Allen & Heath Limited
Kernick Industrial Estate
Penryn, Cornwall,
TR10 9LU, UK
www.allen-heath.com
Overview
IP1 Te ch ni ca l Da ta sh e et
§ Wall or plinth mounted
§ EU & US versions available
§ Compatible with Decora and MK Elements
faceplates
§ Interface with dLive (DM or Surface) via TCP/IP
§ Dual function push & Turn rotary encoder
§ LCD Display
§ Programmable via Surface or Director software
§ Powered via PoE
IP 1 Technical Data Sheet Issue 2018 Allen & Heath Ltd

Dimensions - EU
Dimensions - US
\
IP1 Technical Datasheet Issue 2018 2 Allen & Heath Ltd

A&E Specifications
Operating Temperature Range
0°C to 35°C (32°F to 95°F)
802.3af (15.4W at source) and 802.3at (30W at source)
Width x Depth x Height x Weight
50 x 32 x 50 mm (2" x 1.3" x 2") x 70g (2.5 ounces)
45 x 25 x 106 mm (1.8” x 1” x 4.2”) x 100g (3.5 ounces)
131 x 170 x 90 mm (5.2" x 6,7" x 3.5") x 0,2kg (7 ounce)
131 x 170 x 90 mm (5.2" x 6.7" x 3.5") x 0,2kg (7 ounce)
The remote controller shall be of a fixed installation type with 1
rotary encoder and 1 LCD display.
The rotary encoder shall be dual function with the second
function being accessed via a push and turn action.
There shall be a fast Ethernet connection via an RJ45
connector. Connection of the controller shall be either direct to
the Mixrack/Surface via standard Cat5 data infrastructure.
Alternatively, it shall be capable of multiple parallel connections
using an Ethernet switch. Configuration and programming of
the controller shall be via the console touchscreen or remote
software installed on a PC or MAC.
Technical Specifications
The controller shall be powered by the Cat5 control cable via a
PoE enabled device. The controller shall be compatible with
both PoE standards 802.3af (15.4W at source) and 802.3at
(30W at source). The maximum power consumption of the
controller shall be 2.5W.
The remote controller shall be used wall/plinth mounted with
multiple options to suit varying pattress box standards. These
options shall include compatibility with Decora and Mk
Elements faceplates when integrating with varying architectural
finishes.
Recommended operating temperature for the controller shall
be 0 to 35 degrees Celsius.
The controller shall be the Allen & Heath IP1.