ALLEN&HEATH GL2400 SYS-LINK AP6050 issue 2
Applications Note
SYS-LINK explained
SYS-LINK (system link) is the Allen & Heath connection standard for linking two consoles together to
expand the number of input channels feeding the mixes. One becomes the ‘slave’ to the other ‘master’
console. All the slave console mix busses including main LR, groups and auxes connect directly to the
master console mix busses without using up valuable input channels. The PFL/AFL system is also
linked so that all channels can be monitored using the master console headphones and meters. The
slave console master section is not used as its signals are taken before the mix inserts and output
faders. Both consoles must have the SYS-LINK option fitted. A single multiway cable is all that is
required to link the GL2400 to another Allen & Heath console fitted with SYS-LINK.
1 INPUTS 16 17 24
SLAVE
37way cable (not included with kit)
A&H part No. AH4131
25 INPUTS 40 41 48
MASTER
OUTPUTS
SYS-LINK versions 1 and 2
The GL2400 uses the more recent SYS-LINK Version 2 standard. This benefits from balanced
interconnections which allow longer cable length with less chance of noise and interference pickup
than the earlier, unbalanced SYS-LINK Version 1. Both versions operate at -2dBu line level. V1 uses
the 25way D-type connector. V2 uses the 37way D-type connector. Two consoles fitted with SYS-LINK
V2 can be linked using a 36-core shielded cable wired one to one to two 37way male D-type
connectors. It is also possible to connect between SYS-LINK V2 and V1. This requires a 37way to
25way adapter cable wired to unbalance the connections. Wiring details are provided later in this
document. The interconnecting cable is not included in the kit and should be sourced elsewhere or
ordered separately from Allen & Heath.
GL2400 SYS-LINK V2 input and output option
Option kit GL2400-SLV2 is available from
Allen & Heath. This can be installed in the
GL2400 console to provide both SYS-LINK
V2 input and output. The console may be
used as either a ‘slave’ or a ‘master’. For
information on fitting the option refer to
document AP6049.
GL2400 SYS-LINK Applications Note AP6050 1
Linking consoles
SYS-LINK V2 to V2 connection
Plug the ‘slave’ console SYS-LINK V2 output
into the ‘master’ console SYS-LINK V2 input.
Make sure the connectors are fully plugged
in and their securing screws tightened.
If one console has more than one SYS-LINK
connector, plug into the socket marked ‘A’.
37way male to male D-type cable wired
one to one. 36-core shielded cable with
screen soldered to pin 19.
A suitable cable is available from Allen &
Heath – part number AH4131
Recommended cable length 2.9 metres,
maximum length less than 5 metres.
SYS-LINK V2 to V1 connection
37way male to 25way male D-type cable wired as shown below. Minimum 18-core shielded cable with
screen soldered to chassis at both ends. Maximum cable length 2.9 metres.
A suitable cable is available from Allen & Heath – part number AH6552
(Pin allocations shown are for ‘A’ connectors – adapter cable
is also suitable for ‘B’ connectors)
25way 37way 25way 37way
Pin 1 > 1 Pin 18 > 10
Pin 2 > 2 Pin 19 > 12
Pin 3 > 5 Pin 20 > 13
Pin 4 > 7 Pin 21 > 14
Pin 5 > 9 Pin 22 > 15
Pin 6 > 11 Pin 23 > 16
Pin 14 > 3 Pin 24 > 17
Pin 16 > 6 Pin 25 > 18
Pin 17 > 8
Pin 13 > 20 to 37 (linked 0V) (pin 13
also connected to 25way chassis)
37way Pin 19 = chassis
25way Pins 7 to 12,15 not connected
37way Pin 4 not connected
Custom applications
To connect other audio equipment using the SYS-LINK connectors always ensure unused audio inputs
are linked to 0V ground at the input connector. This is to prevent interference pickup on unterminated
high impedance inputs. Do not link unused outputs to ground. Connect line level signals of -2dBu.
Use balanced connections where possible. For unbalanced signals link signal ‘-‘ to 0V. To activate
PFL/AFL link PFL DC to 0V through a 15k ohm resistor (37 way Pins 3 to 1).
If you require further information or advice please contact Allen & Heath Technical Support.
2 GL2400 SYS-LINK Applications Note AP6050