Allied Telesis AT-A40-SC, AT-A35-SX, AT-A39-T, AT-A35-SX-SC User Manual

Datasheet | Expansion Modules
Rapier Series Uplink Modules
Gigabit & Fast Ethernet
AT-A35/SX
1 x Gigabit fiber uplink SC connector
AT-A35/LX
1 x long haul Gigabit fiber uplink SC connector
AT-A39/T
1 x auto-negotiating Gigabit copper uplink RJ-45 connector
AT-A40/SC
Fast Ethernet multimode fiber uplink, SC connector
AT-A40/MT
Fast Ethernet multimode fiber uplink, MT connector
AT-A41/SC
Fast Ethernet singlemode fiber uplink, SC connector
AT-A41/MT
Fast Ethernet singlemode fiber, MT connector
AT-A42/GBIC
Uplink module with 1 GBIC bay
Uplink Fle
Uplink modules pro interface options, including Gigabit copper, Fast Ether allows Rapier L3 switches to span a wide variety of netw Uplink modules can be changed or replaced to meet changing network requirements, reducing backup inventory costs.
xibility
vide a flexib
iber, and Gigabit fiber. This flexibility
net f
ork topologies and physical media.
le r
ange of
Model Compatibility
Rapier Rapier i Rapier G Rapier GF 8700XL AT-A35/SX Yes Yes Yes Yes Yes AT-A35/LX Yes Yes Yes Yes Yes AT-A39/T Yes
1
Yes Yes Yes Yes AT-A40/SC No Yes Yes Yes Yes AT-A40/MT No Yes Yes Yes Yes AT-A41/SC No Yes Yes Yes Yes AT-A41/MT No Yes Yes Yes Yes AT-A42/GBIC Yes Yes Yes Yes Yes
1. Does not offer auto-negotiation, operates at 1000T only.
Regulatory Standards
AT-A35/SX, AT-A35/LX & AT-A39T EMC EN55022 class A, FCC class A, and
VCCI class A Immunity EN55024 Safety Listing - UL, cUL, TUV
Standards - UL 60950, CAN/CSA-C22.2
NO. 60950-00, EN60950
AT-A40/SC, AT-A40/MT, AT-A41/SC, AT-A41/MT & AT-A42/GBIC EMC EN55022 class A, FCC class A, and
VCCI class
A Immunity EN55024 Safety Listing - UL, cUL, TUV
Standards - UL 60950, CAN/CSA-C22.2 NO. 60950-00, EN60950
Environmental Specifications
Operating Temp. 0°C to 40°C (32°F to 104°F) Storage Temp. -25°C to 70°C (-13°F to 158°F) Relative Humidity 5 to 95% non-condensing
Key Features
Gigabit fiber
Gigabit fiber long haul
Auto-negotiating Gigabit copper
Fast Ethernet fiber (singlemode fiber
& muti-mode fiber)
Flexible, hot-swappable GBIC
Interoperable with Rapier i, Rapier G6,
Rapier G6F & 8700XL switches
LED status indicators
Compact size
Gigabit Interface Converter (GBIC) Modules
T-G8SX
A
500m SX GBIC, based on 50 Micron fiber 220m SX GBIC, based on 62.5 Micron fiber
T-G8LX10
A
10km LX GBIC
AT-G8LX25
, based on 9 Micron fiber
25km LX GBIC, based on 9 Micron fiber
AT-G8LX40
40km LX GBIC, based on 9 Micron fiber
T-G8LX70
A
70km LX GBIC
based on 9 Micron fiber
,
Allied Telesis www.alliedtelesis.com
Rapier Series Uplink Modules | Gigabit & Fast Ethernet
Competitive Matrix
Model Port Connector Cable Type
AT-A35/SX 1000SX SC 50/125 micron
1
Max Cable Length
550 m (1,804ft)
2
multimode fiber
62.5/125 micron
275 m (902ft)
3
multimode fiber
AT-A35/LX 1000LX SC 9/125 micron
singlemode fiber
3km (1.8mi) increasing to 10km (6mi) if linking two 1000LX models
50/125 or 62.5/125
550m (1804ft)
2
micron multimode fiber
AT-A39/T 10/100/1000T
AT-A40/SC 100FX
(multimode fiber, 1300nM)
T-A40/MT
A
100FX (multimode fiber, 1300nM)
AT-A41/SC 100FX
(multimode fiber, 1300nM)
AT-A41/MT N100FX
(singlemode fiber, 1300nM)
4
RJ-45 CAT5
CAT5E
SC 50/125 or 62.5/125
100 to 150m (328 to 492ft) 200m (656ft)
2km
micron multimode fiber
-RJ
MT
50/125 or 62.5/125
2km
micron multimode fiber
SC 50/125 or 62.5/125
2km
micron multimode fiber
MT-RJ 9/125 micron
15km
singlemode fiber
AT-A42/GBIC 1000X Varies per GBIC Refer to GBIC documentation Refer to GBIC documentation
1. Refer to the IEEE 802.3 standards for further cable information.
2. Assumes a fiber optic cable rating of 500 Mhz/Km. (Maximum cable length is 500m at a cable rating of 400 Mhz/Km.)
3. Assumes a fiber optic cable rating of 200 Mhz/Km. (Maximum cable length is 220m at a cable rating of160 Mhz/Km.)
4. Early versions of the AT-A39/T operate at 1000Mbps only. 10/100/1000Mbps operation is available only if the AT-A39/T Uplink Module is installed in a Rapier G6, Rapier G6F or Rapier i model, otherwise operation is fixed at 1000Mbps.
Ordering Information
AT-A35/SX
1 x 1000SX/SC uplink with SC connector
AT-A35/LX
1 x 1000LX/SC uplink with SC connector
AT-A39/T
1 x 1000T uplink with RJ-45 connector
AT-A40/SC
100FX multimode fiber uplink with SC connector
AT-A40/MT
100FX multimode fiber uplink with MT connector
AT-A41/SC
100FX singlemode fiber uplink with SC connector
AT-A41/MT
100FX singlemode fiber uplink with MT connector
AT-A42/GBIC
Uplink module with 1 GBIC bay (Uses Allied Telesis standards-based GBIC modules. GBIC ordered separately)
(ATR) Model
AT-A35/SX multimode fiber 850 -4 to -9.5 -12.5 @ 62.5uM,
singlemode/ multimode
Wavelength Tx power (dBm) Sensitivity (dBm) Saturation (dBm)
0
-13.5 @ 50uM
T-A35/LX
A
AT-A40/SC multimode fiber 1310 -14 to -19@62.5uM,
singlemode fiber multimode fiber multimode fiber
1310 -3 to -9.5@9uM,
-3 to -11.5@62.5uM,
-3 to -11.5@50uM
-20 -3
-34.5 -14
-14 to -22.5@50uM
AT-A40/MT multimode fiber 1310 -14 to -19@62.5uM,
-34.5 -14
-14 to -22.5@50uM
T-A41/SC
A
singlemode fiber 1310 -14 to -20 -31 -8
AT-A41/MT singlemode fiber 1310 -14 to -20 -31 -8
USA Headquarters | 19800 North Creek Parkway | Suite 200 | Bothell | WA 98011 | USA | T: +1 800 424 4284 | F: +1 425 481 3895 European Headquarters | Via Motta 24 | 6830 Chiasso | Switzerland | T: +41 91 69769.00 | F: +41 91 69769.11 Asia-Pacific Headquarters | 11 Tai Seng Link | Singapore | 534182 | T: +65 6383 3832 | F: +65 6383 3830
www.alliedtelesis.com
© 2006 Allied Telesis Inc.All r ights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the proper ty of their respective owners. 617-00458-00 Rev. G
Loading...