Allied Telesis AT-FS203 User Manual [en, de, es, fr, it]

AT-FS201 AT-FS201ST/FS1, FS2, FS3 AT-FS202 AT-FS202SC/FS1, FS2, FS3 AT-FS203
Fast Ethernet Switches
Installation Guide
PN 613-10761-00 Rev B
Copyright 2000 Allied Telesyn International, Corp. 960 Stewart Drive, Suite B, Sunnyvale CA 94086 USA
Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Allied Telesyn International, Corp. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allie Telesyn International, Corp. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesyn International, Corp. has been advised of, known, or should have known, the possibility of such damages.

Safety Warnings

Standards
RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
This Class A digital apparatus meets all requirements of the Canadian Interference­Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
RFI Emission Warning
case the user may be required to take adequate measures.
Immunity Warning
standards. If it is used with unshielded cables, the user may be required to take measures to correct the interference problem at their own expense.
Electrical Safety Laser Warning Warning
At time of installation, the Fiber Optic Lasers comply with FDA Radiation Performance Standard 21CFR Subchapter J, applicable at date of manufacture.
This is a “CLASS 1 LED PRODUCT” (AT-FS201, AT-FS202, AT-FS203 models)
Important
equipment. When you see the , go to Appendix B for the translated safety statement in your language.
Wichtig
Geräts. Wenn Sie  sehen, schlagen Sie in Anhang B den übersetzten Sicherheitshinweis in Ihrer Sprache nach.
Vigtigt
dette udstyr. Når De ser symbolet , skal De slå op i tillæg B og finde de oversatte sikkerhedsadvarsler i Deres eget sprog.
Belangrijk
deze apparatuur. Wanneer u de  ziet, raadpleeg Appendix B voor vertaalde veiligheidsinstructies in uw taal.
: This product meets the following standards
U.S. Federal Communications Commission
Industry Canada
6
4
1
2
3
5
9
EN55022 Class A
: In a domestic environment this product may cause radio interference in which
EN50082-1 1997
: This product requires shielded cables to comply with emission and immunity
EN60950, UL1950, CSA 950 EN60825
7
Class 1 Laser product. Do not stare into the Laser beam.
: Appendix B contains translated safety statements for installing this
: Anhang B enthält übersetzte Sicherheitshinweise für die Installation dieses
: Tillæg B indeholder oversatte sikkerhedsadvarsler, der vedrører installation af
: Appendix B bevat vertaalde veiligheidsopmerkingen voor het installeren van
8
iii
Safety Warnings
Important
équipement. Lorsque vous voyez le symbole , reportez-vous à l'annexe B pour consulter la traduction de ces instructions dans votre langue.
Tärkeää
Kun näe-symbolin, katso käännettyä turvaohjetta liitteestä B.
Importante
questa apparecchiatura. Il simbolo , indica di consultare l’Appendice B per l’avviso di sicurezza nella propria lingua.
Viktig
utstyret. Når du ser , åpner du til Tillegg B for å finne den oversatte sikkerhetsinformasjonen på ønsket språk.
Importante
equipamento. Quando vir o símbolo , leia a advertência de segurança traduzida no seu idioma no Anexo B.
Importante
instalación de este equipo. Cuando vea el símbolo , vaya al Apéndice B para ver el mensaje de seguridad traducido a su idioma.
Obs
denna utrustning. När du ser , skall du gå till Bilaga B för att läsa det översatta säkerhetsmeddelandet på ditt språk.
: L'annexe B contient les instructions de sécurité relatives à l'installation de cet
: Liite B sisältää tämän laitteen asentamiseen liittyvät käännetyt turvaohjeet.
: l’Appendice B contiene avvisi di sicurezza tradotti per l’installazione di
: Tillegg B inneholder oversatt sikkerhetsinformasjon for installering av dette
: O Anexo B contém advertências de segurança traduzidas para instalar este
: El Apéndice B contiene mensajes de seguridad traducidos para la
! Bilaga B innehåller översatta säkerhetsmeddelanden avseende installationen av
iv

Table of Contents

Safety Warnings Table of Contents Welcome to Allied Telesyn
Where to Find Web-based Guides ................................................................... vii
Document Conventions .................................................................................... vii
Contacting Allied Telesyn...............................................................................viii
Online Support ......................................................................................... viii
For Technical Support and Services........................................................ viii
Technical Support E-mail Addresses ...................................................... viii
Returning Products ........................................................................................... ix
FTP Server......................................................................................................... ix
For Sales or Corporate Information .................................................................. x
Tell Us What You Think .................................................................................... x
Chapter 1 Description
Key Features....................................................................................................... 6
Switch Performance .................................................................................... 7
Status LEDs ................................................................................................ 8
External AC/DC Power Adapter................................................................. 8
MDI/MDI-X Switch ..................................................................................... 9
Configuration Switches............................................................................... 9
Functional Description..................................................................................... 10
Frame Processing ...................................................................................... 10
Address Recognition and Filtering........................................................... 10
Network Topologies.......................................................................................... 11
............................................................................................iii
........................................................................................... v
......................................................................... vii
...................................................................................................... 1
Chapter 2 Installing the Switch
Verifying the Package Contents ...................................................................... 13
Planning the Installation................................................................................. 14
Selecting a Site ................................................................................................. 16
Installing the Switch........................................................................................ 17
Warranty Registration ..................................................................................... 20
Troubleshooting................................................................................................ 20
Is the Switch Receiving Power?................................................................ 20
Connectivity Testing ................................................................................. 21
................................................................................... 13
v
Table of Contents
Is the Link LED Lit? ................................................................................. 21
Technical Support and Service ........................................................................ 22
Appendix A Technical Specifications
............................................................................ 23
Pinout Assignments.......................................................................................... 26
Appendix B Electrical Safety and Installation Requirements
.................................27
Appendix C Technical Support Fax Order
................................................................... 37
Incident Summary............................................................................................ 37
Appendix D AT-FS201, AT-FS202 and AT-FS203 Series
Installation Guide Feedback
..................................................................... 39
vi

Welcome to Allied Telesyn

This guide contains instructions on how to install the AT-FS201, AT-FS202, and AT-FS203 Series of Fast Ethernet Switches.

Where to Find Web-based Guides

The Allied Telesyn web site at easy way to access the most recent documentation and technical information for all of our products. For product guides, you can go directly to the following web page:
www.alliedtelesyn.com/support/lib_allproducts.htm
www.alliedtelesyn.com
provides you with an
.

Document Conventions

This guide uses several conventions that you should become familiar with first before you begin to install the product.
Note
A note provides additional information.
Caution
A caution indicates that performing or omitting a specific action may result in equipment damage or loss of data.
Warning
A warning indicates that performing or omitting a specific action may result in bodily injury.
vii
Welcome to Allied Telesyn

Contacting Allied Telesyn

There are several ways to contact Allied Telesyn technical support: online, telephone, fax, and e-mail.

Online Support

You can request technical support online by filling out the Tech-Assistant Form at

For Technical Support and Services

www.alliedtelesyn.com/support.htm
.
Americas
United States, Canada, Mexico, Central America, South America Tel: 1 (800) 428-4835, option 4 Fax: 1 (503) 639-3176
Asia
Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India, Hong Kong Tel: (+65) 381-5612 Fax: (+65) 383-3830
Australia
Tel: 1 (800) 000-880 Fax: (+61) 2-9438-4966
France
France, Belgium, Luxembourg, The Netherlands, Middle East, Africa Tel: (+33) 0-1-60-92-15-25 Fax: (+33) 0-1-69-28-37-49

Technical Support E-mail Addresses

United States and Canada
TS1@alliedtelesyn.com
Germany
Germany, Switzerland, Austria, Eastern Europe Tel: (+49) 0130/83-56-66 Fax: (+49) 30-435-900-115
Italy
Italy, Spain, Portugal, Greece, Turkey, Israel Tel: (+39) 02-416047 Fax: (+39) 02-419282
Japan
Tel: (+81) 3-3443-5640 Fax: (+81) 3-3443-2443
United Kingdom
United Kingdom, Denmark, Norway, Sweden, Finland Tel: (+0044) 1235-442500 Fax: (+44) 1-235-442680
Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands
latin_america@alliedtelesyn.com
United Kingdom, Sweden, Norway, Denmark, and Finland
support_europe@alliedtelesyn.com
viii
AT-FS200 Series Installation Guide

Returning Products

Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
To obtain an RMA number, contact Allied Telesyn’s Technical Support at one of the following locations:
North America
2205 Ringwood Ave San Jose, CA 95131 Tel: 1-800-428-4835, option 4 Fax: 1-503-639-3716
Latin America, the Caribbean, Virgin Islands
Tel: international code + 425-481-3852 Fax: international code + 425-483-9458
European Customer Support Centre
10/11 Bridgemead Close Westmead Industrial Estate Swindon, Wiltshire SN5 7YT England Tel: +44-1793-501401 Fax: +44-1793-431099
Mexico and Puerto Rico
Tel: 1-800-424-5012, ext 3852 or
1-800-424-4284, ext 3852 Mexico only:95-800-424-5012, ext 3852 Fax: international code + 425-489-9191

FTP Server

If you need a device driver for an Allied Telesyn device, such as an AT-8224XL Fast Ethernet Switch, you can download the driver from our FTP server at
ftp://gateway.centre.com
.
At login, enter ‘anonymous’. Enter your e-mail address for the password as requested by the server at login.
ix
Welcome to Allied Telesyn

For Sales or Corporate Information

Allied Telesyn International, Corp.
19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191
Allied Telesyn International, Corp.
960 Stewart Drive, Suite B Sunnyvale, CA 94086 Tel: 1 (800) 424-4284 (USA and Canada) Fax: 1 (408) 736-0100

Tell Us What You Think

If you have any comments or suggestions on how we might improve this or other Allied Telesyn documents, you can fill out the “AT-FS201, AT-FS202 and AT-FS203 Series Installation Guide Feedback” on page 39 and return the form to us at the address or fax number provided. You can also provide feedback online by filling out the Feedback on Documentation form at
www.alliedtelesyn.com/forms/feedbackman.htm
.
x

Chapter 1

Description

The AT-FS201, AT-FS202, and AT-FS203 Series of Fast Ethernet Switches are designed to interconnect LAN devices and subnetworks over large distances into an integrated network. These dual-port switches can also be used to improve the performance of your network by dividing it into smaller, more manageable segments.
The AT-FS201 and AT-FS202 Switches feature one 10/100Base-TX twisted pair port with an operating distance of 100 meters (328 feet), and a 100Base-FX fiber optic port with an operating distance of 2 kilometers (1.2 miles) to 75 kilometers (46.5 miles), depending on the model.
The AT-FS203 Switch features two 10/100Base-TX ports, each with a maximum distance of 100 meters (328 feet).
These Fast Ethernet switches can be installed either as standalone units, such as on a table, or in an AT-MCR12 or AT-TRAY4 Chassis. They are easy to install and do not require software configuration or management. The following figures illustrate the front and rear panels of each switch.
AUTO N EG
TX
RX
COL
LNK
100
FD
TX RX
10Base-T/ 100Base-TX
MDI MDI-X
FS201 FAST ETHERNET SWITCH
Figure 1
10Base-T/
100Base-TX
MDI MDI-X
PORT 2PORT 1
IEEE 802.3 / 802.3U
AT-FS201 Front Panel
AUTO N EG
TX
RX
COL
PWR
LNK
100
FD
1
Description
AUTO NEG
TX
RX
COL
LNK
100
FD
TX RX
10Base-T/ 100Base-TX
MDI MDI-X
FS202 FAST ETHERNET SWITCH IEEE 802.3 / 802.3U
AT-FS202 Front Panel
10Base-T/ 100Base-TX
MDI MDI-X
AUTO NEG
TX
RX
COL
LNK
100
FD
Figure 2
FS203 FAST ETHERNET SWITCH
Figure 3
AT-FS203 Front Panel
10Base-T/
100Base-TX
MDI MDI-X
PORT 2PORT 1
10Base-T/
100Base-TX
MDI MDI-X
PORT 2PORT 1
IEEE 802.3 / 802.3U
AUTO NEG
TX
RX
COL
AUTO N EG
TX
RX
COL
PWR
LNK
100
FD
PWR
LNK
100
FD
PORT
21 1212
321 4567
DUPLEX
12 V DC
Figure 4
SPEED (Mbps)
10 100
Rear Panel of the AT-FS203 Switch
MODE
HALF FULL
AUTO
NEG
OFF ON
BYTES
1522 1518
2
AT-FS201ST/FS1
AT-FS200 Series Installation Guide
100Base-FX
LNK
TX
100
RX
FD
COL
FS201ST/FS1 FAST ETHERNET SWITCH
AT-FS201ST/FS2
100Base-FX
LNK
TX
100
RX
FD
COL
FS201ST/FS2 FAST ETHERNET SWITCH
AT-FS201ST/FS3
100Base-FX
LNK
TX
100
RX
FD
COL
TX RX
TX RX
TX RX
CLASS 1
LASER PRODUCT
DO NOT STARE
INTO BEAM
CLASS 1
LASER PRODUCT
DO NOT STARE
INTO BEAM
CLASS 1
LASER PRODUCT
DO NOT STARE
INTO BEAM
10Base-T/
100Base-TX
MDI MDI-X
IEEE 802.3 /802.3U
10Base-T/
100Base-TX
MDI MDI-X
IEEE 802.3 /802.3U
10Base-T/
100Base-TX
MDI MDI-X
AUTO NEG
TX
RX
COL
PORT 2PORT 1 SINGLE MODE
AUTO NEG
TX
RX
COL
PORT 2PORT 1 SINGLE MODE
AUTO NEG
TX
RX
COL
PORT 2PORT 1 SINGLE MODE
PWR
LNK
100
FD
PWR
LNK
100
FD
PWR
LNK
100
FD
FS201ST/FS3 FAST ETHERNET SWITCH
Figure 5
AT-FS201ST Series Front Panel
IEEE 802.3 /802.3U
3
Description
AT-FS202SC/FS1
100Base-FX
LNK
TX
100
RX
FD
COL
FS202SC/FS1 FAST ETHERNET SWITCH
AT-FS202SC/FS2
100Base-FX
LNK
TX
100
RX
FD
COL
FS202SC/FS2 FAST ETHERNET SWITCH
AT-FS202SC/FS3
100Base-FX
LNK
TX
100
RX
FD
COL
TX RX
TX RX
TX RX
CLASS 1
LASER PRODUCT
DO NOT STARE
INTO BEAM
100Base-TX
MDI MDI-X
IEEE 802.3 /802.3U
CLASS 1
LASER PRODUCT
DO NOT STARE
INTO BEAM
100Base-TX
MDI MDI-X
IEEE 802.3 /802.3U
CLASS 1
LASER PRODUCT
DO NOT STARE
INTO BEAM
100Base-TX
MDI MDI-X
10Base-T/
10Base-T/
10Base-T/
AUTO NEG
TX
RX
COL
PORT 2PORT 1 SINGLE MODE
AUTO NEG
TX
RX
COL
PORT 2PORT 1 SINGLE MODE
AUTO NEG
TX
RX
COL
PORT 2PORT 1 SINGLE MODE
PWR
LNK
100
FD
PWR
LNK
100
FD
PWR
LNK
100
FD
FS202SC/FS3 FAST ETHERNET SWITCH
Figure 6
AT-FS202SC Series Front Panels
IEEE 802.3 /802.3U
4
AT-FS200 Series Installation Guide
Figure 7 illustrates the rear panel of the AT-FS201SC and AT-FS202ST Series Switches.
PORT
1222
21 345
DUPLEX
12 V DC
SPEED
(Mbps)
10 100
MODE
HALF FULL
AUTO
NEG
OFF ON
BYTES
1522 1518
Figure 7
Rear Panel of the AT-FS201SC and AT-FS202ST Switches
Table 1
Maximum Operating Distance
Type of Connector Maximum Distance
Model
Port 1 Port 2 Port 1 Port 2
AT-FS201 RJ-45 ST 100 m (328 ft) 2 km (1.2 mi)
AT-FS201ST/FS1 RJ-45 ST 100 m (328 ft) 15 km (9.3 mi)
AT-F201ST/FS2 RJ-45 ST 100 m (328 ft) 40 km (24.8 mi)
AT-FS201ST/FS3 RJ-45 ST 100 m (328 ft) 75 km (46.5 mi)
AT-FS202 RJ-45 SC 100 m (328 ft) 2 km (1.2 mi)
AT-FS202SC/FS1 RJ-45 SC 100 m (328 ft) 15 km (9.3 mi)
AT-FS202SC/FS2 RJ-45 SC 100 m (328 ft) 40 km (24.8 mi)
AT-FS202SC/FS3 RJ-45 SC 100 m (328 ft) 75 km (46.5 mi)
AT-FS203 RJ-45 RJ-45 100 m (328 ft) 100 m (328 ft)
5
Description

Key Features

The switches have the following key features:
LEDs for unit and port status
MDI/MDI-X switch
External AC/DC power adapters (North America, Continental Europe, or United Kingdom)
DIP switches for configuring the ports
Full- or half-duplex operation on both ports
ST or SC fiber optic connectors
Data packet forwarding and filtering at full wire speed (10 Mbps to 100 Mbps, 100 Mbps to 100 Mbps, and 10 Mbps to 10 Mbps)
Store and forward switching mode
Automatic address learning and aging
IEEE 802.3u compliant auto-negotiation
Standard, compact size for use on a tabletop or in an AT-MCR12 or AT-TRAY4 Chassis
6
AT-FS200 Series Installation Guide

Switch Performance

The switches perform at:
148,800 pps for 100 Mbps and 14,880 pps for 10 Mbps for full wire speed forwarding and filtering
200 Mbps maximum throughput in 100 Mbps, full-duplex mode
20 Mbps maximum throughput in 10 Mbps, full-duplex mode
Up to 8,192 unicast MAC addresses and unlimited multicast/ broadcast addresses
280 kib bytes (per port) packet buffer
Low latency 14.3 µs (64-byte packet, 100 Mbps full-duplex)
Note
For definitions of technical terms associated with Allied Telesyn products, refer to the Glossary on Allied Telesyn’s web site at
www.alliedtelesyn.com/support/gloss_a.htm
.
7
Description

Status LEDs

Table 2 defines the switch LEDs.
Table 2
LEDs
LED State Color Description
PWR ON Green Power is applied.
LNK ON Green Link established on the port.
100 ON
OFF
FD ON
Green The port is operating at 100 Mbps.
The port is operating at 10 Mbps.
Amber Full-duplex mode is enabled (two-way independent
transmission).
OFF
Half-duplex mode is enabled, indicating transmission only in one direction at a time.
AUTO NEG ON Green Auto-negotiation is enabled on the port.
TX ON Green Data is being transmitted on the port.
RX ON Green Data is being received on the port.
COL ON Amber The port is sensing a collision signal.

External AC/DC Power Adapter

The power adapter supplies 12V DC to the switch. Allied Telesyn supplies an approved safety compliant AC power adapter for the 120 and 240V AC versions with an unregulated output of 12V DC.
Figure 8
8
External AC/DC Power Adapter (North American version shown)
AT-FS200 Series Installation Guide
10Base T/ 100Base-TX
10Base-T/
100Base-TX
MDI MDI-X MDI MDI-X
PORT 2PORT 1

MDI/MDI-X Switch

The MDI/MDI-X (Media Dependent Interface/Media Dependent Interface with Crossover) switch, located on the front panel, is a straight-through or crossover cable selection switch. It enables the RJ-45 port to be connected to a repeater or DTE device without using a special crossover cable. The default setting of the switch is MDI-X, which means you can connect the RJ-45 port to a workstation or to any other DTE device that uses a straight-through cable. For the MDI configuration, slide the switch to the MDI position and connect the RJ-45 port to a repeater, hub, or switch using a straight-through cable. See Figure 9.
AUTO NEG
LNK
TX
100
RX
FD
COL
FS203 FAST ETHERNET SWITCH
10Base-T/ 100Base-TX
MDI MDI-X
10Base-T/
100Base-TX
MDI MDI-X
PORT 2PORT 1
IEEE 802.3/ 802.3U
Figure 9
AUTO NEG
PWR
LNK
TX
100
RX
FD
COL
MDI/MDI-X Switch

Configuration Switches

The configuration switches on the rear panel of the unit are used to configure the operating characteristics of the port, such as it’s port speed and duplex mode, and the maximum packet size allowed by the switch.
Configuring a 100Base-FX fiber optic port involves setting its duplex mode to either half- or full-duplex. Configuring a 10/100Base twisted pair port involves setting the speed and duplex mode. You can have the switch do this automatically through auto-negotiation or you can set these values manually.
The Byte switch controls the maximum packets size that the unit will allow. You can set the switch to either 1518 bytes, which is the normal Ethernet packet size or to 1522 bytes, which make the Ethernet unit compliant with the IEEE 802.1Q VLAN tagging standard.
9
Description

Functional Description

The AT-FS200 series of switches function as unmanaged dual-port switches.

Frame Processing

The switches support store and forward switching at Fast Ethernet full-wire speed either in 10 or 100 Mbps, half- or full-duplex mode. Packets entering each port are stored in buffers. After the full packet is received, it is forwarded or discarded depending on its destination address and error status. This ensures that only error-free data packets destined for another segment will be transferred across the switch, reducing network load. For example, if the packet entering from Port 1 is destined for an end station on Port 2, it will be forwarded if the Frame Check Sequence (FCS) is valid. If the packet from Port 1 is destined for an end station also attached to Port 1, then the packet is discarded.
The switch will discard CRC error, misaligned, runt, and under-sized/over­sized packets. When the packet has dribble bits at the end, the switch will truncate to octet boundary and check for a good FCS before forwarding.

Address Recognition and Filtering

Up to 8,192 MAC addresses can be stored in the MAC address table. The switch will learn all new addresses in real-time after power-up with its address self-learning mechanism. If the source address of an incoming packet is not found in the address table, the switch waits until the end of the packet to check for good CRC and then updates its MAC address table. Because the switch has Automatic Address Aging, if a source address entry in the table is not updated within five minutes, the entry is deleted from the table. The switch forwards multicast, broadcast, and unicast packets when the MAC address table size is exceeded.
10
AT-FS200 Series Installation Guide

Network Topologies

Figure 10 shows a network configuration where an AT-FS203 Switch is used to interconnect two small networks of stackable hubs.
AT-3624TR
AT-FH812u
AT-FH812u
AT-FH812u
Figure 10
AT-3624TR
AT-3624TR
AT-FS203
Typical Configuration Using the AT-FS203 Switch
11

Chapter 2

Installing the Switch

This chapter explains how to install the switch. The switch can be installed either as a standalone unit, such as on a table, or in an AT-MCR12 or AT-TRAY4 Chassis.

Verifying the Package Contents

Make sure the following items are included in your switch package. If any of the following items are missing or damaged, contact your sales representative.
AT-FS201, AT-FS202, or AT-FS203 Fast Ethernet Switch
Four protective feet (for standalone use only)
External AC/DC power adapter (North America, Continental Europe, or United Kingdom)
This installation guide
Warranty card
13
Installing the Switch

Planning the Installation

Be sure to observe the following guidelines when planning the installation of your Ethernet switch.
The end node connected to the fiber optic port on an AT-FS201ST or AT-FS202SC switch must be able to operate at 100 Mbps.
The end node connected to the twisted pair port(s) can operate at either 10 Mbps or 100 Mbps.
The end node connected to a port on the switch can be a network adapter card, repeater, router, hub, or another switch.
The twisted pair cabling must be kept away from sources of electrical noise, such as radios, transmitters, power lines, broadband amplifiers, electrical motor, and fluorescent fixtures.
Refer to Table 3 for the cabling specifications for the twisted pair port(s).
Table 3
Operating Mode Cable Type
10Base-T Shielded or unshielded Category 3 or better 100 m (328 ft)
100Base-TX Shielded or unshielded Category 5 or better 100 m (328 ft)
10/100Base-TX Twisted Pair Cabling Specifications
Maximum
Distance
14
AT-FS200 Series Installation Guide
Refer to Table 4 for the cabling specifications for the fiber optic port operating in full-duplex mode.
Table 4
Model
100Base-FX Fiber Optic Cabling Specifications (Full-duplex) for Port 2
Type of Fiber Optic Cable
AT-FS201 50/125 or
62.5/125 micron multimode
AT-FS201ST/FS1 50/125 or
62.5/125 micron multimode
9/125 micron single-mode
AT-F201ST/FS2 9/125 micron
single-mode
AT-FS201ST/FS3 9/125 micron
single-mode
AT-FS202 50/125 or
62.5/125 micron multimode
AT-FS202SC/FS1 50/125 or 62.5/
125 multimode
Maximum Distance
Maximum Allowable Loss Budget
2 km (1.2 mi) 13 dB at 1310 nm
2 km (1.2 mi) 13 dB at 1310 nm
15 km (9.3 mi) 16 dB at 1310 nm
40 km (24.8 mi) 30 dB at 1310 nm
75 km (46.5 mi) 33 dB at 1310 nm
2 km (1.2 mi) 13 dB at 1310 nm
2 km (1.2 mi) 13 dB at 1310 nm
9/125 micron
15 km (9.3 mi) 16 dB at 1310 nm
single-mode
AT-FS202SC/FS2 9/125 micron
40 km (24.8 mi) 30 dB at 1310 nm
single-mode
AT-FS202SC/FS3 9/125 micron
75 km (46.5 mi) 33 dB at 1310 nm
single-mode
Note
Refer to Appendix A for further information on the technical specifications of the fiber optic port on the switch.
15
Installing the Switch
Refer to Table 5 for the cabling specifications for the fiber optic port operating in half-duplex mode.
Table 5
100Base-FX Fiber Optic Ports (Half-duplex) For Port 2
1
Number of Media Converters
Connected Devices Maximum Distance
One Media Converter Inline Switch to switch 372 m (1,221 ft)
Workstation to switch 372 m (1,221 ft)
Switch to Class I repeater 137 m (450 ft)
Switch to Class II repeater 185 m (607 ft)
Two Media Converters
Switch to switch 332 m (1,089 ft)
Inline
Workstation to switch 322 m (1, 089 ft)
Switch to Class I repeater 97 m (318 ft)
Switch to Class II repeater 145 m (476 ft)
1. The total distance of the fiber optic lengths cannot exceed the limits stated in the table. Each media converter used inline within a single collision domain reduces the overall segment length by 40 m (131 ft).

Selecting a Site

Be sure to observe the following requirements when choosing a site for your switch.
Select a site that is dust-free and moisture-free.
Be sure that the site will allow you to easily access the fiber optic and twisted pair cables and the power cord.
Use dedicated power circuits or power conditioners to supply reliable power to the device.
16
AT-FS200 Series Installation Guide

Installing the Switch

To install the switch, perform the following procedures:
1. Remove all equipment from the package and store the packaging in a safe
place.
2. If you are installing the switch as a standalone unit, attach the four rubber
feet to the base of the unit, placing one rubber foot in each corner. (For rack-mount chassis installation, do not attach the feet.)
3. Configure the DIP switches on the rear panel of the unit. Refer to Figure
11 and Figure 12 for the location of the switches and Table 6 and Table 7 for the possible settings.
Table 6
DIP Switch Settings for the AT-FS201 and AT-FS202 Switches
Port 2 1 2 2
Speed (Mbps) Duplex Mode Auto-neg Bytes
Up 10 Half Off 1522
Down 100 Full On 1518
Table 7
DIP Switch Settings for the AT-FS203 Switch
Port 1 2 1 2 1 2
Speed (Mbps) Duplex Mode Auto-neg (only) Bytes
Up 10 Half Off 1522
Down 100 Full On 1518
17
Installing the Switch
When setting the DIP switches, consider the following:
The default setting of 1518 bytes for the maximum packet size is the upper limit of the allowable Ethernet packet size as specified in the IEEE 802.3 standard. At this setting, any packets over this size will be considered illegal and will be dropped as part of the switch’s error­handling operations.
Changing the setting of the maximum packet size to 1522 causes the switch to function as a passive component of the network in accordance with the IEEE 802.1Q VLAN tagging standard. The switch will pass packets that adhere to the standard. This 1522 setting should be used only in a network that uses the IEEE 802.1 Q VLAN tagging standard.
For a twisted pair port(s), setting the AUTO NEG switch to either ON or OFF either enables or disables auto-negotiation on the port. If you disable auto-negotiation, be sure to set the DIP switches for the port’s speed and duplex mode to match the speed and duplex mode of the end-node.
For a fiber optic port, set the port’s duplex mode using the appropriate DUPLEX MODE DIP switch. This setting must match the duplex mode capability of the end-node to be connected to the port.
PORT
21 1212
321 4567
DUPLEX
AUTO
SPEED
BYTES
MODE
NEG
12V DC
(Mbps)
10
HALF
OFF
1522
100
FULL
ON
1518
PORT
21 1212
321 4567
Figure 11
DUPLEX
SPEED (Mbps)
10 100
MODE
AT-FS203 DIP Switches
HALF FULL
AUTO
NEG
OFF ON
BYTES
1522 1518
18
12V DC
AT-FS200 Series Installation Guide
PORT
1222
21 345
DUPLEX
AUTO
SPEED
MODE
NEG
(Mbps)
BYTES
10
HALF
OFF
1522
100
FULL
ON
1518
PORT
1222
21 345
DUPLEX
MODE
HALF FULL
AUTO
NEG
OFF ON
BYTES
1522 1518
SPEED
(Mbps)
10 100
Figure 12
AT-FS201SC and AT-FS202ST DIP Switches
4. If you are installing the switch as a standalone unit, plug the AC/DC
power adapter into an appropriate AC power outlet and insert the power plug into the DC receptacle, located on the rear panel. If you are installing the switch in an AT-MCR12 or AT-TRAY4 Chassis, refer to the appropriate guide for installation instructions.
5. Verify that the PWR LED on the switch lights green.
6. For an AT-FS201 or AT-FS202 switch, remove the dust cover from the fiber
optic port.
7. For an AT-FS201 or AT-FS202 switch, plug the fiber optic cable into Port
1. Verify that the near-end node transmitter port (TX) is connected to the far end node receiver port (RX) and vice versa.
8. Plug the twisted pair cable(s) into the RJ-45 connector(s) (Port 2 for an
AT-FS201 or AT-FS202 switch and Ports 1 and 2 for the AT-FS203 switch).
9. Set the MDI/MDI-X switch as follows:
If you are connecting the twisted pair port to a workstation, set the MDI/MDI-X switch to the MDI-X position.
If you are connecting the twisted pair port to a hub or to another switch, set the MDI/MDI-X switch to the MDI position. See Figure 13.
19
Installing the Switch
10Base T/ 100Base-TX
10Base-T/
100Base-TX
MDI MDI-X MDI MDI-X
PORT 2PORT 1
AUTO NEG
LNK
TX
100
RX
FD
COL
FS203 FAST ETHERNET SWITCH
10Base-T/ 100Base-TX
MDI MDI-X
10Base-T/
100Base-TX
MDI MDI-X
PORT 2PORT 1
IEEE 802.3/ 802.3U
Figure 13
AUTO NEG
PWR
LNK
TX
100
RX
FD
COL
MDI/MDI-X Switch

Warranty Registration

When you finish the installation, register your product by completing the enclosed warranty card and sending it in, or by visiting our web site at
www.alliedtelesyn.com/forms/warranty.htm
and completing the on-line
registration.

Troubleshooting

This section contains guidelines for troubleshooting the unit should a problem occur.
Note
Whenever the speed and/or duplex mode are changed during or after power ON, power OFF then power back on the switch to load the new configuration.

Is the Switch Receiving Power?

Verify that the Power LED is lit.
If the Power LED is not ON, check the AC power adapter to verify that the adapter is plugged into a functioning wall outlet and that the DC power cord is properly inserted into the switch’s power connector.
20
AT-FS200 Series Installation Guide

Connectivity Testing

1. Connect each port to a node or workstation. Then connect the power cord.
2. Verify that the Link LEDs for Port 1 and Port 2 are lit.
If the Link LED does not light (TX):
Verify that the switch’s port matches the speed selection of the device attached to the other end.
The switch settings are represented by each port’s LEDs. For troubleshooting purposes, determine the current port settings, for example auto-negotiation, 10 or 100 Mbps (speed) duplex mode.
Change the MDI/MDI-X switch setting on the port and see if a link occurs. If not, put the switch back to its original configuration.
If the Link LED does not light (FX):
Make sure the remote end of the fiber optic cable is connected to a 100Base-FX device.
Swap the near end fiber cable receive/transmit connectors.

Is the Link LED Lit?

The Link LEDs light when a proper connection between the corresponding 10/ 100Base-TX or 100Base-FX port and the equipment connected to it is established. If this LED is not lit, check for the problems listed as follows and make corrections as necessary.
1. Problem 1:
The cable has been cut, damaged, or is the wrong type of cable.
Solution 1: — Try making the connection with a different cable. Be sure you are
using an undamaged cable of the correct type.
2. Problem 2:
Connected equipment is not turned ON or is not operating properly.
Solution 2: — Check the connected equipment (computer, another switch, etc.)
and turn ON the power.
— Make sure that the SPEED and Duplex Mode for each port of the
switch match the settings of the attached computer or additional switch.
21
Installing the Switch
3. Problem 3:
The MDI/MDI-X slide switch for TX is on the wrong setting.
Solution 3: — Verify that you are using a known good cable, reposition the MDI/
MDI-X switch, and check that the Link LED is lit.
4. Problem 4:
There is signal loss between the switch and one of the attached network nodes.
Solution 4: — Make sure the distance between the switch and the connected
network device does not exceed 100 meters (328 feet). (UTP is half­or full-duplex.)
— 412 meters (1,351 feet) for multi-mode fiber cable (half-duplex FX
operation/2 kilometers (1.2 miles) for full-duplex FX operation) See Table 8, “Technical Specifications,” on page 23 for correct distances for 10Base-T, 100Base-TX and 100Base-FX cable lengths.
Make sure you are using Category 5 cable when operating at 100 Mbps.

Technical Support and Service

You can contact the dealer where you purchased your product for local assistance. If local help is unable to resolve your problem, Allied Telesyn offers technical support via online, fax or telephone.
Refer to “Contacting Allied Teleysn” on page viii for technical support information or locations.
22
www.alliedtelesyn.com
for current world-wide office

Appendix A

Technical Specifications

Table 8 lists the technical specifications for the Fast Ethernet Switches.
Table 8
Physical Specifications
Dimensions (L x W x H) 10.5 cm x 9.5 cm x 2.5 cm
Weight 300 gm (10.5 oz)
Operating Temperatures 0° to 40° C
Storage Temperatures -20° to 80° C
Relative Humidity 5% to 80% (non-condensing)
Operating Altitude Up to 10,000 ft
Electrical and Mechanical Specifications
Standard CE Compliant IEEE 802.3, IEEE 802.3u
Immunity Conforms to EN500082-1 1997 immunity standard
Safety Conforms to all standards normally supported by Allied
EMI/RFI Meets all applicable requirements for emissions including
Electrical Rating
Technical Specifications
(4.12 in x 3.75 in 1.0 in)
Telesyn products including safety standards UL 1950, CSA
22.2 No. 950, TUV EN60950, EN60825 CE Compliant
but not limited to FCC Class A, IC Class A, EN55022 Class A
Input Supply Voltage 12V DC
Maximum Current Rating
Maximum Power Consumption
0.5A
6W
23
Technical Specifications
Table 8
Technical Specifications
Transmitter
Output Power 62.5/125 mM
-16.8 dBm 100/140 mM 50/125 mM
-20.3 dBm 85/125 mM
Fiber Optic Transmitter
Fiber Optic Diameter (microns)
Model
AT-FS201 & AT-FS202
AT-FS201ST/FS1 & AT-FS202SC/FS1
Table 9
Fiber Type
MMF 50/125 1310 nm -14.0 -20.3 -22.5
MMF 62.5/125 1310 nm -14.0 -16.8 -19.0
SMF 9/125 1310 nm -8.0 -11.5 -15.0
(Continued)
Optical Frequency (nm)
1
Launch Power (dBm)
Max. Avg Min.
AT-FS201ST/FS2 & AT-FS202SC/FS2
AT-FS201ST/FS3 & AT-FS202SC/FS3
1. The launch power is measured at one meter from the transmitter.
24
SMF 9/125 1310 nm 0.0 -3.0 -5.0
SMF 9/125 1310 nm 0.0 -2.0 -4.0
AT-FS200 Series Installation Guide
Table 10
Model
AT-FS201 & AT-FS202
AT-FS201ST/FS1 & AT-FS202SC/FS1
AT-FS201ST/FS2 & AT-FS202SC/FS2
AT-FS201ST/FS3 & AT-FS202SC/FS3
Fiber Type
MMF 50/125 1310 nm -31.8 -34.5 -14.0
MMF 62.5/125 1310 nm -31.8 -34.5 -14.0
SMF 9/125 1310 nm -31.0 -31.0 -8.0
SMF 9/125 1310 nm -35.0 -38.0 0.0
SMF 9/125 1310 nm -37.0 -37.0 -3.0
Table 11
Model Fiber Type
Fiber Optic Receiver
Fiber Optic Diameter (microns)
Fiber Optic Datalink
Min. Power / Link Budget (dB)
Optical Frequency (nm)
Avg. Signal Loss (dB)
Receive Power (dBm)
Min. Sensi­tivity
Typical Sensi­tivity
Min. Distance
1
Specs.
Satura­tion
Max. Distance Specs.
AT-FS201 & AT-FS202
AT-FS201ST/FS1 & AT-FS202SC/FS1
AT-FS201ST/FS2 & AT-FS202SC/FS2
AT-FS201ST/FS3 & AT-FS202SC/FS3
1. The recommended minimum range is stated in all cases where the maximum trans mitter output power exceeds the receivers saturation level. This is to prevent blind­ing or burning out of the optical receiver on the far-end node.
50/125 MMF 13.00 18.70 0 2 km
62.5/125 MMF
9/125 SMF 16.00 19.50 0 15 km
9/125 SMF 30.00 35.00 0 40 km
9/125 SMF 33.00 35.00 15 km
16.80 22.50 0 2 km
(9.4 mi)
(1.25 mi)
(1.25 mi)
(9.4 mi)
(25 mi)
75 km (46 mi)
25
Technical Specifications

Pinout Assignments

Figure 14 shows the pin assignments of the switch’s 10/100Base-TX RJ-45 connector.
Pin 1 Pin 8
Figure 14
RJ-45 Pin Assignments
Table 5 lists the 10/100Base-TX connector pins and their signals when the MDI-X/MDI switch is in either position.
Table 12
Pinout Assignments
MDI-X (Default) Signal MDI Signal
1RX+1 TX+
2RX-2 TX-
3TX+3 RX+
4- 4 -
5- 5 -
6TX-6 RX-
7- 7 -
8- 8 -
26

Appendix B

Electrical Safety and Installation Requirements

Important
safety statements in this guide.
Wichtig
enthaltenen Sicherheitshinweise in mehreren Sprachen.
Vigtigt
sikkerhedsadvarslerne i denne håndbog.
Belangrijk
veiligheidsopmerkingen in deze gids.
Important
instructions de sécurité figurant dans ce guide.
Tärkeää
kielellä.
Importante
di sicurezza di questa guida.
Viktig
sikkerhetsinformasjonen i denne veiledningen.
Importante
advertências de segurança neste guia.
Importante
mensajes de seguridad incluidos en esta guía.
: This appendix contains multiple-language translations for the
: Dieser Anhang enthält Übersetzungen der in diesem Handbuch
: Dette tillæg indeholder oversættelser i flere sprog af
: Deze appendix bevat vertalingen in meerdere talen van de
: Cette annexe contient la traduction en plusieurs langues des
: Tämä liite sisältää tässä oppaassa esiintyvät turvaohjeet usealla
: questa appendice contiene traduzioni in più lingue degli avvisi
: Dette tillegget inneholder oversettelser til flere språk av
: Este anexo contém traduções em vários idiomas das
: Este apéndice contiene traducciones en múltiples idiomas de los
Obs!
Denna bilaga innehåller flerspråkiga översättningar av
säkerhetsmeddelandena i denna handledning.
27
Electrical Safety and Installation Requirements
Standards
RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
1 RFI Emission
2 Warning
3 Immunity
4 Warning
5 Electrical Safety
6Laser
7 Warning
8 Warning
9
10 LIGHTNING DANGER
11
12
13 OPERATING TEMPERATURE
14
which case the user may be required to take adequate measures.
immunity standards. If it is used with unshielded cables, the user may be required to take measures to correct the interference problem at their own expense.
At time of installation, the Fiber Optic Lasers comply with FDA Radiation Performance Standard 21CFR Subchapter J, applicable at date of manufacture.
This is a “CLASS 1 LED PRODUCT” (AT-FS201, AT-FS202, AT-FS203 models)
SAFETY
DANGER
LIGHTNING ACTIVITY. DO NOT BLOCK AIR VENTS Power to the hub must be sourced only from the adapter.
USA/CANADA
Use a UL Listed/CSA Certified AC adapter of DC 12V, 500mA.
EUROPE - EU
Use TÜV licensed AC adapter of DC 12V, 500mA.
UK
Use a UK Safety Approved AC adapter of DC 12V, minimum 500mA.
This product is designed for a maximum ambient temperature of 40 degrees C.
ALL COUNTRIES
Codes.
: This product meets the following standards.
U.S. Federal Communications Commission
: In a domestic environment this product may cause radio interference in
: This product requires shielded cables to comply with emission and
Class 1 Laser product. Do not stare into the Laser beam.
: DO NOT WORK on equipment or CABLES during periods of
: Install product in accordance with local and National Electrical
Industry Canada
EN55022 Class A
EN50082-1 1997
EN60950, UL1950, CSA 950 EN60825
28
Normen
: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen.
1 Hochfrequenzstörung
2Warnung
3 Störsicherheit
4Achtung
5 Elektrische Sicherheit
6Laser
7Warnung
8Warnung
9
10 GEFAHR DURCH BLITZSCHLAG
11
12
13 BETRIEBSTEMPERATUR
14 ALLE LÄNDER
hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen.
Richtlinien für Emission und Interferenzschutz entsprochen wird. Falls das Produkt mit nicht abgeschirmten Kabeln verwendet wird, können weitergehende Maßnahmen für die Korrektur von Interferenzproblemen auf Kosten des Benutzers notwendig werden.
Das ist ein “LED Produkt der Klasse 1”
SICHERHEIT
GEFAHR
ausführen ENTLÜFTUNGSÖFFNUNGEN NICHT VERSPERREN Der Buchse darf nur aus dem Adapter Strom zugeführt werden.
EUROPE - EU
Gebrauchen Sie einen von TÜV zugelassenen Wechselstromadapter für Gleichstrom 12 V, 500 mA.
Dieses Produkt wurde für den Betrieb in einer Umgebungstemperatur von nicht mehr als 40° C entworfen.
Vorschriften entsprechen.
: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen
: Für dieses Produkt sind abgeschirmte Kabel erforderlich, damit den
Laserprodukt der Klasse 1. Nicht direkt in den Strahl blicken.
: Keine Arbeiten am Gerät oder an den Kabeln während eines Gewitters
: Installation muß örtlichen und nationalen elektrischen
AT-FS200 Series Installation Guide
EN55022 Klasse A
EN50082-1 1997
EN60950, UL1950, CSA 950 EN60825
Standarder
1 Radiofrekvens
2 Advarsel
3 Immunitet
4 Advarsel
5 Elektrisk sikkerhed
6Laser
7 Advarsel
8 Advarsel
9
forstyrrelsesemission
Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger.
bestemmelserne vedrørende udstråling og støjimmunitet. Hvis det bruges med uafskærmede kabler, kan det blive påkrævet af brugeren at korrigere interferensproblemer for egen regning.
Dette er et “PRODUKT UNDER KLASSE 1 LED”
: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse.
: Dette produkt skal bruges med afskærmede kabler for at overholde
Laserprodukt av klasse 1.
Stirr ikke på strålen.
: Dette produkt tilfredsstiller de følgende standarder.
EN55022 Klasse A
EN50082-1 1997
. EN60950, UL1950, CSA 950
EN60825
29
Electrical Safety and Installation Requirements
SIKKERHED
10 FARE UNDER UVEJR
11
12
13 BETJENINGSTEMPERATUR
14 ALLE LANDE
1 RFI Emissie
2 Waarschuwing
3 Immuniteit
4 Waarschuwing
5 Electrische Veiligheid
6Laser
7 Waarshuwing
8 Waarchuwing
9
10 GEVAAR VOOR BLIKSEMINSLAG
11
12
13 BEDRIJFSTEMPERATUUR
14 ALLE LANDEN
FARE
: UNDLAD at arbejde på udstyr eller KABLER i perioder med
LYNAKTIVITET. VENTILATIONSÅBNINGERNE MÅ IKKE BLOKERES Strømforsyningen til apparatet må udelukkende tages fra
tilpasningstransformatoren.
EUROPE - EU
Brug kun TÜV godkendt vekselstrømstransformator på 12 V jævnstrøm, 500 mA.
Dette apparat er konstrueret til en omgivende temperatur på maksimum 40 grader C.
national lovgivning for elektriske installationer.
Eisen
geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen.
apparaat te zijn voorzien van afgeschermde kabels. Als het met niet-afgeschermde kabels wordt gebruikt, kan het zijn dat de gebruiker maatregelen moet treffen om interferentieproblemen voor eigen rekening op te lossen.
Dit is een “KLASSE 1 LED-PRODUKT”
VEILIGHEID
GEVAAR
VENTILATIEGATEN NIET BLOKKEREN Stroom mag alleen via de adapter naar het apparaat toegevoerd worden.
EUROPE - EU
Gebruik een door TÜV gekeurde wisselstroomadapter van 12 Volt gelijkstroom, 500 milliampères.
De omgevingstemperatuur voor dit produkt mag niet meer bedragen dan 40 graden Celsius.
elektrische voorschriften.
: Installation af produktet skal ske i overensstemmelse med lokal og
: Dit product voldoet aan de volgende eisen.
: Binnenshuis kan dit product radiostoring veroorzaken, in welk
: Om te voldoen aan de emissie- en immuniteitsnormen dient dit
Klasse-1 laser produkt.
Neit in de straal staren.
: NIET aan toestellen of KABELS WERKEN bij BLIKSEM.
: het toestel installeren overeenkomstig de lokale en nationale
EN55022 Klasse A
EN50082-1 1997
EN60950, UL1950, CSA 950 EN60825
30
Normes
: ce produit est conforme aux normes de suivantes.
1 Emission d'interférences
2Mise En Garde
3 Immunité
4 Avertissement
5 Sécurité électrique
6Laser
7 Attention
8 Attention
9
10 DANGER DE FOUDRE
11
12
13 TEMPÉRATURE DE FONCTIONNEMENT
14 POUR TOUS PAYS
radioélectriques
interférences radioélectriques. Auquel cas, l'utilisateur devra prendre les mesures adéquates.
les normes d’émission et d’immunité. Si l’utilisateur choisit d’utiliser des câbles non blindés, il sera peut-être contraint de prendre les mesures nécessaires pour corriger les problèmes d’interférences, ainsi que d’assumer le coût correspondant.
Ce mat‚riel est un “PRODUIT A DIODE LECTROLUMINESCENTE DE CLASSE 1”
SÉCURITÉ
DANGER
NE PAS BLOQUER LES FENTES D'AÉRATION L'alimentation du concentrateur doit être uniquement fournie par l'adaptateur.
EUROPE - EU
Utiliser un adaptateur secteur conforme TÜV de 12 V, 500 mA en courant continu.
Ce matériel est capable de tolérer une température ambiante maximum de 40 degrés Celsius.
nationales et locales.
: dans un environnement domestique, ce produit peut provoquer des
: Il faut utiliser des câbles blindés pour ce produit afin de respecter
Producit laser di classe 1. Ne pas fixer le faisceau des yeux.
: NE PAS MANIER le matériel ou les CÂBLES lors d'activité orageuse.
: Installer le matériel conformément aux normes électriques
AT-FS200 Series Installation Guide
EN55022 Classe
EN50082-1 1997
EN60950, UL1950, CSA 950 EN60825
A
Standardit
1 Radioaaltojen häirintä
2Varoitus
3 Kestävyys
4Varoitus
5 Sähköturvallisuus
6Laser
7Varoitus
8Variotus
9
10 SALAMANISKUVAARA
11
tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin.
häiriönsietostandardien mukaisesti. Jos tuotetta käytetään ilman suojattuja kaapeleita, käyttäjä voi joutua korjaamaan häirinnän aiheuttaman ongelman omalla kustannuksellaan.
Tämä on “ENSIMMÄISEN LUOKAN VALODIODITUOTE”
TURVALLISUUS
ENGENVAARA
SALAMOINNIN AIKANA. ÄLÄ TUKI ILMAREIKIÄ
: Tämä tuote on seuraavien standardien mukainen.
: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä
: Tämä tuote vaatii suojattuja kaapeleita toimiakseen emissio- ja
Luokan 1 Lasertuote. Älä katso säteeseen.
EN55022 Luokka A
EN50082-1 1997
EN60950, UL1950, CSA 950 EN60825
: ÄLÄ TYÖSKENTELE laitteiden tai KAAPELEIDEN KANSSA
31
Electrical Safety and Installation Requirements
12
13 KÄYTTÖLÄMPÖTILA
14 KAIKKI MAAT
Tähtipisteeseen (hub) syötettävän virran pitää tulla ainoastaan sovittimesta.
EUROPE - EU
Käytä TÜV-lisenssillä valmistettua verkkosovitinta, jonka tasajännitteen nimellisarvot ovat DC 12 V, 500 mA (milliampeeria).
Tämä tuote on suunniteltu ympäröivän ilman maksimilämpötilalle 40° C.
sähköturvallisuusmääräysten mukaisesti.
: Asenna tuote paikallisten ja kansallisten
Standard
1 Emissione RFI (interferenza di
2 Avvertenza
3 Immunità
4 Avvertenza
5 Sicurezza elettrica
6Laser
7 Avvertenza
8 Avertenza
9
10 PERICOLO DI FULMINI
11
12
13 TEMPERATURA DI FUNZIONAMENTO
14 TUTTI I PAESI
radiofrequenza)
interferenza. In questo caso potrebbe richiedersi all'utente di prendere gli adeguati provvedimenti.
norme sulle emissioni e sull’immunità. In caso di uso senza cavi schermati, l’utente può dover adottare a proprie spese misure correttive contro le interferenze.
Questo è un “PRODOTTO CON LED DI CLASSE 1” NORME DI SICUREZZA
PERICOLO
PRECIPITAZIONI TEMPORALESCHE. NON OSTRUIRE LE PRESE D'ARIA Questo dispositivo deve essere alimentato solo mediante l’adattatore.
EUROPE - EU
Utilizzare l’adattatore per c.a. da 12 V c.c. e 500 mA conforme alla normativa TÜV.
Questo prodotto è concepito per una temperatura ambientale massima di 40 gradi centigradi.
elettriche nazionali.
: Questo prodotto è conforme ai seguenti standard.
: in ambiente domestico questo prodotto potrebbe causare radio
: questo prodotto, se utilizzato con cavi schermati, è conforme alle
Prodotto laser di Classe 1.
Non fissare il raggio con gli occhi.
: NON LAVORARE sul dispositivo o sui CAVI durante
: installare il prodotto in conformità delle vigenti normative
EN55022 Classe
EN50082-1 1997
EN60950, UL1950, CSA 950 EN60825
A
32
AT-FS200 Series Installation Guide
Sikkerhetsnormer
1 RFI stråling
2 Advarsel
3 Immunitet
4 Advarsel
5 Elektrisk sikkerhet
6Laser
7ADVARSEL
8ADVARSAL
9
10 FARE FOR LYNNEDSLAG
11
12
13 DRIFTSTEMPERATUR
14 ALLE LAND
1 Emissão De Interferência De
2 Aviso
3Imunidade
4 Advertência
5 Segurança Eléctrica
6Laser
7 Aviso
8 Aviso
9
10 PERIGO DE CHOQUE CAUSADO POR RAIO
11
12
radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler.
emisjons- og fritakelsesstandarder. Dersom produktet brukes med uvernede kabler, må brukeren muligens rette forstyrrelsesproblemene for egen regning.
Dette er et “KLASSE 1 LED PRODUKT”
SIKKERHET
FARE
BLOKKER IKKE LUFTVENTILENE All strømtilførsel må komme fra adapteren.
EUROPE - EU
Benytt TÜV-godkjent AC-adapter på 12V DC, 500mA (millismpere)
Dette produktet er konstruert for bruk i maksimum romtemperatur på 40 grader celsius.
elektriske koder.
Padrões
Radiofrequência
radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas.
cumprimento dos standards de limites de emissão e imunidade. Se o produto for utilizado com cabos não blindados, o utilizador poderá necessitar de tomar medidas para correcção de problemas de interferência, por sua própria conta.
Este é um “PRODUTO CLASSE 1 LED”
SEGURANÇA
PERIGO
suscetíveis a QUEDAS DE RAIO. NÃO BLOQUEIE AS ABERTURAS DE VENTILAÇÃO Use somente o adaptador fornecido para alimentação elétrica do hub.
: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake
: Dette produktet må brukes med vernede kabler for å tilfredsstille
: ARBEID IKKE på utstyr eller KABLER i TORDENVÆR.
: Este produto atende aos seguintes padrões.
: Num ambiente doméstico este produto pode causar interferência na
Produto laser de classe 1. Não olhe fixamente para o raio.
: NÃO TRABALHE no equipamento ou nos CABOS durante períodos
: Dette produktet tilfredsstiller følgende sikkerhetsnormer.
Laserprodukt av klasse 1. Stirr ikke på strålen.
: Produktet må installeres i samsvar med de lokale og nasjonale
: Este produto requer a utilização de cabos blindados para
EN55022 Klasse A
EN50082-1 1997
EN60950, UL1950, CSA 950 EN60825
EN55022 Classe
EN50082-1 1997
TUV-EN60950, UL1950, CSA 950 EN60825
A
33
Electrical Safety and Installation Requirements
EUROPE - EU
Use um adaptador de corrente alternada com saída DC de 12V e 500mA em conformidade com as especificações da TÜV.
13 TEMPERATURA DE FUNCIONAMENTO
14 TODOS OS PAÍSES
Este produto foi projetado para uma temperatura ambiente máxima de 40 graus centígrados.
para instalações elétricas.
: Instale o produto de acordo com as normas nacionais e locais
Estándares
1 Emisión RFI
2 Advertencia
3 Inmunidad
4 Advertencia
5 Seguridad eléctrica
6Laser
7 ¡ADVERTENCIA!
8 ¡ADVERTENCIA!
9
10 PELIGRO DE RAYOS
11
12
13 TEMPERATURA REQUERIDA PARA LA OPERACIÓN
14 PARA TODOS LOS PAÍSES
radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto.
emisión e inmunidad. Si se utiliza con cables sin protección, el usuario tendrá que correr con los gastos por las medidas a tomar en caso de problemas de interferencias.
Este es un “PRODUCTO DE DIODO LUMINISCENTE (LED) CLASE 1”
SEGURIDAD
ELIGRO
equipos o en LOS CABLES durante TORMENTAS ELECTRICAS. NO BLOQUEE LAS ABERTURAS PARA VENTILACION La energía para el dispositivo central o "hub" debe provenir únicamente del
adaptador.
EUROPE - EU
Utilizar un adaptador de corriente alterna autorizado TÜV de 12 voltios de corriente continua y 500 miliamperios.
Este producto está diseñado para una temperatura ambiental máxima de 40 grados C.
Eléctricos locales y nacionales.
: Este producto cumple con los siguientes estándares.
EN55022 Clase
: en un entorno doméstico, este producto puede causar
EN50082-1 1997
: Este producto exige cables protectores para ajustarse a las normas de
TUV-EN60950, UL1950, CSA 950 EN60825
Producto láser Clase 1.
No mirat fijamente el haz.
: NO REALICE NINGUN TIPO DE TRABAJO O CONEXION en los
: Monte el producto de acuerdo con los Códigos
A
34
AT-FS200 Series Installation Guide
Standarder
1 Radiostörning
2 Varning
3 Immunitet
4 Varning
5Elsäkerhet
6Laser
7VARNING!
8VARNING!
9
10 FARA FÖR BLIXTNEDSLAG
11
12
13 DRIFTSTEMPERATUR
14 ALLA LÄNDER
tvinga användaren till att vidtaga erforderliga åtgärder.
för emission och immunitet. Om den används med oskärmade kablar kan användaren vara tvungen att vidta åtgärder på egen bekostnad för att åtgärda störningsproblemet.
Detta är en “KLASS 1 LYSDIODPRODUKT”
SÄKERHET
FARA
BLOCKERA INTE LUFTVENTILERN Endast anslutningsenheten får vara kraftkälla till centralen.
EUROPE - EU
Använd en växelströmsanslutningsenhet licensierad av TÜV. Likström 12V, 500mA.
Denna produkt är konstruerad för rumstemperatur ej överstigande 40 grader Celsius.
bestämmelser för elektrisk utrustning.
: Denna produkt uppfyller följande standarder.
: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan
! Denna produkt kräver skärmade kablar för att uppfylla standardkraven
Laserprodukt av klass 1. Laserstrålning när enheten är öppen.
: ARBETA EJ på utrustningen eller kablarna vid ÅSKVÄDER.
: Installera produkten i enlighet med lokala och statliga
EN55022 Klass A
EN50082-1 1997
TUV-EN60950, UL1950, CSA 950 EN60825
35

Appendix C

Technical Support Fax Order

Name __________________________________________________________________
Company _______________________________________________________________
Address ________________________________________________________________
City ________________________ State/Province _______________________________
Zip/Postal Code ____________________ Country _______________________________
Phone _______________________________ Fax_______________________________

Incident Summary

Model number of Allied Telesyn product I am using _______________________________
Network software products I am using ________________________________________
______________________________________________________________________
Brief summary of problem __________________________________________________
______________________________________________________________________
Conditions (List the steps that led up to the problem.) _____________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
Detailed description (Use separate sheet, if necessary)
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
When completed, fax this sheet to the appropriate Allied Telesyn office. Fax numbers can be found on page viii.
37

Appendix D

AT-FS201, AT-FS202 and AT-FS203 Series Installation Guide Feedback

Please tell us what additional information you would like to see discussed in the guide. If there are topics you would like information on that were not covered in the guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of the guide.
I found the following the most valuable __________________________________
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
I would like the following more developed ________________________________
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
I would find the guide more useful if _____________________________________
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
Please fax or mail your feedback. Fax to 1-408-736-0100. Or mail to:
Allied Telesyn International, Corp.
c/o Technical Communications 960 Stewart Drive, Suite B Sunnyvale, CA 94086 USA
PN 613-10761-00 Rev B
39
Loading...