Laite on liitettävä suojamaado ituskoskettimilla varustettuun pist orasiaan
Apparatet må tilkoples jordet stikkontakt
Apparaten skall anslutas till jordat uttag
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
THIS APPARATUS MUST BE EARTHED.
CET APPAREIL DOIT ETRE MIS A LA TERRE
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan
Apparatet må tilkoples jordet stikkontakt
Apparaten skall anslu tas till jordat uttag
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
THIS APPARATUS MUST BE EARTHED.
CET APPAREIL DOIT ETRE MIS A LA TERRE
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
100 - 240V~
47-63Hz ~ 25W MAX
100 - 240V~
47-63Hz ~ 25W MAX
ATTENTION: REMPLACER PAR UN FUSIBLE STRICTEMENT IDENTIQUE EN VALEURS.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE
REPLACE FUSE WI TH SAME TYPE AND RATING.
FUSE: T500mA L
20mm
250V
ATTENTION: REMPLACER PAR UN FUSIBLE STRICTEMENT IDENTIQUE EN VALEURS.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE
REPLACE FUSE WITH SAME TYPE AND RATING.
FUSE: T500mA L
250V
20mm
next
next
OUT
DR-LINK
previous
AUDIO OUTOUT DR-LINK IN
DIGITAL EXPANDER
previous
IN
AUDIO IN
DIGITAL EXPANDER
EXPANDER INPUTS
ALLEN&HEATH
iDR D-in
S/N
EXPANDER OUTPUTS
ALLEN&HEATH
iDR D-out
S/N
powerlocklink
locklink power
4
AES IN
S/PDIF INS/PDIF INS/PDIF INS/PDIF IN
Made in the UK by ALLEN&HEATH LIMITED
4321
AES OUT
S/PDIF OUTS/PDIF OUTS/PDIF OUTS/PDIF OUT
Made in the UK by ALLEN&HEATH LIMITED
AES IN
DIGITAL INPUTS
AES OUTAES OUTAES OUT
DIGITAL OUTPUTS
23
AES IN
iDR D-in
DIGITAL AUDIO INPUT EXPANDER
iDR D-out
DIGITAL AUDIO OUTPUT EXPANDER
1
AES IN
iDR D-in and iDR D-out are add-on digital audio expander units for the Allen & Heath iDR-4 and iDR-8 audio mix
processors. They provide AES3 and SPDIF format digital audio inputs and outputs to add to the analogue audio
connections on the main unit. The iDR D-in has 8 inputs arranged as 4 pairs. Either the AES3 (XLR) or the SPDIF
(RCA phono) input may be selected for each pair. The iDR D-out has 8 outputs arranged as 4 pairs. These provide
AES3 and SPDIF outputs simultaneously available. Only one input and one output expander may be added to the iDR
system bringing it up to a maximum 16x16 audio matrix. This may be any combination of the analogue and digital
expanders available for the iDR system. These units do not have any processing built in. They simply convert the
AES3 and SPDIF formats to work with the 8 channel wide iDR digital bus which feeds the main unit via a CAT5 STP
cable. The processing and mixing is handled by the main iDR-4 or iDR-8 unit which features the full 16x16 DSP matrix.
The iDR System Manager software is used to select either the AES3 or the SPDIF connection for each expander input
pair. Both expander units have 8 front panel LEDs in addition to the 3 status indicators. These are 3-colour soft LEDs
which can be assigned as audio meters, mute indicators or patch related indicators. They are programmed in the
usual way using the iDR System Manager software. Control of the expanders is via the DR-Link port using a CAT5 STP
cable. This means that two CAT5 cables are required to interconnect an expander to the main unit. Maximum distance
between the units is 250 metres. Local mains power is required.
This product complies with the European Electromagnetic
Compatibility directives 89/336/EEC & 92/31/EEC and the
European Low Voltage Directives 73/23/EEC & 93/68/EEC.
NOTE: Do not remove the cover of the unit. There are no user serviceable
parts inside. Any changes or modifications to the equipment not approved by
Allen & Heath could void the compliance of the equipment and therefore the
users authority to operate it.
Whilst we believe the information in this guide to be reliable we do not assume
responsibility for inaccuracies. We also reserve the right to make changes in
the interest of further product development.
iDR D-in/out User Guide AP6636 1
N
N
U
The iDR D-in and iDR D-out expanders can be rack mounted or free standing. There are
no user controls on the front panel, only the status and assignable LEDs. Allow a minimum
of 75mm clearance behind the unit for the connectors and cables. Ensure adequate
ventilation to the side of and behind the unit.
The units are shipped with their rack ears fitted and feet removed ready to be mounted in a
standard 19” equipment rack. 1U rack space is required. For desk mount operation
remove the two rack ears using a Torx (star head) T10 screwdriver. Fit the four plastic feet
provided by pressing them into the underside.
48mm
1.9"
M3 Torx T10
Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan
Apparatet må tilkoples jordet stikkontakt
Apparaten skall anslutas till jordat uttag
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
THIS APPARATUS MUST BE EARTHED.
CET APPAREIL DOIT ETRE MIS A LA TERRE
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
100 - 240V~
47-63Hz ~ 25W MAX
44mm
iDR-in and iDR-out EXPANDERS
1.7"
1U
Remove 2x rack ears
Fit 4x feet
ATTENTION: REMPLACER PAR UN F
FOR CONTINUED PROTECTION AGAI
REPLACE FUSE WITH SAME TYPE A
FUSE: T500mA L
250V
20mm
483mm
443mm
19"
17.4"
307mm
12"
powerlock link
lock link power
232mm
9.1"
iDR-in
AUDIO INPUT EXPANDER
iDR-out
AUDIO OUTPUT EXPANDER
75mm
3"
Make sure you have read the Important Safety
Instructions provided. Also check that your local mains
supply is compatible with that printed on the rear panel of
the unit. Ensure that the correct mains lead with moulded
plug and IEC connector has been supplied. For your own
safety and optimum performance make sure the system is
correctly grounded.
To avoid any unexpected audible clicks or thumps
always turn connected power amplifiers down or off before
switching the iDR or any other signal equipment on or off.
Turning the expander on or offFirst make sure
powerlocklink
the unit is correctly plugged up and connected to the iDR-4(8).
This is described below. Turn the unit on by pressing the rear
panel power ON/OFF switch. The power LED lights up. The
link LED lights if the DR-Link connection is established with the
iDR-4(8). The lock LED lights once the link is established and
audio is correctly communicated with the iDR-4(8). The iDR
System Manager detects the presence of the expander.
If one or more of the LEDs do not light then check that the
cables are correctly fitted and the iDR-4(8) is functioning
normally.
Checking for expanders You can use the front
*8 Diagnostics
Audio Exp:In/Out
2 IDR D-in/out User Guide AP6636
panel iDR-4(8) Setup menus to check if any expanders are
connected and recognised. This is useful when the expanders
are located far away from the main unit. With the face plate
removed access menu *8 Diagnostics and scroll to Audio Exp.
Refer to the iDR-4 user guide AP5230 or iDR-8 user guide
AP4530 for further details.
CONNECTING THE INPUT EXPANDER
iDR
iDR D-in
CONNECTING THE OUTPUT EXPANDER
iDR
iDR D-out
CONNECTING BOTH EXPANDERS
iDR
iDR D-in
iDR D-out
DR-LINK
DR-LINK
DR-LINK
DR-LINK
87654321
IN
IN
OUT
87654321
OUT
AUDIO
12 LR11 LR10 LR9 LRIN
OUT
87654321
IN
IN
OUT
87654321
OUT
AUDIO
OUT
12 LR11 LR10 LR9 LR
IN
87654321
IN
IN
OUT
87654321
OUT
AUDIO
12 LR11 LR10 LR9 LRIN
OUT
AUDIO
OUT 12 LR11 LR10 LR9 LR
IN
Connecting to the iDR-4(8)
You can connect
either or both expanders according to the requirements of your
application. Note that the iDR-in and iDR-out analogue
expanders are also available. The iDR D-in AUDIO OUT
connects to the iDR-4(8) AUDIO IN. The iDR D-out AUDIO IN
connects to the iDR-4(8) AUDIO OUT. Ensure that the
expander DR-Link IN connects to DR-Link on the iDR-4(8) it is
associated with. If both expanders are used with the same
iDR-4(8) then daisy chain from DR-Link OUT of one to DR-Link
IN on the other. DR-Link can also be daisy chained from or to
iDR-switch units if you are using them as well.
next
OUT
DR-LINK
previous
AUDIO OUT
IN
DIGITAL EXPANDER
Fully expanded iDR-4(8) The diagram below shows
the iDR-8 with both the input and output digital expanders
fitted. Note the connection of DR-Link which is daisy chained
from one unit to the next. If an iDR-switch unit is also fitted
then daisy chain DR-Link from the last expander to the switch
unit. Make sure you plug into the correct DR-Link socket.
Use CAT5 STP cable. A pair of standard 2 metre cables is
provided with each expander. Maximum cable length is 250
metres. This means that the expander units can be used for
remote audio over CAT5 cable.
INPUTOUTPUT
1
2
3
4
5
6
7
iDR D-iniDR D-out
AES
SPDIF
Select
AES
SPDIF
Select
AES
SPDIF
Select
AES
SPDIF
Select
OUT IN DR-LinkOUT INDR-Link
250 metre max250 metre max
AUDIO OUT
AUDIO IN
CAT5
SIG GEN
8
9
10
11
12
13
14
15
16
iDR-8
ACTIVE MONITOR
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
AUDIO OUTAUDIO IN
CAT5
AES
SPDIF
AES
SPDIF
AES
SPDIF
AES
SPDIF
DR-Link
CAT5
CAT5
iDR D-in/out User Guide AP6636 3
iDR D-in
iDR
iDR
iDR D-out
DR-LINK
DR-LINK
AUDIO
DR-LINK
INOUT
OUT
OUT
IN
OUT
IN
IN
INOUT
DR-LINK
12 LR11 LR10 LR9 LRIN
87654321
IN
87654321
OUT
AUDIO
87654321
IN
87654321
OUT
OUT 12 LR11 LR10 LR9 LR
Expanded multiple iDR system This diagram
shows an iDR system with two iDR-8 units and both expanders
fitted. A system could also be created with iDR-4 units or a mix
of iDR4 and iDR-8 units. Note that the digital or analogue
expanders may be used, but only one input and one output
expander may be added per system. DR-Link is only required
to connect to the expanders, not between the main units.
Make sure you connect DR-Link to the iDR associated with
each expander. Make sure you plug into the correct DR-Link
socket. In this case do not daisy chain DR-Link from one
expander to the other.
Use CAT5 STP cable. Maximum cable length is 250 metres.
Maximum audio matrix is 16x16. The audio link cable carries 8
channels. This can provide a distributed system with 8
common channels and 8 local channels at each unit.
Working with iDR System Manager The online
Editor recognises any expanders connected. If you are
working offline then a simulation of the expanders is provided.
This is the same for either the analogue or digital output
expander. If you want to simulate a digital input expander then
select this from the File / Preferences / Expander Options
menu. When choosing a digital input as a channel Source you
can select either the AES3 or the SPDIF connection. The
digital input selection is also available as a parameter which
can be stored and recalled in the presets.
For further information refer to the Allen & Heath web site or
contact Technical Support in your area.
www.allen-heath.com
Inputs x8
4x pairs AES3 and SPDIF
Sample rate conversion
Select using iDR System Manager
Soft LEDs
Assignable by the installer
iDR D-in 8x front panel indicators
iDR D-out 8x front panel indicators
3-colour – green, yellow, red, off
Outputs x8
4 pairs AES3 and SPDIF
Both formats available simultaneously
Expander Input / Output Port
Proprietary 8 channel digital audio
Connects to iDR-4 or iDR-8 main unit
CAT5 STP cable up to 250 metres (825 feet)
DR-Link Port
Serial control of iDR expander units
Proprietary Allen & Heath control protocol
Function 3-colour signal meters
Mute on/off (red)
Static patch related (one of 3 colours)
Power Supply
Universal mains input switched mode design
IEC 3pin socket
Country dependent mains lead supplied
Rear panel power on/off switch
AC mains input 100-240V AC 50/60Hz
25VA max
Fuse T500mAL 20mm
IN and OUT ports provided to allow daisy
chaining through multiple units
CAT5 STP cable up to 250 metres (825 feet)
Status LEDs
Power –mains power on
Link – DR-Link control communication
Lock –audio communication
Mechanical
1U rack 483 x 232 x 44mm
19” x 9.1” x 1.7”
Desk 443 x 232 x 48mm
17.4” x 9.1” 1.9”
Weight 3.5kg, 7.7lbs
4 IDR D-in/out User Guide AP6636