Aleen VME4000 Service Manual

VME 4000
Installation and Programming Manual
Release 6 February 2002
This publication refers to the VME 4000 Voice Mail System, Release 6. Additional copies of this manual may be obtained from Aleen Technologies Reproduction
of this manual or parts thereof without written permission from Aleen Technologies is strictly prohibited.
Aleen Technologies reserves the right to modify the hardware and software described herein without prior notice. However, changes made to the hardware or software described do not necessarily render this publication invalid.
WARRANTY
In the event that the product proves to be defective in workmanship or materials within a period of one year from date of shipment, Aleen Technologies shall repair or replace the same at its discretion. Transportation will be the responsibility of the dealer/distributor.
Under no circumstances shall Aleen Technologies be liable for consequential or special damages, loss of revenue or user/dealer expenses arising out of or in connection with the use or performance of the product, whether base on contract, tort or any other legal agreement.
The following shall void the above warranty: malfunctions resulting from fire, accident, neglect, abuse or acts of God; use of improper electrical power; or repair of, tampering with or alteration of the product by anyone other than Aleen Technologies authorized personnel.
Table of Contents
1. INTRODUCTION.................................................................................................................1-1
1.1 F
EATURES AND SERVICES
................................................................................................1-2
1.1.1 System Features.......................................................................................................1-2
1.1.2 Automated Attendant Features................................................................................1-3
1.1.3 Voice Mail Features................................................................................................1-6
1.2 A
BOUT THIS MANUAL
......................................................................................................1-8
2. DESCRIPTION AND INSTALLATION............................................................................2-1
2.1 T
2.2 P
HE BASIC SYSTEM HYSICAL DESCRIPTION
..........................................................................................................2-2
...................................................................................................2-2
2.2.1 Side Panel................................................................................................................2-3
2.2.2 Front Panel..............................................................................................................2-3
2.3 I
NSTALLATION
.................................................................................................................2-4
2.3.1 Unpacking ...............................................................................................................2-4
2.3.2 Installing the VME 4000..........................................................................................2-5
2.3.3 Expanding the System to Four Lines.......................................................................2-7
3. DTMF PROGRAMMING....................................................................................................3-1
3.1 E
NTERING AND EXITING THE PROGRAMMING MODE
.......................................................3-1
3.2 F
3.3 D
3.4 S
3.5 P
3.6 P
IRST TIME PROGRAMMING CHECKLIST
EFINING ETTING THE TIME AND DATE ROGRAMMING THE OPERATIONAL MODE ROGRAMMING THE
PBX P
ARAMETERS
VME 4000 ....................................................................................3-10
..........................................................................................3-3
.........................................................................................3-8
..........................................................................3-2
......................................................................3-8
3.6.1 Creating Mailboxes...............................................................................................3-10
3.6.2 Creating Mailbox Groups .....................................................................................3-12
3.6.3 Notification............................................................................................................3-13
3.7 P
ROGRAMMING THE AUTOMATED ATTENDANT SCRIPT MENU
......................................3-17
3.7.1 Recording Script Messages...................................................................................3-17
3.7.2 Programming Script Messages .............................................................................3-18
3.7.3 Directory Listing Programming............................................................................3-25
VME 4000 Installation and Programming Manual a
Table of Contents
3.7.4 Reset Script Message Programming to Default....................................................3-26
3.7.5 Supervised, Semi-Supervised and Non-Supervised Transfers...............................3-26
3.8 A
DDITIONAL FEATURES
.................................................................................................3-29
3.8.1 Changing Passwords.............................................................................................3-29
3.8.2 Activate Force Reorganize....................................................................................3-30
3.8.3 Changing to/from Day Light Saving Time ............................................................3-31
3.8.4 Changing the Operational Mode...........................................................................3-31
3.8.5 Playing a System Message ....................................................................................3-32
3.8.6 Playing All System Messages................................................................................3-32
3.8.7 System Message Setting.........................................................................................3-32
3.8.8 Listening to the Software Version Number ...........................................................3-33
3.8.9 Resetting the System..............................................................................................3-33
3.8.10 Adjusting Recording Length..................................................................................3-33
4. PROGRAMMING BY COMPUTER..................................................................................4-1
4.1 C
4.2 S
4.3 I
4.4 S
ONNECTING THE YSTEM REQUIREMENTS
NSTALLING THE
TARTING
VUP................................................................................................................4-3
VME 4000 TO T
HE COMPUTER
.........................................................4-1
..................................................................................................4-2
VUP......................................................................................................4-2
5. USER OPERATION INSTRUCTIONS..............................................................................5-1
5.1 I
5.2 U
5.3 R
5.4 M
NTRODUCTION
SER’S MAIN MENU
ETRIEVE MESSAGE MENU
AILBOX PARAMETERS
.................................................................................................................5-1
........................................................................................................5-1
..............................................................................................5-1
...................................................................................................5-2
5.4.1 Record Greeting......................................................................................................5-3
5.4.2 Record Name...........................................................................................................5-3
5.4.3 Directory Listing .....................................................................................................5-4
5.4.4 Change Password....................................................................................................5-4
5.4.5 Do Not Disturb (DND)............................................................................................5-5
5.4.6 External Notification...............................................................................................5-5
b VME 4000 Installation and Programming Manual
Table of Contents
5.4.7 Pager Notification...................................................................................................5-6
5.4.8 Return to Previous Menu.........................................................................................5-6
5.5 S
5.6 R
5.7 Q
END MESSAGE
ETURN TO AUTO ATTENDANT
UICK REFERENCE GUIDE
................................................................................................................5-7
........................................................................................5-7
...............................................................................................5-8
6. PROGRAMMING THE IN-BAND DTMF PROTOCOL................................................6-1
6.1 P
ROGRAMMING THE
VME 4000
BY TELEPHONE
.............................................................6-1
6.1.1 Defining an In-Band DTMF Code for an Event......................................................6-1
6.1.2 Selecting an Operation Type...................................................................................6-3
6.1.3 Selecting a destination.............................................................................................6-4
6.1.4 Defining the Time to Wait for the First DTMF Character......................................6-4
6.1.5 Defining the Time to Wait Between DTMF Characters..........................................6-4
6.1.6 MATRA Support ......................................................................................................6-5
6.2 S
AMPLE PROGRAMMING
..................................................................................................6-5
6.2.1 Working with the SIEMENS Hicom 150E Office PBX............................................6-5
7. TROUBLESHOOTING........................................................................................................7-1
APPENDIX A PROGRAMMING COMMANDS ....................................................................A-1
APPENDIX B PROGRAMMING FORMS...............................................................................B-1
APPENDIX C SYSTEM MESSAGES.......................................................................................C-1
APPENDIX D SPECIFICATIONS ............................................................................................D-1
VME 4000 Installation and Programming Manual c
1. INTRODUCTION
The VME 4000 is a small stand alone multilingual Voice Mail/Automated Attendant system for organizations that have between eight and eighty employees. The VME 4000 incorporates state of the art technology, including DSP, flash memory and SMT production.
Figure 1-1 General View
The VME 4000 is available in two or four ports and with up to 128 mailboxes. It provides up to 10 hours of recording time.
The VME 4000 can be integrated with most types of PBX’s through the analog ports or through the RS-232 serial port.
The system administrator can be programmed by the computer using the Voice Mail Utility Program (VUP) or by touch-tone telephone.
VME 4000 Installation and Programming Manual 1-1
Introduction
Installing The VME 4000 is quick and easy. Just mount it on a wall next to the PBX and connect it to the SLT interfaces and to the main power supply with an external power adapter.
The VME 4000 is ready for use immediately after the system administrator completes a short procedure that includes setting up integration parameters, mailboxes, notification type, system schedules and opening greetings. Mailbox owners can then set up their own personal mailbox parameters.
1.1 Features and Services
The VME 4000 is a powerful voice mail system at an affordable price. It contains most of the useful features and services provided by PC-based systems but at a lower cost. The VME 4000’s features can be divided into three groups:
x System Administration x Automated Attendant x Voice Mail
1.1.1 System Features
x Configuration
The VME 4000 is available with two ports and 10 hours of recording time. The system administrator can upgrade the VME 4000 by adding a two port expansion card to the motherboard to provide four ports
x Programming
The system administrator can program the VME 4000 by:
 Touch-tone telephone using DTMF tones  Computer using the Voice Mail Utility Program (VUP). The installer
should save the files containing the parameters set in each installation.
x Integration with your PBX
The system administrator can integrate the VME 4000 with the PBX through:  In-Band DTMF Protocol integration using DTMF strings. This type of
integration is achieved by setting up the communication parameters on the PBX and the VME 4000, including answering a call, transfer, recall from busy, recall from no answer, the notification parameters and more.
1-2 VME 4000 Installation and Programming Manual
Introduction
 Out-band integration through a serial port (RS-232) applying the PBX
parameters to the VME 4000. This type of integration must be developed separately for each type of PBX.
x Loop Current Disconnection
Some PBXs have the capability, which enables them to notify the VME 4000 through the line interface when a call is terminated. When this situation is detected by the Voice mail, the line is disconnected and the VME 4000 is then ready to receive another call.
x Message Notification
The VME 4000 automatically notifies the mailbox owner of new messages in different ways according to the system configuration. Notification may be local (to a PBX extension) or remote (to a telephone at a remote location, a cellular telephone or a pager).
x Security Passwords
The VME 4000 supports three types of passwords, each with four digits:
 System Administrator. Gives access to all data stored in the VME 4000.  Operator. Gives access to the operating modes of the system. The available
operating modes are: Day, Night, Holiday and Break.
 Mailbox. Gives access to individual mailboxes. Mailbox owners can
change the password at any time.
x Line Monitor
The VME 4000 sends all incoming DTMF codes to the VUP from all the ports, simultaneously through the RS-232 cable. The line monitor is a powerful tool to simplify the integration and installation of the VME 4000 with the PBX.
1.1.2 Automated Attendant Features
The VME 4000’s automated attendant answers incoming calls and through a series of recorded menus and telephone directories, helps the callers reach the desired extensions.
x Opening Greeting
The VME 4000 plays a pre-recorded greeting to callers. The opening greeting usually includes the organization’s name, how to reach an extension,
VME 4000 Installation and Programming Manual 1-3
Introduction
department or operator, how to switch languages, how to leave a message and to access a directory.
During the greeting, callers can access a department by dialing a single digit, dialing the extension number or holding for assistance.
x Operating Modes
Depending on the time and the system schedule, the VME 4000 answers external calls with one of four opening greetings:
 Day Mode
During normal business hours, the VME 4000 answers calls with a pre­recorded daytime greeting. The daytime greeting enables the caller to reach a requested extension, mailbox, department, and directory or to switch languages.
 Night Mode
During non-working hours, the VME 4000 answers calls with a pre­recorded nighttime greeting that enables the caller to leave a message in a requested mailbox.
 Holiday Mode
During holidays, the VME 4000 answers calls with a special greeting that enables the caller to leave a message in a specific mailbox or in the operator’s mailbox.
 Break Mode
The system administrator can program part of the day mode as break time. During break time, the VME 4000 answers calls with a special greeting that enables the caller to leave a message in a specific mailbox or in the operator’s mailbox.
x System Schedules (Auto-Mode)
If your organization has operating hours that vary from day to day, the system administrator can define the daily operating schedules on a weekly basis, including daytime, nighttime and break time hours. When the Auto mode is activated, the VME 4000 automatically switches between the day, night and break modes according to the pre-defined schedule.
The operator can override the pre-defined system schedule and switch manually to day, night, break, or holiday mode using a password.
1-4 VME 4000 Installation and Programming Manual
Introduction
x Holiday Schedules
The VME 4000 switches automatically to Holiday mode on dates programmed as holidays. During holidays the VME 4000 answers calls with the special holiday greeting.
x Fax Detection
If the VME 4000 detects a fax tone (CNG) during the opening greeting, it automatically transfers the call to the pre-defined fax extension.
x Directory Listing (Dial By Name)
The VME 4000 can provide a list of mailbox owner names. The directory
listing enables calls to be transferred to all extensions configured within the
list. A caller can access the directory listing by following instructions during
the opening greeting.
In order to enable a directory listing call transfer, the mailbox owner must
record his name and a three-letter code. A caller can reach the proper extension
after dialing the respective code and verifying a correct extension according to
the mailbox owner’s name.
The system administrator enables two methods of directory listing: according
to the mailbox owners first or last name.
x Call Transfer
The system administrator can program the VME 4000 to detect the Call Progress tone and DTMF signals sent by the PBX and transfer the calls to extensions in one of the following modes:
 Non-Supervised
. The VME 4000 transfers the call immediately without
verifying the status of an extension.
 Supervised
. The VME 4000 checks for a busy or answer signal before
transferring the call to an extension.
 Semi-Supervised
. The VME 4000 only checks for a busy signal before
transferring the call to an extension.
x Multilingual Option
The VME 4000 can operate in three languages simultaneously. The system administrator can configure each mailbox to operate in one of the three selected languages. The caller can select the language in which the system messages (prompts) are played.
VME 4000 Installation and Programming Manual 1-5
Introduction
x Answering on the First Ring
To avoid delays, the system administrator can set up the VME 4000 on each individual port to answer incoming calls on the first ring.
x Script Menus
The VME 4000 supports up to 39 script menus. A script menu is a recorded announcement that can accept a digit entry (0-9) during playback. Based on the digit entered, the VME 4000 can take one of the following actions:
 Transfer the call to another script menu  Transfer the call to another script menu and change the language  Transfer the call to an extension or hunt group  Transfer the call to a mailbox or a mailbox group  Dial a string of DTMF (10 different strings and up to 20 digits for each
string including special characters)
 Retrieve messages from a mailbox  Disconnect the line  Leave a message  Play the directory listing  Record a call
1.1.3 Voice Mail Features
The VME 4000 enables a caller to leave a message, recorded in his own voice, in any mailbox. The mailbox owner can access his/her mailbox at any time from any touch-tone telephone and listen to his/her messages. Mailbox owners can also modify their own mailbox parameters.
x Real/Virtual Mailboxes
The VME 4000 supports up to 128 real and virtual mailboxes. A real mailbox has a telephone extension, whereas a virtual mailbox does not.
x Personalized Mailboxes
Mailbox owners can personalize their mailboxes by recording a personal
greeting, assigning a personal password to the mailbox and setting optional
parameters.
1-6 VME 4000 Installation and Programming Manual
Introduction
x Personal Greeting
Mailbox owners can record or change personal greetings at any time from any
touch-tone telephone. Callers first hear the personal greeting of the extension
called and then they can leave a message.
x Day and Time Stamp
The system administrator can program the VME 4000 to indicate the start of each message and the day and time it was recorded.
x Message Deletion
Mailbox owners can manually delete messages or the system administrator can
program the VME 4000 to automatically delete all messages after a specified
number of days.
x Message Forwarding
Mailbox owners can forward copies of messages to other mailboxes or mailbox groups. Mailbox owners can also record an introduction to the forwarded message.
x Message Reply
Mailbox owners can reply, directly, to a message and record a message in the sender’s mailbox.
x Mailbox Groups
A caller can send a message to all the members of a mailbox group at one time.
All defined mailboxes belong to the “All Group” mailbox group. In addition, the system administrator can create up to four mailbox groups, each containing up to twenty mailboxes. Mailboxes can belong to more than one group and can be added to or deleted from a mailbox group by the system administrator. Each mailbox group can be assigned with a mailbox group greeting.
x Do Not Disturb Mode
Mailbox owners can set their mailboxes in the Regular Mode or Do Not
Disturb Mode. When a caller dials a Do Not Disturb extension using the
Automated Attendant menus, the VME 4000 plays a special “Do Not Disturb”
menu and does not transfer the call to the extension.
x Individual Language Selection
The mailbox owner or caller can select one of the languages supported by the
VME 4000. When the mailbox owner or caller enters the mailbox, the VME
4000 automatically switches to the selected language.
VME 4000 Installation and Programming Manual 1-7
Introduction
x Adjustable Recording Length
The system administrator can select the length of all recorded messages in the
VME 4000. The selected length will control the following types of messages:
scripts, greetings, names and incoming messages. Changing this parameter will
affect the operation VME 4000.
x Automatic Gain Control (AGC)
When this feature is enabled, the VME 4000 automatically adjusts the line
volume so incoming messages will be recorded at the same level.
1.2 About this Manual
This manual presents information needed to install, program and maintain the VME 4000. It is divided into the following sections:
1. INTRODUCTION
Introduces the VME 4000 and lists its features.
2. DESCRIPTION AND INSTALLATION
Provides a functional description of the VME 4000 and installation instructions.
3. DTMF PROGRAMMING
Describes how to program the VME 4000 from any DTMF telephone.
4. PROGRAMMING BY COMPUTER
Describes the installation and basic operational concepts of the Voice Mail Utility Program (VUP).
5. USER OPERATING INSTRUCTIONS
Explains how to program and use a mailbox.
6. PROGRAMMING THE IN-BAND PROTOCOL
Describes how to program the VME 4000 to detect the In-Band DTMF protocol sent by the PBX.
7. TROUBLESHOOTING
Presents answers to commonly asked questions on operating the VME 4000.
APPENDIX A
Summarizes the programming commands.
APPENDIX B
Contains the DTMF programming forms.
1-8 VME 4000 Installation and Programming Manual
Introduction
APPENDIX C
Lists the system messages.
APPENDIX D
Lists the system specifications.
VME 4000 Installation and Programming Manual 1-9
2. DESCRIPTION AND INSTALLATION
The VME 4000 is a digital system consisting of a:
x Sophisticated DSP voice-processing device x Flash memory for storing voice recording and parameter data x Central Processing Unit x Two or four ports x Real-time clock
The VME 4000 provides two major services: x Automated Attendant
Uses menus and sub-menus to transfer calls to specific departments, extensions or mailboxes.
x Voice Mail
Receives and delivers messages. Each mailbox has its own number and mailbox owners have passwords enabling them access to their mailboxes.
Messages can be saved, deleted or transferred to other mailboxes. Mailbox owners can also send identical messages to groups of mailboxes or to all the mailboxes in the system.
By configuring the following, the VME 4000’s Automated Attendant and Voice Mail System can be customized to suit the needs of the company:
x PBX parameters x Automated Attendant script menus and customized “Busy”, “No Answer” and
“Do Not Disturb” menus in up to three different languages simultaneously.
x Voice Mail features include: mailboxes, mailbox groups and various types of
message notifications for each mailbox
VME 4000 Installation and Programming Manual 2-1
Description and Installation
2.1 The Basic System
The VME 4000 comes with two lines and 10 hours recording time. You can upgrade the VME 4000 by adding a two line expansion card to the motherboard to provide four lines
Figure 2-1 Options for Upgrading the Basic System
2.2 Physical Description
The functional components of the VME 4000 are located under the side panel cover. The LEDs are on the left side of the front panel. The bottom panel has two indented holes for wall mounting.
Figure 2-2 General View of the VME 4000 after Removing the Cover
2-2 VME 4000 Installation and Programming Manual
Description and Installation
2.2.1 Side Panel
Figure 2-3 Side Panel
The numbered items in the following description correspond to the labels in Figure 2-3.
1. Power Supply Connector Connects the
VME 4000
to the external power
supply
2. RS-232 Connector Connects the
3. 2 RJ-11 Sockets Connects the
VME 4000 VME 4000
to the PBX or a PC to 2 or 4 PBX
extensions
2.2.2 Front Panel
Figure 2-4 LEDs on the Front Panel
VME 4000 Installation and Programming Manual 2-3
Description and Installation
The following table describes the function of the four LEDS on the front panel.
STATUS DAY NIGHT HOLIDAY AUTO
Day Mode: Manual On Off Off Off Night M o d e : Manual Off On Off Off Holiday Mode: Manual Off Off On Off Break Mode: Manual On On Off Off Day Mode: Auto On Off Off On Night Mode: Auto Off On Off On Break Mode: Auto On On Off On System Error1 Off Flashing Off Off System Error1 Flashing Flashing Flashing Flashing System Error1 Flashing Flashing Flashing Off Automatic Self-Test On On On On
1
Please contact your local dealer.
2.3 Installation
The VME 4000 is delivered completely assembled. It is designed for mounting on a wall close to the PBX.
2.3.1 Unpacking
Before unpacking, inspect the package, if you notice any damage, immediately report it to your local dealer.
¾
To unpack the VME 4000:
1. Place the package on a flat surface and open it.
2. Remove the contents of the package and place them on a clean surface.
3. Remove all packing material.
4. Inspect the contents, if you notice any physical damage, immediately
report it to you local dealer.
2-4 VME 4000 Installation and Programming Manual
Description and Installation
2.3.2 Installing the VME 4000
¾ To install the VME 4000:
1. Mount the VME 4000 on a wall close to the PBX cabinet. Use the drill
template to place the two screws.
2. Remove the side panel cover.
3. Connect the RJ-11 connector on one end of the cables to the RJ-11 sockets
on the side panel of the VME 4000. Connect the other end of the cables to one or two analog telephone lines on the Main Distribution Frame (MDF) of the PBX (see Figure 2-5).
Note: Each RJ-11 socket on the side panel of the VME 4000 can support
up to two analog telephone lines.
Figure 2-5 Analog Line Connections
VME 4000 Installation and Programming Manual 2-5
Description and Installation
4. On the side panel of the VME 4000, plug the 9V DC adapter jack into the
power supply connector.
5. Plug the 9V DC adapter into the main power supply outlet to turn the VME
4000 on. The LED’s on the front panel turn on and off, one after another and then the LED indicating the status of the VME 4000 turns on.
6. If your PBX supports full authorized RS-232 integration with the VME
4000, connect one end of the RS-232 cable to the VME 4000’s RS-232 connector and the other end to the RS-232 connector of the PBX.
7. Call each VME 4000 line from any extension and verify the answer. You
should hear the default greeting (system message no. 000. See Appendix C).
8. Replace the side panel cover.
9. Program the VME 4000 according to your PBX type and required
applications.
Figure 2-6 System Installation
2-6 VME 4000 Installation and Programming Manual
Description and Installation
2.3.3 Expanding the System to Four Lines
The two-line expansion kit contains:
x 2-line expansion card x 4-wire cable x Two plastic spacers
¾ To install the expansion card:
1. Disconnect all external cables and connectors.
2. Remove the 9V DC adapter power plug from the main power supply outlet
to turn the VME 4000 off.
3. Open the VME 4000’s top cover by unscrewing the four screws.
4. Place the two plastic spacers into the corresponding holes.
5. Insert the expansion card into the corresponding J6 connector.
6. Connect one end of the 4-wire cable to J5 on the motherboard and the other
end to J5 on the expansion card.
7. Replace the top panel cover and plug the 9V DC adapter into the main
power supply outlet to turn the VME 4000 on.
8. Reconnect all the external cables and connectors to the VME 4000.
Voice Mail System automatically detects four lines when it is turned on.
VME 4000 Installation and Programming Manual 2-7
3. DTMF PROGRAMMING
The VME 4000 can be programmed by:
x Telephone using DTMF tones x Computer using the Voice Mail Utility Program (see Section 4)
This section describes programming the VME 4000 using DTMF tones.
Note: You will hear a confirmation tone every time you enter a programming
command.
3.1 Entering and Exiting the Programming Mode
The VME 4000 does not handle calls when in the programming mode.
¾ To enter the programming mode:
1. Connect a PBX analog line to the VME 4000.
2. Call the PBX analog line from any touch-tone telephone.
3. Wait until the VME 4000 answers and plays the opening menu. Then dial
*900.
4. Dial the System Administrator’s password (the default password is 1234)
to enter the programming mode.
¾ To exit the programming mode:
x Dial *900.
–or– Do not dial for one minute.
Note: If you exit the programming mode by dialing *900, the VME 4000 plays the
opening menu and you can then test the changes made to the system.
VME 4000 Installation and Programming Manual 3-1
DTMF Programming
3.2 First Time Programming Checklist
1. Call from a touch-tone telephone to the VME 4000. You will hear the default message (system message 000 - see Appendix C).
2. Dial *900 and the administrator password (default: 1234) to enter the programming mode.
3. Set the PBX parameters (see Sections 3.3 and Section 6) to ensure the proper operation of the VME 4000 with your PBX.
4. Set the VME 4000’s real-time clock (see Section 3.4).
5. Set the system schedule (see Section 3.5).
6. Create mailboxes (see Section 3.6.1).
7. Define a notification type for each mailbox (see Section 3.6.3).
8. Define notification parameters (i.e., message light on and message light off and interval between ring notification in Section 3.6.3.)
9. Record (see Section 3.7.1) and program (see Section 3.7.2) script menus for the Automated Attendant. Make sure you define the mailboxes before building Automated Attendant script menus.
3-2 VME 4000 Installation and Programming Manual
DTMF Programming
3.3 Defining PBX Parameters
To integrate the VME 4000 with your PBX, apply the PBX parameters to the VME
4000.
To obtain your current PBX parameters, check your PBX User’s Manual or the current PBX setup configuration.
To configure the VME 4000 to detect the in-band DTMF protocol sent by your PBX, refer to Section 6.
Note: Do not forget to enter programming mode by dialing *900 and the
administrators password before using the programming commands.
Table 3-1 presents the commands you must enter to apply the PBX parameters to the VME 4000.
Table 3-1 PBX Parameter Commands
OPERATION COMMAND DEFAULT
Extension size *300 + X
Cut off time for continuous call progress tone detection
No. of rings before the line is answered
Time to wait for No-Answer
where X is a digit 1-4 You can only change this parameter if mailboxes and/or legal extensions have not yet been defined.
*301 + X
where: X = cut off time in seconds (0-9)
*310 + line number + number of rings
Line number = 1-4 Number of rings = 1-9
*311 + XX where XX is 00-99 seconds. This code is applicable only when supervised transfer is selected.
3
6 seconds
1
20 seconds
VME 4000 Installation and Programming Manual 3-3
DTMF Programming
Table 3-1 PBX Parameter Commands (continued)
OPERATION COMMAND DEFAULT
Legal PBX Extensions
Resetting a group *320 + Y + 000 + 000 + # (the two groups of zeros
Resetting all groups
Operator ID Code *330 + X
Programmable code for retrieving messages
Disconnection Code
*320 + Y + First Ext. + Last Ext. + # where Y is a group number (0-9). Example: *320 0 330 350 # *320 1 355 375 # You can define up to 10 groups of legal extensions. If a caller dials an extension by direct dialing (code
170), the VME 4000 checks if the extension is legal. If the extension is not legal, the VME 4000 does not transfer the call.
can be 2, 3, or 4 digits long, according to the extension size)
*320 + #
where X is a digit 0-9 When the caller dials this digit during any script message, the call is transferred to the operator.
*331 + X X = 0-9; Retrieve digit
*333 + CODE 1 + # The VME 4000 terminates a call when it receives
the disconnection code. The code can include up to four digits. Legal values for this code can be any combination of 0-9, *, #, and A-D.
None
0
9
###
Clear Disconnection Code
External Access Code
Clear External Access Code
3-4 VME 4000 Installation and Programming Manual
* 333 + #
*340 + X + #
where X is the external access code (0-9), Pause (*1). This code is applicable for external notification.
*340 + #
9
Loading...
+ 85 hidden pages