Allied Telesis AT-A47 User Manual

AT-A45/xx Series, AT-A46, and AT-A47
Expansion Modules
Installation Guide
Allied Telesis, Inc.
www.alliedtelesis.com
Overview
These expansion modules provide optional uplink ports for the AT-8000 Series Fast Ethernet Switches. They are designed for the two expansion slots on the front of the switches. The expansion modules, which can be installed in any combination and without having to power OFF the switch, offer flexibility in building or expanding your network. A maximum of two expansion modules can be installed in a switch.
AT-A45/MT
ACTIVITY
LINK
100BASE-FX/MT
Note
FULL DUP
HALF DUP
COL
Expansion Modules Available
The following expansion modules are available for your AT-8000 Series Fast Ethernet Switch.
Expansion Module
AT-A45/MT 100Base-FX MT-RJ 50/125 or 62.5/
AT-A45/SC 100Base-FX SC 50/125 or 62.5/
AT-A45/SC­SM15
AT-A46 10/100/
AT-A47 1000Base-X Varies by
1. The default configuration setting for the port on this module is Auto-MDI when operating at 10 or 100 Mbps. The port uses two pairs of twisted pair cable when operating at 10 or 100 Mbps and four pairs when operating at 1000 Mbps.
2. Refer to the GBIC Module Installation Guide or contact your Allied Telesis sales representative for additional information on available GBIC modules.
Port Type
100Base-FX SC 9/125 micron
1000Base-
1
T
Connector Type
RJ-45 10Base-T:
GBIC
2
module
Cable Type
125 micron multimode fiber
125 micron multimode fiber
single-mode fiber
Category 3 or better 100/ 1000Base-T: Category 5 or better
Varies by GBIC module
Maximum Cable Length
Half-duplex: 412 m (1,360 ft) Full-duplex: 2 km (6,600 ft)
Half-duplex: 412 m (1,360 ft) Full-duplex: 2 km (6,600 ft)
15 km (9.3 mi)
100 m (328 ft)
Varies by GBIC
2
module
2
Note
The GBIC module for the AT-A47 expansion module is sold separately.
Related Documents
The Allied Telesis web site at www.alliedtelesis.com offers you an easy way to access the most recent documentation, software, and technical information for all of our products. For details on the features and functions of your Allied Telesis AT-8000 Series Fast Ethernet Switch, refer to the following manuals from our web site:
Package Contents
Make sure the following items are included in the shipping package. If any item is missing or damaged, contact your Allied Telesis sales representative for assistance.
One AT-Axx Series Expansion Module
Installation Guide
Warranty Card
Installing an Expansion Module
Caution
Before installing an expansion module, refer to the PDF document titled “Translated Safety Statements V2” (613-000990) located on the Allied Telesis website at www.alliedtelesis.com, for electrical safety and emission information.
This section describes how to install an optional expansion module. To install an expansion module, follow these steps:
1. Unpack the module from its shipping container and store the packaging material in a safe location.
Note
You must use the original shipping material if you need to return the module to Allied Telesis.
2. Check that the module package includes all the items listed in section Package Contents. If any item is missing or damaged, contact your Allied Telesis sales representative for assistance.
3. Select a switch where you will install the expansion module.
4. Face the front panel of the switch and locate the expansion slots (left side of switch).
5. To remove an expansion slot faceplate, using a Phillips screwdriver, carefully loosen the installation screws found on the left and right sides of the faceplate, as displayed below. An expansion module can be installed in either expansion slot.
Caution
Be sure to observe all standard electrostatic discharge (ESD) precautions, such as wearing an antistatic wrist strap, to avoid damaging the device. If removing an expansion module, store the module in an antistatic bag or immediately install it in another switch. An expansion module can be damaged by static electricity.
*613-000748 Rev B*
613-000748 Rev B 1
AT-8000 Series Fast Ethernet Switch Installation Guide
PN 613-50244-00
AT-S39 Management Software User’s Guide
PN 613-50245-00
2 3
25
1
3
2
5
46
26
6. Remove the faceplate from the slot.
Keep the faceplate in a safe area in case you need to install it in the slot again. The faceplate will keep any dust from getting into the switch and will maintain proper airflow if the slot remains empty.
7. Carefully slide the expansion module into the slot until the expansion module faceplate makes contact with the switch, as displayed below. Avoid touching the expansion module components.
25
AT-A46
10/100/1000BASE-T
10
LINK
1000
100
FULL D
UPLEX
ACTIVITY
1
3
26
5
2
4
6
8. Secure the expansion module to the switch by using a Phillips screwdriver to tighten the installation screws found on the expansion module faceplate.
AT-A46
25
10/100/1000BASE-T
10
LINK
1000
100
FULL DUPLEX
ACTIVITY
1
3
26
5
2
4
6
Note
Always use the installation screws to secure the expansion module to the switch. Leaving an expansion module partially seated may cause the system to halt and subsequently crash.
9. If you purchased an AT-A47 expansion module, slide the GBIC module into the slot on the expansion module until it snaps into place, as displayed below.
AT-A47
25
C L A
S
LA
S
S
1 E R
P
R
O
D
D
U
O
CT N O
T
STA I NTO
RE B E A
M
10
1000BASE-X
LINK
ACTIVITY
1
3
26
5
2
4
6
10. Connect the twisted pair or fiber optic data cable to the expansion module.
LEDs
The expansion modules have port LEDs which display link and activity status on the port. Refer to the table below for port LED information.
LED State Description
AT-A45/xx Series Expansion Modules
LINK Steady Green The port has established a valid link with the
end node.
Flashing Green The port is transmitting and/or receiving data.
DUPLEX Steady Green The port is operating in full-duplex.
Steady Amber The port is operating in half-duplex.
Flashing Amber Collisions are occurring on the port.
AT-A46 Expansion Module
LINK 10 Steady Green The port has established a valid
10 Mbps link with the end node.
LINK 100 Steady Green The port has established a valid
100 Mbps link with the end node.
Both LINK 10 and LINK 100
FULL DUPLEX
ACTIVITY Flashing Green The port is transmitting and/or receiving data.
AT-A47 Expansion Module
LINK Steady Green The port has established a valid 1000 Mbps
ACTIVITY Flashing Green The port is transmitting and/or receiving data.
Steady Green The port has established a valid
1000 Mbps link with the end node.
Steady Green The port is operating in full-duplex.
OFF The port is operating in half-duplex.
link with the end node.
Port Specifications
The table below provides port specifications for the AT-A45/MT and AT-A45/ SC expansion modules.
Pin Signal
Technical Specifications
Operating Temperature 0° C to 40° C (32° F to 104° F)
Storage Temperature -20° C to 80° C (-4° F to 176° F)
Operating Relative Humidity Up to 3,048 meters (10,000 feet)
Storage Relative Humidity 5% to 80% (non-condensing)
Electrical Safety and Emission Statement
Standards: This product meets the following standards when installed in compliant host equipment.
U.S. Federal Communications Commission
RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Emission FCC Class A, EN55022 Class A, VCCI Class A
WARNING: In a domestic environment this product may cause radio interference in which
Immunity EN55024
Electrical Safety UL60950-1 (
case the user may be required to take adequate measures.
), EN60950-1 (TUV)
cULus
AT-A46
25
10/100/1000BASE-T
10
LINK
1000
100
FULL DUPLEX
ACTIVITY
1
3
2
5
46
26
11. Make sure the LINK LED on the front of the expansion module is steady green. (A 1000Base port may require from five to ten seconds to initially establish a link with an end node.)
4 5
Operating Wavelength 1310 nm
Transmitter Output Power 50/125 µm cabling
Min: -22.5 dBm avg. Max: -14 dBm avg.
62.5/125 µm cabling Min: -19 dBm avg. Max: -14 dBm avg.
Receiver Sensitivity Max: -14 dBm avg.
No part of this publication may be reproduced without prior written permission from Allied Telesis Inc.
Copyright © 2008 Allied Telesis, Inc. All rights reserved.
6
Loading...