IP1 /US fitting note AP11269 Issue 2
This product must be installed by a professional installer
or qualified electrician.
The IP1 is part of the Allen & Heath IP series of remote controllers.
IP1 requires dLive firmware V1.60 or higher.
Mounting the Remote Controller
This model fits standard US single-gang electrical boxes (NEMA WD-6 standard) with a minimal depth of 25mm. It accepts Leviton Decora and compatible face plates. Refer to the instructions of the face plate and/or wall box for screw specification and mounting.
Connection and configuration
The IP1 provides a Fast Ethernet, PoE compliant network port for connection to the mixing system.
The maximum cable length is 100m. Use STP (shielded
twisted pair) CAT5 or higher cables.
The factory default network settings are as follows:
Unit Name IP1 DHCP Off IP Address 192.168.1.74 Subnet Mask 255.255.255.0 Gateway 192.168.1.254
When connecting multiple IP Remote Controllers to the same network, ensure each unit is set to a unique Name and IP Address beforehand.
NEMA single­gang wall box
Face plate
IP1
A jumper link on the main PCB board lets you reset the
network settings to factory default. To reset, short the link for 10s whilst applying power to the unit.
Refer to the IP1 Getting Started Guide and dLive
Firmware Reference Guide available for download at
www.allen-heath.com for more information on IP1
connections, network settings and programming.
Front panel
Technical specs
Network
Fast Ethernet 100Mbps
PoE
802.3af
Max power consumption
2.5W
Operating Temperature Range
0 deg C to 35 deg C (32 deg F to 95 deg F)
LCD Display
Colour display providing
information on the
selected channel or
output mix. It can also
display a Source or Scene
list when the rotary is
pressed if such function
is assigned to the IP1.
Rotary Encoder
Assignable dual function rotary control. Push and turn to control its second function (momentary e.g. Pan) or push to enter Source Select or Scene Select function.
Available functions include Input Level, Mix Level, DCA Level, Aux Send Level, FX Send Level, Matrix Send Level, Source Selector (Level + Source), Pan, Scene Select.
Read the Safety Instructions Sheet included with the product before operating.
A limited one year manufacturer’s warranty applies to this product, the conditions of which can be found at: www.allen-heath.com/legal
By using this Allen & Heath product and the software within it you agree to be bound by the terms of the relevant End User Licence Agreement (EULA), a copy of which can be found at: www.allen-heath.com/legal
Register your IP1 with Allen & Heath online at: http://www.allen-heath.com/support/register-product/
Check the Allen & Heath website for the latest documentation and software updates.
ALLEN&HEATH
Copyright © 2017 Allen & Heath. All rights reserved
Loading...