1 ECO MODE
This Alecto DBX-85 ECO babyphone is equipped with an unique ECO
mode. Already in normal operation mode, the baby-unit stops transmission when the baby is not crying. In Full Eco mode it even suppresses
the controlling signals between the baby-unit and the parent unit, so no
transmitting at all.
Attention: once the baby produces noise, the baby-unit is activated and
contacts the parent unit. This causes a small delay which means that
short sounds from the baby may not be heard by you. In case you really
want to hear all sounds from the baby room, you must set the sensitivity
to maximum (see chapter 4.5); with this setting the baby-unit is constantly
active.
3
2 OVERVIEW
2.1 OVERVIEW PARENT UNIT:
1. sound indication LED’s
2. volume up; up button when
programming
3. volume down; down button when
programming
4. button to set the sensitivity
5. link-check ( ), see below
6. loudspeaker
1
2
3
4
5
6
7
Link check :
• ashes green when there is no link between baby unit and parent unit
or parent unit is out of range with the baby unit.
• steadily green when linked to the baby unit
• steadily red in FULL ECO MODE and the baby is asleep. Attention: in
this mode there is no active link.
• steadily orange in FULL-ECO-MODE and the baby is crying. The
baby-unit is linked to the parent-unit.
7. charge contacts
8. battery compartment
9. microphone
10. battery-indication ( ): see next
page
11. power on/o
12. talk back
13.
12
11
10
9
8
4
battery indication :
• on steadily when in charging mode
• off when batteries are FULL
• blinks when low battery level is detected
2.2 OVERVIEW BABY UNIT:
1. battery indication: see below
2. built-in nightlight (not visible
when switched-off
3. power on/off
4. microphone
5. DC input for power adapter
1
2
3
4
5
6. battery compartment (backside)
7. loudspeaker
8. on/off indication
9. volume up/down
10. page (to page the parent unit)
11. nightlight on/o
1011
6
9
8
7
battery indication :
• lights yellow when batteries are installed and the power adapter is
connected to indicate that batteries are being charged (does NOT
goes off when batteries are fully charged)
• off when batteries are FULL
• blinks red when low battery level is detected
5
3 INSTALLATION
3.1 PARENT UNIT:
The parent unit is powered by 2 supplied rechargeable batteries. These
batteries are charged through the included power adapter.
NEVER INSTALL NORMAL BATTERIES IN THE PARENT UNIT.
NORMAL BATTERIES CANNOT BE CHARGED. RISC OF
EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
1. Remove the belt clip with the help of a small screwdriver
2. Remove the battery compartment cover.
3. Insert 2 x AAA rechargeable batteries, observing their
polarities, into the battery compartment on the parent
Unit. Only use the supplied batteries with the following
specifications:
voltage / capacity: 1.2V / 750mAh or more
material / size: NiMH, AAA, HR03
4. Replace the battery door on the Parent unit
5. Connect the output plug of the mains adapter to the charger-pod and
put the parents-unit onto the charger-pod to charge the batteries
Attention: remain on, even when the batteries are charged.
The charging of empty batteries takes about 24 hours..
3.2 BABY-UNIT:
The baby-unit is powered by the supplied power adapter.
Only connect the provided power adapter with the following specifications: Input: 100-240VAC 150mA; Output: 9VDC 500mA
For portable use you can install 4 pcs RECHARGEABLE batteries.
ATTENTION:
6