Allen & Heath DX164-W Datasheet

Page 1
Allen & Heath Limited Kernick Industrial Estate Penryn, Cornwall, TR10 9LU, UK
www.allen-heath.com
Overview
DX164-W Te ch n ic al Da tasheet
Designed for Wall Mount or Dip Trap installation
16 Mic Preamps on XLR
Phantom Power LED per Input
4 XLR Line Outs
DX A connection with locking Ethercon port
DX B locking Ethercon port for daisy chaining or
redundancy
DX164-W Technical Datasheet issue 2018 1 Allen & Heath Ltd
Page 2
87.00
210.00
210.00
120.84
Dimensions
A&E Specifications
The unit shall be a remote audio device for the Allen & Heath dLive and SQ mixing system. The remote audio unit shall provide 16 XLR inputs with individually configured Phantom Power and 4 XLR outputs. Phantom power LED indicators shall be provided per input socket on the remote audio rack.
Two Neutrik Ethercon DX link connectors shall be provided for transport of the digital audio and control signals. The unit shall be able to operate in ‘redundant’ or ‘cascade’ mode by means of a mechanical switch. In ‘redundant’ mode the unit shall provide full redundant connection to the Mixrack or Surface. In ‘cascade’ mode the unit shall allow series connection of two units.
The Ethernet protocol shall provide control to the remote preamp, and all mic preamps are scene recallable by the digital mixing system. Unit firmware shall automatically be updated or downgraded when connected to the digital mixing system.
The remote audio rack shall have a robust steel chassis and shall be designed to be placed in different mounting options including NEMA12x12” box, horizontally or vertically, flush or straight mount.
The remote audio rack shall have a built-in power supply accepting AC mains voltages of 100~240V, 50/60 Hz, 35W max via an earthed 3-pin IEC male connector or thru an optional screw terminal with Cable gland mounted on the rear chassis. Secondly there needs to be a 12V DC power connection which can be used as primary power supply or Redundant power supply.
Recommended operating temperature for the remote audio rack shall be 0 to 35 degrees Celsius.
The unit shall be the Allen & Heath DX164-W.
DX164-W Technical Datasheet issue 2018 2 Allen & Heath Ltd
Page 3
Mic/Line XLR Inputs
Balanced XLR, +48V phantom power
Mic/Line Preamp
Fully recallable
Input Sensitivity
-60 to +15dBu
Analogue Gain
+5 to +60dB, 1dB steps
Pad
-20dB Active PAD
Maximum Input Level
+30dBu (PAD in)
Input Impedance
>4kΩ (Pad out), >10kΩ (Pad in)
Mic EIN
-127dB with 150 source
Analogue XLR Outputs
Balanced, Relay protected
Output Impedance
<75Ω
Nominal Output
+4dBu = 0dB meter reading
Maximum Output Level
+22dBu
Residual Output Noise
-92dBu (muted, 20-20kHz)
-90dBu (muted, 20-40kHz)
Operating Temperature Range
0°C to 35°C (32°F to 95°F) Power
Mains Voltage Operating Range
100-240V AC, 50/60Hz
Mains Power Consumption
35W max
DC Input
12V DC, 3A max
Dimensions and Weight
Width x Depth x Height x Weight
DX164-W
210 x 87 x 210 mm x 3.2kg (8.25” x 3.5” x 8.25” x 7lbs)
System Specifications
DX164-W Technical Datasheet issue 2018 3 Allen & Heath Ltd
Loading...