteeseen (hub) syötettävän virran pitää tulla ainoastaan sovittimesta.
EUROPE - EU
Käytä TÜV-lisenssillä valmistettua verkkosovitinta, jonka tasajännitteen nimellisarvot ovat DC 3.3V, 1.5A (milliampeeria).
$ 16 KÄYTTÖLÄMPÖTILA
Tämä tuote on suunniteltu ympäröivän ilman maksimilämpötilalle 40° C.
$ 17 KAIKKI MAAT: Asenna tuote paikallisten ja kansallisten
sähköturvallisuusmääräysten mukaisesti.
Standard: Questo prodotto è conforme ai seguenti standard.
$ 1 Emissione RFI (interferenza di
radiofrequenza) EN55022 Classe
B
$ 2Avvertenza: in ambiente domestico questo prodotto potrebbe causare radio
interferenza. In questo caso potrebbe richiedersi all'utente di prendere gli adeguati provvedimenti.
$ 3 Immunità EN55024
$ 4Avvertenza: questo prodotto, se utilizzato con cavi schermati, è conforme alle
norme sulle emissioni e sull’immunità. In caso di uso senza cavi schermati, l’utente può dover adottare a proprie spese misure correttive contro le interferenze.
$ 5 Sicurezza elettrica EN60950 (TUV), UL1950 (UL/cUL)
$ 6Laser EN60825
NORME DI SICUREZZA
$ 7Avvertenza Prodotto laser di Classe 1.
$ 8Avertenza Non fissare il raggio con gli occhi. $ 9 AVVERTENZE ELETTRICHE
ATTENZIONE: PERICOLO DI SCOSSE ELETTRICHE Per evitare SCOSSE ELETTRICHE non asportare il coperchio. Le componenti interne non sono riparabili dallutente. Questa unità ha TENSIONI PERICOLOSE e va aperta solamente da un tecnico specializzato e qualificato. Per evitare ogni possibilità di SCOSSE ELETTRICHE, interrompere lalimentazione del dispositivo prima di collegare o staccare i cavi LAN.
$ 10 Questo è un PRODOTTO CON LED DI CLASSE 1
$ 11 PERICOLO DI FULMINI
Pericolo: NON LAVORARE sul dispositivo o sui CAVI durante PRECIPITAZIONI TEMPORALESCHE.
28
Page 39
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
$ 12 Attenzione: Il cavo di alimentazione è usato come dispositivo di disattivazione. Per
togliere la corrente al dispositivo staccare il cavo di alimentazione.
$ 13 APPARECCHIATURA COLLEGABILE, la presa va installata vicino allapparecchio
per risultare facilmente accessibile".
$ 14 ATTENZIONE: le prese daria non vanno ostruite e devono consentire il libero
ricircolo dellaria ambiente per il raffreddamento.
$ 15 Questo dispositivo deve essere alimentato solo mediante ladattatore.
EUROPE - EU
Utilizzare ladattatore per c.a. da 3.3V c.c. e 1.5A conforme alla normativa TÜV.
$ 16 TEMPERATURA DI FUNZIONAMENTO
Questo prodotto è concepito per una temperatura ambientale massima di 40 gradi centigradi.
$ 17 TUTTI I PAESI: installare il prodotto in conformità delle vigenti normative
elettriche nazionali.
Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer.
$ 1 RFI stråling EN55022 Klasse B
$ 2 Advarsel: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake
radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler.
$ 3 Immunitet EN55024
$ 4 Advarsel: Dette produktet må brukes med vernede kabler for å tilfredsstille
emisjons- og fritakelsesstandarder. Dersom produktet brukes med uvernede kabler, må brukeren muligens rette forstyrrelsesproblemene for egen regning.
$ 5 Elektrisk sikkerhet EN60950 (TUV), UL1950 (UL/cUL)
$ 6Laser EN60825
SIKKERHET
$ 7ADVARSEL Laserprodukt av klasse 1.
$ 8ADVARSAL Stirr ikke på strålen. $ 9 ELEKTRISITET
Advarsel: FARE FOR ELEKTRISK SJOKK For å unngå ELEKTRISK sjokk, må dekslet ikke tas av. Det finnes ingen deler som brukeren kan reparere på innsiden. Denne enheten inneholder FARLIGE SPENNINGER, og må kun åpnes av en faglig kvalifisert tekniker. For å unngå ELEKTRISK SJOKK må den elektriske strømmen til produktet være avslått før LAN-kablene til- eller frakobles.
$ 10 Dette er et KLASSE 1 LED PRODUKT
$ 11 FARE FOR LYNNEDSLAG
FARE: ARBEID IKKE på utstyr eller KABLER i TORDENVÆR.
$ 12 Forsiktig: STRØMLEDNINGEN BRUKES TIL Å FRAKOBLE UTSTYRET. FOR
Å DEAKTIVISERE UTSTYRET, må strømforsyningen kobles fra.
$ 13 UTSTYR FOR STIKKONTAKT. Stikkontakten skal monteres i nærheten av
utstyret og skal være lett tilgjengelig."
$ 14 Forsiktig: Lufteventilene må ikke blokkeres, og må ha fri tilgang til luft med
romtemperatur for avkjøling.
$ 15 All strømtilførsel må komme fra adapteren.
29
Page 40
Electrical Safety and Ins tallation Requiremen t s
EUROPE - EU
Benytt TÜV-godkjent AC-adapter på 3.3V DC, 1.5A (millismpere)
$ 16 DRIFTSTEMPERATUR
Dette produktet er konstruert for bruk i maksimum romtemperatur på 40 grader celsius.
$ 17 ALLE LAND: Produktet må installeres i samsvar med de lokale og nasjonale
elektriske koder.
Padrões: Este produto atende aos seguintes padrões.
$ 1Emissão De Interferência De
Radiofrequência EN55022 Classe
B
$ 2Aviso: Num ambiente doméstico este produto pode causar interferência na
radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas.
$ 3 Imunidade EN55024
$ 4Advertência: Este produto requer a utilização de cabos blindados para
cumprimento dos standards de limites de emissão e imunidade. Se o produto for utilizado com cabos não blindados, o utilizador poderá necessitar de tomar medidas para correcção de problemas de interferência, por sua própria conta.
$ 5Segurança Eléctrica EN60950 (TUV), UL1950 (UL/cUL)
$ 6Laser EN60825
SEGURANÇA
$ 7Aviso Produto laser de classe 1.
$ 8Aviso Não olhe fixamente para o raio. $ 9 AVISOS SOBRE CARACTERÍSTICAS ELÉTRICAS
Atenção: PERIGO DE CHOQUE ELÉTRICO Para evitar CHOQUE ELÉTRICO, não retire a tampa. Não contém peças que possam ser consertadas pelo usuário. Este aparelho contém VOLTAGENS PERIGOSAS e só deve ser aberto por um técnico qualificado e treinado. Para evitar a possibilidade de CHOQUE ELÉTRICO, desconecte o aparelho da fonte de energia elétrica antes de conectar e desconectar os cabos da LAN.
$ 10 Este é um PRODUTO CLASSE 1 LED
$ 11 PERIGO DE CHOQUE CAUSADO POR RAIO
PERIGO: NÃO TRABALHE no equipamento ou nos CABOS durante períodos suscetíveis a QUEDAS DE RAIO.
$ 12 Cuidado: O cabo de alimentação é utilizado como um dispositivo de desconexão.
Para deseletrificar o equipamento, desconecte o cabo de alimentação.
$ 13 EQUIPAMENTO DE LIGAÇÃO, a tomada eléctrica deve estar instalada perto do
equipamento e ser de fácil acesso."
$ 14 Cuidado: As aberturas de ventilação não devem ser bloqueadas e devem ter acesso
livre ao ar ambiente para arrefecimento adequado do aparelho.
$ 15 Use somente o adaptador fornecido para alimentação elétrica do hub.
EUROPE - EU
Use um adaptador de corrente alternada com saída DC de 3.3V e 1.5A em conformidade com as especificações da TÜV.
30
Page 41
AT-FS21x and AT-FS212/x Series In st al l a tion G ui de
$ 16 TEMPERATURA DE FUNCIONAMENTO
Este produto foi projetado para uma temperatura ambiente máxima de 40 graus centígrados.
$ 17 TODOS OS PAÍSES: Instale o produto de acordo com as normas nacionais e locais
para instalações elétricas.
Estándares: Este producto cumple con los siguientes estándares.
$ 1Emisión RFI EN55022 Clase B
$ 2Advertencia: en un entorno doméstico, este producto puede causar
radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto.
$ 3 Inmunidad EN55024
$ 4Advertencia: Este producto exige cables protectores para ajustarse a las normas de
emisión e inmunidad. Si se utiliza con cables sin protección, el usuario tendrá que correr con los gastos por las medidas a tomar en caso de problemas de interferencias.
$ 5Seguridad eléctrica EN60950 (TUV), UL1950 (UL/cUL)
$ 6Laser EN60825
SEGURIDAD
$ 7 ¡ADVERTENCIA! Producto láser Clase 1.
$ 8 ¡ADVERTENCIA! No mirat fijamente el haz. $ 9 AVISOS ELECTRICOS
Advertencia: PELIGRO DE ELECTROCHOQUE Para evitar un ELECTROCHOQUE, no quite la tapa. No hay ningún componente en el interior al cual puede prestar servicio el usuario. Esta unidad contiene VOLTAJES PELIGROSOS y sólo deberá abrirla un técnico entrenado y calificado. Para evitar la posibilidad de ELECTROCHOQUE desconecte la corriente eléctrica que llega al producto antes de conectar o desconectar los cables LAN.
$ 10 Este es un PRODUCTO DE DIODO LUMINISCENTE (LED) CLASE 1
$ 11 PELIGRO DE RAYOS
Eligro: NO REALICE NINGUN TIPO DE TRABAJO O CONEXION en los equipos o en LOS CABLES durante TORMENTAS ELECTRICAS.
$ 12 ATENCION: EL CABLE DE ALIMENTACION SE USA COMO UN
DISPOSITIVO DE DESCONEXION. PARA DESACTIVAR EL EQUIPO, desconecte el cable de alimentación.
$ 13 EQUIPO CONECTABLE, el tomacorriente se debe instalar cerca del equipo, en un
lugar con acceso fácil".
$ 14 ATENCION: Las aberturas para ventilación no deberán bloquearse y deberán tener
acceso libre al aire ambiental de la sala para su enfriamiento.
$ 15 La energía para el dispositivo central o "hub" debe provenir únicamente del
adaptador.
EUROPE - EU
Utilizar un adaptador de corriente alterna autorizado TÜV de 3.3 voltios de corriente continua y 1.5 miliamperios.
$ 16 TEMPERATURA REQUERIDA PARA LA OPERACIÓN
Este producto está diseñado para una temperatura ambiental máxima de 40 grados C.
31
Page 42
Electrical Safety and Ins tallation Requiremen t s
$ 17 PARA TODOS LOS PAÍSES: Monte el producto de acuerdo con los Códigos
Eléctricos locales y nacionales.
Standarder: Denna produkt uppfyller följande standarder.
$ 1Radiostörning EN55022 Klass B
$ 2 Varning: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan
tvinga användaren till att vidtaga erforderliga åtgärder.
$ 3 Immunitet EN55024
$ 4 Varning! Denna produkt kräver skärmade kablar för att uppfylla standardkraven
för emission och immunitet. Om den används med oskärmade kablar kan användaren vara tvungen att vidta åtgärder på egen bekostnad för att åtgärda störningsproblemet.
$ 5Elsäkerhet EN60950 (TUV), UL1950 (UL/cUL)
$ 6Laser EN60825
SÄKERHET
$ 7 Varning! Laserprodukt av klass 1.
$ 8 Varning! Laserstrålning när enheten är öppen.
$ 9 TILLKÄNNAGIVANDEN BETRÄFFANDE ELEKTRICITETSRISK:
RISK FÖR ELEKTRISK STÖTFör att undvika ELEKTRISK stöt, ta ej av locket. Det finns inga delar inuti som behöver underhållas. Denna apparat är under HÖGSPÄNNING och får endast öppnas av en utbildad kvalificerad tekniker. För att undvika ELEKTRISK STÖT, koppla ifrån produktens strömanslutning innan LAN­kablarna ansluts eller kopplas ur.
$ 10 Detta är en KLASS 1 LYSDIODPRODUKT
$ 11 FARA FÖR BLIXTNEDSLAG
Fara: ARBETA EJ på utrustningen eller kablarna vid ÅSKVÄDER.
$ 12 Varning: Nätkabeln används som strömbrytare för att koppla från strömmen, dra
ur nätkabeln.
$ 13 UTRUSTNING MED PLUGG. Uttaget skall installeras i utrustningens närhet och
vara lättåtkomligt".
$ 14 VARNING: Luftventilerna får ej blockeras och måste ha fri tillgång till omgivande
rumsluft för avsvalning.
$ 15 Endast anslutningsenheten får vara kraftkälla till centralen.
EUROPE - EU
Använd en växelströmsanslutningsenhet licensierad av TÜV. Likström 3.3V, 1.5A.
$ 16 DRIFTSTEMPERATUR
Denna produkt är konstruerad för rumstemperatur ej överstigande 40 grader Celsius.
$ 17 ALLA LÄNDER: Installera produkten i enlighet med lokala och statliga
bestämmelser för elektrisk utrustning.
32
Page 43

Appendix C

Technical Support Fax Order

Name _________________________________________________________________ Company______________________________________________________________ Address _______________________________________________________________ City______________________ State/Province _______________________________ Zip/Postal Code ________________ Country _______________________________ Phone______________________________ Fax_______________________________

Incident Summary

Model number of Allied Telesyn product I am using _______________________ Network software products I am using ___________________________________
______________________________________________________________________
Brief summary of problem ______________________________________________
______________________________________________________________________
Conditions (List the steps that led up to the problem.) _____________________
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
Detailed description (Use separate sheet, if necessary)
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
When completed, fax this sheet to the appropriate Allied Telesyn office. Fax numbers can be found on page viii.
33
Page 44
Loading...