Allegro A3195LU, A3195LLT, A3195EU, A3195ELT Datasheet

3195
PROTECTED, HIGH-TEMP., ACTIVE PULL-DOWN HALL-EFFECT LATCH
HALL-EFFECT LATCH WITH ACTIVE PULL-DOWN
X
LATCH
CC
V
1
32
3195
PROTECTED, HIGH-TEMPERATURE,
Data Sheet
27609.15*
SUPPLY
Pinning is shown viewed from branded side.
GROUND
Dwg. PH-013
OUTPUT
ABSOLUTE MAXIMUM RATINGS
Supply Voltage, VCC (100 ms) .......... 115 V*
(continuous)................................... 26 V
Reverse Battery Voltage,
V
(100 ms)............................ -100 V
RCC
(continuous)................................. -30 V
Magnetic Flux Density, B........... Unlimited
Reverse Output Voltage, V Continuous Output Current,
I
........................... Internally Limited
OUT
Package Power Dissipation,
P
........................................ See Graph
D
Junction Temperature, T Operating Temperature Range, T
Suffix “E–”.................... -40°C to +85°C
Suffix “L–” .................. -40
Storage Temperature, T
......... -0.5 V
OUT
................. 170°C
J
A
°C to +150°C
................. 170°C
S
Each monolithic device contains an integrated Hall-effect trans­ducer, a temperature-compensated comparator, a voltage regulator, and a buffered high-side driver with an active pull-down. Supply protection is made possible by the integration of overvoltage shutdown circuitry that monitors supply fault conditions. Output protection circuitry includes source and sink current current limiting for short circuits to supply or ground.
The A3195E– is rated for operation over a temperature range of
-40°C to +85°C; the A3195L– is rated for operation over an extended temperature range of -40°C to +150°C. They are supplied in a three­lead SIP (suffix –U) or a surface-mount SOT-89 (suffix –LT).
FEATURES
Internal Protection For Automotive (ISO/DIN) Transients
Operation From Unregulated Supply
Reverse Battery Protection
Undervoltage Lockout
Supply Noise-Suppression Circuitry
Output Short-Circuit Protection
Output Zener Clamp
Thermal Protection
Symmetrical Latching Switch Points
Operable with Multipole Ring Magnets
*Fault condition, internal overvoltage shutdown above 28 V.
Always order by complete part number, e.g., A3195LU .
3195
3
2
1
PROTECTED, HIGH-TEMP., ACTIVE PULL-DOWN HALL-EFFECT LATCH
FUNCTIONAL BLOCK DIAGRAM
V
CC
OVERVOLT.
LOCKOUT
REG.
800
700
600
500
Dwg. FH-013
"U" PACKAGE R
θJA
= 183°C/W
X
LATCH
OUTPUT
CURRENT
15k
LIMIT
GROUND
TRANSFER CHARACTERISTICS
26 V MAX
VOUT(H)
400
300
200
100
0
ALLOWABLE PACKAGE POWER DISSIPATION IN mW
"LT" PACKAGE R
θJA
= 258°C/W
20
60 100 140 180
40 80 120
AMBIENT TEMPERATURE IN °C
160
Dwg. GH-054A
OUTPUT VOLTAGE IN VOLTS
0
-B
B
RP
0+B
FLUX DENSITY
B
OP
OUT(L)
V
Dwg. GH-034-3
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000
W Copyright © 1995, 1997, Allegro MicroSystems, Inc.
3195
PROTECTED, HIGH-TEMP., ACTIVE PULL-DOWN HALL-EFFECT LATCH
ELECTRICAL CHARACTERISTICS over operating voltage and temperature range (unless otherwise specified).
Limits
Characteristic Symbol Test Conditions Min. Typ. Max. Units
Supply Voltage V Overvoltage Shutdown* V Output Voltage, High V
(Source Voltage)
CC
CC(OV)
OUT(H)
Operating (but VCC x ICC VS TA limited) 3.8 12 26 V B > B B < B
OP
= -20 mA VCC -2 VCC -0.3 V
RP, IOUT
28 55 V
Output Voltage, Low V
OUT(L)
(Sink Voltage) B > B Output Clamp Voltage V Output Current Limit I
Supply Current I
Reverse Battery Current* I
Output Rise Time t Output Fall Time t Package Thermal Resist. R
OUT(CLMP)
OUTMAX
CC
RCC
r
f
θJA
B > B
B < BRP, VCC > 26 V, I
<100 µA 0.1 0.2 V
OP, IOUT
= 5 mA 0.25 0.5 V
OP, IOUT
= 0 15 18 21 V
OUT
B < BRP, VCC = 12 V -26 -70 mA B > B
B < BRP, VCC = 18 V, I B > B V
V V
, V
OP
OP
= +115 V* 8.0 17 mA
CC
= -35 V* -0.1 -5.0 mA
RCC
= -100 V* -0.1 -10 mA
RCC
< 14 V 8.0 25 mA
OUT
= 0 6.0 9.0 mA
OUT
, VCC = 18 V, I
= 0 8.0 12 mA
OUT
CL = 20 pF, RL = 330 0.12 2.0 µs CL = 20 pF, RL = 330 0.30 5.0 µs “LT” Package 258 °C/W
“U” Package 183 °C/W
MAGNETIC CHARACTERISTICS over operating voltage range (unless otherwise specified).
Limits
Characteristic Symbol Test Conditions Min. Typ. Max. Units
Operate Point B
Release Point B
Hysteresis B (B
- BRP)T
OP
OP
RP
hys
TA = -40°C 60 125 200 G T
= +25°C 50 110 160 G
A
T
= Maximum 40 100 150 G
A
TA = -40°C -200 -125 -60 G T
= +25°C -160 -110 -50 G
A
T
= Maximum -150 -100 -40 G
A
TA = -40°C 150 250 G
= +25°C 130 220 G
A
T
= Maximum 110 200 G
A
NOTES: Negative current is defined as coming out of (sourcing) the output.
BOP = magnetic operate point (output turns ON); BRP = magnetic release point (output turns OFF). As used here, negative flux densities are defined as less than zero (algebraic convention). Typical values are at TA = +25°C and VCC = 12 V. * Fault condition. Device is shut down and operation is not possible.